Performance Characterization of Two Selected Refrigerants in a Flat-Plate Micro-Tube Condenser

Similar documents
FORCE FED BOILING AND CONDENSATION FOR HIGH HEAT FLUX APPLICATIONS

An experimental investigation on condensation of R134a refrigerant in microchannel heat exchanger

InterPACKICNMM

Experimental Analysis of Wire Sandwiched Micro Heat Pipes

AN EXPERIMENTAL INVESTIGATION OF BOILING HEAT CONVECTION WITH RADIAL FLOW IN A FRACTURE

R32 Heat Transfer Coefficient During Condensation In A Mini-Channel Multiport Tube

Experimental investigation on up-flow boiling of R1234yf in aluminum multi-port extruded tubes

Heat transfer coefficient of near boiling single phase flow with propane in horizontal circular micro channel

Evaporation Heat Transfer Coefficients Of R-446A And R-1234ze(E)

Piping Systems and Flow Analysis (Chapter 3)

DETERMINATION OF R134A S CONVECTIVE HEAT TRANSFER COEFFICIENT IN HORIZONTAL EVAPORATORS HAVING SMOOTH AND CORRUGATED TUBES

a. Key Laboratory of Efficient Utilization of Low and Medium Grade Energy, MOE, Tianjin University, Tianjin , China

EXPERIMENTAL ANALYSIS OF R-134a FLOW CONDENSATION IN A SMOOTH TUBE

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Condensation and Evaporation Characteristics of Flows Inside Three Dimensional Vipertex Enhanced Heat Transfer Tubes

EFFECT OF LIQUID REYNOLDS NUMBER ON PRESSURE DROP OF EVAPORATIVE R-290 IN 500µm CIRCULAR TUBE

Minhhung Doan, Thanhtrung Dang

SEM-2017(03HI MECHANICAL ENGINEERING. Paper II. Please read each of the following instructions carefully before attempting questions.

Boiling Heat Transfer and Pressure Drop of R1234ze(E) inside a Small-Diameter 2.5 mm Microfin Tube

Two-Phase Refrigerant Distribution in a Micro- Channel Manifold

Enhanced MicroChannel Heat Transfer in Macro- Geometry using Conventional Fabrication Approach

IHTC DRAFT MEASUREMENT OF LIQUID FILM THICKNESS IN MICRO TUBE ANNULAR FLOW

ME 402 GRADUATE PROJECT REPORT ACTIVE BATTERY COOLING SYSTEM FOR ALL-ELECTRIC VEHICLES JINGWEI ZHU

Characteristics of Flow Boiling Heat Transfer of Sub-Critical CO2 in Mini-Channels With Micro- Fins

Condensation of refrigerant R407C in multiport minichannel section

Mathematical Modelling for Refrigerant Flow in Diabatic Capillary Tube

If there is convective heat transfer from outer surface to fluid maintained at T W.

Effect of flow velocity on the process of air-steam condensation in a vertical tube condenser

Using Computational Fluid Dynamics And Analysis Of Microchannel Heat Sink

THE CHARACTERISTICS OF BRAZED PLATE HEAT EXCHANGERS WITH DIFFERENT CHEVRON ANGLES

Forced Convective Boiling Heat Transfer in Microtubes at Low Mass and Heat Fluxes

Axial profiles of heat transfer coefficients in a liquid film evaporator

THE EXPERIMENTAL STUDY OF THE EFFECT OF ADDING HIGH-MOLECULAR POLYMERS ON HEAT TRANSFER CHARACTERISTICS OF NANOFLUIDS

Heat transfer and pressure drop experimentation inside single minichannels

Pressure drop during condensation of refrigerants in pipe minichannels

Heat Transfer of Condensation in Smooth Round Tube from Superheated Vapor

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins

Chapter 10: Boiling and Condensation 1. Based on lecture by Yoav Peles, Mech. Aero. Nuc. Eng., RPI.

