Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Similar documents
Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Agilent All Ions MS/MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

MassHunter TOF/QTOF Users Meeting

Rapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Accurate Mass Analysis of Hydraulic Fracturing Waters

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

The new Water Screening PCDL

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

The Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Making Sense of Differences in LCMS Data: Integrated Tools

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

MassHunter Software Overview

Agilent ESI and APCI sources: for polar to non-polar compounds

Multi-residue analysis of pesticides by GC-HRMS

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

Pharmaceutical Impurity Identification and Profiling Using Agilent Q-TOF LC/MS Combined with Advanced MassHunter Data Processing Software

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

László Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Application Note. Abstract. Authors. Environmental

Highly Sensitive and Rugged GC/MS/MS Tool

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Detection of Trace Level Pharmaceuticals in Drinking Water by Online SPE Enrichment with the Agilent 1200 Infinity Series Online-SPE Solution

Application Note. Edgar Naegele. Abstract

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Die Nadel im Heuhaufen

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Guide to Peptide Quantitation. Agilent clinical research

Application Note. Edgar Naegele. Abstract

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

Quantitation of Cystine and Identification of Related Metabolites in White Blood Cells Using a High Resolution Accurate Mass LC/MS Approach

Application Note. Abstract. Authors. Food Safety and Environmental

Computer-assisted analysis of complex natural product extracts

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Fully automated QuEChERS clean-up and LC/MS-QQQ analysis of pesticides in fruits and vegetables.

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

ANALYTICAL REPORT 1 CUMYL-4CN-BINACA (C22H24N4O) 1-(4-cyanobutyl)-N-(1-methyl-1-phenylethyl)-1H-indazole-3-carboxamide

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Theory and Practical Consequences.

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Screening and Verifying Mycotoxins in Food with Q-TOF LC/MS and an Accurate Mass Library

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

C Glucose Qualitative Flux Analysis in HepG2 cells

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Supporting Information

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Transcription:

Screening and Quantitation of 24 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System Application Note Authors Dan-Hui Dorothy Yang, Christian Klein, Crystal Cody, and Huy Bui Agilent Technologies, Inc. Santa Clara, CA 955 Abstract This Application Note describes an UHPLC/Q-TOF/MS method for screening 24 pesticides and pesticide metabolites in diffi cult food matrixes. The method benefi ts from increased chromatographic resolution using the Agilent 29 Infi nity UHPLC System and improved ionization capabilities with an Agilent Jet Stream ionization source. More importantly, the successful screening of analytes is accomplished by the innate sensitivity improvement of the Agilent 6545 Q-TOF LC/MS System and ion transmission tuning to facilitate the optimal ion transmission of small, fragile organic molecules. Targeted MS/MS acquisition was used for analyte quantitation and confi rmation. Black tea matrix was chosen for its complexity, and avocado matrix was chosen to represent food commodities with high lipid content. Our results demonstrate that the improved detection of small organic molecules by the 6545 Q-TOF LC/MS System allows the screening and quantitation of most of the targeted pesticides below the maximum residue limits (MRLs) specifi ed by the European Commission regulations.

