STANDARD OPERATING PROCEDURE

Similar documents
How to use a Micrometer

USS ProCoil Company. WELCOME To Micrometer Training. Introduction and Lecture Phase I 6/18/2010

product manual H-4204 Proving Ring Penetrometer

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

STANDARD OPERATING PROCEDURE

5-25x56 PMII PSR With Double Turn

Uncertainty Analysis of Experimental Data and Dimensional Measurements

15 E OWNER S MANUAL PIRATE SPYGLASS BRING EM NEAR PIRATE SPYGLASS TELESCOPE 5 W 30 W 60 W 45 W

TESA MICROMASTER Electronic Micrometers with Digital Display

LEAPERS, INC. RED/GREEN DOTS

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

ZFK 4 X 25. Description and Utilization Instructions

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

DISCONTINUED PRECISION MEASURING FOWLER CALIPERS 1 - VERNIER CALIPERS 4 - ELECTRONIC CALIPERS

10-10 DIIAUS. Precision Reloading Scale

ITTC Recommended Procedures and Guidelines

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

Laboratory Manual Physics_1. Index of refraction for solids

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

MARINE BINOCULARS ZHUMELL 7X50 MARINE BINOCULARS WITH COMPASS AND RETICLE

Facilities Management

5-25x56 PMII PSR Illuminated with Double Turn

HEAVY DUTY SWING-OUT VALVE

Physical Measurements

Introduction To Metrology

HEAVY DUTY SWING-OUT VALVE

Table of Contents. Specifications 1 Adjustments 2 Using the Reticle 8 Maintenance 16 Troubleshooting 18 SS Warranty 19

Introduction. Earlier. To Scales. We talked about. L Dimensions

How Accurate is Your Micrometer?

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

Metallic materials Knoop hardness test. Part 1: Test method. Matériaux métalliques Essai de dureté Knoop Partie 1: Méthode d'essai

Conversion Kit for: 7620 and 7820 Swing-Out Valves ft-lbs ft-lbs 8835/ ft-lbs

2 - Machining Fundamentals Measurement. Manufacturing Processes - 2, IE-352 Ahmed M El-Sherbeeny, PhD Spring-2015

/2" Heavy Duty Swing-Out

Premier Heritage 3-15X50 User Manual

METHOD FOR MEASURING PAVEMENT LIFT THICKNESS

PARTS CATALOGUE / TECHNICAL GUIDE Cal. 4F32A, 8F32A Cal. 8F33A, 8F35A

Sensor Accessories. Rotary Motion Accessory Pack. Pendulum Rod with two masses, Angular Momentum disc set and Linear Rack with mini c-clamp

MANUAL TT-220 TT-220

Must Read Before Installation TadPoleTM Safety and Warnings

RT-6 Riflescopes. User Guide

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

EE 1/3.5х14 U EE 1/3.5х14 U

Owner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free:

LINEAR AND ANGULAR MEASUREMENTS

INSTALLING TRAK SPORT TIRE CHAINS ON 20 MODEL 3 TIRES

1-6 x 24 Second Focal Plane MOA

Errors in Measurement. ME 338: Manufacturing Processes II Instructor: Ramesh Singh; Notes: Profs. Singh/Melkote/Colton

PARTS LIST / TECHNICAL GUIDE

Important Instructions

Measurement of basic constants: length, weight and time

Second Focal Plane MRAD

State Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant PN-6K. Servise Manual

C4 PLUS RIFLESCOPES User Guide

Q11: WHAT IS A MEANT GOOD ELECTRICAL CONNECTION?

Flexbar 6.3:1 MANUAL ZOOM STEREO MICROSCOPE. 250 Gibbs Road, Islandia, NY (P) (F)

The Vortex Razor HD Gen II-E 1 6x24 Riflescope

SMD Switch SI-C3436A General specification. Soldering conditions Reflow Soldering condition. Standard Reel Dimensions (mm) Packing specification

Engineering Metrology and Instrumentation

ISSPRO 3 3/8 Programmable Tachometer High Performance EV Line Part Numbers R5535M, R6535M

AUR30405 CERTIFICATE III IN AUTOMOTIVE MECHANICAL TECHNOLOGY

2. OPERATIONAL CONDITIONS

Telescope. 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit.

DWT-10 Instruction Manual

Responsibilities: Effective Date: November Revision Date: February 8, VP, Facilities and Construction Management. Issuing Authority:

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

SIR C.R.REDDY COLLEGE OF ENGINEERING ELURU

User Manual for Blackhawk Riflescope

Operating Manual 1.1-4x24 Zenith x24 Zenith

External Micrometers. C-1

P4Xi TACTICAL Riflescope TECHNICAL MANUAL

x Builders Level Service Manual

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

Appendix. Physical Constants. Micrometer

THE MICROMETER Name Date Objectives: Students will familiarize themselves with the micrometer and accurately read measurements.

