Mass Selective Ejection by Axial Resonant Excitation from a Linear Ion Trap

Similar documents
Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

Introduction to the Q Trap LC/MS/MS System

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Ion traps. Quadrupole (3D) traps. Linear traps

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

Design considerations for linear Paul trap mass spectrometer under development

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Mass Spectrometry and Proteomics - Lecture 2 - Matthias Trost Newcastle University

Ion trap. 3D Quadrupole Trap. -Mass spectrometer -Ion trap (Quadrupol Ion Storage, Quistor) 18. April

Types of Analyzers: Quadrupole: mass filter -part1

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Thermo Finnigan LTQ. Specifications

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

CEE 772: Instrumental Methods in Environmental Analysis

Powerful Scan Modes of QTRAP System Technology

Analysis of Polar Metabolites using Mass Spectrometry

RESEARCH ARTICLE. Characteristics of Ion Activation and Collision Induced Dissociation Using Digital Ion Trap Technology

Mass Analyzers. Ion Trap, FTICR, Orbitrap. CU- Boulder CHEM 5181: Mass Spectrometry & Chromatography. Prof. Jose-Luis Jimenez

Mass Spectrometry in MCAL

Space Charge Effects in Linear. Quadrupole Ion Traps

TANDEM MASS SPECTROSCOPY

Three dimensional Paul traps may benefit from. Linear Quadrupoles with Added Hexapole Fields

First described by W. Paul and H. Steinwedel in

Tendenze nell innovazione della strumentazione in spettrometria di massa:

Chemistry 311: Topic 3 - Mass Spectrometry

Lecture 8: Mass Spectrometry

Harris: Quantitative Chemical Analysis, Eight Edition

LECTURE-11. Hybrid MS Configurations HANDOUT. As discussed in our previous lecture, mass spectrometry is by far the most versatile

Lecture 8: Mass Spectrometry

Accurate, High-Throughput Protein Identification Using the Q TRAP LC/MS/MS System and Pro ID Software

Chemistry Instrumental Analysis Lecture 35. Chem 4631

Practical Quadrupole Theory: Peak Shapes at Various Ion Energies

MS Goals and Applications. MS Goals and Applications

Electrospray ionization mass spectrometry (ESI-

Technical Note # TN-24 Extending the Capacity in Modern Spherical High Capacity Ion Traps (HCT)

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR-MS)

All of us engaged in science face exciting opportunities

Performance Evaluation of a Hybrid Linear Ion Trap/Orbitrap Mass Spectrometer

Extrel Application Note

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. MAGLAB Summer School Ryan P. Rodgers

Ion Sponge: A 3 Dimentional Array of Quadrupole Ion Traps for Trapping and Mass-Selectively Processing Ions in Gas Phase

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

GRADUATE COURSE IN MASS SPECTROMETRY: LECTURE 2

The Planar Electrode Linear Ion Trap

FOCUS: VAN BERKEL, 2005 BIEMANN MEDAL AWARDEE Determination of Cooling Rates in a Quadrupole Ion Trap

The Aerosol Ion Trap Mass Spectrometer (AIMS): Instrument development and first experimental results

MS/MS .LQGVRI0606([SHULPHQWV

Finnigan LCQ Advantage MAX

Asymmetrical features of mass spectral peaks produced by quadrupole mass filters

The development of algebraic methods to compute

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Mass Spectrometry. Fundamental LC-MS. Mass Analysers

Simulation of External Ion Injection, Cooling and Extraction Processes with SIMION 6.0 for the Ion Trap/Reflectron Time-of-flight Mass Spectrometer

Mass Spectrometry. What is Mass Spectrometry?

Ions trapped within a linear quadrupole ion trap can

1. The range of frequencies that a measurement is sensitive to is called the frequency

MS Goals and Applications. MS Goals and Applications

FOCUS: QUADRUPOLE ION TRAPS ACCOUNT AND PERSPECTIVE

Mass spectrometry.

