BORON IN GLASS DETERMINATION USING WDXRF

Similar documents
RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD

MEASUREMENT CAPABILITIES OF X-RAY FLUORESCENCE FOR BPSG FILMS

FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS

S8 TIGER Series 2 for ASTM D 6443

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA

MS482 Materials Characterization ( 재료분석 ) Lecture Note 4: XRF

A COMPACT X-RAY SPECTROMETER WITH MULTI-CAPILLARY X-RAY LENS AND FLAT CRYSTALS

ULTRATHIN LAYER DEPOSITIONS A NEW TYPE OF REFERENCE SAMPLES FOR HIGH PERFORMANCE XRF ANALYSIS

FUNDAMENTAL PARAMETERS ANALYSIS OF ROHS ELEMENTS IN PLASTICS

Elemental analysis by X-ray f luorescence. Sequential benchtop WDXRF spectrometer

ADVANTAGES AND DISADVANTAGES OF BAYESIAN METHODS FOR OBTAINING XRF NET INTENSITIES

ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS

Time-Resolved μ-xrf and Elemental Mapping of Biological Materials

IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER

EFFECT OF CALIBRATION SPECIMEN PREPARATION TECHNIQUES ON NARROW RANGE X-RAY FLUORESCENCE CALIBRATION ACCURACY

INFLUENCE OF GROWTH INTERRUPTION ON THE FORMATION OF SOLID-STATE INTERFACES

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS

ACCURATE QUANTIFICATION OF RADIOACTIVE MATERIALS BY X-RAY FLUORESCENCE: GALLIUM IN PLUTONIUM METAL

PERFORMANCE OF A ROOM TEMPERATURE GAS PROPORTIONAL SCINTILLATION COUNTER IN X-RAY ANALYSIS OF METALLIC ALLOYS EXCITED WITH ALPHA PARTICLES

USABILITY OF PORTABLE X-RAY SPECTROMETER FOR DISCRIMINATION OF VALENCE STATES

BENEFITS OF IMPROVED RESOLUTION FOR EDXRF

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

FUNDAMENTAL PARAMETER METHOD FOR THE LOW ENERGY REGION INCLUDING CASCADE EFFECT AND PHOTOELECTRON EXCITATION

Overview of X-Ray Fluorescence Analysis

ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION

SEM. Chemical Analysis in the. Elastic and Inelastic scattering. Chemical analysis in the SEM. Chemical analysis in the SEM

Praktikum zur. Materialanalytik

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Issues With TXRF Angle Scans and Calibration

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

MATERIALS CHARACTERIZATION USING A NOVEL SIMULTANEOUS NEAR-INFRARED/X-RAY DIFFRACTION INSTRUMENT

IMPROVEMENT OF DETECTION LIMITS OF A PORTABLE TXRF BY REDUCING ELECTRICAL NOISE

XUV 773: X-Ray Fluorescence Analysis of Gemstones

Standardless Analysis by XRF but I don t know what s in my sample!! Dr Colin Slater Applications Scientist, XRF Bruker UK Limited

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

APPLICATION OF MICRO X-RAY FLUORESCENCE SPECTROMETRY FOR LOCALIZED AREA ANALYSIS OF BIOLOGICAL AND ENVIRONMENTAL MATERIALS

FACTORS AFFECTING IN-LINE PHASE CONTRAST IMAGING WITH A LABORATORY MICROFOCUS X-RAY SOURCE

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS

X-RAY MICRODIFFRACTION STUDY OF THE HALF-V SHAPED SWITCHING LIQUID CRYSTAL

Infrastructure of Thin Films Laboratory in Institute of Molecular Physics Polish Academy of Sciences

Silicon Drift Detectors: Understanding the Advantages for EDS Microanalysis. Patrick Camus, PhD Applications Scientist March 18, 2010

ED(P)XRF: SCREENING ANALYSIS AND QUANTITATIVE ANALYSIS with POLARIZED

Quantitative XRF Analysis. algorithms and their practical use

EDS User School. Principles of Electron Beam Microanalysis

In-Situ Analysis of Traces, Minor and Major Elements in Rocks and Soils with a Portable XRF Spectrometer*

CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE

OXEA - Online Elemental Analyzer

In Situ High-Temperature Study Of Silver Behenate Reduction To Silver Metal Using Synchrotron Radiation

Electron-Induced X-Ray Intensity Ratios of Pb Lα/Lβ and As Kα/Kβ by kev Applied Voltages

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

LAB 01 X-RAY EMISSION & ABSORPTION

ION-EXCHANGE FILMS FOR ELEMENT CONCENTRATION IN X-RAY FLUORESCENCE ANALYSIS WITH TOTAL REFLECTION OF THE PRIMARY BEAM.

