CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Similar documents
CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Application Your benefits

Chloromax CCS142D. Technical Information

OCS 140 / 141 Sensors for Free Chlorine Operating Instructions

ISEmax CAM40/CAS40. Technical Information

CHLORINE THEORY & MEASUREMENT

Free Chlorine Amperometric 4-20mA Sensors

ph/redox Measurement CPM 280

Residual Chlorine Monitor

FC80 Free Chlorine Analyzer ELECTRO-CHEMICAL DEVICES

Process Instrumentation analyzers

ISEmax CAS40D. Technical Information

Meinsberger Chlorine Measuring

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

FC400G Free Available Chlorine Analyzer (Reagent-Free Type) 1. Overview Features What is Residual Chlorine...4

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

Frequently asked question about our new Platinum Water Ionizer

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Understanding Chlorine Measurement. Rebecca Luedee Environmental Sales

GS4000 DATASHEET JUNHO 2013

WATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity

Electrolysis System CHLORINSITU V (PLUS)

PAA-ANALYZERS PRINCIPLE OF OPERATION

STANDARD OPERATING PROCEDURE

Conductivity sensor for hygienic applications

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Immediate Free Chlorine Correction for Fluctuating Flow & Changes in Water Quality. Sadiq Khan May 25th, 2016

Paper 4.3. Introduction

OEM ph Competences. Solutions for ph OEM Applications in Liquid Analysis

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

BASU. Healthcare. Knowledge brings the greatest benefit

Pressure Measurement Single-range transmitters for general applications

ORP Probe. Mini ORP. Reads. +/-2000mV. Range SMA. Connector. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

NH 3 -selective electrodes

Automatic titrators, TitroMatic

ph Probe Spear Tip Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth

DBP Control: Chloramine Chemistry. Chris Griffin Hach Company

The ph Value The ph value is a logarithmic measure for the concentration of the H ions in a hydrous solution and indicates, by a numerical value, whet

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

TCEQ Directed Assistance Module (DAM) No. 5: Understanding and Controlling the Chloramination Process

Chemistry MultiMeasure Sensor PS-2170

Combination ph, ORP, T Electrode with Transmitter

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

One-hand ph/temperature measuring instrument

CHLORINE, FREE, Ultra-high Range ( mg/l Cl 2 ) Method 10069

Series 210 Amperometric Residual Chlorine Analyzer

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.

Analysis of Free Ammonia in Chloramination Applications Using Lab Method and the APA6000

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

COLE-PARMER INDUSTRIAL AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER INDUSTRIAL POTASSIUM ION ELECTRODE INSTRUCTION MANUAL

METHODS FOR DETERMINATIONS OF ELECTROLYTES AND BLOOD GASES

Stamolys CA71HA. Technical Information

Compact ph Measuring Instruments With Pro Engineering

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

EASYLYTE Na/K/Cl/Ca/Li SOLUTIONS PACK REF mL

ph Probe Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth 1 99 C

symphony Multisensor Probes

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Rotary modules.

Definition 1 An element or compound is oxidized when it gains oxygen atoms

Science of Chloramination. Maine Water Utilities Association June 8, 2010

Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

DPD Test N Tube Method *

Air velocity & IAQ measuring instruments

ORP Probe ORP. Reads. +/-2000mV. Range. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C. Temperature range C.

Rapid RH Portable ph Meter. User's Manual

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

The FLUX F 430 with mechanical seal

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Exercise 2-4. Titration of a Buffer Solution EXERCISE OBJECTIVES

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015

N) manual. Biomaster Operating manual

Air velocity & IAQ measuring instruments

Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

LOW-RANGE TOTAL CHLORINE

Disinfection Overview. Learning Objectives. Topics to be Covered. Be able to discuss the purpose and types of disinfection

Module 20: Corrosion Control and Sequestering Answer Key (edited April 2017)

Chlorine disinfectant in the water industry

Titration of a strong acid with a strong base with Cobra4

Understanding ph Troubleshooting and Diagnostic information

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Using Sanitizers in Postharvest Water Amanda Deering, Ph.D. Department of Food Science

Exercise 2-2. Titration of a Strong Acid EXERCISE OBJECTIVES

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

TOP Offers Special Measuring Instruments

INSTRUCTION MANUAL. Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN Introduction Helpful Operating Tips. 2

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

Manual ph Probe & Oxidation Reduction Potential Probe Models 6528A and 6528B

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Electrodes for ph measurements. - when you need to be sure...