Translational Biomarker Core

A Simple Multi-Turn Time of Flight Mass Spectrometer MULTUM II

LC-MS Based Metabolomics

Identification of Human Hemoglobin Protein Variants Using Electrospray Ionization-Electron Transfer Dissociation Mass Spectrometry

WADA Technical Document TD2003IDCR

Electrospray ionization (ESI) has enabled the study

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

When a pulse of ions is injected into a buffer

Instrumentation development for coupling ion/ion reactions and ion mobility in biological mass spectrometry

The genealogical relationships between ions in a

Secondary Ion Mass Spectroscopy (SIMS)

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

B American Society for Mass Spectrometry, 2016 J. Am. Soc. Mass Spectrom. (2016) 27:1914Y1921 DOI: /s y RESEARCH ARTICLE

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

Ever since the mass spectrometer was introduced,

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS

The fundamental equations of motion for the ions

SHORT COMMUNICATION. Electron Capture, Collision-Induced, and Electron Capture-Collision Induced Dissociation in Q-TOF

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

NOVEL INSTRUMENTATION AND METHOD DEVELOPMENT FOR A QUADRUPOLE ION TRAP MASS SPECTROMETER. G. Asher Newsome

Technical Note. Introduction

Planar Electrode Quadrupole Ion Traps

Ion Cyclotron Resonance Program, National High Magnetic Field Laboratory, Florida State University, Tallahassee, Florida, USA

Mass spectrometric determination of the surface compositions of ethanol water mixtures

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

a. An emission line as close as possible to the analyte resonance line

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Most commercial quadrupole mass spectrometers

Interazioni di ioni con elettroni (ECD, ETD) e fotoni (Ion spectroscopy) Gianluca Giorgi. via Aldo Moro Siena

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS)

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

This is the total charge on an ion divided by the elementary charge (e).

Introduction to GC/MS

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Recent trends in mass spectrometer development

Transcription:

Mass Selective Ejection by Axial Resonant Excitation from a Linear Ion Trap Yuichiro Hashimoto, Hideki Hasegawa, Takashi Baba, and Izumi Waki Central Research Laboratory, Hitachi, Ld., Tokyo, Japan We describe a new mass selective ejection method from a linear ion trap, which we call axial resonant excitation (AREX). A set of vane lenses are inserted between each quadrupole rod to produce electrostatic potential that is approximately harmonic along the central axis of the quadrupole field. After ions with specific m/z are resonantly oscillated in the axial direction, the ions are mass selectively ejected in the axial direction. At a high scan rate of 11 Th/ms, AREX achieved a high ejection efficiency of more than 60%, which is more than three times higher than a conventional mass selective axial ejection method from a linear trap using fringing field. (J Am Soc Mass Spectrom 2006, 17, 685 690) 2006 American Society for Mass Spectrometry Published online March 9, 2006 Address reprint requests to Dr. Y. Hashimoto, Central Research Laboratory, Hitachi, Ltd., 1-280 Higashi-koigakubo, Kokubunji-shi, Tokyo 185-8601, Japan. E-mail: h-yuichi@crl.hitachi.co.jp MS n (n 3) analysis by a quadrupole ion trap is a powerful tool for analyzing proteins [1], peptides [2], carbohydrates [3], metabolites, and other compounds [4]. The quadrupole ion trap can be classified into two types, the 3D-quadrupole ion trap (QIT) or the 2D-quadrupole ion trap (or linear ion trap, LIT). The LITs are widely used as a mass selective ejection device in a low-resolution mass spectrometer [5, 6] or a fragmentation and precursor selection device in a higher-resolution hybrid mass spectrometer [7 9], because the LIT has 10 times higher trapping efficiency and two times broader trapping mass window than the QIT [5, 9]. For a mass selective ejection device, the ejection efficiency and scan rate is very important because these determine the sensitivity and throughput of the mass spectral acquisition. A scan rate of 1 10 Th/ms is used for commercial instruments, so as not to degrade the sensitivity and the throughput [5, 6]. Schwartz et al. reported mass selective ejection in a radial direction with an ejection efficiency of 44% at a scan rate of 5.5 Th/ms [5]. After ions are oscillated by a supplemental AC field applied between a pair of opposite quadrupole rods, they are ejected through the exit slits of the rods into dual detectors. Hager reported mass selective ejection in an axial direction with the ejection efficiency of less than 20% at a scan rate of 1.0 Th/ms [6]. Though ions were radially oscillated in a similar manner as that of Schwartz, the fringing field near the end lens ejects the radially oscillated ions into the axial direction. Collisions of the ions with the rods decreased the ejection efficiency to less than 20%. In a similar axial ejection, a better axial-ejection efficiency of over 90% was achieved by a high-order field perturbation with a low scan rate of 0.02 Th/ms [10]. This scan rate is too slow for practical use, because it degrades the duty cycle of the LIT to less than 1%. We report in this paper a new mass selective axial ejection with high ejection efficiency of 60% at 11 Th/ms by axial resonant excitation (AREX) in an LIT. A set of lenses that are inserted between each quadrupole rod makes a DC potential that is approximately harmonic along the central z-axis of the linear trap. Inside the quasi-harmonic potential, ions with a specific m/z range can be resonantly oscillated in the axial direction by superimposing a supplemental AC field, so that the ions are mass-selectively ejected in the axial direction. High ejection efficiency is possible, because the oscillated and ejected directions are the same. Experimental Instrumentation The experimental setup was modified from the linear trap mass spectrometer described previously [9] and is depicted in Figure 1. Samples are prepared as 100 nm solutions in a methanol solution, and are ionized in a positive mode using a gas-assisted electrospray ion source (ESI), at a flow rate of 5 l/min. Ions are introduced from the ESI through a multipole ion guide into a pre-trap. The pre-trap can isolate ions with a specific m/z as described [9]. Helium is introduced into the pre-trap as a bath gas of 2 mtorr. After trapping ions for about 50 ms, the ions are ejected out of the pre-trap into an AREX LIT. The AREX LIT has an incap lens, an endcap lens, four quadrupole rods, and eight lenses that are inserted between the rods (vane lenses). The rod length of the AREX LIT is 44 mm, the rod radius (R) is 9.17 mm, and the distance between the rod and the center axis (r) is 8.00 mm. Two phases of the trapping RF voltage ( 600 V (0-peak), 770 khz) were 2006 American Society for Mass Spectrometry. Published by Elsevier Inc. Received January 4, 2006 1044-0305/06/$32.00 Revised January 25, 2006 doi:10.1016/j.jasms.2006.01.011 Accepted January 26, 2006