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

MICRO-TOMOGRAPHY AND X-RAY ANALYSIS OF GEOLOGICAL SAMPLES

STRESS ANALYSIS USING BREMSSTRAHLUNG RADIATION

X-Ray Fluorescence and Natural History

AN EXAFS STUDY OF PHOTOGRAPHIC DEVELOPMENT IN THERMOGRAPHIC FILMS

Horst Ebel, Robert Svagera, Christian Hager, Maria F.Ebel, Christian Eisenmenger-Sittner, Johann Wernisch, and Michael Mantler

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

REALIZATION OF AN ASYMMETRIC MULTILAYER X-RAY MIRROR

MSE 321 Structural Characterization

1 of 5 14/10/ :21

Pros and Cons of Water Analysis Methods

AN IMPROVED AEROSOL GENERATION SYSTEM FOR THE PREPARATION OF XRF CALIBRATION FILTERS

QUANTITATIVE ENERGY-DISPERSIVE ELECTRON PROBE X-RAY MICROANALYSIS OF INDIVIDUAL PARTICLES

An Analysis of Secondary Enhancement Effects in Quantitative XRFA

X-ray Absorption Spectroscopy

PHYS General Physics II Lab The Balmer Series for Hydrogen Source. c = speed of light = 3 x 10 8 m/s

DATA MINING WITH DIFFERENT TYPES OF X-RAY DATA

Portable type TXRF analyzer: Ourstex 200TX

Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy

Chemical State Analysis of SiO 2 /Si by Wavelength-Dispersive X-Ray Fluorescence

XRF books: Analytical Chemistry, Kellner/Mermet/Otto/etc. 3 rd year XRF Spectroscopy Dr. Alan Ryder (R222, Physical Chemistry) 2 lectures:

FINDING DESCRIPTORS USEFUL FOR DATA MINING IN THE CHARACTERIZATION DATA OF CATALYSTS

EUV-Technology with Discharge EUV-Lamp"

X-rays. X-ray Radiography - absorption is a function of Z and density. X-ray crystallography. X-ray spectrometry

Automated Determination of Crystal Reflectivity in the X-ray Laboratory

Introduction to Fourier Transform Infrared Spectroscopy

2D XRD Imaging by Projection-Type X-Ray Microscope

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

Multi-element process analyzer

D y n a m a r. Polymer Processing Additives. Analysis of Dynamar Polymer Processing Additives in Polyolefins Using X-ray Fluorescence Spectrometry

Reversible uptake of HgCl 2 in a porous coordination polymer based on the dual functions of carboxylate and thioether

X-Ray Emission and Absorption

X-RAY EMISSION WAVELENGTHS AND KEV TABLES FOR NONDIFFRACTIVE ANALYSIS

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Ziessel a* Supporting Information (75 pages) Table of Contents. 1) General Methods S2

QUANTIFICATION OF MERCURY, LEAD, AND CADMIUM IN AQUEOUS SOLUTIONS BY ENERGY K X-RAY FLUORESCENCE SPECTROSCOPY

Improvements for Absorption Spectroscopy at Beamlines A1, E4, X1

CHARACTERIZATION OF Pu-CONTAINING PARTICLES BY X-RAY MICROFLUORESCENCE

Transcription:

269 ABSTRACT BORON IN GLASS DETERMINATION USING WDXRF Alexander Seyfarth Bruker AXS Inc., 5465 East Cheryl Parkway, Madison, Wisconsin 53711-5373 The application of wavelength-dispersive XRF to the analysis of boron in glass is reviewed with respect to physical, instrumental, calibration, and maintenance considerations. Advances in XRF instrumentation have enabled improvement in the analysis of boron. Reduced window thickness and high-current capabilities of X-ray tubes, as well as new analyzer crystals, produce a higher intensity boron signal. With correct determination of background and matrix interferences for successful quantification, only the sample itself limits the analysis. Observed boron migration in some glasses needs to be understood in order to establish stable, routine quantification in a process environment. INTRODUCTION Boron is an important component of glass. It exerts a strong influence on the viscosity of the melt, imparting a beneficial effect to the chemical resistance and lowering the expansion coefficient of the finished article. Boron is widely used in the production of E type glasses (7 wt%), neutral glass for pharmaceutical applications (7 to 11 wt%), and Pyrex -type borosilicate glasses (13 wt%). Because of the high volatility of boron in the melting furnace, a very accurate procedure is needed to meet the strict boron concentration specifications required for the finished product and to permit any necessary batch adjustment to be implemented almost in real time. XRF is well suited for glass analyses. Since the 1980s, XRF has been the method of choice because of its ease of sample preparation and rapid results. In the production control of soda-lime glass, the technique has already replaced wet chemical techniques because of its high precision and fast measurement time. Boron, being a very light element, poses challenges to the analyst as well as to the instrument. Demand for boron analysis in the glass industry prompted the development of new generation wavelength-dispersive X-ray fluorescence (WDXRF) spectrometers. ASPECTS OF THE ANALYSIS OF BORON To put the difficulty of the analysis of boron in glass into perspective, consider its physical and chemical properties [1 3]. Physical data for boron is given in Table I. Table I. Physical data for boron. Atomic number (Z) K shell absorption edge (ev) Kα radiation (ev) Mass absorption coefficient µλ (cm 2 /g) Fluorescence yield (Ω) 5 192 183 3,350 1.25 10-4 Boron s low atomic number and low K-shell energy cause various issues for XRF analysis which will be addressed further.

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

270 EXCITATION AND FLUORESCENCE YIELD The emitted intensity, I B-Kα, of the characteristic fluorescence radiation is governed by the overlap of the excitation spectrum and the absorption coefficient µ λ of boron [4]. Absorption by the tube window cuts off the low energy (long wavelength) part of the excitation tube spectrum. Because of this, boron is excited with the primary X-ray continuum and the rhodium L lines. For optimum primary continuum, the tube window must be as thin as possible. Currently window thicknesses range from 150 to 30 µm; 75 µm has become the industry standard since it balances price, performance, and durability. Fluorescence yield is another important factor in the analysis of boron. Fluorescence yield is proportional to Z 4 and is therefore close to zero for low atomic number elements. Using the highest available tube current at the lowest possible voltage, the emission of boron photons from the sample can be optimized. Starting in 1988, the possible settings for tube current have increased from 100 ma to today s maximum of 170 ma [Siemens SRS 303 (1988) to Bruker S8 TIGER 4 kw (2006)]. Figure 1. Comparison of boron intensity in 3 kw and 4 kw WDXRF systems. As can be seen in Figure 1, 40% greater boron intensity was obtained from a boronphosphosilicate glass (BPSG) sample (4 wt% B) analyzed on a 4 kw instrument in 1999 than a 3 kw instrument in 1988 [SRS 3000 with 75 µm end window X-ray tube and 3 and 4 kw generator (1999)].

