arxiv: v1 [astro-ph.he] 25 Mar 2015

Similar documents
Depth of maximum of air-shower profiles at the Pierre Auger Observatory: Measurements above ev and Composition Implications

PoS(ICRC2017)522. Testing the agreement between the X max distributions measured by the Pierre Auger and Telescope Array Observatories

Studies on UHECR composition and hadronic interactions by the Pierre Auger Observatory

On the Combined Analysis of Muon Shower Size and Depth of Shower Maximum

Measurement of air shower maxima and p-air cross section with the Telescope Array

arxiv: v1 [astro-ph.he] 7 Mar 2018

arxiv: v1 [astro-ph.he] 1 Oct 2018

The average longitudinal air shower profile: exploring the shape information

Experimental Constraints to High Energy Hadronic Interaction Models using the Pierre Auger Observatory Part II

Measurement of the cosmic ray spectrum and chemical composition in the ev energy range

Parameters Sensitive to the Mass Composition of Cosmic Rays and Their Application at the Pierre Auger Observatory

Zero degree neutron energy spectra measured by LHCf at s = 13 TeV proton-proton collision

The cosmic ray energy spectrum measured using the Pierre Auger Observatory

Neutral particles energy spectra for 900 GeV and 7 TeV p-p collisions, measured by the LHCf experiment

Recent measurements of ultra-high energy cosmic rays and their impact on hadronic interaction modeling

Mass Composition Study at the Pierre Auger Observatory

Latest results and perspectives of the KASCADE-Grande EAS facility

Cosmic Ray Interaction Models: an Overview

OVERVIEW OF THE RESULTS

The High Resolution Fly s Eye (HiRes) Experiment. John N. Matthews University of Utah

PoS(ICRC2015)424. YAC sensitivity for measuring the light-component spectrum of primary cosmic rays at the knee energies

Probing QCD approach to thermal equilibrium with ultrahigh energy cosmic rays

The air-shower experiment KASCADE-Grande

Studies of Ultra High Energy Cosmic Rays with the Pierre Auger Observatory

Results from the Telescope Array Experiment

Ultra-High-Energy Cosmic Rays: A Tale of Two Observatories

UHE Cosmic Rays and Neutrinos with the Pierre Auger Observatory

Search for ultra-high Energy Photons with the Pierre Auger Observatory

P. Tinyakov 1,2 TELESCOPE ARRAY: LATEST RESULTS. P. Tinyakov. for the Telescope Array Collaboration. Telescope Array detector.

The Pierre Auger Observatory in 2007

Constraints on the energy spectra of charged particles predicted in some model interactions of hadrons with help of the atmospheric muon flux

The influence of the observatory latitude on the study of ultra high energy cosmic rays

Extensive Air Shower and cosmic ray physics above ev. M. Bertaina Univ. Torino & INFN

P. Tinyakov 1 TELESCOPE ARRAY: LATEST RESULTS. P. Tinyakov. for the Telescope Array Collaboration. Telescope Array detector. Spectrum.

arxiv: v2 [astro-ph.im] 24 Nov 2009

Search for EeV Protons of Galactic Origin

arxiv: v1 [hep-ph] 19 Nov 2018

ULTRA-HIGH ENERGY COSMIC RAY COMPOSITION and MUON CONTENT vs. HADRONIC MODELS. Esteban Roulet Bariloche, Argentina

A CORSIKA study on the influence of muon detector thresholds on the separability of primary cosmic rays at highest energies

The Pierre Auger Observatory Status - First Results - Plans

Cosmic ray studies at the Yakutsk EAS array: energy spectrum and mass composition

Numerical study of the electron lateral distribution in atmospheric showers of high energy cosmic rays

arxiv: v1 [astro-ph.he] 8 Apr 2015

ULTRA HIGH ENERGY COSMIC RAYS WHERE DO WE STAND AFTER 10 YEARS AT THE PIERRE AUGER OBSERVATORY

arxiv:astro-ph/ v2 24 May 2007

Average value of available measurements of the absolute air-fluorescence yield

PoS(ICRC2015)349. TA Spectrum Summary

The KASCADE-Grande Experiment

KASCADE-Grande energy spectrum of cosmic rays interpreted with post-lhc hadronic interaction models