686 HASHIMOTO ET AL. J Am Soc Mass Spectrom 2006, 17, 685 690 Figure 1. Schematic drawing of AREX LIT; c 0 : 11.6 mm, c 1 : 0.8 mm, L:22mm,g: 1.0 mm, and p: fitting parameter (1.0 3.0). applied to the rod pairs. Vane lenses consist of a set of four front vanes and another set of four rear vanes, with a thickness of 0.5 mm. The four lenses comprising each set are at a same electric potential. The vane potential (D 0 ), which is a DC potential of the vane lenses relative to a quadrupole-rods DC offset, makes a potential that is approximately harmonic along the central axis of the quadrupole field. The shape of the vane lenses and the potential formed thereby are described in the next section. A supplemental AC voltage ( 20.0 V (0- peak), 5 100 khz) was applied between the front and rear vanes to oscillate ions resonantly in an axial direction. The oscillated ions were ejected and detected in an axial direction. The measurement sequence of the AREX LIT is shown in Figure 2. The measurement sequence consists of accumulation, cooling, scan, and emptying periods. During an accumulation period, the ions from the pre-trap are accumulated inside the AREX LIT, where the incap and the endcap lenses make an axial trapping field, and quadrupole rods make a radial trapping field inside the trap. Helium was introduced into the AREX LIT as a 2 mtorr bath gas, where the base pressure of the chamber was about 2 10 5 torr. Typical trapping efficiency was over 90%, which is consistent with the other LIT [9]. During a cooling period, the vane potential (D 0 ) rises to 10 150 V, so that ions are focused near a central point O. During a scan period, a supplemental AC frequency is swept from a higher to a lower frequency at a constant scan rate. Oscillated ions were mass-selectively ejected and detected by an electron multiplier (Burle Industries Inc., Lancaster, PA). During an emptying period, all the remaining ions in the AREX are ejected by lowering endcap DC potential. Geometry of Vane Lenses to Approximate Axial Harmonic Potential To create approximately a harmonic potential along the z-axis, we used eq 1 as a model of vane lens shape. The distance, d, between the edge of the vane lens and the central axis is d c 0 (c 1 c 0 ) z p, (1) L where c 0, c 1, and L describe physical dimensions of the vane lenses as in Figure 1b. We calculated a best-fit potential whose difference from the harmonic is minimized within the z-range of 0.8 L. The fitting equation is D(z) D 0 A 0 A 2 L z 2, (2) where A 0 and A 2 are free fitting parameters. Within this fitting range, the vane potential sufficiently approximates a harmonic potential, though it deviates from the harmonic near the edge of the rod. Figure 3 shows the correlation coefficient between the harmonic potential and the vane potential within 0.8 L for various p values. When p is from 1.5 to 2.2, the correlation coefficient is above 0.998, so that the potential approximates a harmonic potential sufficiently. Therefore, we chose a vane lens with p 2.0 in all later experiments.

J Am Soc Mass Spectrom 2006, 17, 685 690 MASS EJECTION BY AREX FROM A LINEAR ION TRAP 687 Figure 2. Measurement sequence of AREX LIT. Results and Discussion Mass Resolution of AREX From eq 2, axial ion motion is given by m d2 z dt 2 e z D(z) 2eA 2D 0 z L 2, (3) where m is a mass of ions. The resonant frequency in the axial direction, f, is obtained from eq 3. single scan and the bold line is an averaged spectrum of 128 scans. Substituting the bestfit A 2 into eq 4, we obtained a calculated resonant frequency of 42.33 khz, which meets well with the observed f 0 range between 42.1 and 42.8 khz (Figure 4). Frequency was swept from higher to lower at various sweep rates between 50 and 1600 Hz/ms, which corresponds to mass scan rates of 1.4 Th/ms and 46.3 Th/ms at 609.3 Th. Several subpeaks are observed in each single-scan spectrum. The f 2 1 2eA 2D 0. (4) ml 2 Eq 4 can be differentiated to give m dm 1 f 2 df. (5) Therefore, the mass resolution by a frequency sweep was defined by f 0 2 f, where f 0 is a center frequency of the peak and f is a full width at half maximum. Figure 4 shows a frequency sweep spectrum of reserpine peak at 609.3 Th. The fine line is the spectrum obtained by a Figure 3. Correlation coefficient versus P value.