Series 250 Amperometric Residual Chlorine Analyzer

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Electricity. Electrolysis. Current and the transport of charge DETERMINATION OF THE FARADAY CONSTANT BASIC PRINCIPLES

Transcription:

Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Oxidising agents such as chlorine or anorganic chlorine compounds are used for disinfection of water. Their dosing must be carefully controlled to suit the application. Too low a concentration makes the degree of disinfection questionable. Too high a concentration can result in corrosion effects, impairment of taste or skin irritation. The CCS140 and CCS141 chlorine sensors are applied for measurement of free active chlorine in the following fields: Drinking water treatment Pool water treatment Industrial water treatment Your benefits Measurement in the CCA250 flow assembly is almost independent of flow rate in the range above 30 l/h No zero point calibration necessary. This means complicated installation of an active carbon filter, as in open chlorine sensors, is not necessary. Measured values are not affected by conductivity fluctuation of the medium. The CCS140 sensor is ready for measurement after a polarisation time of approx. 30... 60 minutes. The CCS141 sensor requires 45... 90 min. Easy membrane replacement thanks to ready-made membrane head Recalibration intervals approx. 1... 4 months under constant operating conditions TI00058C/07/EN/13.12 71189745

Function and system design Function Measuring principle Measuring of free chlorine The CCS140 and CCS141 sensors are used for measurement of free chlorine. The membrane-covered CCS140 and CCS141 sensors consist of a cathode serving as the working electrode and an anode acting as the counter electrode. These electrodes are immersed in an electrolyte. Electrodes and electrolyte are separated from the medium by a membrane. The membrane prevents the loss of electrolyte and the penetration of contaminants, but free chlorine will pass. To calibrate the measuring system, determine the content of free chlorine using the DPD method. You need a photometer with the pertaining reagents. The determined value is the calibration value for the transmitter. The concentration of free chlorine is determined according to the amperometric measuring principle. The hypochlorous acid (HOCl) contained in the medium diffuses through the sensor membrane and is reduced to chloride ions (Cl - ) on the gold cathode. On the silver anode, silver is oxidized to silver chloride. The electron release of the gold cathode and electron acceptance on the silver anode result in a current flow which is proportional to the free chlorine concentration in the medium under constant conditions. The concentration of hypochlorous acid in the medium depends on the ph value. This dependence can be compensated by measuring the ph value in the flow assembly. The transmitter transforms the current signal into the measuring unit concentration in mg/l. Molecular chlorine (Cl 2 ) has ph values of < 4. Hypochlorous acid (HOCl) and hypochlorite (OCl ) remain within the range of ph 4 to 11 as components of free chlorine. As hypochlorous acid dissociates with an increasing ph value to form hypochlorite ions (OCl ) and hydrogen ions (H + ), the amounts of the individual components in free chlorine change with the ph value (Fig. ). For example, if the amount of hypochlorous acid is 97% at ph 6, it drops to about 3% at ph 9. Hypochlorous acid has a highly disinfecting effect in an aqueous solution but the disinfecting effect of hypochlorite is extremely low. Therefore, chlorine is not suitable as a disinfecting agent at high ph values. 100 % 80 A 0 20 HOCl 60 40 C 40 60 OCl - 20 B 80 % Schematic diagram of ph compensation A Measured value with ph compensation B Measured value without ph compensation C ph compensation 0 100 4 5 6 7 8 9 10 11 ph a0002017 The CCS140 or CCS141 chlorine sensors selectively measure the amount of hypochlorous acid in amperometric measurement. They do not measure the amount of hypochlorite ions because these ions do not permeate through the sensor membrane. 2

