ATLAS Tile Calorimeter performance for single particles in beam tests

Similar documents
Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2

ATLAS Tile Calorimeter Calibration and Monitoring Systems

Simulation and validation of the ATLAS Tile Calorimeter response

Validation of Geant4 Physics Models Using Collision Data from the LHC

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

ATLAS NOTE October 12, 2009

Available online at Physics Procedia 37 (2012 )

arxiv:hep-ex/ v1 7 Oct 1999

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

Electronic calibration of the ATLAS LAr calorimeter and commissioning with cosmic muon signals

5 Hadronic calorimetry

Granularity of ATLAS Tile Calorimeter studied through simulations

Future prospects for the measurement of direct photons at the LHC

ATLAS Hadronic Calorimeters 101

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

Overview of validations at LHC

CALICE scintillator HCAL

Muon reconstruction performance in ATLAS at Run-2

Studies of the ATLAS hadronic Calorimeter response to muons at Test Beams

Digital Imaging Calorimetry for Precision Electromagnetic and Hadronic Interaction Measurements

Correction for PMT temperature dependence of the LHCf calorimeters

CALICE Test Beam Data and Hadronic Shower Models

First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

Status of ATLAS and Preparation for the Pb-Pb Run

Non-collision Background Monitoring Using the Semi-Conductor Tracker of ATLAS at LHC

CALICE Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006

PERFORMANCE OF THE ATLAS MUON TRIGGER IN RUN 2

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

Status of the physics validation studies using Geant4 in ATLAS

Measurement of the associated production of direct photons and jets with the Atlas experiment at LHC. Michele Cascella

Performance of muon and tau identification at ATLAS

Dual readout with tiles for calorimetry.

Extending the Calibration of the ATLAS Hadronic Calorimeter to High P t Chris Sears, University of Chicago May 16 th, 2002 Advisor: James Pilcher

Study of TileCal Sampling Fraction for Improvement of Monte-Carlo Data Reconstruction

arxiv: v2 [nucl-ex] 6 Oct 2008

G. Gaudio, M. Livan The Art of Calorimetry Lecture V. The state of art Towards ILC calorimetry

CMS ECAL status and performance with the first LHC collisions

Conference Report Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Luminosity determination in pp collisions using the ATLAS detector at the LHC

arxiv: v2 [physics.ins-det] 19 Nov 2010

First Stage Analysis of the Energy response and resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

Results from combined CMS-TOTEM data

Combined Calorimeters Properties Part 1.

GEANT4 simulation of the testbeam set-up for the ALFA detector

Upgrade of the CMS Forward Calorimetry

Analysis results of the rst combined test of the LArgon and. TILECAL barrel calorimeter prototypes. M. Cavalli- Sforza, I. Efthymiopoulos, F.

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning Ph. Schwemling on behalf of the ATLAS LAr Group

Calibration of the CMS Electromagnetic Calorimeter with first LHC data

Calibration of the BABAR CsI (Tl) calorimeter

arxiv: v1 [physics.ins-det] 3 Dec 2018 Fast Interaction Trigger for the upgrade of the ALICE experiment at CERN: design and performance

ATLAS NOTE. August 25, Electron Identification Studies for the Level 1 Trigger Upgrade. Abstract

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Commissioning and Calibration of the Zero Degree Calorimeters for the ALICE experiment

Hadronic Calorimetry

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

ATLAS jet and missing energy reconstruction, calibration and performance in LHC Run-2

Measurement of the neutron fraction event-byevent

The ATLAS trigger - commissioning with cosmic rays

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

Hadron Calorimetry at the LHC

Total, elastic and inelastic p-p cross sections at the LHC

The Fast Interaction Trigger Upgrade for ALICE

2 ATLAS operations and data taking

Hadronic energy reconstruction in the combined electromagnetic and hadronic calorimeter system of the CALICE Collaboration

ATL-LARG Jan 1999

The ALICE Inner Tracking System Off-line Software

Jet Energy Calibration. Beate Heinemann University of Liverpool

Tracking properties of the ATLAS Transition Radiation Tracker (TRT)

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

FoCal Project in ALICE. Yota Kawamura for the ALICE FoCal collaboration TCHoU workshop 2018/3/15

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. First Physics at CMS

The ATLAS muon and tau triggers

LHCb: From the detector to the first physics results

New Results from the DREAM project

October 4, :33 ws-rv9x6 Book Title main page 1. Chapter 1. Measurement of Minimum Bias Observables with ATLAS