Recent Results from the KASCADE-Grande Data Analysis

Recent Results of the Telescope Array Experiment. Gordon Thomson University of Utah

Status and results from the Pierre Auger Observatory

ON THE WAY TO THE DETERMINATION OF THE COSMIC RAY MASS COMPOSITION BY THE PIERRE AUGER FLUORESCENCE DETECTOR: THE MINIMUM MOMENTUM METHOD

arxiv: v1 [astro-ph.he] 28 Jan 2013

Correlation between the UHECRs measured by the Pierre Auger Observatory and Telescope Array and neutrino candidate events from IceCube

On the measurement of the proton-air cross section using air shower data

Analytic description of the radio emission of air showers based on its emission mechanisms

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

Energy Spectrum of Ultra-High-Energy Cosmic Rays Measured by The Telescope Array

Anisotropy studies with the Pierre Auger Observatory

Hadronic Interaction Models and Accelerator Data

Investigation on mass composition of UHE cosmic rays using CRPropa 2.0

Cosmic Ray Physics with the IceTop Air Shower Array. Hermann Kolanoski Humboldt-Universität zu Berlin

HiRes Composition. John Belz, University of Utah Nuclear Interactions Workshop University of Washington 20 February 2008

Hadronic Interaction Studies with ARGO-YBJ

arxiv: v2 [astro-ph.he] 17 Oct 2016

Longitudinal profile of Nµ/Ne in extensive air showers: Implications for cosmic rays mass composition study

Ultrahigh Energy cosmic rays II

Cosmic Ray Physics with the IceTop Air Shower Array. Hermann Kolanoski Humboldt-Universität zu Berlin

Experimental Constraints to high energy hadronic interaction models using the Pierre Auger Observatory part-i

Cosmic Rays in large air-shower detectors

Hadronic Interactions and Cosmic Ray Physics

arxiv: v1 [astro-ph.he] 22 Aug 2014

Science case for recording protonoxygen collisions at the LHC

pa at the LHC and Extensive Air Shower Development

Short review and prospects of radio detection of high-energy cosmic rays. Andreas Haungs

The optimum distance at which to determine the size of a giant air shower

arxiv: v1 [astro-ph] 30 Jul 2008

Study of the arrival directions of ultra-high-energy cosmic rays detected by the Pierre Auger Observatory

Air Shower Measurements from PeV to EeV

Search for ultra-high energy photons and neutrinos at the Pierre Auger Observatory

Study of Number of photons at axis Shower with different de/dx and Fluorescence Yield

Recent Results from CANGAROO

PoS(ICRC2015)657. Telescope Array extension: TA 4

UHE Cosmic Rays in the Auger Era

arxiv: v1 [astro-ph.he] 31 Dec 2018

PoS(LeptonPhoton2015)043

Kathrin Egberts Max-Planck-Institut für Kernphysik, Heidelberg for the H.E.S.S. Collaboration

arxiv: v1 [hep-ph] 17 Dec 2018

Status KASCADE-Grande. April 2007 Aspen workshop on cosmic ray physics Andreas Haungs 1

PoS(ICRC2015)432. Simulation Study On High Energy Electron and Gamma-ray Detection With the Newly Upgraded Tibet ASgamma Experiment

THE PIERRE AUGER OBSERVATORY: STATUS AND RECENT RESULTS

The AUGER Experiment. D. Martello Department of Physics University of Salento & INFN Lecce. D. Martello Dep. of Physics Univ. of Salento & INFN LECCE

arxiv: v1 [astro-ph.he] 15 Oct 2018

The FRAM Telescope at the Pierre Auger Observatory

First indication of LPM effect in LHCf, an LHC experiment

arxiv: v1 [astro-ph.he] 14 Jul 2017

Mass composition studies around the knee with the Tunka-133 array. Epimakhov Sergey for the Tunka-133 collaboration