Boiling and Condensation (ME742)

Uncertainty Analysis on Prediction of Heat Transfer Coefficient and Pressure Drop in Heat Exchangers Due to Refrigerant Property Prediction Error

INVESTIGATION OF VAPOR GENERATION INTO CAPILLARY STRUCTURES OF MINIATURE LOOP HEAT PIPES

Comparison of Heat Transfer rate of closed loop micro pulsating heat pipes having different number of turns

Thermo-Fluid Performance of a Vapor- Chamber Finned Heat Sink

EXPERIMENTAL STUDY OF R-134A VAPORIZATION IN MINICHANNELS

EXPERIMENTAL INVESTIGATION OF THE HEAT TRANSFER IN A HORIZONTAL MINI-TUBE WITH THREE DIFFERENT INLET CONFIGURATIONS

EVAPORATIVE CO 2 HEAT TRANSFER MEASUREMENTS FOR COOLING SYSTEMS OF PARTICLE PHYSICS DETECTORS

ANALYSIS OF NANOFLUIDS IN LIQUID ELECTRONIC COOLING SYSTEMS

Heat Transfer Measurements for a Horizontal Micro-Tube Using Liquid Crystal Thermography

Analysis of the Cooling Design in Electrical Transformer

Level 7 Post Graduate Diploma in Engineering Heat and mass transfer

TWO-PHASE FLOW BOILING IN MICROCHANNELS FOR COOLING OF MICROELECTRONICS

Enhanced Boiling Heat Transfer by using micropin-finned surfaces for Electronic Cooling

first law of ThermodyNamics

Principles of Food and Bioprocess Engineering (FS 231) Problems on Heat Transfer

FLOW BOILING HEAT-TRANSFER IN PLATE MICRO- CHANNEL HEAT SINK

Coolant. Circuits Chip

Australian Journal of Basic and Applied Sciences. Numerical Investigation of Flow Boiling in Double-Layer Microchannel Heat Sink

BOILING IN A VERTICAL FRACTURE

Capillary Blocking in Forced Convective Condensation in Horizontal Miniature Channels

Fundamental issues, mechanisms and models of flow boiling heat transfer in microscale channels

Experimental Study of Energy Efficiency of a Single Microtube

FE Fluids Review March 23, 2012 Steve Burian (Civil & Environmental Engineering)

Heat Transfer Predictions for Carbon Dioxide in Boiling Through Fundamental Modelling Implementing a Combination of Nusselt Number Correlations

Heat Transfer Characteristics for Condensation of R134a in a Vertical Smooth Tube

TWO-PHASE FLOW FRICTIONAL PRESSURE DROP OF FC-14 IN HORIZONTAL TUBES

Analysis Of Void Fraction In Microchannels

Single-Phase Modeling in Microchannel with Piranha Pin Fin

Fluid Flow, Heat Transfer and Boiling in Micro-Channels

Oil Retention and Pressure Drop of R134a, R1234yf and R410A with POE 100 in Suction Lines

THE EFFECT OF LIQUID FILM EVAPORATION ON FLOW BOILING HEAT TRANSFER IN A MICRO TUBE

8800 Greenbelt Rd Greenbelt, MD 20771, USA

EXPERIMENTAL INVESTIGATION OF THE EFFECT OF MULTIPLE SYNTHETIC JETS ON HEAT TRANSFER AND PRESSURE LOSS IN MINICHANNELS

heat transfer process where a liquid undergoes a phase change into a vapor (gas)

S.E. (Chemical) (Second Semester) EXAMINATION, 2011 HEAT TRANSFER (2008 PATTERN) Time : Three Hours Maximum Marks : 100

AIR-CONDITIONING, HEATING AND REFRIGERATION TECHNOLOGY INSTITUTE, INC 2111 Wilson Boulevard, Suite 500, Arlington, Virginia

An Experimental Study On Condensation Of R134a In A Multi-Port Extruded Tube

(Refer Slide Time: 00:00:59 min)

Effect of Nanofluid Concentration on the Performance of Circular Heat Pipe

EXPERIMENTAL INVESTIGATION OF CONVECTIVE BOILING IN MINI-CHANNELS: COOLING APPLICATION OF THE PROTON EXCHANGE MEMBRANE FUEL CELLS

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

Two Phase Pressure Drop of CO2, Ammonia, and R245fa in Multiport Aluminum Microchannel Tubes

Chapter 3 PROPERTIES OF PURE SUBSTANCES. Thermodynamics: An Engineering Approach, 6 th Edition Yunus A. Cengel, Michael A. Boles McGraw-Hill, 2008

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Superfluid helium heat pipe. P.