Introduction Pesticide residue screening in food products is one of the most important and most demanding applications in food safety. There are more than, pesticides and pesticide metabolites which can be present in food. European Commission regulation (EC) 396/25 and its annexes set maximum residue limits (MRLs) for more than 7, matrix-pesticide combinations. Similar regulations are in place in other regions 2. Accurate mass LC/MS in food safety applications permits the detection of a large number of analytes. This is especially important for some metabolites where chemical standards are hard to obtain, and the development of a triple quadrupole method is rendered difficult. Accurate mass LC/MS method setup is relatively easy and can be accomplished without knowing the retention time or fragmentations. This is especially important for a commercial testing lab to increase the scope of testing and throughput. A typical workflow in accurate mass LC/MS includes the screening and quantitation of regulated pesticide residues by using MS domain data. Mass accuracy, isotopic abundance, isotopic spacing, and adduct pattern are used to verify positives. Quite often, retention time is also considered a critical factor for compound matching. Using a comprehensive personal compound database and library (PCDL) search can disclose a list of likely pesticide residues. The pesticide residues can be further confirmed by auto or targeted MS/MS with the application of appropriate collision energy for fragmentation, and searched against the PCDL. This is of critical importance to rule out potential false positives in the context of complex matrixes such as QuEChERS extracts. The MS/MS information gives a higher level of identification confidence. Most pesticides are analyzed with multiresidue methods covering hundreds of compounds applied to various food commodities. Therefore, fast and reliable analytical methods are required for pesticide identification at low concentrations in a broad range of food matrixes. Criteria for the identification of pesticide residues and requirements for method validation and quality control procedures for quantitation are specified in guidance documents such as SANCO/257/23 3. This Application Note describes the development of an UHPLC/QTOF/MS method for the screening and quantitation of hundreds of pesticides in food samples. The method was developed using the Pesticide Comprehensive Test Mix (p/n 59-55). An Agilent 29 Infinity UHPLC System was coupled to the Agilent 6545 Q-TOF LC/MS System. The acquisition was carried out in positive ion mode. Several modifications associated with the 6545 Q-TOF LC/MS System have resulted in higher analytical performance. Hardware improvements include a new: Slicer design with the option to operate under high sensitivity or high resolution mode High performance high voltage power supply that improves the mass resolution for higher molecular weight entities Enhanced gain shifted detector that provides much longer detector lifetime More importantly, for the first time, Particle Swarm Optimization technology is commerically used to optimize mass spectrometers, resulting in much faster (4x) and more robust tuning of the instrument. The improvements in ion transmission for small molecules also results in mass accuracy enhancement below m/z. A substantial 4x increase in signal response compared with the previous generation of the Agilent 654 Q-TOF LC/MS System is achieved. Experimental Reagents and chemicals All reagents and solvents were HPLC or LC/MS grade. Acetonitrile and methanol were purchased from Honeywell (Morristown, NJ, USA). Ultrapure water was produced using a Milli-Q Integral system equipped with a LC-Pak Polisher and a.22 µm point-of-use membrane filter cartridge (EMD Millipore, Billerica, MA, USA). Formic acid was from Fluka (Sigma-Aldrich Corp., St. Louis, MO, USA) and ammonium formate solution (5 M) was from Agilent (p/n G946-852). Pesticides were included in the Agilent Pesticide Comprehensive Test Mix (p/n 59-55). A ppm amount of pesticides working solution was used for spiking the QuEChERS extracts and preparing the calibration samples. Sample preparation Organic black tea and organic avocado were obtained from a local grocery store. Samples were extracted according to the official citrate-buffered QuEChERS protocol using Agilent BondElut QuEChERS kits (p/n 5982-565) 4. Ten grams of homogenized avocado and 2 g of black tea were weighed into 5-mL polypropylene tubes and extracted with ml acetonitrile for minute while shaking vigorously. The tea samples were wetted with 8 ml ultrapure water for 2 hours prior to extraction. Raw extracts were cleaned up by dispersive SPE with lipid removal for avocado (p/n 5982-558) and with graphitized carbon black (GCB) (p/n 5982-5356H) for black tea. Final extracts were spiked in six relevant concentrations with the pesticides at ng/g, 5 ng/g, ng/g, 2 ng/g, 5 ng/g, and ng/g. The matrix-matched standards were prepared before injection and were measured with five technical replicates at lower concentration levels. 2