Review of LHCb results on MPI, soft QCD and diffraction

Study of high muon multiplicity cosmic-ray events with ALICE at the CERN Large Hadron Collider

Transcription:

arxiv:1503.07540v1 [astro-ph.he 5 Mar 015 Report of the Working Group on the Composition of Ultra High Energy Cosmic Rays R. Abbasi 1, J. Bellido, J. Belz 1, V. de Souza 3, W. Hanlon 1, D. Ikeda 4, J.P. Lundquist 1, P. Sokolsky 1, T. Stroman 1, Y. Tameda 5, Y. Tsunesada 6, M. Unger 7,8, A. Yushkov 9 for the Pierre Auger Collaboration and the Telescope Array Collaboration 11 1 Department of Physics and Astronomy, University of Utah, 115 South 1400 East, Salt Lake City 8411, U.S.A. University of Adelaide, Adelaide, S.A., Australia 3 Instituto de Física de São Carlos, Universidade de São Paulo, São Carlos, Brasil 4 Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba, Japan 5 Faculty of Engineering, Kanagawa University, Yokohama, Kanagawa, Japan 6 Graduate School of Science and Engineering, Tokyo Institute of Technology, Meguro, Tokyo, Japan 7 Center for Cosmology and Particle Physics, New York University, 4 Washington Place, New York, NY 003 8 Institut für Kernphysik, Karlsruher Institut für Technologie, Postfach 3640, 7601 Karlsruhe, Germany 9 Institut für Physik, Universität Siegen, Walter-Flex-Str. 3, 57068 Siegen, Germany http://www.auger.org/archive/authors_014_.html 11 http://www.telescopearray.org/index.php/research/collaborators E-mail: jose.bellidocaceres@adelaide.edu.au, belz@cosmic.utah.edu For the first time a proper comparison of the average depth of shower maximum (X max ) published by the Pierre Auger and Telescope Array Observatories is presented. The X max distributions measured by the Pierre Auger Observatory were fit using simulated events initiated by four primaries (proton, helium, nitrogen and iron). The primary abundances which best describe the Auger data were simulated through the Telescope Array (TA) Middle Drum (MD) fluorescence and surface detector array. The simulated events were analyzed by the TA Collaboration using the same procedure as applied to their data. The result is a simulated version of the Auger data as it would be observed by TA. This analysis allows a direct comparison of the evolution of X max with energy of both data sets. The X max measured by TA-MD is consistent with a preliminary simulation of the Auger data through the TA detector and the average difference between the two data sets was found to be (.9±.7 (stat.)±18 (syst.)) g/cm. KEYWORDS: UHECR 014, cosmic rays, air shower, composition 1. Introduction Composition is a central key to understand the origin of ultra-high energy cosmic rays. Large efforts in developing new detectors and analysis procedures have been made recently in order to improve our knowledge about the abundance of particles arriving at Earth. At the highest energies (E> 18 ev) the depth of shower maximum (X max ) is one of the most robust observables available to infer the composition. Currently, the Pierre Auger and the Telescope Array observatories measure 1