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Conjugate heat transfer from an electronic module package cooled by air in a rectangular duct

Boiling of R-134a in Horizontal Mini Tube

Free and Forced Convection Heat Transfer Characteristics in an Opened Box with Parallel Heated Plates

Integration of Boiling Experiments in the Undergraduate Heat Transfer Laboratory

Experimental Thermal and Fluid Science

KEYNOTE PAPER LIQUID FILM THICKNESS IN MICRO CHANNEL SLUG FLOW

LIQUID FILM THICKNESS OF OSCILLATING FLOW IN A MICRO TUBE

Measurement of the performances of a transparent closed loop two-phase thermosyphon

Heat transfer from in-line tube bundles to downward aqueous foam flow

ME 331 Homework Assignment #6

CONVECTION HEAT TRANSFER

An experimental investigation of the thermal performance of an asymmetrical at plate heat pipe

True/False. Circle the correct answer. (1pt each, 7pts total) 3. Radiation doesn t occur in materials that are transparent such as gases.

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

Stratified Flow Condensation of CO 2 in a Tube at Low Temperatures Pei-hua Li 1, a, Joe Deans 2,b and Stuart Norris 3,c

Transcription:

The Second International Energy 23 Conference Performance Characterization of Two Selected Refrigerants in a Flat-Plate Micro-Tube Condenser E. Al-Hajri 1, S. Dessiatoun 1, A. Shooshtari 1, and M. Ohadi 2 1 University of Maryland, College Park, MD 2742, U.S.A. 2 The Petroleum Institute, Abu Dhabi, U.A.E. Abstract This work presents a detailed characterization study of two-phase condensing flows of two refrigerants, R134a and R-245fa, in a single water-cooled micro-channel with a.4 mm x 2.8 mm cross-section (.7 mm hydraulic diameter and 7:1 aspect ratio) and length of 19 mm. A single micro-channel was chosen for the study to eliminate flow mal-distribution issues commonly encountered in micro-channel banks. The experiments included a parametric study of the effects on average heat transfer coefficient and overall pressure drop of variations across the micro-channel condenser with mass fluxes between 5 and 5 kg/m 2 s, saturation temperatures between 3ºC and 7ºC, and inlet super heats between ºC and 2ºC. The inlet state was kept either at 1% quality or superheat and the outlet condition at % quality; these calculations were based on water-side heat rejection. Careful design and instrumentation of the test setup resulted in energy balance uncertainty within +/-11% and uncertainty of average heat transfer coefficient within +/-12%. It was determined that inlet superheat has little effect on heat transfer coefficient and overall pressure drop, but that the corresponding effects of saturation temperature and mass flux are significant. 1. Introduction Major improvements in compact thermal devices have led to their application to a wide variety of technologies in the automotive, HVAC, oil/gas and aerospace industries. This rapid development of compact thermal devices has, in turn, increased research interest in developing the fundamental science and engineering of small-scale fluid flow and energy transport. The behavior of micro-devices is quite different from that of macro-scale devices. One of the major advantages of micro-devices over macrodevices is the increase in surface-to-volume ratio, which results in a proportional increase in the rate at which heat is rejected. Another effect of the diminished scale is the increased importance of surface forces and the diminished importance of body forces vs. surface tension for length-scales of less than 1 mm. In fact, friction is a major problem in micro-systems and is independent of the devices mass but proportional to its surface area. Compared with traditional heat exchangers with channels of conventional size, micro-channels exhibit superb heat transfer characteristics. Since micro-channels have an increased heat transfer surface area and a large surface-to-volume ratio, they provide a much higher heat transfer capacity for a given weight/volume of heat exchanger. This heat transfer capacity will allow for the development of highly compact heat exchangers, which will, in turn, lead to system-level miniaturization. The reduced size at the system level can potentially offer substantial savings in the costs of system fabrication, transportation of the units, and building space use. Furthermore, micro-channels can support high heat fluxes with small temperature gradients and thus minimize failure risks due to thermal stress. This is especially important for cooling high-flux electronics and the next generation of microprocessors. Considerable research has already been conducted on micro-scale single-phase flow phenomena, but most of this work has been driven by the needs of specific applications, from the original work of Tuckermann et al. [1] on cooling VLSI devices, to the work of Choi et al. [2] on using sub-cooled liquid N 2 to cool optical elements of a Giga-eV X-Ray radiation source. Results are available for only a limited range of flow characteristics and in many cases for relatively large flow channels, with dimensions on the order of millimeters rather than micrometers. In recent years researchers have also investigated two-phase flow; however, most of these investigations have focused on only a few parameters. This work has resulted in a few general microchannel condenser design correlations. But while this work has shed light on boiling heat transfer, little of it has focused on condensation, even though condensation in micro-channels is as important as boiling. A fundamental understanding of flow and heat transfer behavior of condensation at the micro-scale is essential for efficient design and analysis of systems and devices utilizing micro-scale structures. This is Abu Dhabi, U.A.E., November 4-5, 28 343