ph compensation of chlorine sensor signal for free chlorine (for transmitter Liquisys CCM223 or CCS253 only on ES and EP versions) To calibrate and inspect the chlorine measuring system, a colorimetric reference measurement must be carried out using the DPD method. Free chlorine in the form of hypochlorous acid reacts with diethyl-p-phenylenediamine and forms a red dye. The intensity of the red pigmentation increases proportionally to the chlorine content. In the DPD method the measuring water is constantly buffered to a ph value of about 6.3. Free chlorine is available as nearly 100 % hypochlorous acid HOCl. Therefore, the ph value of the measuring water is not included in the DPD measurement. Due to the buffer function in the DPD method, all components of free chlorine are detected and thus the total free chlorine is measured. If you select ph compensation in the transmitter, the sum of hypochlorous acid and hypochlorite corresponding to the DPD measurement is calculated from the hypochlorous acid measured by the sensor and the ph value in the region of ph 4 to 9. For this calculation, the curve shown in Fig. is stored in the transmitter. When free chlorine is measured with the ph compensation function on, always perform calibration in the ph-compensated operating mode. When you use ph compensation, the measured chlorine value displayed and applied to the instrument output corresponds to the DPD measured value even if the ph values fluctuate. If you do not use ph compensation, the measured chlorine value only corresponds to the DPD measurement if the ph value remains unchanged compared with the calibration. Without ph compensation the chlorine measuring system must be recalibrated when the ph value changes. Accuracy of ph compensation The accuracy of the ph compensated measured chlorine value depends on the sum of several single measured deviations (chlorine, ph, Temperature, DPD measurement etc.). High amounts of hypochlorous acid (HOCl) during chlorine calibration have positive effects on the accuracy whereas low amounts of hypochlorous acid have negative effects. Inaccuracy of the ph compensated chlorine value increases the bigger the ph difference between operation and calibration gets or the more inaccurate the single measured values are. Calibration of free chlorine measurement taking into account the ph value The reference measurement (DPD method, photometer) determines the complete free chlorine by buffering to ph 6.2. In contrast to this, amperometric measurement only determines the HOCl components. The ph compensation causes the HOCl value to be increased to the actual value of free chlorine. During operation, ph compensation is active up to a ph value of 9. Since there is hardly any HOCl left at this ph value and the measured current is very low. Calibration of the complete measuring system makes sense only up to a ph value of the medium of 8 or 8.2. Sensor ph value HOCl content uncompensated value compensated value CCS141 8.2 15 % 12 na 80 na CCS140 8 20 % 4 na 20 na Above these ph values the total measured error of the measuring system is inacceptable. 3

CAL REL REL1 REL2 REL1 REL2 ALARM Measuring system A complete measuring system comprises at least: Chlorine sensor Liquisys M CCM223/253 transmitter Special measuring cable Flow assembly Reference measuring instrument for determination of free chlorine according to the DPD method 8 9 4 5 0.42 25.0 C mg/l E 6 7 3 2 1 Measuring system in the flow mode (example) 1 CCA250 flow assembly 2 Medium inlet 3 Inductive proximity switch for flow 4 monitoring 5 Mounting places for ph/orp sensors Chlorine sensor 6 7 8 9 Medium outlet Sampling tap Sensor cable Transmitter a0003083 4

Measured variable Input Free chlorine: hypochlorous acid (HOCl) Measuring range Signal current CCS140 (for industrial water, pool water): 0.05 to 20 mg Cl 2 /l (25 C (77 F), ph 7.2) CCS141 (for drinking water applications): 0.01 to 5 mg Cl 2 /l (25 C (77 F), ph 7.2) CCS140: approx. 25 na per mg Cl 2 /l (25 C (77 F), ph 7.2) CCS141: approx. 80 na per mg Cl 2 /l (25 C (77 F), ph 7.2) Performance characteristics Response time T 90 < 2 min in applications involving mainly active chlorination Polarisation time CCS140: First polarization: Repolarization: CCS141: First polarization: Repolarization: 60 min 30 min 90 min 45 min Drift Electrolyte service life typically < 1.5 % per month typically 12 months Installation Installation instructions The flow assembly CCA250 is designed for on-site installation of the sensor. In addition to the chlorine or chlorine dioxide sensor, a ph and an ORP sensor can be installed. A needle valve regulates the flow within the range of 30 to 120 l/h (7.9 to 31.7 US.gal/h). When installing the sensor, note the following: The flow must be at least 30 l/h (7.9 US.gal/h). If the flow drops below this value or stops completely, this can be detected by an inductive proximity switch and an alarm signal plus locking of the dosage pumps can be triggered. If the medium is fed back into a surge tank, pipeline or the like, ensure that the thus generated back pressure on the sensor does not exceed 1 bar (14.5 psi) and remains constant. Negative pressure at the sensor, e.g. by feedback of medium to the suction side of a pump, must be avoided. For further installation instructions, see the Operating Instructions of the flow assembly. 5

