NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

Similar documents
Process Instrumentation analyzers

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Application Your benefits

Metso Concentration Measurement 3300

ISEmax CAM40/CAS40. Technical Information

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Chloromax CCS142D. Technical Information

Pressure Display Controller

Residual Chlorine Monitor

473-SHX Dew Point Mirror

473 Dew Point Hygrometer

Kjeltec 2300 Analyzer Unit

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

473 Dew Point Hygrometer

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

ADI 2040 Process Analyzer

FC400G Free Available Chlorine Analyzer (Reagent-Free Type) 1. Overview Features What is Residual Chlorine...4

SSi Super Systems Inc.

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Multi-element process analyzer

Photometer AL250. Scroll Memory (SM) N.I.S.T Traceability. Highlights

GS4000 DATASHEET JUNHO 2013

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

University Wet Chemistry Analyzer Packages

Chilled Mirror Hygrometry

CHLORINE THEORY & MEASUREMENT

PAA-ANALYZERS PRINCIPLE OF OPERATION

TECHNICAL DATASHEET OVIVO ANALYZER THM1501. Ovivo Switzerland AG Hauptstrasse 192 CH 4147 Aesch Switzerland

TECHNICAL DATASHEET OVIVO ANALYZER UREA Ovivo Switzerland AG Hauptstrasse 192 CH 4147 Aesch Switzerland

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Understanding Chlorine Measurement. Rebecca Luedee Environmental Sales

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

INFORMATION LABORATORY ANALYSIS UV-VIS SPECTROPHOTOMETER DR Simply more DR 5000 UV-VIS Spectrophotometer

COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

J R. TransTech Systems T S. The World s Number 1 Supplier Of Non Nuclear Density Meters for Asphalt Pavements and Engineered Soils

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Simple Use Compact and Robust Fast and Efficient

ALLOWAY METHOD OUTLINE

Information Technology Solutions Neptune Datasheet

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Thermo Scientific Orion Fluoride Ion Selective Electrodes The standard in fluoride ion analysis EPA compliant

Instruction Manual. Waterproof Portable Colorimeter C401 / 301 / 201 / 101 / 102 / 103 / 104 / 105. Part of Thermo Fisher Scientific

Technical Data Sheet DPT & DPIT-4005 SERIES DIFFERENTIAL PRESSURE TRANSDUCERS. Features. Description

Product Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU

Chlorine, Free and Total, Low Range

One-hand ph/temperature measuring instrument

A new chapter. medicacorp.com

Instruction Manual C401/301/201/102/101. Portable Colorimeter. 99 Washington Street Melrose, MA Phone Toll Free

CHLORINE, FREE, Ultra-high Range ( mg/l Cl 2 ) Method 10069

Chlorine, Free and Total, High Range

Trihalomethane Formation Potential (THMFP)

Using Sanitizers in Postharvest Water Amanda Deering, Ph.D. Department of Food Science

MODEL 107 TEMPERATURE PROBE INSTRUCTION MANUAL

Minute Impulse Clock Controller I01DN

RayBio Nickel Magnetic Particles

Thermal Mass Flow Meter for Gases

TOP Offers Special Measuring Instruments

Automated Clinical Analyzer

Using Sanitizers in Postharvest Water Amanda Deering, Ph.D. Department of Food Science. Illiana Vegetable Growers Symposium March 4 th, 2014

Chlorine, Free and Total, High Range

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Technical Paper 3 Verifying Particle Counter Calibration: Size Verification

HI HI 8633 HI HI 8734 HI

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

ISEmax CAS40D. Technical Information

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

Deionized Water. Latest technology, highest quality, environmentally friendly. Water Technologies

GC005 thru GC600. Wireless Load Cell. Features. Applications. General Description. Load Cell

Kestrel 4500 Pocket Weather Tracker

Heat stress index. Dewpoint. pressure. altitude

OCS 140 / 141 Sensors for Free Chlorine Operating Instructions

DPD Test N Tube Method *

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

36 Dual Fuel Range with Griddle

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

General Purpose Relays Types K, R, N, and C

WEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather

Sicherheit zuverlässig produziert.

JAPAN QUALITY. Automated Clinical Analyzer

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

For Military, Research, Tactical Portable Vehicle Mount Fixed Base

HD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION

Mercury Stack Monitor SM-4

Parameter Method Range # of Tests Code Page. Acidity (as % Oleic acid) titration % acidity 6 HI

Model M3484 Industrial Line Noise Filter Module Customer Reference Manual

Innovative Sustainable Technology

TSC JR 2 Manual SERIES 4B, 5B & 6B

ph / Temperature Meter for Cheese with Application Specific Probe

Transcription:

Clean Water through Innovative Technology NEW!! Instrument Overview Reliable Chlorine Monitoring HF scientific developed the OnLine Residual Chlorine Monitor specifically for drinking water, wastewater and industrial residual chlorine monitoring applications. The OnLine Residual Chlorine M o n i t o r i s m a n u f a c t u r e d u s i n g microprocessor based technology making it the most reliable and cost efficient instrument for monitoring residual chlorine. Colorimetric DPD chemistry technology provides a proven, stable and reliable reading along with the most economical method available. Detailed Specifications Standard Features Proven Colorimetric DPD Chemistry. Free or Total Chlorine. Range of 0-10 ppm. EPA Accepted Method. User Selectable Sample Times. Removable Sample Cuvette. Standard Outputs: 4-20 ma and RS-485 with Modbus. Two User Selectable Alarms.