Performance of the CMS electromagnetic calorimeter during the LHC Run II

Construction of the CALICE High Granular Scintillator Based Electromagnetic Calorimeter Prototype and Its Response to Electrons

CMS Simulation Software

Digital Calorimetry for Future Linear Colliders. Tony Price University of Birmingham University of Birmingham PPE Seminar 13 th November 2013

Simulation study of scintillatorbased

Hadronic Calorimetry

Information about the T9 beam line and experimental facilities

Reconstruction in Collider Experiments (Part IV)

arxiv: v2 [physics.ins-det] 20 Jun 2007

Physics at Hadron Colliders

Zero degree neutron energy spectra measured by LHCf at s = 13 TeV proton-proton collision

Neutral particles energy spectra for 900 GeV and 7 TeV p-p collisions, measured by the LHCf experiment

Introduction. Tau leptons. SLHC. Summary. Muons. Scott S. Snyder Brookhaven National Laboratory ILC Physics and Detector workshop Snowmass, Aug 2005

Jet Reconstruction and Energy Scale Determination in ATLAS

Identifying Particle Trajectories in CMS using the Long Barrel Geometry

Stathes D. Paganis Nevis Laboratories, Columbia University, Irvington NY, 10533, USA (On behalf of the ZEUS Collaboration)

PoS(BORMIO2016)013. PANDA Forward Spectrometer Calorimeter. P.A. Semenov IHEP NRC KI S.I. Bukreeva IHEP NRC KI ITEP NRC KI

Performance of the CMS drift tube chambers with cosmic rays

Reconstruction in Collider Experiments (Part IX)

Atlas Status and Perspectives

Performance and calibration of CASTOR calorimeter at CMS

Longitudinal Double Spin Asymmetry in Inclusive Jet Production at STAR

Transcription:

Journal of Physics: Conference Series ATLAS Tile Calorimeter performance for single particles in beam tests To cite this article: T Davidek and the Atlas Tilecal system 2009 J. Phys.: Conf. Ser. 160 012057 View the article online for updates and enhancements. Related content - Data Quality system of the ATLAS hadronic Tile calorimeter Stanislav Nemecek and on behalf of the ATLAS Tile Calorimeter group) - Hadron response and shower development in the ATLAS calorimeters Margar Simonyan and the ATLAS Calorimeter Group, Atlas Collaboration - Calibration of the Tile Hadronic Calorimeter of ATLAS at LHC Djamel Boumediene and the ATLAS collaboration This content was downloaded from IP address 148.251.232.83 on 28/04/2018 at 20:16

ATLAS Tile Calorimeter performance for single particles in beam tests T. Davidek on behalf of the ATLAS Tilecal system Charles University in Prague, Institute of Particle and Nuclear Physics, V Holesovickach 2, 18000 Praha 8, Czech Republic E-mail: Tomas.Davidek@mff.cuni.cz Abstract. The modules of the ATLAS Tile hadronic calorimeter underwent extensive tests in the test beams at CERN. Studies were carried out with electrons, muons and hadrons ranging in energy from 10 GeV to 350 GeV. The Tilecal calibration systems and energy reconstruction algorithms were also studied in great details, the associated systematics has been evaluated. The updated calibration scheme led to improved linearity and uniformity of the response. Electrons and muons were used to set and understand the electromagnetic (EM) scale and the uniformity of the calorimeter. The pion response shows the expected behaviour with energy. The performance of the real Tile calorimeter modules to pions in terms of linearity and resolution corresponds well to that of earlier Tilecal prototype modules, after accounting for the different lengths and segmentations of the calorimeters. The experimental results are also compared to MC simulation samples. 1. Introduction The ATLAS experiment at the CERN Large Hadron Collider (LHC) is designed for precise measurements and fundamental discoveries in proton-proton collisions at the center-of-mass energy of 14 TeV. Calorimeters represent an indispensable part of the ATLAS detector system. The electromagnetic lead/liquid argon (LAr) calorimeter followed by the hadronic Tile calorimeter cover the central region of the ATLAS detector, other LAr based calorimeters span across the forward regions [1]. The Tile Calorimeter (Tilecal) is a hadron iron/plastic scintillator calorimeter. It consists of three cylinders one central barrel (LB) and two extended barrels (EB) on its sides. Every cylinder is composed of 64 modules, each covering the azimuthal angle of 2π/64 0.1 [2]. Tilecal modules are made of alternating layers of iron plates and scintillating tiles. The tiles are placed parallel to the incoming particles and radially staggered in depth. A schematic drawing is given in Fig. 1. The scintillating tiles are read-out by wave-length shifting (WLS) fibers on both sides of the module. These fibers deliver the light to photo-multipliers located in the outer iron structure that also houses the front-end electronics. Each cell is readout by 2 PMTs. The calorimeter modules are segmented into three radial compartments. These compartments are further subdivided into cells of the dimension η φ = 0.1 0.1 (0.2 0.1 in the third radial compartment). c 2009 IOP Publishing Ltd 1