The Second International Energy 23 Conference particularly the case for condensation in micro-channels, where little or no previous work is available. Previous work on condensation is summarized in the paragraphs below. In a paper by Webb et al. [3] the two-phase flow was treated as an all-liquid flow with an equivalent Reynolds number, which was then used in a single-phase turbulent flow equation to predict condensation heat-transfer coefficient. The data used for the model verification were obtained for tubes with internal diameters ranging from 3.14 mm to 2 mm. However, the model was found to under-predict the experimental Nusselt number. Garimella and Coleman [4] presented a study of the effect of tube diameter and shape on the flow regime transitions for a co-current flow of air-water mixture in tubes with small hydraulic diameters ranging from 5.5 mm to 1.3 mm and velocities ranging from.1 to 1 m/s and.1 to 1. m/s. Although the studies were limited to adiabatic flow and are not directly applicable to phase-change situations, it was found that for tube diameters less than 1 mm, the combined effect of the tube diameter and surface tension suppresses the stratified regime and increases the intermittent flow regime. These effects are expected to be compounded in rectangular channels of similar hydraulic diameters, and more so for high aspect-ratio channels. Cavallini et al. [5] have presented results of two-phase flow frictional pressure drop data and condensation heat transfer coefficients using RI34a and R41a inside a flat multi-port, mini-channel tube. The results were for a tube with 1.4 mm hydraulic diameter and a length of 25.4 mm. Rose [6] presented a theoretical model to predict film condensation heat transfer from a vapor flowing horizontally in square and equilateral triangular sections of mini-channels or micro-channels. His model was based on fundamental analysis that assumed laminar condensate flow on the channel walls and took into account surface tension, interfacial shear stress, and gravity. Channel sizes ranged from.5 to 5 mm, withr134a, R22, and R41a as the working fluids. The channel wall temperature was considered uniform and the vapor was considered saturated at the inlet. The majority of the available studies on condensation in micro-channels are focused on circular or low aspect-ratio rectangular micro-channels. However two-phase flow patterns in the commonly used high aspect-ratio micro-channels are different from the low aspect-ratio micro-channels of the same hydraulic diameter, due to the ease of forming capillary bridges and cross-channel flow in the channels. The flow patterns significantly affect heat transfer and pressure drops, particularly in micro-channels where the effect of surface forces is significantly higher. The present work uses two different refrigerants to study the effect of saturation temperature, inlet superheat and mass flux on heat transfer coefficient and pressure drop in a rectangular, single micro-channel with hydraulic diameter of.7 mm. 2. Experimental Apparatus The experimental set-up was designed and built such that heat losses were minimal. A schematic diagram of the test facility is shown in Figure 1. The testing setup consisted of two loops: (1) the refrigerant loop and (2) the water-chilling loop. The refrigerant loop consisted of a high precision Coriolis flow meter, variable-speed gear pump, pre-heater, heater, test section, reservoir, and sub-cooler. The gear pump circulated the refrigerant at a precise flow rate; then, the refrigerant passed through a flow meter where the refrigerant flow rate was measured. The use of a gear pump instead of a compressor ensured that pure refrigerant was tested, rather than refrigerant contaminated with oil leakage from the compressor. The gear pump allowed us to accurately quantify the heat transfer coefficient and pressure drop in the micro-condenser. It also allowed us to conveniently set and adjust small mass flow rates of the refrigerant across a broad range. To control the operation pressure of the test loop, two electrical heaters were attached to the surface of the liquid reservoir. The heaters were connected to a Watlow PID controller as a means of pressure stabilization. The controller received a -5 Volt output signal from the absolute pressure transducer, determined the corresponding system pressure, and controlled the power input to the heaters on the reservoir, thereby controlling the system pressure by increasing and adjusting the reservoir temperature. To minimize heat loss, Dewar cylinder shells with a high vacuum between their walls were installed to insulate the test loops. The glass Dewar cylinders had diameters of 1 and 2 inches, respectively. The condenser and evaporator Dewars spanned the length of the condenser channel and evaporator tubes, respectively, as shown in Figure 4. In addition, the inner cylinder of the condenser Dewar acted as a water jacket. Figure 5 shows the details of the Dewar cylinders. In addition, a copper elbow connected the Dewar cylinders, as shown in Figure 4; the elbow had Kapton heater patches controlled by a PID temperature controller, which kept the surface temperature of the elbow equal to that of the inlet refrigerant and thus minimized heat loss from the inlet T-connection, which acted as an adiabatic thermal shield. Abu Dhabi, U.A.E., November 4-5, 28 344