Features: Features Colorimetric DPD Chemistry Proven reliable and economical, colorimetric DPD (N,N-diethyl-p-phenylenediamine) chemistry is the most accurate method for measuring free or total residual chlorine. Rugged Enclosure The 's small footprint and corrosion resistant NEMA 4X (IP66) enclosure allows for a simple installation that will fit in almost any space. Optical Design New optical design uses similar optics to the hand held portable Chlorine Photometer. The new design increases accuracy and allows for comparable and precise readings between the OnLine Monitor and hand held portable instruments. Removeable Sample Cuvette A removeable sample cuvette allows for simple cleaning and maintenance. Viewable sample chamber allows a clear view of the sample cuvette while the instrument is sampling. Changing the Sample Cuvette Cycle Times User selectable cycle times allow the user to set the cycle time from 90 seconds up to 10 minutes. Low volume reagent and sample chamber allow for affordable reagent costs and decreases water consumption. Certification Listed or Certified to CE, UL, CSA (ETL,ETLc), US EPA Sample Specifications The Residual Chlorine Monitor shall be able to measure free or total chlorine using the DPD colorimetric method. The Chlorine Monitor shall have a measurement range of 0-10 mg/l. The Chlorine Monitor shall include the power supply, sensor and display in one NEMA 4X (IP66) corrosion resistant enclosure. The Chlorine Monitor shall have readings consistent with laboratory and portable Chlorine Photometers. The Chlorine Monitor shall have standard 4-20 ma outputs and RS-485 with Modbus Protocol. The 4-20 ma output shall be standard or reversible. The Chlorine Analyzer shall have a removable sample cuvette. The sensor shall have a clear view to the optical chamber allowing viewing of the sample and reaction of the reagents, before, during and after a reading. Accuracy shall be ± 5% with a resolution of 0.01 mg/l. The Chlorine Monitor shall have a user selectable cycle time between 90 seconds and 10 minutes. The Chlorine Monitor shall be capable of 30 days of unattended operation. The Chlorine Monitor shall take a zero reading before each reading to compensate for color in the sample. The Chlorine Monitor shall have microprocessor based technology. The Monitor shall have two user selectable alarm relays. Changing the Reagents 22

Specifications: Range: 0-10 mg/l. Cycle Time: User Selectable: 90 seconds to 10 minutes. Resolution: 0.01 mg/l Accuracy: ± 5% or 0.03 mg/l of Cl 2 whichever is greater. Method: USEPA accepted DPD method of analysis for measuring Free or Total Residual Chlorine Standard Outputs: 4-20 ma and RS-485 with Modbus. User Alarms: 2 User Selectable Alarms (Form C 240VAC 2A) Operating Temperature: 5 to 40 C (41 to 104 F) Input Pressure: 1-200psi Enclosure: ABS Plastic, NEMA 4X, IP66 Power: 100-240 Volt Auto Switchable 47-63hz Certifications: CE, UL, CSA, (ETL, ETLc) Shipping Dimensions: 16" x 16" x 10" (41cm x 41cm x 26cm) Shipping Weight 8lbs (3.6kg) Specifications subject to change without notice. Ordering Information Catalog No. Description 20040 OnLine Residual Chlorine Monitor for Free or Total Chlorine Complete with Operating Manual. Reagents must be purchased separately. Accessories 09947 Reagent Kit - Free Chlorine 30 day supply 09948 Reagent Kit - Total Chlorine 30 day supply 09935 Reagent Kit - Free Chlorine 60 day supply 09936 Reagent Kit - Total Chlorine 60 day supply 09937 Reagent Kit - Free Chlorine 12 month supply 09938 Reagent Kit - Total Chlorine 12 month supply 09939 Replacement Tubing/Cuvette Kit 24437S Flow Through Cuvette CLX Reagent Kit 3

Dimensions: All Dimensions are in Millimeters (inches). 325.74 (12.82) 311.11 (12.25) 219.05 (8.625) Front View These 4 holes will accept up to 8 MM (5/16 inch) hardware 128.50 (5.06) 298.45 (11.75) Rear View Side View 44

Details: LCD Display Latch Sample Cuvette Backlit - Reaction fully visible even with cover in place Power Alarm Relays Pressure Regulator RS-485 & 4-20 ma Buffer Reagent Bottle Indicator Solution Bottle Inlet Tube 1/4" NPT Drain 1/2 inch I.D. drain tubing with cover removed 3170 Metro Parkway Ft. Myers, FL 33916-7597 Phone: (239) 337-2116 Fax: (239) 332-7643 Email: info@hfscientific.com www.hfscientific.com SOLTECH Ltda. Tecnologías e Ingeniería de Control Calle 76 No. 20B - 24 Of. 302. Bogotá D.C. Tel: +1-347 5141. Fax: +1-347 5170. Cel: 310-570 1837-310-570 1846. E-mail: infotecnica@soltechltda.com www.soltechltda.com 3170 Metro Parkway, Ft. Myers FL 33916 Phone: (239) 337-2116 Fax: (239) 332-7643 Revised 9/27/05 5