Structural characterization begins with a purity check!

Similar documents
Chromatography & instrumentation in Organic Chemistry

Chapter 26. An Introduction to Chromatographic Separations. Chromatography

AOAC Official Method 2016.xx. Determination of Total Sulfur in Fertilizers by High Temperature Combustion

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

Thin Layer Chromatography

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Principles of Gas- Chromatography (GC)

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

Chromatography. Gas Chromatography

Chromatography 1 of 26 Boardworks Ltd 2016

Chromatography Lab # 4

Physical Separations and Chromatography

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

Chromatography: Thin-Layer Chromatography (TLC) & Column Chromatography

CK-12 FOUNDATION. Separating Mixtures. Say Thanks to the Authors Click (No sign in required)

Open Column Chromatography, GC, TLC, and HPLC

Mixtures 1 of 38 Boardworks Ltd 2016

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Chromatography and Functional Group Analysis

5072 CHEMISTRY (NEW PAPERS WITH SPA) TOPIC 1: EXPERIMENTAL CHEMISTRY 5067 CHEMISTRY (NEW PAPERS WITH PRACTICAL EXAM) TOPIC 1: EXPERIMENTAL CHEMISTRY

Exp t 125. Oxidation of Borneol to Camphor. Reduction. Camphor. Borneol. Isoborneol

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

EXPERIMENT #1 SEPARATION AND RECOVERY OF ORGANIC COMPOUNDS, THIN LAYER CHROMATOGRAPHY, COLUMN CHROMATOGRAPHY, CRYSTALLIZATION AND MELTING POINTS

Volumetric Analysis. Quantitative analysis answers the second question

Specimen. Date Morning/Afternoon Time allowed: 1 hour 30 minutes. AS Level Chemistry B (Salters) H033/02 Chemistry in depth Sample Question Paper PMT

Introduction to Pharmaceutical Chemical Analysis

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

LAB #6 Chromatography Techniques

CfE Higher Chemistry. Unit 3: Chemistry in Society. Chemical Analysis as part of quality control

Matter is anything that has mass and occupies space. Three physical states of matter

ICSE Board. Class X Chemistry. Board Paper Time: 1½ hrs Total Marks: 80

Chemical Processes Part 1: Intro and Chemistry Basics

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Experiment 1: Extraction and Thin Layer Chromatography

AP Chemistry A Review of Analytical Chemistry

Chemistry Final Exam Sample Items

Name Period Date. Lab 10: Paper Chromatography

Aspirin Synthesis H 3 PO 4

CHEMISTRY. SCIENCE Paper 2

Class XI Chapter 1 Some Basic Concepts of Chemistry Chemistry

Methods of Separation. Vacuum Filtration. Distillation. The Physical Separation of Matter Chemistry 11 2/17/2014

FLUDEOXYGLUCOSE ( 18 F) INJECTION: Final text for addition to The International Pharmacopoeia (January 2009)

THIN LAYER CHROMATOGRAPHY

For Chromatography, you might want to remember Polar Dissolves More, not like dissolves like.

Spectroscopy and Chromatography

Worksheet 1.1. Chapter 1: Quantitative chemistry glossary

Q1. Methane and oxygen react together to produce carbon dioxide and water.

Chapter 3 Stoichiometry

Method for the determination of 1,3-butadiene

1. (a) The diagrams below show the arrangement of atoms or molecules in five different substances A, B, C, D and E.

SEPARATION TECHNIQUES

Lab #3 Reduction of 3-Nitroacetophenone

Unit 08 Review: The KMT and Gas Laws

Experiment 1: Thin Layer Chromatography

PAPER AND THIN LAYER CHROMATOGRAPHY (TLC)

Rule 2. Rule 1. Rule 4. Rule 3. Rule 5. Rule 6. Rule 7. Rule 8

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Test Booklet. Subject: SC, Grade: HS CST High School Chemistry Part 2. Student name:

Chromatography. writing in color

Chromatography. What is Chromatography?