Storage temperature Environment Filled with electrolyte: Without electrolyte: 5 to 50 C (41 to 122 F) -20 to 60 C (-4 to 140 F) Ingress protection IP 68 (membrane side up to the mounting collar Ø 36 mm (Ø 1.42")) Process Temperature range CCS140: CCS141: 10 to 45 C (50 to 113 F) 2 to 45 C (36 to 113 F) ph range Pressure Flow Flow velocity Calibration CCS140: CCS141: Measurement: Note! Chlorine measurement in the range of ph 8.2 to ph 9 with limited accuracy. Medium in the CCA250 assembly: max. 1 bar (14.5 psi) in the CCA250 assembly: min. 30 l/h (8 US.gal./h) min. 15 cm/s (0.5 ft/s) 4 to 8 ph 4 to 8.2 ph 4 to 9 ph 6

Mechanical construction Dimensions 148 (5.83) Ø 36 (1.42) Ø 29 (1.14) Ø12 (0.47) 6.5 (0.26) 160 (6.30) Ø 25 (0.98) 74 (2.91) 88 (3.46) A Dimensions A Version with TOP68 plug head B Version with fixed cable B a0018232 Weight approx. 0.5 kg (1.1 lb.) Material Sensor shaft: Membrane: Membrane cap: Cathode: Anode: PVC PTFE PBT (GF 30), PVDF Gold Silver / silver chloride Cable connection Cable length Temperature sensor Version with fixed cable (3 m (9.84 ft)), four cores, double-screened, low noise Version with TOP68: To be used with CPK9-N*A1B (* = length of cable) max. 30 m (98 ft) (cable extension included) NTC, 10 kω at 25 C (77 F) 7

Ordering information Order code You can create a valid and complete order code using the Endress+Hauser Configurator tool on the Internet. Enter the following address into your browser to access the relevant product page: www.products.endress.com/ccs140 or www.products.endress.com/ccs141 1. You can choose from the following options on the product page located on the right: 2. Click "Configure this product". 3. The configurator opens in a separate window. You can now configure your device and receive the complete order code that applies for the device. 4. Afterwards, export the order code as a PDF or Excel file. To do so, click the appropriate button at the top of the page. Product structure CCS140 The following product structure represents the status of printing. You can create a complete and valid order code on the Internet using the configurator tool. Version A without temperature sensor, 3 m cable N with NTC temperature sensor, 3 m cable P plug TOP68, with NTC temperature sensor CCS140- complete order code Product structure CCS141 The following product structure represents the status of printing. You can create a complete and valid order code on the Internet using the configurator tool. Version N with NTC temperature sensor, 3 m cable P plug TOP68, with NTC temperature sensor CCS141- complete order code Scope of delivery The scope of delivery comprises: 1 chlorine sensor 1 bottle filled with electrolyte (50 ml) 1 cap for protection and storage 1 replacement cartridge with pretensioned membrane Operating Instructions, English 8

Accessories Installation accessories Connection accessories Transmitter Maintenance /calibration Flowfit CCA250 Flow assembly for chlorine, chlorine dioxide, ph and ORP sensors Ordering acc. to product structure ( > online Configurator, www.products.endress.com/cca250) Technical Information TI062C/07/EN Compact measuring station CCE10/CCE11 Panel mounted ready for connection for holding one transmitter, with flow assembly CCA250 Ordering acc. to product structure, s. Technical Information TI440C/07/EN Junction box VBC Metallic junction box for cable extension, Dimensions (W x D x H): 125 x 80 x 54 mm / 4.92 x 3.15 x 2.13 inches Order no. 50005181 CYK71 measuring cable Non-terminated cable for the connection of sensors (e.g. conductivity sensors) or the extension of sensor cables Sold by the meter, order numbers: non-ex version, black: 50085333 Ex version, blue: 51506616 CPK9 special measuring cable For sensors with TOP68 plug-in head, for high-temperature and high-pressure applications, IP 68 Ordering acc. to product structure, see Technical Information (TI118C/07/en) Liquisys M CCM223/253 Transmitter for chlorine, field or panel-mounted housing, Hart or PROFIBUS available Ordering acc. to product structure ( > online Configurator, www.products. endress.com/ccm223 or www.products. endress.com/ccm253) Technical Information TI214C/07/EN CCM182 Microprocessor-controlled photometer for determining chlorine and ph value Measuring range for chlorine: 0.05-6 mg/l Measuring range for ph value: 6.5-8.4 Order no.: CCM182-0 Service kit CCS14x For chlorine sensors CCS140/CCS141/CCS142D 2 replacement cartridges, filling electrolyte 50 ml, polishing sheets Order no. 71076921 Polishing sheets COY31-PF 10 pieces for cleaning of the gold cathode For oxygen and chlorine sensors Order no. 51506973 9

10

11

TI00058C/07/EN/13.12 71189745