MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Similar documents
Agilent All Ions MS/MS

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Agilent METLIN Personal Metabolite Database and Library MORE CONFIDENCE IN COMPOUND IDENTIFICATION

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Agilent G3212 GC-APCI Source

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Application Note. Edgar Naegele. Abstract

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

Accurate Mass Analysis of Hydraulic Fracturing Waters

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Application Note. Edgar Naegele. Abstract

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Die Nadel im Heuhaufen

Computer-assisted analysis of complex natural product extracts

MassHunter TOF/QTOF Users Meeting

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

UPLC Intact MASS Analysis Application Kit

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

QTOF Training Manual

Detection of Trace Level Pharmaceuticals in Drinking Water by Online SPE Enrichment with the Agilent 1200 Infinity Series Online-SPE Solution

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Use of the SFC-MS Splitter Kit G

Application Note. Abstract. Authors. Environmental

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Agilent ESI and APCI sources: for polar to non-polar compounds

Making Sense of Differences in LCMS Data: Integrated Tools

Understanding Your Spectra Module. Agilent OpenLAB CDS ChemStation Edition

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Application Note. Authors. Abstract. Introduction. Environmental

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

MassHunter Software Overview

Analyst Software. Peptide and Protein Quantitation Tutorial

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

C Glucose Qualitative Flux Analysis in HepG2 cells

Author. Abstract. Introduction

Analyst Software. Automatic Optimization Tutorial

Agilent LC & LC-MS Cannabis Testing

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Pharmaceutical Impurity Identification and Profiling Using Agilent Q-TOF LC/MS Combined with Advanced MassHunter Data Processing Software

Measuring Drug-to-Antibody Ratio (DAR) for Antibody-Drug Conjugates (ADCs) with UHPLC/Q-TOF

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

New Product Update. HPLC Columns

Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

TOF/QTOF Users Meeting. Jim Lau, Agilent Technologies.

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

ANALYTICAL REPORT 1 CUMYL-4CN-BINACA (C22H24N4O) 1-(4-cyanobutyl)-N-(1-methyl-1-phenylethyl)-1H-indazole-3-carboxamide

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

ANALYTICAL REPORT 1 1P-LSD (C23H29N3O2) N,N-diethyl-7-methyl-4-propanoyl-6,6a,8,9-tetrahydroindolo[4,3-fg]quinoline-9-

ANALYTICAL REPORT 1. 4-Me-TMP (C15H21NO2) Remark other NPS detected: none. sample contains some impurities (benzeneacetic acid + others)

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

Translational Biomarker Core

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Transcription:

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide What is the MassHunter METLIN Metabolite PCD/PCDL? 2 Where to find more information 2 Kit Content 3 Installation 5 Before you start 5 Install MassHunter METLIN Metabolite PCD 6 Install MassHunter METLIN Metabolite PCDL 6 Searching and managing the METLIN Metabolite PCD/PCDL 7 Identifying compounds and spectrum peaks using Qualitative Analysis 7 Managing METLIN Metabolite PCD/PCDL content with PCDL Manager 8 Chromatography Conditions 9 Capillary tubing ordering information 11 Positive Ion Polarity Analysis 12 Negative Ion Polarity Analysis 14 Agilent Technologies

What is the MassHunter METLIN Metabolite PCD/PCDL? The MassHunter METLIN Metabolite PCD (Personal Compound Database) and PCDL (Personal Compound Database and Library) is one of the best-known and most-comprehensive metabolite databases in the world today. It currently includes annotated lists of over 24,000 endogenous and exogenous metabolites, as well as di- and tripeptides. Each entry may include mass, chemical formula, and structure information, as well as ID numbers that link to more information about the compound, such as the CAS and ChemSpider IDs. The MassHunter METLIN Metabolite PCD/PCDL can be used as is, or as the basis of your own customized PCD or PCDL. You can add, remove and change the compounds in your PCD/PCDL to meet the specific needs of your laboratory and your analyses. Your customized PCD/PCDL can include the retention times for compounds you analyze. You can also add your own spectra to your customized PCDL, in addition to those provided in the master PCDL. The high mass accuracy of the Agilent tandem quadrupole time-of-flight (Q-TOF) LC/MS instrument provides the capability to screen all compounds in the library that are detected by their exact mass and retention time (if known). Searching the library can then identify the compounds found by comparison to their accurate product ion mass spectra. Terminology Note A PCD is an accurate mass compound database, which may or may not contain retention times. A PCDL contains both an accurate mass compound database and an MS/MS accurate mass spectral database, which is often referred to as a spectral library or library. Where to find more information Go to http://www.chem.agilent.com/ for the most current information on Agilent products. 2 MassHunter METLIN Metabolite PCD PCDL Quick Start Guide