Equipment and software Separation was carried out using an Agilent 29 Infinity UHPLC System consisting of: Agilent 29 Infinity Binary Pump (G422A) Agilent 29 Infinity High Performance Autosampler (G4226A) and sample cooler (G33B) Agilent 29 Infinity Thermostatted Column compartment (G36C) The UHPLC system was coupled to an Agilent 6545 Q-TOF LC/MS System equipped with an Agilent Jet Stream electrospray dual ionization source. Agilent MassHunter workstation software was used for data acquisition (B.6., build 6..645), qualitative analysis (B.7., build 7..724.) and quantitative analysis (B.7., build 7..457.). Methods The 29 Infinity UHPLC conditions are summarized in Table. Analysis was carried out with positive ion mode. Three microliters of the final extract were injected. Source parameters are optimized with a subset of 4 pesticides that represents the cohort of 24. The summary of the 6545 Q-TOF LC/MS System parameters are listed in Table 2. Data were evaluated using the MassHunter Qualitative and Quantitative Analysis software. Calibration curves were generated using quadratic fitting, /x weighting, and including the origin. Table. Agilent 29 UHPLC parameters. Parameter Value Column Agilent ZORBAX Eclipse Plus C8 2. 5 mm,.8 µm (p/n 959759-92) Column temperature 45 C Injection volume 3 µl sampler temperature 5 C Needle wash seconds (8 % MEOH/2 % water) Mobile phase MPA: Water, 5 mm NH 4 formate +. % formic acid MPB: MeOH, 5 mm NH 4 formate +. % formic acid Flow rate.4 ml/min Gradient program Time % B 5 5 4 5 7 2 2. 5 Stop time 22 minutes Post time minute Table 2. Agilent 6545 Q-TOF LC/MS System parameters. Parameter Value Mode Positive; 4 GHz High Resolution Tune 5 25 m/z Drying gas temperature 5 C Drying gas flow L/min Sheath gas temperature 375 C Sheath gas flow L/min Nebulizer pressure 35 psi Capillary voltage 3,5 V Nozzle voltage 2 V Fragmentor 25 V Skimmer 45 V Oct RF Vpp 75 V Acq mass range, m/z (MS only) Acq rate 3 spectra/s Ref mass ions 2.5873, 922.9798 3

Results and Discussion New tuning algorithm: particle swarm optimization tune (SWARM tune) An artificial intelligent optimization algorithm that simulates social learning behavior in a bird flock was used to optimize the mass spectrometer with different criteria. Unlike classic Auto Tune, that generates one-size-fits-all optimization, the SWARM tune opens a new chapter for customizable instrument optimization based on application needs. The algorithm provides the possibility to optimize the ion transmission for fragile smaller molecules (for example, 5 25 m/z, and 5 75 m/z) depending on the user selection. In conjunction with the hardware improvement, the optimization dramatically improves signal response for small molecules. Moreover, acetonitrile-sodium adducts can be used as an additional calibrant to improve the mass accuracy in the 5 m/z range under the fragile ions tune. In addition to sensitivity and mass accuracy improvements associated with the 6545 Q-TOF LC/MS System, a substantial increase in tuning and calibration speed can be achieved. Comparing with the classic auto tune on the 654 Q-TOF LC/MS System, the system tuning time was reduced by a factor of four. The new algorithm and methodology also let the system tune TOF and Quad simultaneously under both polarities. Figure shows a new user interface under the tune context. Agilent 6545 Q-TOF LC/MS System performance The changes in hardware and ion transmission tune result in a factor of ~4 signal response improvement by the 6545 Q-TOF LC/MS System compared to the 654 Q-TOF LC/MS System when the high resolution slicer position is chosen. Figure 2 shows the overlay of ppb thiabendazole chromatographs on 6 4.5 4. 3.5 3. 2.5 2..5..5 Quad and TOF can be tuned together.,294,362 3,78,23 a 654 Q-TOF LC/MS System and a 6545 Q-TOF LC/MS System. Thiabendazole has a molecular weight of 2.3, and the optimized ion transmission of the m/z 5 25 range further improved the signal response. In addition to thiabendazole, the other 3 pesticides in this small study demonstrated a similar improvement trend. Figure. User interface under the tune context: the SWARM tune is implemented and defines optimal conditions for ion transmission based on application needs. Agilent 6545 Q-TOF LC/MS System 5 25 m/z Agilent 6545 Q-TOF LC/MS System 5 75 m/z Agilent 654 Accurate Mass Q-TOF LC/MS System.7.8.9 2. 2. 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3. Acquisition time (min) Figure 2. Exemplary chromatogram of signal response of ppb thiabendazole in acetonitrile on an Agilent 654 Q-TOF LC/MS System and an Agilent 6545 Q-TOF LC/MS System. The optimized ion transmission at 5 25 m/z provides further improvement compared with optimized ion transmission at 5 75 m/z for the analyte with m/z 22.3. 4