Xmax [g/cm 850 data±σ stat ± σ sys proton iron <X max > [gm/cm 850 Proton Iron Data QGSJETII 03 QGSJET 01c SYBILL.1 650 EPOS-LHC Sibyll.1 QGSJetII-04 18 19 0 E [ev 650 18.5 19 19.5 0 Energy log (E/eV) Fig. 1. X max as measured by the Pierre Auger (left) and Telescope Array (right) Collaboration [, 3. The colored lines denote predictions of air shower simulation (note that different models are shown in the left and right panel, only Sibyll.1 is the same). The black line on the right panel is a straight-line fit to the TA data. X max using fluorescence detectors. Despite the use of the same detection principle, a direct comparison of the data published by both collaborations is not straightforward. The TA Collaboration publishes X max values obtained from distributions folded with detector resolution and efficiency. The interpretation of the data is made possible by the publication of the Monte-Carlo prediction for proton and iron nuclei also folded with detector resolution and efficiency (Fig. 1, right). In the Auger Collaboration only certain shower geometries are selected for sampling almost unbiased X max distributions. The corresponding X max values are presented in the left panel of Fig. 1. In the Auger analysis, each selected geometry allows a wide enough range of X max values to be observed within the fluorescence detector field of view boundaries. We will refer to this event selection as fiducial selection. Besides that, the Auger Collaboration publishedσ(x max ) with detector resolution unfolded. This procedure allows the interpretation of the data (i.e. X max andσ(x max )) using Monte Carlo predictions without the need to fold the detector properties into the predictions. The advantage of the TA analysis is that it does not require removing as many events, since this technique does not apply a fiducial selection. The work reported here is a common effort of the Auger and TA Collaborations with the aim to provide the cosmic ray community a direct comparison of the X max measurements taking into account the different approaches of each collaboration. Indirect comparisons of TA and Auger results were published in the first report of these series [1. The disadvantage of indirect comparisons is that they depend on the particular hadronic interaction model that is used. The current analysis was performed in the following way. The Auger X max distributions were fitted by a combination of four primary nuclei (proton, helium, nitrogen, iron) using events from air shower simulations. The abundances which best fit the Auger data were simulated through the TA-MD detector and analyzed by the TA Collaboration using the same procedure as applied to their data. This procedure resulted in the Auger data folded into the TA-MD detector. The Auger X max folded with TA-MD analysis is shown in this paper in comparison to the TA-MD data as it is usually published.

Auger 014 (8 yr) 00 TA MD 014 (5 yr) events 0 ratio Auger/TA 1 30 0 4 18 18.5 19 19.5 0 Fig.. Number of selected events for the Auger (solid red line) and TA (blue dashed line) analyses. The ratio of events is given in the lower panel.. Data Samples The analysis presented here is based on the data measured by the Pierre Auger Observatory in the period from the 1st of December 004 until 31st of December 01. All measured events were analyzed as explained in reference [. The events were selected in order to guarantee good measurement conditions and a high-quality reconstruction. After that, the fiducial selection was applied. In total 19,947 events were considered for further analysis. The X max values of these events were sampled in 18 energy bins starting at log (E/ ev) = 17.8. From the Telescope Array we use hybrid data collected with the MD fluorescence telescope and surface detector array over the period from the 7th of May 008 to the nd of May 013. The reconstruction and analysis applied to the data is described in [3. The number of events which passed all cuts is 438, for which the mean X max is shown in 1 energy bins above log (E/eV)=18.. The number of events used for this comparison presented here is shown in Fig. and the X max - resolution of the two experiments is presented in Fig. 3. As can be seen, the resolutions after cuts are comparable but it is worthwhile noting that the resolution quoted for the MD does not contain effects from the detector calibration and atmospheric monitoring. The systematic uncertainties on the X max scale are compared in the right panel of Fig. 3 and they are g/cm and 16 g/cm for the Auger and TA analyses respectively. 3. Analysis Due to the different analysis approaches of the TA and Pierre Auger Collaborations it is not possible to compare the published values of X max andσ(x max ) directly. Whereas the moments of 3

resolution [g/cm X max 40 35 30 5 0 15 5 0 TA MD σ(x Auger σ(x Auger total gen ) gen - X max - X max ) 18 18.5 19 19.5 0 rec max rec max syst. uncert. of X max [g/cm 0 0 - -0-30 Auger: analysis reconstruction total atmosphere calibration TA(MD) total 18 18.5 19 19.5 0 Fig. 3. X max resolution (left) and systematics of the X max scale (right) for the Auger and TA analyses. [g/cm 790 780 data fraction fit ) [g/cm 80 70 X max 770 760 max σ(x 60 50 740 40 730 70 30 7 18 19 0 E [ev 0 18 19 0 E [ev Fig. 4. Moments of the fitted X max distributions using QGSJetII-03 (black markers) and X max moments measured by the Pierre Auger Collaboration (red circles with statistical error bars), see text. the X max distribution published by the Pierre Auger Collaboration are close to the true moments (moments of f true in Eq. (1)), the TA collaboration published the X max folded with the effects of the detector response and reconstruction (moments of f obs in Eq. (1)). The relation between the true and observed X max distribution is f obs (Xmax rec )= f true (X max )ε(x max ) R(Xmax rec X max) dx max, (1) 0 i.e., the true distribution f true is deformed by the detection efficiencyεand smeared by the detector 4