688 HASHIMOTO ET AL. J Am Soc Mass Spectrom 2006, 17, 685 690 Figure 4. Frequency spectra for reserpine ion; bold line: average spectra of 128 scans, thin line: single scan spectra, m/z 609.3, D 0 130 V, supplemental AC amplitude was 12 V. time interval between sub-peaks is 23 to 24 s, which corresponds to a resonance cycle of an axial harmonic potential. These sub-peaks appear because ions are ejected in a specific phase range of the supplemental AC field independently of main RF phase. In conventional LIT, the excited ions are also ejected synchronously with the supplemental AC. The sub-peaks are not observed, however, because signal detection response is too slow to resolve the sub-peaks, where the supplemental AC frequency is above several hundreds khz. On the other hand, the supplemental AC frequency of AREX was less than 50 khz. All the spectra by a single scan have a similar envelope shape with full width at half maximum containing 5 sub-peaks. The number of sub-peaks was similar in case of different scan rate and different vane potential D 0. Therefore, we suppose this envelope distribution derives from the thermal distribution of initial trapping state. The constant number of sub-peaks in a single scan envelope results in the frequency-width being inversely proportional to the scan rate, as can be seen in Figure 4a f. Mass resolution that is calculated from the envelope width was 1800 at a scan rate of 50 Hz/ms (Figure 4a). The resonance frequency of each single scan fluctuated by about 15 Hz because of the instability of the DC power supplies of about 100 mv, which is about 0.1% of the vane potential of 130 V. Therefore, the mass resolution of the averaged spectrum in Figure 4a degraded to 900. Mass resolution calculated from the averaged peak was plotted in Figure 5. Though a lower mass scan rate achieves a higher mass resolution, the mass resolution Figure 5. Mass resolution versus scan rate; m/z 609.3, supplemental AC amplitudes were 12, 6, 1.25 V for D 0 130, 40, 10 V, respectively.

J Am Soc Mass Spectrom 2006, 17, 685 690 MASS EJECTION BY AREX FROM A LINEAR ION TRAP 689 saturates below 1000 because of the instability of the electric supply as described. Above a scan rate of 6 Th/ms with D 0 130 V, the mass resolution degrades inverse-proportionally to the scan rate, which is consistent with the fact that about five cycles (5/f) of harmonic oscillation corresponds to the averaged peak width as shown in Figure 4c f. That is, Mass _ Scan _ Rate dm dt m 5 f. (6) Mass _ Resolution m m m f 5 Mass _ Scan _ Rate. (7) In Figure 5, mass resolution is proportional to the root of D 0 at higher scan rates, which is consistent with the fact that about five cycles (5/f) of harmonic oscillation corresponds to the averaged peak width in different D 0 case. That is, mass resolution can be converted by eqs 4 and 7 to give Mass _ Resolution f D 0. (8) Ejection Efficiency of AREX Ejection efficiency was evaluated as follows. First, a pre-trap isolated reserpine ion of 609 Th from others so that all ions ejected from the AREX LIT are considered as reserpine ions. The initial amount of reserpine ions trapped in the AREX LIT was measured by axially ejecting all the trapped ions by lowering the endcap DC potential after ion accumulation. After resonantly ejecting the trapped ions, the remaining ions were measured by lowering the endcap DC of end lens. Figure 6 shows resonant ejection ions and remaining ions that are normalized by the initial amount of reserpine ions. High ejection efficiencies of more than 60% were obtained in a V AC range of 12 18 V. Each mass resolution Figure 7. Mass Spectrum obtained by frequency sweep; scan speed: 0.3 khz/ms (57 42 khz); 8.6 Th/ms at m/z 609.3, scan period: 50 ms D 0 : 130 V, V AC :15V. ranged from 350 to 450 FWHM (typically Figure 4d). This high ejection efficiency is possible because the oscillated and ejected directions are the same, whereas the oscillated and ejected directions are perpendicular in the conventional axial ejection [6]. More than 50% of the ions are ejected into a detector direction, not into the pre-trap direction, because the incap lens potential (130 V) was higher than the endcap. When a same DC potential of 0 V was applied to the incap and endcap lens, ejection efficiency decreased to 30%. The loss of ions is mainly estimated by the collisions with the endcap lens, which is also supported by simulation results. Figure 7 shows the mass spectrum that was converted from a frequency spectrum. In addition to the reserpine peak of 609 Th, fragment peaks of 397, 415, 436, and 448 Th are observed, which were produced at the skimmer. The mass resolution of each peak ranged from 350 to 500. As described above, AREX LIT achieved high trapping efficiency and high ejection efficiency, which are beneficial to practical use. On the other hand, AREX LIT might be affected by space charge more strongly than the other LITs because AREX LIT excites ions at a center point and the other LITs excite ions along the entire length of the quadrupole rods, which we will plan to evaluate in the future. Conclusions Figure 6. Ion ejection efficiency versus supplemental AC amplitude V AC ; scan speed: 0.4 khz/ms; 11.4 Th/ms, D 0 : 130 V. In summary, we demonstrated, for the first time, a mass selective ejection method from a linear ion trap, the axial resonant excitation (AREX). AREX achieved a high ejection efficiency of more than 60% at a mass resolution of 400 and a scan rate of 11 Th/ms. We expect that the mass resolution of AREX can be improved further by optimizing the vane shape. This high efficiency of mass selective axial ejection at practical scan rate should also be beneficial for hybrid mass spectrometers.