EPOCSELFIR LACITCATiX5T TECHNICAL MANUAL

product manual H-3220A Benkelman Beam

ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook

Standard Test Methods for Thickness of Solid Electrical Insulation 1

Designation: D (Reapproved 2009)

The Vortex Razor HD Gen II 1 6x24 Riflescope

SK Series BOX PLOW INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Hey, that wasn t so hard. INSTRUCTION MANUAL AND WARRANTY

Service Information Letter SIL # 017

Z650HR SERIES MANUAL ZOOM STEREO MICROSCOPE. 73 Mall Drive, Commack, NY (P) (F)

THE FIFTH ELEMENT USER INSTRUCTIONS

Ballistic pendulum Operating Instructions Fig. 1: Ballistic pendulum SAFETY PRECAUTIONS

Volkswagen of America, Inc. Service Training Printed in U.S.A. Printed in 4/2001 Course Number Volkswagen of America, Inc.

4-14X44 FRONT FOCAL PLANE SCOPE WITH ARC-2 MOA RETICLE

Read the following BEFORE getting started:

COMMON MISTAKES IN DIMENSIONAL CALIBRATION METHODS

Measurement devices. Kalevi Aaltonen, Aalto University

Wenzhou Tripod Instrument Manufacturing Co., Ltd.

TEST METHOD FOR DETERMINING BREAKAWAY FORCE OF A MAGNET

Automatic Level NP-732

Observations with the Meade LX-10 Telescope (Evening Observation)

SpecterOS3.0 Optical Sight Operation Manual

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

Transcription:

Table of Contents Page 1. Scope 2 2. Objective 2 3. Definitions 2 4. Responsibility 3 5. Procedure 4 6. Precautions 12 7. References 12 8. Appendices 13 9. Revision History 13 Original Authorised Copy for: Reading Copy Written by: Reviewed by: Approved by: Signature/Date: Signature/Date: Signature/Date: Page 1 of 13

1. Scope This Standard Operating Procedure (SOP) applies to the staff and students using the Draper External Micrometer in the laboratories of the Pharmacy Department, University of Malta. 2. Objective To describe the procedure for the operation, calibration and maintenance of the Draper External Micrometer. 3. Definitions 3.1. Adjusting Wrench: Contains two small protrusions used to appropriately adjust the barrel and the ratchet through their two small orifices 3.2. Anvil: The fixed portion on which the object to be measured rests against when the spindle moves towards it. 3.3. Barrel: The stationary round part of the micrometer that contains the linear scale. This scale is divided into 25mm divisions that are separated from further subdivisions of ½ mm each by the reference line. 3.4. External Micrometer: An instrument that accurately measures the outside diameter, length and thickness of small objects. The measured size of the object to be measured is the distance between the spindle and the anvil when they are just in contact with the sides of the object. 3.5. Frame: Holds the anvil and the spindle in constant relation to each other. 3.6. Heat Isolation Plate: Prevents heat transfer from the hands of the operator to the micrometer. 3.7. Lead Error: The difference between the actual value of the gauge block and the observed reading during the calibration process. Page 2 of 13

3.8. Lock Nut: A device to lock the spindle in its exact position allowing correct readings to be taken without altering the distance between the two measuring faces, thus retaining perfect alignment. 3.9. Primary Pointer: The zero mark on the thimble scale. When this lines up with the central reference line of the barrel scale, the distance between the anvil and the spindle is exactly an integral or a halfintegral number of millimetres. 3.10. Ratchet: Allows the instrument to have just enough torque to rotate the thimble in a gentle manner thus preventing damage to the spindle / anvil mechanism and to the object being measured. This also prevents inaccurate readings from being obtained since the micrometer will not continue to advance once sufficient resistance is encountered. 3.11. Spindle: Moves towards the object to be measured to hold it in place as the ratchet is rotated. 3.12. Thimble: The rotating part of the micrometer that contains the fine scale. This scale is divided into 50 divisions where each division represents 0.01mm (i.e. one revolution equals 0.5mm). 3.13. Zero Point Alignment: When the primary pointer on the thimble scale is in line with the reference line of the barrel scale whenever the spindle is rotated until it makes contact with the anvil. 4. Responsibility 4.1. The members of the Department of Pharmacy (staff and students) are responsible for following this SOP. 4.2. The designated Laboratory Officer or Laboratory Assistant is responsible for ensuring that this SOP is followed Page 3 of 13