PMT Wavelength Shifting Fiber Scintillator Steel Source Tubes Figure 1. Mechanical structure of a TileCal module, showing the slots in the iron for scintillating tiles and the method of light collection by WLS fibers to PMTs. Radially, tiles are organized in eleven rows (tilerows) of different size. Figure 2. The typical setup for beam tests comprised the barrel module 0 in the bottom, final LB module in the middle and two final EB modules in the top. Also shown is the wall of muon counters downstream of the calorimeter stack, that assisted in tagging muons and/or calorimeter punchthrough. 1.1. Tilecal beam tests The final Tilecal modules have been extensively tested with electron, muon and hadron beams, ranging in momentum from 10 to 350 GeV/c. Altogether, 11% of all modules were exposed to SPS beams in H8 beam-line at CERN during the years 2000 2003. The modules under tests were placed on the scanning table, that could be positioned at various η, φ and z with respect to the incoming particle beams. A typical setup is drawn in Fig. 2. The stack consisted of the very first barrel module (so-called module 0) in the bottom, one LB module in the middle and either two EB modules or another LB module in the top. The main goals of this testing program were to set and measure the energy-to-charge conversion factor, to explore the uniformity of the response and to determine the calorimeter performance at projective pseudorapidities. In order to address these goals, data were taken in various configurations: Electrons impinging at the angle of 20 measured from the η = 0 direction were used to determine the EM scale as well as the uniformity of the cells in first radial compartment. Muons entering at ±90 were used to address the uniformity of the modules over all cells. Electron data were taken in this configuration too in order to determine the uniformity of the cells on the module edges. Beams impinging at ±90 were also used for special studies, e.g. hadron shower profiles [3], light-yield measurement etc. Runs at projective pseudorapidities were used to assess the detector performance in the ATLAS -like configuration. The attention was focused on the pion linearity and resolution, however the performance to electrons and muons was also explored. 2. Tilecal calibration systems The Tilecal design includes four calibration and monitoring systems: Cesium (Cs) source system, that monitors the scintillators and PMTs responses minimum bias system for precise in-situ monitoring and (relative) luminosity measurement laser system, that monitors the PMT and front-end electronics 2

charge injection system (CIS) to calibrate the front-end electronics While Cs-source and minimum bias systems share the slow integrator readout (samples with approx. 100 Hz frequency), laser, CIS and physics data are readout through pulsed electronics chain that samples every 25 ns [4]. The Cs-source system and CIS are crucial for setting up the EM scale of the modules in the beam tests, therefore their main features are highlighted below. 2.1. Cesium source system The Cs-source system is designed to measure the quality of the optical response of each calorimeter cell. Using this system, the response of every cell is equalized prior to the particle data taking. The 137 Cs radioactive source is passing at normal incidence through holes in every tile and absorber plate of the calorimeter, as indicated in Fig. 1. Since the Cs-source movement through the calorimeter is very well controlled, one can reconstruct amplitudes of the individual tile responses (see Fig. 3). The gain of the cell is then determined as the average amplitude over all tiles in that cell. 2.2. Charge injection system The pulse readout electronics for each PMT contains two analog scales, referred to as high- and low-gain. Both are digitized with 10-bit ADC. This bi-gain system allows to measure energies up to 1.6 TeV/cell, while it is still sensitive to small signals e.g. from muons. CIS is designed to inject well-defined charge into both scales and to provide the respective conversion factors. Dedicated studies showed that a non-linearity up to 2% occurs in the lowgain due to the high-gain analog circuit saturation (see Fig. 4). The measured dependence is used offline for correcting data acquired via the pulsed electronics chain. The uncertainty associated with the ADC performance and the calibration constant determination has also been evaluated [5]. It is below 0.7% for single particle response over the full energy range. The impact on jet energy measurement will be even smaller, since much more channels will be involved. 3. Data analysis 3.1. Event selection The beams in are usually a mixture of electrons, muons and hadrons. In order to measure the response to a given particle type, a careful event selection has to be performed. Two kinds of selection criteria were combined the beam and particle separation cuts. The beam cuts require a MIP-like signal in upstream beam scintillators to avoid upstream showering and/or double particle events. The angular spread and impact point, measured by two x-y wire chambers, was also restricted in order to avoid halo particles that potentially have incorrect beam energy. Particle selection criteria: Muons, that leave only small signal in the calorimeter, are selected by a cut on the total energy. The muon wall also assisted in the detection of high-energy muons that pass through the whole calorimeter. The electron/pion separation relies on the difference in size between the compact EM showers and rather large hadron showers. The average density is used for this purpose: AvD = 1 N cell E i (1) N cell V i=1 i 3