Similar improvement for a group of 24 pesticides has been observed in black tea and avocado matrixes at ng/g spike concentration, corresponding to 2 ppb and ppb respectively. For compounds that can be detected at these levels, the ratios are taken from the average of five replicates with each instrument. Histograms are shown in Figure 3. The improvement in sensitivity results in more compounds identified by the 6545 Q-TOF LC/MS System than by the 654 Q-TOF LC/MS System. An example of ng/g alanycarb spiked in black tea matrix is shown in Figure 4. The 654 Q-TOF LC/MS System failed to detect the compound. The above results were obtained with a high resolution slicer position. It is expected that another two-fold signal response improvement can be achieved when a high sensitivity slicer position is chosen. No. of compounds No. of compounds 4 2 8 6 4 2 4 2 8 6 4 2 A 2 2x B 2x Black tea: 2 ppb 82 85 3 24 2 3x 3 4x 4 5x 5 6x >6x Area response folds improvement 6 Avocado: ppb 73 7 7 5 2 3x 3 4x 4 5x 5 6x >6x Area response folds improvement Figure 3. Signal response improvements of ~24 pesticides in black tea and avocado matrixes. The area response ratio of Agilent 6545 Q-TOF LC/MS System/Agilent 654 Q-TOF LC/MS System was taking from the average of five replicates for each analyte. Another two-fold signal response improvement is expected when the high sensitivity slicer position is chosen. 3 5 4 3 Agilent 6545 Q-TOF LC/MS System 2.84 min 3.4.2.8.6.4.2 Agilent 654 Q-TOF LC/MS System 2.4.6.8 2 2.22.4 2.6 2.8 3. Acquisition time (min).4.6.8 2. 2.2 2.4 2.6 2.8 3. Acquisition time (min) Figure 4. The Agilent 6545 Q-TOF LC/MS System sensitivity improvement benefits the analyte at the borderline of detection. Alanycarb could be detected by the Agilent 6545 Q-TOF LC/MS System, but not by the Agilent 654 Q-TOF LC/MS System in black tea matrix at ng/g spike level. 5

Compounds identification using Find by Formula (FbF) The PCDL containing all spiked pesticides was generated from Agilent Pesticide PCDL (G3878-63 MassHunter Personal Pesticide Library). The FbF search of analytes in matrixes against the PCDL was conducted, and some parameters settings of FbF algorithm are listed in Table 3. Software automatically generated an extracted ion chromatogram for the expected ion species of the target compounds in the accurate mass database. Peak spectra were extracted and the measured results were compared with calculated results to generate a matching score based on mass accuracy, isotopic abundance, and isotopic spacing 5. Figure 5 shows, as an example, the methidathion chromatogram and peak spectrum in black tea matrix at ng/g spike level, which corresponds to 2 ppb. At such a low concentration, and in one of the most complex matrixes, outstanding signal-to-noise (S/N) ratio can be obtained. Both proton adduct and ammonium adduct give excellent matching scores, with up to 4 5x coeluting background ions from the matrix. Consequently, the overall score for H + adduct is 99.66 out of (mass accuracy 99.8 out of ; isotopic abundance 99.74 out of ; isotopic spacing 99.26 out of ), and the overall score for ammonium adduct is 97.36 out of (mass accuracy 99.29 out of, isotopic abundance 94 out of, isotopic spacing 97.52 out of ). The mass error for major ion species is generally low, resulting in a matching score for most of the analytes > 9 out of. Table 3. Parameter Settings for FbF Data Mining Parameter Extraction data file E5 5 2.5 2..5..5 4.5..5 A 8.5 B H adduct 8.959 E8 8 4 TIC 2 2 8.5 8.7 8.9 9. 9.3 9.5 Acquisition time (min) Value Profile for chromatographic and spectral extraction Charge state Isotopic model Common organic molecule PCDL Subset of G3878CA Adduct [M+H] +, [M+NH 4 ] +, [M+Na] + Mass tolerance 6 ppm RT window.5 minutes Mass accuracy weighting Isotopic abundance weighting 6 Isotopic spacing weighting 5 8.6 8.7 8.8 8.9 9. 9. 9.2 9.3 9.4 9.5 Acquisition time (min) NH 4 adduct 34 36 38 3 32 34 36 38 32 322 Mass-to-charge (m/z) Figure 5. Compound chromatograph and peak spectrum by FbF algorithm for methidathion spiked into a QuEChERS extract of black tea at ng/g. The identification of the compound with high confidence can be achieved even with 4 5x coeluting background ions. 6