resolution R that relates the true X max to the reconstructed one, X rec max. To be able to perform nevertheless a comparison of the two results, we need to establish what X max obs would look like in the TA detector given the X max distribution measured by Auger. For this purpose, we convolute a parametric description of f true that is based on the Auger data with the TA detector simulation and apply the same reconstruction and analysis chain used for the TA data to this simulated data set (see [5 for a previous description of this method). Technically, the parametric description of the X max distribution is realized by providing a set of composition fractions as a function of energy that describe the X max distributions measured by Auger. These fractions are obtained as described in [4 by a log-likelihood fit of templates of X max distributions for different nuclear primaries as predicted by air shower simulations using a particular hadronic interaction model. It is worthwhile noting that the detector acceptance and resolution at a given primary energy depend mainly on X max itself and only weakly on the primary particle type or hadronic interaction model via the invisible energy. Therefore, for the analysis presented here, it is only important that the resulting composition mix describes the data well and not which fractions of primaries are needed or which hadronic interaction model is used to obtain the model of the true X max distribution. Here we used QGSJetII-03 [6 and a mix of four primary particles (proton, helium, nitrogen and iron) to obtain a model of true X max distribution based on the Auger data. QGSJetII-03 is not included in the set of models studied by the Pierre Auger Collaboration to infer the primary composition [4 because it gives a worse description of LHC data than the re-tuned version QGSJetII-04 [7. However, with neither version of QGSJetII it is possible to find a composition mix that gives a perfect description of the X max distributions measured by Auger. The first two moments of the best fits with QGSJetII-03 and the Auger data are shown in Fig. 4. As can be seen, there is a good agreement regarding X max, but there are deviations between the fitted and observed width of the distribution. Ideally, this analysis should be performed with a combination of composition and hadronic interaction model that fits the Auger data well, such as Sibyll.1 [8 or Epos-LHC [9 (see discussion in [4). However, due to the lack of large air shower libraries other than QGSJetII-03 within the TA Collaboration, we performed the analysis with this model for practical reasons. Since the deviations between the moments of the data and the ones of the fitted distributions are on average at the 5 g/cm level, this approach is expected to give only a small bias in the predicted observed distributions. In detail, the analysis proceeds as follows: the composition mix is processed using the Telescope Array hybrid reconstruction analysis software. Showers are generated by CORSIKA and the trigger response of the surface detector is simulated. The generated longitudinal shower profile is fitted to a Gaisser-Hillas function to determine the shower parameters and a profile based on these parameters is generated. The TA fluorescence detector response including atmospheric, electronics, and geometrical acceptance is then simulated. Subsequently the event geometry is fitted via the fluorescence profile and the shower-detector plane is measured. A fit to hybrid shower geometry is performed which combines the timing and geometric center of charge of the surface detector array, with the timing and geometry of the fluorescence detector that observed the event. This step is what makes the event a hybrid event. If either the surface or fluorescence detector fail to trigger in an event, it is not processed any further, otherwise the shower profile is fitted via a reverse Monte Carlo method where the atmosphere, electronics, and geometrical acceptance of the shower are fully simulated. The resulting effect of the folding of protons and the parametric Auger distributions with the TA detector response, reconstruction and analysis on the X max of Auger is shown in Fig. 5. As can be seen, the observed mean is smaller than the unbiased mean. 5