Residual (%) 2 1 0 z [cm] -1 Figure 3. The Cs-source signal measured in one PMT as a function of the source position. The signal (middle curve) is obtained by subtracting the leakage estimate (bottom curve) from raw data (top curve). The individual tile amplitudes (full circles) are obtained by fitting the signal by a sum of pulse shape functions for individual tiles. -2 0 100 200 300 400 500 600 700 Charge (pc) Figure 4. The non-linearity in lowgain as mapped with CIS. Horizontal axis indicate the true injected charge, the vertical axis shows relative difference between the measured and true charge. Cher.[ADC counts] 1000 900 800 700 600 500 400 300 200 100 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 3 AvD[1000*pC/cm ] Figure 5. Example of electron/pion separation for E beam = 20 GeV. The average density defined by Eq. (1) is used as a baseline, the Cerenkov counter signal is used to improve the selection. The two lines denote the applied cuts, the bottom left region corresponds to pions selected for further analysis. where E i, V i denote the energy and volume of the i-th cell. For beam energies E beam 20 GeV, the threshold Cerenkov counter is used to further improve the separation. An example is shown in Fig. 5. Apart from muons, electrons and pions, the positive-charged beams also contain a considerable fraction of protons. The pion:proton share is energy dependent and ranges approximately from 3:1 at 50 GeV up to 1:4 at 180 GeV. The threshold Cerenkov counter with appropriate settings is used for pion/proton separation. 3.2. Corrections applied to raw data In all the analyses, the raw calorimeter data are corrected for dead channels. The energy is recovered by considering twice the signal from the second PMT reading the same cell in case the first PMT is malfunctioning. The possible impact of the electron/pion separation procedure on the total pion response was also carefully studied. Since the event selection is based on the shower shapes, the pion events 4

TM97.5 (pc) 11.4 11.2 11 10.8 10.6 10.4 10.2 10 9.8 0 2 4 6 8 10 12 Tilerow Figure 6. The muon response summed up over the whole LB module length in the 90 configuration. Mean value of muon signal truncated at 97.5% of the total number of entries (TM97.5) was adopted as the definition of the calorimeter response. Results are averaged over 5 LB modules for every tilerow, the error bars represent the corresponding RMS spreads. Vertical dotted lines indicate the individual radial compartments in the LB module. with high EM content tend to be classified as electrons. This may lead to underestimation of the total pion response. The possible bias has been studied with MC and also with nominal pion beams, that contain only negligible fraction of electrons (as opposed to nominal electron beams, where the electron:pion ratio typically ranges from 1:1.5 to 2:1 depending on the energy and the exact beam settings). It was found that the above mentioned electron/hadron separation procedure causes an underestimation of the total pion response by less then 0.4% in electron runs, nevertheless we correct for this effect. The impact on the pion energy resolution was found negligible. The real beam energy is calculated for every run using the data of the bending magnet and collimator settings in the beam-line. As a result, the real beam energies are slightly different for nominal pion and electron beams. The calculation also takes into account the synchrotron radiation of electrons, therefore electrons have lower energy than pions even in the same nominal electron beam. Other two corrections are described in more detail in the following Sections 3.2.1, 3.2.2. 3.2.1. Particle/Cs correction High-energy muons entering the calorimeter modules at ±90 are used to study the uniformity of the individual cell response and to ensure that the EM scale is kept along all cells. To check the EM scale in individual tilerows, the muon signal was summed up over the whole tilerow (i.e. approximately 6 m in LB and 3 m in EB modules). An example for LB modules is shown in Fig. 6, after the gains of all PMTs were equalized with Cs. The signal is clearly underestimated in the second and third radial compartment. This effect is due to trapezoidal shape of the tiles. The signal in a tile increases along the radial direction from the edge at lower radius to that at higher radius (approximately by 1%/cm). Since Cs pipes run through the tiles close to their upper edge, the Cs signal is bigger than that induced by particles passing through the center of the tile, which in turn well represents the average signal over the tile surface. The same result was obtained with electrons entering the tile-centers in 90 configuration and was further confirmed by special 137 Cs and 90 Sr source measurements. This effect is corrected for by applying weights in individual radial compartments 1. The weight in the first radial compartment is set to one, in order to preserve the EM scale as 1 The individual tilerow corrections cannot be applied for beams entering at projective pseudorapidities, since every PMT collects the signal from several tilerows in the given cell. 5