5. Procedure 5.1. Diagram of an External Micrometer Anvil Spindle Lock Nut Barrel Thimble Ratchet Frame Heat Isolation Plate 5.2. Operation 5.2.1. Keep the micrometer in stable room temperature before starting the measuring process. 5.2.2. Hold the micrometer from its heat isolation plate. 5.2.3. Rotate the ratchet anticlockwise allowing sufficient space between the anvil and the spindle to accomodate the object to be measured. 5.2.4. Place the object to be measured between the anvil and the spindle. 5.2.5. Spin the ratchet clockwise until the spindle just meets the object. 5.2.6. Keep spinning the ratchet gently until 3 clicks are heard. 5.2.7. Check that both the anvil and the spindle are touching the object evenly. 5.2.8. Set the lock nut while the micrometer is still on the object. 5.2.9. Remove the object from the micrometer. 5.2.10. Read off the value from the barrel scale to obtain reading to the nearest half millimetre. 5.2.11. Read off the value from the thimble scale that is parallel with the reference line of the barrel scale. 5.2.12. Add both values obtained from 5.2.10. and 5.2.11. to obtain the total measurement reading. Page 4 of 13

5.2.13. Micrometer reading example EXAMPLE 1 Barrel scale reads= 12.50mm Thimble scale reads= 0.16mm Total Measurement = 12.66mm EXAMPLE 2 Barrel scale reads = 16.00mm Thimble scale reads = 0.355mm Total Measurement = 16.355mm 5.2.14. Reset the lock nut to the unlock position. 5.2.15. Turn the ratchet clockwise to slightly close the micrometer prior to its storage. 5.3. Calibration 5.3.1. Obtain standard gauge blocks. 5.3.2. Keep the micrometer in stable room temperature before starting the calibration process. 5.3.3. Hold the micrometer from its heat isolation plate. 5.3.4. Move the spindle towards the anvil until they make contact to check that the primary pointer on the thimble scale is in line with the reference line of the barrel scale. If not so, use the adjusting wrench to achieve this zero point alignment. 5.3.5. Spin the ratchet anticlockwise until enough space is present between the anvil and the spindle to accomodate the gauge block. 5.3.6. Place the gauge block between the anvil and the spindle. 5.3.7. Spin the ratchet clockwise until the spindle just meets the gauge block. 5.3.8. Keep spinning the ratchet gently until 3 clicks are heard. 5.3.9. Check that both anvil and spindle are touching the gauge block evenly. Page 5 of 13

5.3.10. Set the lock nut while the micrometer is still on the gauge block. 5.3.11. Read off the value from the barrel scale to obtain a reading to the nearest half millimetre. 5.3.12. Read off the value from the thimble scale that is parallel with the reference line of the barrel scale. 5.3.13. Add both values obtained from 5.3.11. and 5.3.12. to obtain the total measurement reading. 5.3.14. Compare the reading obtained with the actual value of the gauge block to determine whether a lead error exists. 5.3.15. Repeat the calibration procedure with different successive gauge blocks to calibrate the micrometer at several points throughout its range. If reading varies by more than +/- 0.0003mm to 0.0005mm: 5.3.16. Record this lead error. 5.3.17. Compensate any readings obtained with the micrometer by this relevant lead error if micrometer cannot be immediately replaced of repaired. 5.4. Maintenance 5.4.1. Inspect the micrometer for any signs of damage, such as indications that it might have been dropped. 5.4.2. Check that both spindle and anvil tips are flat, free from scratches, dents and chipped edges. 5.4.3. Move the thimble through its entire range (i.e. 25mm) to check that it moves smoothly. 5.4.4. Perform the zero point alignment test (see 5.3.4). To clean the tips of the anvil and the spindle: 5.4.5. Rub off any visible dirt, dust and grit with a lint free cloth. 5.4.6. Close the micrometer all the way with a piece of paper clamped in between. 5.4.7. Pull the paper out whilst rubbing the tips of the spindle and the anvil clean. Page 6 of 13

5.5. Average time taken to carry out Procedure Procedure Section Average Time (mins) Operation 1.5 (for one measurement) Calibration 2 (for one-point calibration) Maintenance N/A 5.6. Flow Charts 5.6.1. Operation Start Keep micrometer in stable room temperature before starting measuring process Hold micrometer from its heat isolation plate Rotate ratchet anticlockwise allowing sufficient space between anvil and spindle to accommodate object to be measured Place object to be measured between anvil and spindle Spin ratchet clockwise until spindle just meets object Keep spinning ratchet gently until 3 clicks are heard Check that both anvil and spindle are touching object evenly Set lock nut 1 Page 7 of 13