790 780 Auger 014 unbiased Auger 014 TA MD X max [g/cm 770 760 740 730 70 7 18 18.5 19 19.5 0 Fig. 5. Effect of the MD detector acceptance on X max. The X max of an X max distribution describing the Auger data before and after the MD acceptance are shown as solid squares and circles respectively. The error bars denote the statistical uncertainties of the Auger result in case of the squares and the statistical uncertainties due to the limited MC statistics in the case of the circles. 4. Results and Discussion The X max as measured by TA using the MD fluorescence telescope and the Auger result folded with the TA acceptance are shown in Fig. 6. Their compatibility is quantified with a bin-by-bin comparison excluding the highest-energy data point of each experiment which are at different energies. Using only the statistical uncertainties yields aχ /Ndf of.7/11 with P(χ.7 11)=0.47. The average difference of the data points is (.9±.7 (stat.)±18 (syst.)) g/cm with aχ /Ndf of 9.5/ (P=0.48). It can be concluded that the two data sets are in excellent agreement, even without accounting for the respective systematic uncertainties on the X max scale. However, in the present study we did not take into account a possible difference in the energy scale of the two experiments. The comparison of the energy spectra at the ankle region suggests that the energy scale of TA is about 13% higher than the one of the Pierre Auger Observatory [. But since the elongation rate of the folded Auger data is small ( 19 g/cm /decade), the effect of such an energy shift on the comparison is expected to be at the level of a few g/cm. For a more precise evaluation it is required to take into account the energy dependence of the acceptance of TA. Nevertheless, it is to be expected that the increased difference between the two data sets once the energy scale shift is taken into account will be much smaller than the systematic uncertainties on the X max scale of g/cm and 16 g/cm for the Auger and TA analyses respectively. 5. Conclusions In this paper we presented a comparison between the data on X max as measured by the Pierre Auger and Telescope Array Collaborations. An adequate comparison was achieved by taking into 6

80 TA MD 014 Auger 014 TA MD preliminary X max [g/cm 780 760 740 70 18. 18.4 18.6 18.8 19 19. 19.4 19.6 19.8 0 Fig. 6. Comparison of X max as measured with the MD of TA (blue squares) and the X max of the Auger data folded with the MD acceptance. The data points were slightly shifted horizontally for better visibility. In the case of the Auger points (red circles), the inner error bars denote the statistical uncertainty of the measurement and the total error bar also includes contributions from the limited statistics of simulated events used for the folding. The colored bands show the systematic uncertainties of the X max scales of each experiment. account that the X max published by Auger is corrected for detector effects, whereas the X max published by TA includes detector effects. In the future, we intend to improve the parametric description of the Auger X max distributions and the evaluation of the effect of the relative energy scale uncertainty. Nevertheless, from the preliminary comparison presented here we conclude that the data of the two observatories are in good agreement. References [1 E. Barcikowski et al. for the Pierre Auger, Telescope Array and Yakutsk Collaborations, EPJ Web Conf. 53, 006 (013) [ A. Aab et al. [Pierre Auger Collaboration, Phys. Rev. D 90, no. 1, 1005 (014) [3 R.U. Abbasi et al. [Telescope Array Collaboration, Astropart. Phys. 64, 49 (014) [4 A. Aab et al. [Pierre Auger Collaboration, Phys. Rev. D 90, no. 1, 1006 (014) [5 W.F. Hanlon for the Telescope Array and Pierre Auger Collaborations, Proc. 33rd ICRC, arxiv:13.0647 [astro-ph.he. [6 S. Ostapchenko, Phys. Rev. D 83, 014018 (011) [7 S. Ostapchenko, EPJ Web Conf. 5, 0001 (013) [8 E. J. Ahn, R. Engel, T. K. Gaisser, P. Lipari and T. Stanev, Phys. Rev. D 80, 094003 (009) [9 T. Pierog, I. Karpenko, J. M. Katzy, E. Yatsenko and K. Werner, arxiv:1306.011 [hep-ph. [ D. Ikeda et al. for the Telescope Array and Pierre Auger Collaborations, these proceedings. 7