Compartment Barrel Extended barrel 1 1.000 1.000 2 1.025 ± 0.002 1.009 ± 0.005 3 1.088 ± 0.005 1.055 ± 0.003 Table 1. The weights to correct for the particle/cs difference, averaged over several analyzed modules. Statistical errors are shown as well. leakage (peak) [%] 1 η 0 3 4 5 6 7 8 9-1 10 pion 20 GeV 50 GeV 100 GeV 180 GeV σ/e peak 0.16 20 GeV 0.14 0.12 0.1 50 GeV 100 GeV 180 GeV 0.08-1 10 7 8 9 10 11 x [λ] 0.06 6 7 8 9 10 11 12 x [ λ] Figure 7. The longitudinal leakage correction of the pion response (Gaussian peak) as a function of calorimeter depth expressed in terms of interaction lengths [3]. Figure 8. The energy resolution for pions as a function of the calorimeter depth expressed in terms of interaction lengths [3]. determined with electrons at 20. The weights in the second and the third radial compartment are evaluated as the ratio of the mean muon responses in the respective tilerows. The pattern observed in the EB modules is very similar to that shown in Fig. 6 for LB modules, nevertheless the weights differ due to different radial segmentation. Whereas the second and third radial compartment in LB modules is composed of six and two tilerows respectively, four tilerows constitute both second and third radial compartment in EB modules. The weights are averaged over all modules analyzed. Their values are listed in table 1. 3.2.2. Corrections for calorimeter length The pion response is corrected for the longitudinal leakage, that has been measured in the 90 configuration [3], see Fig. 7. The results presented in Section 3.3.2 are rescaled for an infinitely long calorimeter. This approach also enables a simple comparison to beam-tests results of earlier prototype Tilecal modules [2], that were radially longer 9.30 λ at 20, while final modules are 7.84 λ long at the same impact angle. The energy resolution scales with the calorimeter length too. In order to compare the energy resolution for pions between the final and prototype calorimeter modules (see Section 3.3.2), the results from prototype modules were rescaled for the length of final modules. The measurements performed in 90 configuration were used to determine the scaling factor, see Fig. 8. 3.3. Results The results reported in this paper come from recently re-calibrated data acquired during the beam test periods 2002 2003. 6

Events 60 40 20 0 0.7 0.8 0.9 1 1.1 1.2 R e (pc/gev) Figure 9. The cell response as measured for electrons at 20 of incidence. Each entry corresponds to one impact cell. The average EM scale factor 1.05±0.003 pc/gev is obtained, the cell uniformity shows an RMS spread of (2.4 ± 0.1)%. E( π)/e beam 0.94 Figure 10. The relative pion response 0.92 (black circles) as a function of the pion 0.9 0.88 beam energy. Pions impinge the calorimeter modules at pseudorapidity η = 0.35. 0.86 0.84 The pion response is corrected for the longitudinal leakage, i.e the results are scaled 0.82 0.8 for an infinitely long calorimeter. Superimposed are the MC results (open squares), 0.78 0.76 2 10 10 the dashed line corresponds to usual parameterization [6] with e/h = E beam [GeV] 1.36. 3.3.1. Electromagnetic scale The EM scale is measured with electron beams. As the calorimeter response to electrons slightly depends on the impact angle (due to sampling fraction frequency that also changes with incident angle), the EM scale is determined at a fixed angle in all modules. The angle of 20 was chosen for this purpose; it corresponds to pseudorapidity η = 0.35. Electrons at the incidence angle of 20 were shot into all cells of the first radial compartment, entering the cell-center. The mean response measured over all such cells in all tested modules determines the EM scale factor, see Fig. 9. The uniformity of the response is fully explained by the tile-to-tile response variation (see also Fig. 3) as has been demonstrated by MC simulations. 3.3.2. Response to pions The important parameters of a hadronic calorimeter are the response linearity and the associated energy resolution to incoming hadrons. The pion response 2 is shown in Fig. 10 relative to the beam energy of incident pions, after all corrections mentioned in Section 3.2 have been applied. The results demonstrate that Tilecal is a non-compensated calorimeter, the pion response is well described by the parameterization proposed by Fabjan [6] with e/h = 1.36 [7]. MC results (Geant4.8.3 using QGSP and Bertinicascades models) match well the experimental data. The energy resolution for pions is shown in Fig. 11. The data were fitted by the standard energy resolution formula σ E = A Ebeam C (2) The fit results in A = (52.7 ±0.9)%, C = (5.7 ±0.2)%. The results are in reasonable agreement with MC simulations (same version as for linearity studies). 2 Defined as Gaussian mean fitted on the signal spectrum in the range from 2σ to +2σ around this Gaussian mean value. 7