Chromatographic Methods of Analysis Section 2: Planar Chromatography. Prof. Tarek A. Fayed

Chapter 31 Gas Chromatography. Carrier Gas System

CHROMATOGRAPHY, AND MASS SPECTRAL. FRACTIONS OF Lasianthus

Experiment 7: Synthesis of an Alkyne from an Alkene

Elemental Analysis: CHNS/O characterization of polymers and plastics

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Basic Digestion Principles

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

States of matter

Laboratory Exercise: Chromatographic Separation

CHEMISTRY 2202 FINAL EXAMINATION Value: 100% General Instructions

(i) The atomic number of an atom is the number of... (ii) The mass number of an atom is the number of...

Allotropes (Diamond and Graphite) Revision Pack (C3)

Sodium Borohydride Reduction of Benzoin

High Pressure/Performance Liquid Chromatography (HPLC)

for sodium ion (Na + )

Experiment Nine Thin Layer Chromatography

CHAPTER 6 GAS CHROMATOGRAPHY

TECHNICAL TEMEPHOS. 1. Specification. Full specification WHO/SIT/19.R4 Revised 10 December Description

costech instruments ECS 4010 Elemental Combustion System CHNS-O

CHEMISTRY HIGHER LEVEL

UW Department of Chemistry Lab Lectures Online

Chapter 27: Gas Chromatography

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certifi cate of Education Advanced Subsidiary Level and Advanced Level

18 Macroscale and Microscale Organic Experiments

CHEM 429 / 529 Chemical Separation Techniques

ASSORTED STOICHIOMETRY PRACTICE PROBLEMS PART I

Determination of Physical Properties of Organic Compounds

A covalent bond is a shared pair of electrons between atoms of two non-metal elements.

SPECIMEN. Date Morning/Afternoon Time allowed: 1 hour 30 minutes. AS Level Chemistry B (Salters) H033/02 Chemistry in depth Sample Question Paper

Ondansetron Hydrochloride Tablets

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Abstract. Introduction

Product Information. Silicon Carbide Well Plates

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Covalent (sharing of electron pairs) Ionic ( electrostatic attraction between oppositely charged ions)

Chemistry Gas Chromatography: Separation of Volatile Organics

EXPERIMENT 7 Reaction Stoichiometry and Percent Yield

Lab.2. Thin layer chromatography

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Transcription:

Structural characterization begins with a purity check! Refractive Index Melting Point Elemental Analysis (EA) Thin Layer Chromatography (TLC) High Performance Liquid Chromatography (HPLC) Course: 59-320 Analytical Chemistry, R. Letcher Gas Chromatography (GC) only for volatile compounds Course: 59-320 Analytical Chemistry, R. Letcher Other chromatographic or electrophoretic methods

Purity of commercially available reagents and solvents Most reagents come in purities between 95 % and 99 % (by weight or volume). The price of a chemical can increase significantly if high purity is requested. Example (Aldrich prices): 500 g of PBr 3 99.99 % = $1931 99 % = $188 97 % = $119 A real chemical/material can not be pure and the preparation of highly purified chemicals is tedious and consumes time. Consequently, it is crucial to decide what degree of purity is required for a specific experiment. It is important to know what impurities contaminate the sample to predict whether they will interfere with a certain reaction or with a physical measurement, such as a spectroscopic investigations. These details are provided by the manufacturer or distributor.

Refractive index (n) of liquids/solvents The purity of a liquid (solvent) is usually determined by GC and/or its refractive index n. The refractive index (n) is the ratio of the velocity of light in a vacuum to the velocity in some medium. Refractive indices generally increase with the atomic number of the constituent atoms. A high density or high atomic number elements usually results in high refractive indices. Abbe Refractometer Medium refractive index of a vacuum refractive index of air refractive index of ice refractive index of a water (20 ºC) Refractive Index 1.0 (exactly) 1.0003 1.31 1.33 Digital Laboratory Refractometer refractive index of glass iodine crystal 1.5 3.34

Refraction and the refractive index When light enters a transparent medium of different refractive index, n, it is refracted (Snell s Law): n = sinθ 1 / sinθ 2 (angle of incident & refraction) sinθ 1 / sinθ 2 = n 2 / n 1 The velocity of a light wave changes when light enters a transparent medium of different refractive index but not the frequency: velocity = νλ; n = c / v = λ vac / λ subs