The MS domain data can be used to obtain quantitative information for the spiked pesticides. The best ions for the quantitative method are derived from the compound results extracted from the MassHunter Qualitative Analysis Software using 2 ppb pesticides in neat solvent. The results are exported as a compound exchange file (.cef) that is used in quantitative analysis. Quantifier and qualifier are automatically selected from the observed adduct species and isotopic signals based on their relative abundance. All pesticides could be detected at ng/g spike concentration in avocado matrix except propagite, which could not be detected in neat solvent at higher concentration, possibly due to degradation. We did not detect 2 compounds at ng/g in black tea matrix due to the combination of 5x lower concentration and severe matrix effect. However, the improved sensitivity of the 6545 Q-TOF LC/MS System still achieved ~7 % analyte detection at a ng/g spike level in black tea matrix, corresponding to.2 ppb. The number of the compounds detected at different spike concentrations is shown in Figure 6. No. of compounds detected 25 23 2 9 7 5 67 228 2 237 22 239 239 232 237 239 238 239 ng/g 5 ng/g ng/g 2 ng/g 5 ng/g ng/g Black tea Avocado Figure 6. Number of the compound detected at each spike concentration in black tea and avocado matrixes. The improvement in sensitivity of the Agilent 6545 Q-TOF LC/MS System results in more compounds to be detected. 7

Quantitation and confirmation with targeted MS/MS Targeted MS/MS is an important feature in data acquisition for analyte quantitation as well as for structure confirmation by comparing the fragmentation pattern against the database and library. Knowledge of the retention time of a particular ion species is required to set up the acquisition method. The retention times were retrieved from MS domain data that could be extracted from Agilent MassHunter Qualitative Analysis Software. Retention time window (delta RT) was set to minute. Reference ions were excluded for the MS/MS spectrum. Acquisition rates were 5 spectra/s for MS and 2 spectra/s for MS/MS. Collision energy was set as a linear regression of 4 + 6 mass/, depending on the molecular weight of the target ions. As a result, a search filter on collision energy of ± 2 ev was applied to focus comparison of measured spectra to those library entries of similar collision energy. Most compounds were confirmed and quantified at or below the MRL in black tea matrix with reverse matching. Most of the compounds detected on MS domain could be detected by targeted MS/MS. Figure 7 shows a calibration curve and library match at ng/g spike level of metobromuron in black tea matrix (top) and dimethoate in avocado matrix (bottom). It is expected that the measure MS/MS spectrum in the presence of matrix can be noisier than the library spectrum often acquired in neat solvent at relatively higher concentration. In MassHunter Quantitative Analysis, users can either set up the reference library with PCDL, or use the standards in neat solvent under the same LC/MS conditions through the compound exchange file. Responses 5 2.5 2..5..5 Metobromuron y = 7.3234x 2 + 3583.5249x + 297.353 R 2 =.996254 A 2 3 4 5 6 7 8 9 Concentration (ng/ml) 3..5 -.5 -. -.5 + Product ion (8.35 8.227 min, 3 scans) (259.77 & **) Black tea 26.34 B 9.48 7.9585 23.563 259.77 62.6 48.63 259.77 2 4 6 8 2 4 6 8 2 22 24 26 Mass-to-charge (m/z) Responses 5 3. 2.5 2..5..5 Dimethoate y = 5.2325x 2 + 4742.7638x + 247.3263 R 2 =.99865988 C 2 3 4 5 6 7 8 9 Concentration (ng/ml) 3..75.5.25 -.25 -.5 -.75 -. -.25 + Product ion (5.42 5.55 min, 2 scans) (23.76 & **) Avocado 24.98 D 88.23 7.969 42.9923 98.9634 88.25 24.982 7.9698 98.9647 2 4 6 8 2 4 6 8 2 22 Mass-to-charge (m/z) Figure 7. Targeted MS/MS can be used to quantify pesticides as well as confirm its structure by fragments comparing with PCDL spectrum. Most of the compounds detected on MS domain could be quantified by targeted MS/MS. A ng/g spike of metobromuron in black tea (top) and dimethoate in avocado (bottom) are shown as examples. 8