271 ANALYZED LAYER, SAMPLE PREPARATION, AND X-RAY BEAM PATH Because the energy of boron Kα radiation is so low (183 ev), only a thin 0.6 µm (600 nm) surface layer of the sample can be analyzed. The density and composition of the glass can, in some cases, reduce this down to 200 nm. The glass samples to be analyzed must therefore be prepared with a good surface finish. Mellott compiled and investigated the surface roughnesses of commercial glasses using Atomic Force Microscopy (AFM) and found that many are in the range from 2 to 0.2 nm [5]. Quantitative boron analysis on non-polished glasses was much less accurate and repeatable than on the same polished material (private communication in 2004 with Brian Simpkins, Alcan Packaging, formerly Wheaton Glass, Millville, New Jersey). Reducing the path length of the X-ray beam (tube-to-sample and sample-to-detector) and using thin-window flow proportional detectors, combined with a controlled vacuum of better than 0.1 mbar, enables higher yield of detected boron radiation. Comparing the published sensitivities from a 1998 dual-turret spectrometer with those from a direct-loading S4-type system using the same X-ray tube, the type of generator shows a substantial effect, attributable to the optimized beam path and window design [6 8]. Changes in the vacuum during the measurement affect the count rate of the detected boron and needs to be taken into consideration for those systems that have large sample compartments (e.g., dual-turret systems). In contrast, direct-loading systems can usually achieve a stable vacuum without changeover during the whole measurement period. These direct-loading systems feature pressure-controlled sample introduction. Measurement is started only when the pressure in the sample compartment reaches a certain level, resulting in constant pressure and higher, more stable count rates for boron. ANALYZER CRYSTALS Figure 2. Comparison of boron intensity collected with a traditional crystal versus multilayer crystal. Ricardo et al. showed in 2001 that with a new type of patented multilayer detector crystal, the boron signal can be raised by 28% [9]. The XS-B crystal depicted in Figure 2 is a LaB 4 C multilayer and is available from Incoatec GmbH (Gesthacht, Germany). Schuster et al. performed a feasibility study for the analysis of boron in a coating of BPSG, a common semiconductor material, in 1987 [10]. Using a WDXRF system equipped with a 125 µm endwindow X-ray tube, 80 ma tube current, and early multilayer crystal (OVO 160), he obtained a sensitivity of 2.7 counts/s per wt% B. The detection limit was reported to be 0.04 wt% for 600 s measurement time.

272 Using a 200 Å Mo-B 4 C multilayer crystal (OVO-B) and an S4 Series WDXRF system optimized for beam path, Mauser achieved a detection limit of 0.02 wt % B in 100 s and a sensitivity of 330 counts/s per wt% B on the same type of material [7]. Using the XS-B multilayer crystal on the same S4 instrument further improved the sensitivity to 420 counts/s per wt% B as was shown by Behrens in 2004 [11]. CHOICE OF COLLIMATORS AND BACKGROUND POSITIONS Multilayer crystals produce wide peak profiles and should be used with coarse collimators. The rule of thumb in WDXRF is to use the coarsest collimator for the lightest element detection. Since achieving a high count rate is paramount for the analysis, peak resolution and interference corrections are not an issue. This holds true for BPSG, but in order to create a meaningful widerrange calibration for commercial borosilicate and E glass as well, count rate needs to be balanced against resolution [12]. K Ll, Ca Ll Cl Ll, B KA1 O (3) Zr Mz Si LB/ S Ll Ln Ca Ca and K L l lines, as well as Ca Ln and Zr M lines, should be separated as shown in Figure 3. The effect of higher order reflections of O cannot be reduced much by using pulse height discrimination and needs to be minimized by collimation. With Ca and Zr present in the analyzed material, the selection of background positions becomes difficult. The approach from Feather and Willis is particularly useful in this regard, as it can be used to perform interference correction on the background [13]. CALIBRATION APPROACH <21.778 Y : 0 to 2.260 KCps 61.978> Figure 3. Interference on and around the boron K signal. Obtaining a sufficient number of glass standards, as well as including enough samples to perform the interference corrections needed, pose the biggest challenge to the analyst. The quality of the boron certification by Manitol-based volumetric means is very much dependent on the experience of the analyst with that methodology. Few commercial labs now offer Manitol-based boron analysis. Inductively coupled plasma (ICP) methods are increasingly being offered instead, but these methods are time- and cost-prohibitive because of the requirement for sample digestion. Few glass samples of defined boron composition are commercially available. Many borosilicate glass samples, such as those available from Breitlaender GmbH (Hamm, Germany), are just premelt batch and not chemically certified. Borosilicate glass suppliers are the best source of sample material. They can produce a range of experimental matrix for the calibration based on past batch-melt samples. A comparison and discussion of the quality of certification techniques for boron in glass is unfortunately absent from the literature.