Molecular Theory of Refractive Indices Lorentz local field for an isotropic medium: E loc = [(ε + 2) / 3] E where ε is the mean permittivity Using ε = n 2 derived from the Maxwell s Equations, the Lorenz-Lorentz expression relates the refractive index to the mean molecular polarizability: n 2 1 / n 2 + 2 = N α / 3ε 0 where N is the number density (d N A / M ), α the mean molecular polarizability, and ε 0 = 8.86 10-12 As/Vm n e2 1 / n 2 + 2 = N α / 3ε 0 n o2 1 / n 2 + 2 = N α / 3ε 0 with n 2 = 1/3 (n e2 + 2n o2 )

Melting Points of Solids Freezing Point Melting Point The melting point of a substance is sensitive to its composition (freezing point depression T f = -K f m). Measuring the melting point of a chemical is and easy and powerful method for determining its identity and purity, if reference values are available. The melting point (freezing point) of a substance is defined as the temperature at which the solid and liquid form of the substance can co-exist.

MELTING POINTS are measured with a melting point apparatus. The sample is first heated at several K a minute until the solid is molten. This crude melting temperature is now determined more accurately by using a slow heating rate (2 K / min). The temperature at which the edges of a solid start to melt is defined as on-set temperature and the final melting temperature is reached when all the solid has become a liquid. The exact melting temperature is in between these two temperatures and is reached when both phases, the solid and the liquid, are present at the same time. Determination of a mixed melting point The melting point of an unknown compound is determined to 99.5 ºC and a reference table (e.g. from the Handbook of Chemistry and Physics) suggests 8 possible compounds. If we assume malic acid might be the unknown compound, we first determine the m.p. of the pure malic acid (about 100.1 ºC ). Both compounds are then mixed and run again. The melting point does not change if both compounds are identical.

Thin Layer Chromatography (TLC) A small amount of the compound under investigation, or its solution in a volatile solvent, is spotted onto a substrate that is coated with an active stationary phase such as silica gel. One side of the substrate, the spotted side, is then exposed to a solvent that runs up the plate due to capillary forces. Compounds run with the solvent but might be slowed down by interactions with the stationary phase. The ratio between the distance one spot runs and the distance the solvent front runs is given as R f values (retention factor). Optimum R f values are between 0.1 and 0.5 (1.0 = solvent front). Good separations are obtained only if the right combination of solvent and stationary phase has been chosen. A polar stationary phase (silica gel) is available in the labs and the least polar organic solvent that runs your compounds should be chosen. Generally, polar solvents for used for non-polar stationary phases and vice versa. Three common stationary phases are silica, aluminum oxide, and reverse phases such as RP-18. A solvent must also dissolve your sample well enough. Streaking spots appear if the solubility of your compounds is not high enough.

Elemental Analysis (EA) Elemental analysis on carbon, hydrogen, and nitrogen is the oldest investigation performed to characterize and/or prove the elemental composition of an organic or inorganic sample. In fact, it used to be the only available routine method before modern spectroscopy was established in the 1950s. The majority of organic compounds only contain the elements C, H, N, and O and the latter is seldom determined separately. Our departmental analyser gives weight percentages of C, H, N done by combustion in O 2 and gas chromatographic analysis of CO 2, H 2 O and NO 2. As an option S can be measured as SO 2 and oxygen as CO. Other elements such as Cl, Br, and I must be determined by other means. Perkin Elmer 2400 Series II CHNS/O Analyzer

Measuring Principle The sample under test is weighed in using a tin capsule. The required amount is 2 to 3 mg of organic material and can hardly exceed 10 mg, if inorganic matter with little carbon content is investigated. After folding the capsule (looking rather like wrapped tin foil) the sample is placed in the autosampler. The tin capsule enclosing the sample falls into the reactor chamber where excess oxygen is introduced before. At about 990 C the material is "mineralized". Formation of carbonmonoxide is probable at this temperature even under these conditions of excess oxygen. The complete oxidation is reached at a tungsten trioxide catalyst which is passed by the gaseous reaction products. The resulting mixture should thus consist of CO 2, H 2 O und NO x. But also some excess O 2 passes the catalyst. The product gas mixture flows through a silica tube packed with copper granules. In this zone, held at about 500 C, remaining oxygen is bound and nitric/nitrous oxides are reduced to N 2. The leaving gas stream includes the analytically important species CO 2, H 2 O und N 2. Eventually included SO 2 or hydrohalogenides are absorbed at appropriate traps.