Kit Content You will receive the following manuals and media when you purchase the MassHunter METLIN Metabolite PCD/PCDL. MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide, which tells you how to set up methods to acquire MS data that can be searched in the MassHunter METLIN Metabolite PCD/PCDL. MassHunter Personal Compound Database and Library Manager Quick Start Guide, which tells you how to install and use the MassHunter Personal Compound Database and Library Manager. MassHunter Personal Compound Database and Library Manager disk This disk contains: MassHunter Personal Compound Database and Library Manager MassHunter Personal Compound Database and Library Manager Quick Start Guide (PDF) Software license agreements Example data PCD version MassHunter METLIN Metabolite PCD disk This disk contains: MassHunter METLIN Metabolite PCD files: Metlin_AM_PCD.cdb (accurate mass compound database) Metlin_AMRT_PCD.cdb (accurate mass compound database with retention times) MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide (PDF) MassHunter METLIN Metabolite PCD compound listing (PDF) Example metabolite data files A file that contains a list of the METLIN Metabolite PCD compounds. MassHunter METLIN Metabolite PCD PCDL Quick Start Guide 3

PCDL version MassHunter METLIN Metabolite PCDL disk This disk contains: MassHunter METLIN Metabolite PCDL files: Metlin_AM_PCDL.cdb (accurate mass compound database and accurate mass MS/MS spectral library) Metlin_AMRT_PCDL.cdb (accurate mass compound database with retention times and accurate mass MS/MS spectral library) MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide (PDF) MassHunter METLIN Metabolite PCDL compound listing (PDF) Example metabolite data files A file that contains a list of the METLIN Metabolite PCDL compounds 4 MassHunter METLIN Metabolite PCD PCDL Quick Start Guide

Installation Before you start Follow these instructions to install MassHunter PCDL Manager and the MassHunter METLIN Metabolite PCD or PCDL on your computer. 1 Check that the Agilent 1200 Series LC is properly installed and verified. 2 Check that one of the following instruments is properly installed and verified: Agilent 6200 Series Time-of-Flight LC/MS (TOF), or Agilent 6500 Series Quadrupole Time-of-Flight (Q-TOF) NOTE A Q-TOF instrument is needed to use the MS/MS features in a PCDL. A TOF instrument does not produce MS/MS spectra. 3 Check that the following programs are properly installed: MassHunter Data Acquisition B.04.00 or higher MassHunter Qualitative Analysis B.04.00 or higher 4 Install MassHunter PCDL Manager, if it is not currently installed on your computer. Refer to the MassHunter Personal Compound Database and Library Manager Quick Start Guide for installation instructions. 5 Proceed to install either the MassHunter METLIN Metabolite PCD or PCDL as described on the next page. MassHunter METLIN Metabolite PCD PCDL Quick Start Guide 5

Install MassHunter METLIN Metabolite PCD 1 Place the MassHunter METLIN Metabolite PCD disk in your computer drive. 2 When the Contents and Information screen appears: a Click METLIN Metabolite PCD Installation. b Click Install the METLIN Metabolite AM and AMRT PCD files. The following files are installed on your computer: MassHunter\PCDL\Metlin_AM_PCD.cdb MassHunter\PCDL\Metlin_AMRT_PCD.cdb 3 When the installation is complete, remove the disk from the drive. Install MassHunter METLIN Metabolite PCDL 1 Place the MassHunter METLIN Metabolite PCDL disk in your computer drive. 2 When the Contents and Information screen appears: a Click METLIN Metabolite PCDL Installation. b Click Install the METLIN Metabolite AM and AMRT PCDL files. The following files are installed on your computer: MassHunter\PCDL\Metlin_AM_PCDL.cdb MassHunter\PCDL\Metlin_AMRT_PCDL.cdb 3 When the installation is complete, remove the disk from the drive. 6 MassHunter METLIN Metabolite PCD PCDL Quick Start Guide

Searching and managing the METLIN Metabolite PCD/PCDL Identifying compounds and spectrum peaks using Qualitative Analysis The following capabilities are available for a MassHunter METLIN Metabolite PCD/PCDL: If you want to... Search an accurate mass database (PCD) to identify compounds (with or without retention times) Search an accurate mass database (PCD) to identify compounds from spectrum peaks See this online Help topic in Qualitative Analysis: Identifying Compounds > Search database for a compound Spectrum Tasks > Search database from a spectrum Click this menu item: Identify > Search Database for Compounds Identify > Search Database for Spectrum Peaks The following capabilities are available for a MassHunter METLIN Metabolite PCDL-only: If you want to... Search an accurate mass spectral library (PCDL) to identify compounds Search an accurate mass spectral library (PCDL) for spectra See this online Help topic in Qualitative Analysis: Identifying Compounds > Search accurate mass library for compounds Spectrum Tasks > Search accurate mass library for spectra Click this menu item: Identify > Search Library for Compounds Identify > Search Library for Spectra MassHunter METLIN Metabolite PCD PCDL Quick Start Guide 7