1 Remove object from micrometer Read off value from barrel scale to obtain a reading to the nearest half millimetre Read off value from thimble scale that is parallel with reference line of barrel scale Add up values obtained from the barrel and thimble scales respectively to obtain total measurement reading Reset lock nut to the unlock position Turn ratchet clockwise to slightly close micrometer prior to its storage End Page 8 of 13

5.6.2. Calibration Start Obtain standard gauge blocks Keep micrometer in stable room temperature before starting calibration Hold micrometer from its heat isolation plate Move spindle towards anvil until they make contact with each other Primary pointer on thimble scale in line with reference line of barrel scale No Use adjusting wrench to adjust barrel until this is achieved 2 Yes Spin ratchet anticlockwise until enough space is present between anvil and spindle to accommodate gauge block Place desired gauge block between anvil and spindle Spin ratchet clockwise until spindle just meets gauge block Continue to gently spin ratchet until 3 clicks are heard Check that both anvil and spindle are touching gauge block evenly Set lock nut 1 Page 9 of 13

1 Read off value from barrel scale to obtain reading to the nearest half millimetre Read off value from thimble scale that is parallel with reference line of barrel scale Add up values obtained from the barrel and thimble scales respectively to obtain total measurement reading Compare reading obtained with actual value of gauge block Reading varies by > /- 0.0003mm to 0.0005mm No Repeat calibration with different gauge block/s No Yes Record this lead error Yes 2 Can micrometer be immediately changed or repaired No Compensate any readings obtained with micrometer with this relevant lead error Yes Change or repair micrometer End Page 10 of 13

5.6.3. Maintenance Start Inspect micrometer for any signs of damage Check that both spindle and anvil tips are flat, free from scratches, dents and chipped edges Move thimble through its entire range to check that it moves smoothly Move spindle towards anvil until they make contact with each other Primary pointer on thimble scale in line with reference line of barrel scale No Use adjusting wrench to adjust barrel until this is achieved Yes Tips of anvil and/or spindle need/s cleaning No Yes Rub off any visible dirt, dust and grit with a lint free cloth Close micrometer all the way with a piece of paper clamped in between Pull paper out whilst rubbing tips of spindle and anvil clean End Page 11 of 13

6. Precautions 6.1. The micrometer is a highly heat sensitive instrument and should be stored at room temperature. 6.2. Hold the micrometer from its heat isolation plate whilst handling to prevent heat transfer from hand of user to the micrometer. 6.3. The object to be measured should also be kept at room temperature since this may also affect the reading. 6.4. Do not overtighten the micrometer as this can lead to deformation of both the anvil and spindle and the object being measured. 6.5. Store the micrometer in its appropriate storage compartment to prevent any wearing of the anvil and/or spindle. 6.6. Store the micrometer with the anvil and spindle not in contact with each other so that any temperature fluctuations will not stress the instrument. 6.7. Measure the desired object a number of times to ensure that the reading obtained is accurate. 6.8. Do not operate abruptly, drop or strike the micrometer. 7. References Anon. Calibration of gages. Long Island Indicator Service Inc [Online] 2010 Oct 15 [cited 2010 Dec 14]. Available from: URL: http://longislandindicator.com/p7.html#outsidemicrometers. Bewoor AK, Kulkarni VA. Metrology and Measurement. New Delhi: Tata McGraw-Hill; 2009. p. 59-73. Campbell PDQ. An Introdution to Measuration and Calibration. New York: Industrial Press Inc; 1995. p. 29-38. Harrison DM. The Micrometer. University of Toronto Department of Physics [Online] 2005 Feb 19 [cited 2010 Dec 28]. Available from: URL: http://www.upscale.utoronto.ca/pvb/harrison/micrometer/micrometer.html. Kennedy CW, Hoffman EG, Bond SD. Inspection and Gaging. 6 th ed. New York: Industrial Press Inc; 1987. p. 188-203. Page 12 of 13

Suga N. Quality 101: Calibrating Micrometer. Mitutoyo Institute of Metrology [Online] 2004 Apr 1 [cited 2010 Dec 14]. Available from: URL: http://www.qualitymag.com/cda/archives/992adc57f6c38010vgnvcm1000 00f932a8c0. 8. Appendices N/A 9. Revision History Version Number Amendments/ Reasons for change 01 Initial Release Page 13 of 13