High purity helium (Quality 5.0) is used as carrier gas. Finally the gas mixture is brought to a defined pressure/volume state and is passed to a gas chromatographic system. Separation of the species is done by so called zone chromatography. In this technique a staircase type signal is obtained and the step height is proportional to the substance amount in the mixture. Blank values are taken from empty tin capsules Calibration is done by elemental analysis of standard substances supplied by the instrument's manufacturer for this purpose. Working Range Mineralization and detection covers every species of the analyte elements in the sample. Beside purely organic samples various metal organic compunds and even inorganic samples as carbides and nitrides have successfully been characterized. The detection limit for carbon and nitrogen at sample amounts of 2 to 3 mg was found to be at about 0.05 w-% (500 ppm) in what case the uncertainty stays at about 0.02 w-%. According to the apparatus's supplier the instrument's uncertainty in the medium range stays below 0.3 w-% as required by journals to prove the expected composition. With very carbon rich samples we found this tolerance was slightly exceeded (still within 0.5 w-%).

Problems and Interferences The weighing of oily or fluid substances is impossible using the thin walled tin capsules. For this purpose alumina pans with a lid are available. These pans are tightly closed by cold welding to prevent loss of sample by spillage and evaporation. As the blank value for nitrogen is dramatically increased be the enclosed volume of air the determination limit for N in liquid samples is increased to 0,1 to 0,2 w-%. With highly viscous or even glassy materials elemental analysis is even impossible with the above method. It has long been known that phosphorus can interfere in the mineralization of organic material. In literature the formation of glassy P 2 O 5 xh 2 O yc has been described. Elemental analysis of phosphorus containing compounds can thus suffer from systematic deviations in the determined carbon content exceeding the tolerance limit of 0,3 w-%. This effect can be controlled by the addition of vanadium pentoxide (V 2 O 5 ). Fluorine is mineralized to form HF which reacts at the wall of the silica tubes which form the main part of the reaction zone. The gaseous products, such as SiF 4 and relatives, can cause systematic errors which rarely become significant with respect to the 0,3 w-% tolerance. The mineralization of metal containing samples can also be affected by interferences. By modification of the method most of these can be compensated for.

Example Calculations Percentage Composition C x H y O z (9.83 mg) + excess O 2 gives CO 2 (23.26 mg) + y/2 H 2 O (9.52 mg) Calculations: 23.26 mg of CO 2 / 44.01 mg/mmol = 0.5285 mmoles of CO 2 mmoles of CO 2 = mmoles of C in original sample (0.5285 mmoles of C)(12.01mg/mmol C) = 6.35 mg of C in original sample 9.52 mg of H 2 O / 18.02 mg/mmol = 0.528 mmoles of H 2 O mmoles of H 2 O = 1/2 mmoles of H in original sample (0.528 mmoles of H) (2) (1.008mg/mmol H) = 1.06 mg of H in original sample

Weight Percentage Composition C x H y O z (9.83 mg) + excess O 2 x CO 2 (23.26 mg) + y/2 H 2 O (9.52 mg) %C = 6.35 mg/9.83 mg x 100 = 64.6% %H = 1.06 mg/9.83 mg x 100 = 10.8% %O = 100-(64.6 + 10.8) = 24.6% Calculation of Empirical Formula assume for example a 100g sample 64.6% of C: 64.6 g/12.01 g/mol = 5.38 moles of C 10.8% of H: 10.8 g/1.008 g/mol = 10.7 moles of H 24.6% of O: 24.6 g/16.0 g/mol = 1.54 moles of O Thus: C5.38 H10.7 O1.54 converting to simplest ratio: C5.38/1.54; H10.7/1.54; O1.54/1.54 C 3.50 H 7.00 O 1.00 = C 7 H 14 O 2 What are theoretically possible structures?