273 Using over 40 glass samples of standard 32 mm size and a small 28 mm aperture, a calibration for boron was established from 0.00 to 19.35 wt%. The calibration has a standard error of calibration (SEC) of 0.266 wt%. The sensitivity is 94 counts/s per wt% B 2 O 3. An empirical calculation using a concentration-based correction approach produced better results than any fundamental parameters (FP) model, even with variable influence coefficients. FP for boron, as taken from the NIST-compiled tables, are not well characterized and would need further improvements. Of greatest importance is interference correction of both the background and peak position to obtain a good net intensity for boron. MAINTENANCE OF CALIBRATION In order to maintain the calibration, drift correction is needed to account for changes in detector gas, foil, and tube signal that can influence the intensity and therefore the analysis. A very interesting study by Guadagnino, Sundberg, Michiels, and Brochot showed that some glass types exhibit a migration of boron when measured repeatedly [14]. Figure 4 shows the change in B 2 O 3 content in Pyrex-type and E-type glass as a function of the number of WDXRF measurements. Borosilicate glass should therefore be used as a drift correction and QC sample only after it has been conditioned. Figure 4. Long-term stability of boron in E-type and Pyrex-type glass

274 CONCLUSION The analysis of boron in glass using WDXRF has dramatically improved since its first application as a process control tool in the late 1980s. Nevertheless, it is still one of the most challenging applications, since the analyst must gather enough reference material and optimize conditions to fit the spectrometer capabilities. The choice of the right collimator, background and peak counting positions, correct pulse height analysis settings, and interference correction method greatly influences the range and durability of the resulting calibration. Maintenance of the calibration and a daily check of the system and calibration need to take the stability of the glass standards into account. ACKNOWLEDGMENTS The author thanks Brian Simpkins (Alcan Packaging, formerly Wheaton Glass, Millville, New Jersey) for his time performing the scans and tests on the borosilicate glass samples, as well as for evaluating the XS-B and OVO-B crystals side-by-side in a process environment. Many thanks as well to my colleagues at Bruker AXS Larry Arias, Kai Behrens, Karl Mauser, and Karen Roscoe for contributing to the presentation and article. REFERENCES [1] Bearden, J. A. Rev. Mod. Phys. 1967, 39, 78 124. [2] Krause, M. O. J. Phys. Chem. Ref. Data 1979, 8, 307 327. [3] White, E. W.; Johnson Jr., G. G. X-ray Emission and Absorption Wavelengths and Two- Theta Tables (ASTM Data Series DS 37A); American Society for Testing and Materials: Philadelphia, 1970. [4] Shiraiwa, T.; Fujino, N. Jpn. J. Appl. Phys. 1966, 5, 886 899. [5] Mellott, N. P.; Brantley, S. L.; Hamilton, J. P.; Pantano, C. G. Surf. Interface Anal. 2001, 31, 362 368. [6] Mauser, K. E.; Uhlig, S. SRS 3400 Boron in BPSG. Bruker AXS GmbH Application Note, 1999. [7] Mauser, K. E. S4 PIONEER Boron in BPSG. Bruker AXS GmbH Application Note, 2002. [8] Buehler, A.; Seyfarth, A.; Schlotz, R. Introduction to XRF. Bruker AXS GmbH Training Manual, 2000. [9] Ricardo, P.; Wiesmann, J.; Nowak, C.; Michaelsen, C.; Bormann, R. Appl. Opt. 2001, 40, 2747 2754. [10] Schuster, M.; Müller, L.; Mauser, K. E.; Straub, R. Thin Solid Films 1988, 157, 325 336. [11] Behrens, K. New Applications with the XS-B; S4 PIONEER. Bruker AXS GmbH Application Note, 2004. [12] Uhlig, S.; Müller, L. Boron Analysis in Ceramic and Glass Industries using Wavelength Dispersive X-ray Fluorescence Analysis. Siemens Analytical Application Notes 326, 1991. [13] Feather, C. E.; Willis, J. P. X-Ray Spectrom. 1976, 5, 41 48. [14] Guadagnino, E.; Sundberg, P.; Michiels, D.; Brochot, D. A collaborative study into the determination of boron in glass using X-ray fluorescence (XRF) spectroscopy. ICG/TC2 report, 2006.