Managing METLIN Metabolite PCD/PCDL content with PCDL Manager PCDL Manager lets you do the following to manage the content of your MassHunter METLIN Metabolite PCD/PCDL: Create and edit custom PCDs and PCDLs, including adding proprietary compounds, retention times, and MS/MS spectra. Search and store MS/MS centroid spectra acquired on a Q-TOF instrument. Search or browse MS/MS spectra. Search for compounds in PCDs and PCDLs, using text, formula, accurate mass, and retention time (optional or required). Import mass lists from Agilent MassHunter Mass Profiler, GeneSpring MS, and Qualitative Analysis software (for accurate mass and optional retention time searching only). Load spectra from either a.cef file or by copy-and-pasting mass spectra from MassHunter Qualitative Analysis software and search for those spectra in the current PCDL. Do private, on-site searches, which keep intellectual property safe. Link to web sites for more information on many compounds. For more information, see the MassHunter Personal Compound Database and Library Manager Quick Start Guide and PCDL Manager online Help. 8 MassHunter METLIN Metabolite PCD PCDL Quick Start Guide

Chromatography Conditions This section provides the LC/MS operating conditions that will let you successfully search and identify compounds and spectra in your data files using the MassHunter METLIN Metabolite PCD/PCDL with both accurate mass and retention time matching. The Agilent HPLC method is based on reverse phase separation. Note that this separation does not work well for the very hydrophilic compounds such as sugars, amino acids and organic acids, which are best analyzed by a HILIC type of analysis. 1 To track retention time stability and mass spectrometer abundance drift during analysis, add an internal standard (9-Anthracene carboxylic acid at 1 ng/ l) to the dissolution solvent. 9-Anthracene carboxylic acid is detectable in ESI and APCI in both positive and negative ion modes. 2 To re-suspend dried samples: a b c First add 50 µl of a solution of 9-Anthracene carboxylic acid at 2 ng/µl in methanol. Then add 50 µl of a solution of 0.4% (v/v) acetic acid in water. Vortex the sample after each addition of solvent to facilitate good recovery of hydrophobic metabolites such as the free fatty acids. 3 Use the following instrumentation to analyze the samples: Agilent 1260 SL System with Binary Pump (1312B), plumbed for minimum delay volume as described in the pump manual. For more information, see Capillary tubing ordering information on page 11. Agilent Solvent Degasser (G1379B) Agilent Autosampler (G1367C) and Thermostat (G1330B) Agilent Column Compartment (G1316C) Agilent TOF (62XX series) or Q/TOF (65XX series) MS instrument with Dual ESI Source (G3251B) 4 Set up an acquisition method in the MassHunter Data Acquisition program for your sample analyses, using the parameters given in the following sections: Positive Ion Polarity Analysis on page 12 Negative Ion Polarity Analysis on page 14 MassHunter METLIN Metabolite PCD PCDL Quick Start Guide 9

5 Identify compounds using the MassHunter METLIN Metabolite PCD by accurate mass and retention time matching (AMRT). See MassHunter Qualitative Analysis online Help for information on searching accurate mass databases. 6 (PCDL-only) Identify compounds using the MassHunter METLIN Metabolite PCDL by accurate mass library spectral matching. See MassHunter Qualitative Analysis online Help for information on searching accurate mass MS/MS libraries. 10 MassHunter METLIN Metabolite PCD PCDL Quick Start Guide

Capillary tubing ordering information This section provides the information to order the capillary tubing that is used to plumb the system for minimum delay volume, which is required for the Universal RP-AMRT method. Part Number Description G1312-87304 SS connecting capillary, 700 mm, 0.17mm (green) as outlet capillary from pump to injector Capillary connect from autosampler to column compartment: flexible capillary tubing (one of the following) G1316-87319 G1316-87318 340 mm, 0.12 mm id (red), connect directly to the heater block in the TCC 300 mm, 0.12 mm id (red), connect directly to the switching valve in the TCC 873700-936 Stainless steel guard column: Zorbax-SB-C8 Rapid resolution cartridge (2.1X 30mm 3.5 μm) 820555-901 Rapid resolution cartridge holder - hardware kit 827700-914 Separation column: Zorbax SB-Aq 1.8 μm 2.1 X 50mm G1316-87303 Attached to the rapid resolution system using (2) capillary connects: stainless steel tubing: 70mm, 0.12 mm ID (red label) Heater to guard column Guard column to analytical column 5042-6461 PEEK tubing (red), 0.005"/0.13mm, 1/16 OD, 5.0M; cut to 650 mm in length to connect the analytical column to MS equipped with dual ESI source MassHunter METLIN Metabolite PCD PCDL Quick Start Guide 11