σ /E 0.18 0.16 0.14 0.12 0.1 0.08 0.06 350 GeV 180 GeV 100 GeV 50 GeV 0.05 0.1 0.15 0.2 0.25 0.3 0.35 1/ E 20 GeV 10 GeV 2 χ / ndf 1.312 / 4 Prob 0.8594 p0 0.5273 ± 0.009352 p1 0.05713 ± 0.00171 Figure 11. The energy resolution for pions incident at η = 0.35 (full circles), superimposed are MC results (open squares). Also shown are the earlier results from prototype modules (open triangle), that are rescaled to the length of the final calorimeter modules. Earlier prototype data results 3 have been rescaled to the final Tilecal module length (see Section 3.2.2). A fair agreement is observed between the prototype and final Tilecal modules, as can also be appreciated from Fig. 11. 4. Conclusions A big effort has been invested into understanding many details of the Tile calorimeter calibration and its performance for particles. The calibration systems have been investigated in great details. The procedure to reconstruct the Cs-signal and to determine the gain of a cell has been improved as well as our understanding of the pulsed electronics calibration. The EM scale was measured with electrons and the charge-to-energy conversion factor has been determined. The cell-to-cell uniformity as observed with electrons at 20 incidence has been explained by the variation in individual tile responses. Muons provide a tool to check the EM scale in all cells of the calorimeter. The analysis of muon response resulted in additional particle/cs correction that restores the EM scale in second and third radial compartment. The response to pions has been carefully studied. The pion linearity curve, after correcting for all known effects, scales logarithmically with beam energy as expected. The results with final modules are compatible with recent MC simulations and also similar to results from earlier prototype modules. The energy resolution for pions corresponds well to that of prototype modules. It is also well reproduced by MC simulations. The experience at the beam tests should allow to calibrate all Tilecal channels at the EM scale with a precision of 1 2%. References [1] ATLAS collaboration 1999 ATLAS Detector and Physics Performance Technical Design Report 1,2, CERN/LHCC/99-14 [2] ATLAS/Tile Calorimeter collaboration 1996 Tile Calorimeter Technical Design Report, CERN/LHCC/96-42 [3] Hakobyan H Simonyan M Carli T and Henriques-Correia A M 2007 Measurement of Pion and Proton Longitudinal Shower Profiles up to 20 Nuclear Interaction Lengths with the ATLAS Tile Calorimeter, ATL-TILECAL-PUB-2007-008, CERN [4] Anderson K et al 2005 Nucl. Instr. and Meth. A 551 p 469 [5] Anderson K Hurwitz M H Jen-La Plante I Pilcher J E and Teuscher R 2008 Performance and Calibration of the TileCal Fast Readout Using the Charge Injection System, ATL-TILECAL-INT-2008-002, CERN [6] Fabjan C W Ludlam T 1982 Ann. Rev. Nucl. Part. Sci. 32 p 335 [7] Akhmadaliev S et al 2000 Nucl. Instr. and Meth. A 449 p 461 3 It should be noted that the energy resolution parameters A, C quoted for prototype modules in Ref. [2] are better due to longer calorimeter. Moreover, the linear sum was used in the fit instead of the quadrature sum in formula (2). 8