Cerno Application Note Extending the Limits of Mass Spectrometry

Similar documents
Cerno Application Note Extending the Limits of Mass Spectrometry

Cerno Application Note Extending the Limits of Mass Spectrometry

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Multi-residue analysis of pesticides by GC-HRMS

MassHunter TOF/QTOF Users Meeting

Identifying Disinfection Byproducts in Treated Water

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Automated and accurate component detection using reference mass spectra

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

MassHunter Software Overview

Making Sense of Differences in LCMS Data: Integrated Tools

Accurate Mass for GC/MSD & LC/MSD

WADA Technical Document TD2003IDCR

Theory and Practical Consequences.

Welcome! Course 7: Concepts for LC-MS

Automatic Generation of Extract ion Chromatogram for Mass Spectral Peaks with Specific Isotope Labeled Patterns

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Benchtop NMR Combined with GC/MS Confirms Identity of Forensic Case Sample

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Interpretation of Organic Spectra. Chem 4361/8361

ChemSpider Main Menu. Select Advanced Search

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Die Nadel im Heuhaufen

Agilent All Ions MS/MS

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Metabolomics in an Identity Crisis? Am I a Feature or a Compound? The world leader in serving science

Analytical Technologies and Compound Identification. Daniel L. Norwood, MSPH, PhD SCĪO Analytical Consulting, LLC.

WADA Technical Document TD2015IDCR

Development and application of methodology for designer drugs

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Compounding insights Thermo Scientific Compound Discoverer Software

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

SIFT-MS. technology overview

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

White Paper. Application of GC-MS/MS in the Analysis of Taints and Off Flavours. Alan Rose Technical Specialist. Donna Byrom Technical Specialist

What s New in NIST11 (April 3, 2011)

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Mass spectroscopy ( Mass spec )

Deposition and Detection System. Trace Level Analysis of Chemical Warfare Agents (CWAs) Related Chemicals by GC-IR Solid Phase System

Workflow Using Hyphenated Mass Spectrometry Techniques

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

High Throughpu[ Separations and Structural Information Achieved with Automated LC/MS. Michael P. Balogh, Matthew J. Dilts Waters Chromatography

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

Agilent MassHunter Quantitative Data Analysis

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

The Pitfalls of Peaklist Generation Software Performance on Database Searches

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Agilent MassHunter Quantitative Data Analysis

TIME OF FLIGHT GC/MSTOF

4-methyl-1-phenyl-2-pyrrolidin-1-yl-pentan-1-one

4-Methyldiethcathinone (4-MDEC)

Application News. No. C154. Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Ben Diamond. Sonoma State University

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

UNIFI - Targeted and Untargeted Screening MS Software

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

1-(1,3-benzodioxol-5-yl)-2-(ethylamino)hexan-1-one

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

Highly Sensitive and Rugged GC/MS/MS Tool

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles

Implementing GC-HRAM MS for More Efficient and Effective Routine Pesticide Residues Analysis

Agilent ESI and APCI sources: for polar to non-polar compounds

Method for the Routine Determination of Accurate Masses by Triple Quadrupole Mass Spectrometry

Application Note. Edgar Naegele. Abstract

Determination of Elemental Sulfur in Explosives and. Explosive Residues by Gas Chromatography-Mass Spectrometry. Kimberly S.

Modeling Mass Spectrometry-Based Protein Analysis

NOTE BY THE TECHNICAL SECRETARIAT

Agilent G3212 GC-APCI Source

Introduction to GC/MS

Agilent Technologies at TIAFT 2013

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

Information Dependent Acquisition (IDA) 1

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

AppNote 2/2002. Discrimination of Soft Drinks using a Chemical Sensor and Principal Component Analysis KEYWORDS ABSTRACT

FUTURE CONFIRMATORY CRITERIA

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

How to screen and identify unexpected and unwanted compounds in food

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

2-[[2-(4-ethyl-2,5-dimethoxy-phenyl)ethylamino]methyl]phenol

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

Application Note. Authors. Abstract. Introduction. Environmental

Overview. Introduction

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Methyl 1-[(4-fluorophenyl)methyl]indazole-3-carboxylate

Construction and Use of API Single- Quadrupole MS Spectral Libraries.

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Transcription:

Confident Compound Identification with High Mass Accuracy and Elemental Composition Specific NIST Library Search Identification of unknown compounds by unit mass resolution GC-MS systems essentially relies on searching an existing database/library (such as NIST) by comparing spectra of an unknown compound with those in the library as molecular and fragment ions of a compound carry fingerprints of the molecule. One critical requirement to achieve successful compound identification is to have pure mass spectra available, which can be obtained by either rigorous GC separation or spectral deconvolution if two or more components co-elute. Otherwise, confidence in the conventional library search will be compromised, as the library search for the complex spectra often results in poor matching values. Such a challenging issue can usually be addressed by obtaining high mass accuracy and performing elemental composition determination on individual ions with high resolution mass spectrometers. However, the high cost of high resolution mass spectrometers remains a major obstacle for the majority of GC/MS users to take advantage of this approach. Here we report an effective and economic alternative to perform NIST library search with high mass accuracy and specified elemental composition utilizing unit mass resolution single quadrupole GC/MS systems. This is implemented through software interaction between MassWorks (, Norwalk, CT) and NIST MS Search (NIST, Gaithersburg, MD) and illustrated with below examples. Data acquisition of two samples was done on different GC/MS systems. One sample of food industry powder was introduced through Headspace-SPME with a polyacrylate fiber onto a Thermo Scientific TRACE 1310 GC coupled to TSQ8000 GC-MS/MS operated in full scan mode. Data was acquired in continuum (profile) mode at a rate of 6,197 u/s (0.071 dwell time, 0.075 s cycle time) and an acquisition threshold of zero. Another forensic sample was acquired in Agilent GC/MSD under following conditions: A raw scan mode was selected with a scan speed 2^2 (A/D samples = 4) over a mass range of 40-550 m/z with ion threshold set to zero. All data processing was conducted with MassWorks and NIST MS Search. As shown in Figure 1, an unknown peak eluted at RT=11.5 min and has major ions observed at m/z 150, 121, 108, and 43. The largest ions at m/z 150 in the spectra, most likely molecular ions, were first analyzed by MassWorks to achieve high mass accuracy of 1.9 md and high spectral accuracy of 99.2% as shown in Figure 2. The elemental composition for the m/z 150 was determined to be C8H14S2 with high confidence, because there is huge spectral accuracy differentiation about 2% between the first best and the second best candidates. In addition, very high spectral accuracy was found for the determination as illustrated by an almost perfect match between theoretical calculated and calibrated spectra (Figure 1, spectral overlay in insert). However, in order to identify the unknown compound(s), it is necessary to perform NIST library search to obtain structures of the molecules. With the newly released MassWorks 5.0, not only is conventional NIST library search available, but also restricted NIST library search with high mass accuracy or elemental composition as a constraint can be implemented to enhance the search performance. Similar to all other third party search software, MassWorks can launch a conventional NIST library search without any specific constraints. It is noteworthy that under the MS Search menu item of library search option/presearch, three choices, i.e., default, fast, and off, can be selected. When the choice off is selected, a more thorough search will be performed than with the other two selections,

but that takes a little longer time. This more thorough search is recommended for a true unknown identification or a challenging case as shown below. With this conventional search, the most likely compound for the unknown peak was found to be 2(3H)-Naphthalenone, 4,4a,5,6,7,8-hexahydro-, but the search has very poor match values (reverse/forward match/probability = 667/705/10.6%). The mismatch is obvious as the base peak in the measured spectra is m/z 121 and there are abundant ions observed at m/z 43. In the library spectra of 2(3H)-Naphthalenone, 4,4a,5,6,7,8-hexahydro-, on the other hand, m/z 122 is the base peak instead of the m/z 121. More importantly, there are no ions at m/z 43 observed in the library spectra. Therefore, the unknown compound is not 2(3H)-Naphthalenone, 4,4a,5,6,7,8-hexahydro-. Following the first unsatisfactory search, further investigation employed the second search routine with a constraint of high mass accuracy. In this example, a mass tolerance of 5 md was used. This means the search would find all the compounds (in the NIST library) whose m/z values of molecular ions are within 5 md mass error with respect to the accurate mass at m/z of 150.0550. This search has resulted in a total of 85 different compounds (Figure 3) compared with a total of 400 compounds listed in the results from the previous search (Figure 2). The significant reduction on possible candidates is evidently attributed to high mass accuracy used in the search. A close look at all the compounds from the second search list shows they have only five different elemental compositions including C6H6N4O, C6H14S2, C9H10S, C5H10O5, and C5H14OSSi. All of them have multiple isomers except for C5H14OSSi. Using the elemental composition C6H14S2 determined by MassWorks as another constraint, the third search routine further reduced the number of candidates to 27 (Figure 4). By definition, these 27 compounds are isomers and have the same elemental composition of C6H14S2. Indeed, the correct compound is bis(1-methylethyl) disulfide, number 3 on the list, as highlighted in blue. The reason it has a poor match value of 591 and low probability of 23.8% is that the experimentally observed spectra are complex spectra that resulted from two co-eluted compounds. In other words, the bis(1-methylethyl) disulfide co-eluted with another compound, 2-ethyal-6-methyl Pyrazine, as reported previously (1). In addition to the NIST library search, MassWorks can also directly link its determined elemental composition to the ChemSpider database for compound identification. This capability will provide extra confirmation when a compound is positively identified by any one of the three kinds of NIST library searches. It is particularly useful when the compound of interest does not have its GC/MS spectra included in the NIST library. For the example of forensic analysis, the molecular ions of an unknown were determined to have elemental composition of C4H8N4O4S2 with high spectral accuracy of 98.9% (Figure 5). However, no compound was found when searching the NIST library with the elemental composition C4H8N4O4S2 as a search constraint. By selecting the pop-up menu item of Launch ChemSpider for C4H8N4O4S2, the ChemSpider database search for the elemental composition was performed. As a result, the correct compound was identified as tetramethylenedisulfotetramine, the first on the search list (Figure 6).

Figure 1. An unknown peak eluted at RT=11.5 and accurate mass measurements and elemental composition determination of m/z 150. Figure 2. Conventional NIST library search for mass spectra of the unknown peak.

Figure 3. Accurate mass NIST library search for the unknown peak. Figure 4. Elemental composition specific NIST library search for the unknown peak.

Figure 5. Launch ChemSpider search from MassWorks. Figure 6. ChemSpider search results for C4H8N4O4S2 Reference (1) Gu M, Xu HL, Wang YD. High Mass Accuracy Measurements and Elemental Composition Determination of Molecular Ions of Pesticides with a Single Quadrupole GC/MS System Proc. 53rd ASMS Conf. Mass Spectrometry and Allied Topics, St. Louis, MO, May 31 - June 4, 2015