Positive Ion Polarity Analysis The following conditions were used to determine the retention time data for many metabolite standards, which are contained in the MassHunter METLIN Metabolite PCD. Autosampler and Column Thermostat temperature: 4 C Injection volume: 2 μl Column temperature: 60 C Guard column: Zorbax-SB-C8 (P/N: 873700-936) Rapid Resolution Cartridge (2.1X 30mm 3.5 µm) using hardware kit (P/N: 820555-901). Analytical column: Zorbax SB-Aq 1.8 µm 2.1 X 50mm (P/N: 827700-914) Pump Flow rate: 0.6 ml/minute Solvent A: 0.2% (v/v) acetic acid in water Solvent B: 0.2% (v/v) acetic acid in methanol Initial solvent composition: 2% A / 98% B Gradient Time %B 0 2 13 98 19 98 Stop Time: 19 minutes Post Time: 5 minutes TOF / QTOF Acquisition Settings Positive Ion Mode Mass Range: 1700 m/z Instrument Mode: Extended Dynamic Range Data Storage: Centroid 12 MassHunter METLIN Metabolite PCD PCDL Quick Start Guide

Abs. threshold: 100 Rel. threshold(%): 0.001 Dual ESI Source Settings Gas Temp: 325 C Drying Gas: 10 L/minute Nebulizer pressure: 45 psig VCap: 4000V Fragmentor: 140V Skimmer: 65V Oct 1 RF Vpp: 750 V Spectral Parameters Stored Mass Range: 50-1600 m/z Acquisition Rate: 1.5 spectra /sec Reference Mass Correction: Enabled Reference Masses: 121.050873, 922.009798 MassHunter METLIN Metabolite PCD PCDL Quick Start Guide 13

Negative Ion Polarity Analysis The following conditions were used to determine the retention time data for many metabolite standards, which are contained in the MassHunter METLIN Metabolite PCD. Autosampler and Column Thermostat temperature: 4 C Injection volume: 2 μl Column temperature: 60 C Guard column: Zorbax-SB-C8 (P/N: 873700-936) Rapid Resolution Cartridge (2.1X 30mm 3.5 µm) using hardware kit (P/N: 820555-901). Analytical column: Zorbax SB-Aq 1.8 µm 2.1 X 50mm (P/N: 827700-914) Pump Flow rate: 0.6 ml/minute Solvent A: 0.2% (v/v) acetic acid in water Solvent B: 0.2% (v/v) acetic acid in methanol Initial solvent composition: 2% A / 98% B Gradient Time %B 0 2 13 98 19 98 Stop Time: 19 minutes Post Time: 5 minutes TOF / QTOF Acquisition Settings Negative Ion Mode Mass Range: 1700 m/z Instrument Mode: Extended Dynamic Range Data Storage: Centroid 14 MassHunter METLIN Metabolite PCD PCDL Quick Start Guide

Abs. threshold: 100 Rel. threshold(%): 0.001 Dual ESI Source Settings Gas Temp: 325 C Drying Gas: 10 L/minute Nebulizer pressure: 45 psig VCap: 3500V Fragmentor: 140V Skimmer: 65V Oct 1 RF Vpp: 750 V Spectral Parameters Stored Mass Range: 50-1600 m/z Acquisition Rate: 1.5 spectra /sec Reference Mass Correction: Enabled Reference Masses: 119.03632, 980.016375 MassHunter METLIN Metabolite PCD PCDL Quick Start Guide 15

www.agilent.com In This Guide This Quick Start Guide describes how to install and use the Agilent MassHunter METLIN Metabolite PCD/PCDL. This information is subject to change without notice. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages with the furnishing, performance or use of this material. Agilent specifically disclaims any warranties for any implied warranties of merchantability or fitness for a particular purpose. This guide is valid for the B.04.00 revision or higher of the MassHunter METLIN Metabolite PCD/PCDL, until superseded. Agilent Technologies, Inc. 2011 Printed in USA Revision A, March 2011 *G6825-90004* G6825-90004 Agilent Technologies