Structure confirmation with Auto MS/MS Auto MS/MS is a feature frequently used for untargeted analysis. In pesticide screening, to eliminate false positives in complex matrixes such as black tea and avocado, further structure confirmation is needed. The confirmation is conducted by comparing the measured MS/MS spectrum to the library spectrum. Caution should be taken when seting up auto MS/MS methods. Sometimes, a preferred ion list is required to overcome matrix interference and obtain meaningful MS/MS spectra. Ion species and associated retention times can be imported from MassHunter Qualitative Analysis on MS domain data. The advantage of auto MS/MS over targeted MS/MS is that the data mining can be performed retrospectively should the library be updated with more analytes for their presence in the samples. The acquisition typically lasts only 2 3 cycles for more compound coverage. Thus, auto MS/MS is not recommended for analyte quantitation. Two examples are shown in Figure 8 on the stucture confirmation for chlorfevinphos (II) in black tea and diethofencarb in avocado at ng/g spike concentration. 2..5 2-2..5 2..5 2-2..5 Compound 7 A 98.984 27.5 55.458 26.9332 Compound 7 98.984 27.555.458 26.9332 Chlorfenvinphos(II) 98.9843 27.55 55.468 8.9738 6 8 2 4 6 8 2 22 24 26 28 Mass-to-charge (m/z) Compound 53 B 95.27 24.393 Compound 53 95.27 24.393 Diethofencarb 8.444 24.393 52.7 8.26 98.768 52.7 8.26 98.768 52.76 26.937 8.9 98.76 8 9 2 3 4 5 6 7 8 9 2 2 22 Mass-to-charge (m/z) Figure 8. Auto MS/MS is useful for structure confirmation by the comparison of the measured spectrum and library spectrum. The examples show ng/g chlorfevinphos (II) in black tea (A) and ng/g diethofencarb in avocado (B). 9

Conclusions The Agilent 6545 Q-TOF LC/MS System is a valuable addition to the product family for the applied market with its improvement in sensitivity and ion transmission tune for fragile organic molecules. We have demonstrated that most of the pesticides and pesticide metabolites can be detected well below the MRL in complex matrixes. The method can easily be extended for more analyte screening and quantitation. This can potentially allow laboratories to increase their testing scale and throughput. The Agilent total solution, from comprehensive reagent kit, UHPLC/MS, PCDL, and MassHunter Qualitative/Quantitative Analysis Software, has allowed us to facilitate method development and validation for the end users. References. Regulation (EC) No 396/25 of the European Parliament and of the Council of 23 February 25 on maximum residue levels of pesticides in or on food and feed of plant and animal origin (including amendments as of 8 March 28) and complying with regulation (EC) 7/29. 2. US Regulation 4 CRF part 8 Tolerance Information for Pesticide Chemicals in Food and Feed Commodities. 3. Guidance document on analytical quality control and validation procedures for pesticide residues analysis in food and feed. Document N SANCO/257/23. Implemented by //24.http://www.eurlpesticides.eu/library/docs/allcrl/ AqcGuidance_Sanco_23_257.pdf 4. Zhao, L; Stevens, J. Analysis of Pesticides Residues in Spinach Using Agilent SampliQ QuEChERS lit by LC/MS/MS Detection, Agilent Technologies Application Note, publication number 599-4248EN, 22. 5. Kempe, G; Spitzbarth, F; Glauner, T. Development and Application of an Exact Mass LC/MS/MS Library for the Accurate Mass Screening and Quantitation of Pesticides in Fruits and Vegetables, Agilent Technologies Application Note, publication number 599-2227EN, 23. www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc., 25 Published in the USA, January 23, 25 599-5485EN