690 HASHIMOTO ET AL. J Am Soc Mass Spectrom 2006, 17, 685 690 Acknowledgments The authors acknowledge the many suggestions received concerning ion simulation by Dr. K. Yoshinari of Hitachi, Ltd., Hitachi Research Laboratory and Mr. H. Toyama and Mr. T. Iwata of the authors laboratory for the electrical supply system provided for this instrument. References 1. Coon, J. J.; Ueberheide, B.; Syka, J. E. P.; Dryhurst, D. D.; Ausio, J.; Shabanowitz, J.; Hunt, D. F. Protein identification using sequential ion/ion reactions and tandem mass spectrometry. Proc. Natl. Acad. Sci. U.S.A. 2005, 102, 9463 9468. 2. Kokubu, M.; Ishihama, Y.; Sato, T.; Nagasu, T.; Oda, Y. Specificity of immobilized metal affinity-based IMAC/C18 tip enrichment of phosphopeptides for protein phosphorylation analysis. Anal. Chem. 2005, 77(16), 5144 5154. 3. Ashline, D.; Singh, A.; Hanneman, A.; Reinhold, V. Congruent strategies for carbohydrate sequencing. 1. Mining structural details by MS n. Anal. Chem. 2005, 77(19), 6250 6262. 4. Hopfgartner, G.; Husser, C.; Zell, M. Rapid Screening and characterization of drag metabolites using a new quadrupole-linear ion trap mass spectrometer. J. Mass Spectrom. 2003, 38(2), 138 150. 5. Schwartz, J. C.; Senko, M. W.; Syka, J. E. P. A two-dimensional quadrupole ion trap mass spectrometer. J. Am. Soc. Mass Spectrom. 2002, 13, 659 669. 6. Hager, J. W. A new linear ion trap mass spectrometer. Rapid Commun. Mass Spectrom. 2002, 16, 512 526. 7. Syka, J. E. P.; Marto, J. A.; Bai, D. L.; Horning, S.; Senko, M. W.; Schwartz, J. C.; Ueberheide, B.; Garcia, B.; Busby, S.; Muratore, T.; Shabanowitz, J.; Hunt, D. F. J. Proteome. Res. 2004, 3, 621 626. 8. Makarov, A.; Denisov, E., Lange, O.; Kholomeev, A.; Horning, S. Dynamic range of mass accuracy in FTMS. Proceedings of the 53rd ASMS Conference on Mass Spectrometry and Allied Topics; San Antonio, TX, June, 2005. 9. Hashimoto, Y.; Hasegawa, H.; Waki, I. Dual linear ion trap/orthogonal acceleration time-of-flight mass spectrometer with improved precursor ion selectivity. Rapid Commun. Mass Spectrom. 2005, 19, 1485 1491. 10. Moradian, A.; Douglas, D. J. Axial ion ejection from linear quadrupoles with added octopole fields. Proceedings of the 53rd ASMS Conference on Mass Spectrometry and Allied Topics; San Antonio, TX, June, 2005.