The Second International Energy 23 Conference thermocouples Heater Chiller m water Reservoir PID Vacuumed Dewar Condenser Sight Glass Absolute Pressure Transducer ly p u S r e w o P r to ra o p a v E DP Coriolis flow meter r le o -c b u S Pre-Heater Filter m ref Pump Figure 12. Schematic of experimental test setup. Figure 13. Details of test section, (a) details of the joint between the condenser section and sight-glass,(b) details of the joint between the evaporator Dewar and condenser Dewar, and (c) view of the arrangement of various parts in the refrigeration loop. 3. Micro-channel Condenser Fabrication The micro-channel was fabricated from a long OFHC copper block. A slitting saw in a milling machine was used to construct the micro-channel. For the inlet and outlet of the condenser, two 1/8 inch holes were drilled at each end, and two stainless steel tubes were soldered in the holes. In addition, two 1/16 inch holes were drilled, each at the ends of the channel, for pressure drop measurements. Then, the channel was filled with jewelers wax, and the top surface was scraped flat and chemically cleaned in preparation for electroplating the channel. The channel was submerged into a copper-sulfate solution to be plated to the desired thickness on the remaining open surface of the channel. After electroplating, the wax in the channel was melted by heating the channel and then drained. Next, the channel was chemically cleaned to remove traces of wax or silver paint. On the outer surface of the channel, five single constantan wires and one copper wire were soldered to act as T-type thermocouples. The fabricated copper microchannel is shown Figures 3 and 4. Abu Dhabi, U.A.E., November 4-5, 28 345

The Second International Energy 23 Conference Figure 14. A drawing of the fabricated micro-channel. Channel Entranc e Pressure Port Figure 15. Electroplated micro-channel. 4. Test Fluids Two refrigerants, R134a and R245fa, were used in this investigation to broaden the range in values for the various parameters studied in this investigation. Table 1 shows a comparison of the refrigerants: R245fa has a slightly better latent heat, a different density, and a different surface tension than R134a. 5. Results Experimental tests were conducted to study the effect of three differen4t parameters on average heat transfer coefficient and pressure drop for the two refrigerants selected in this study. The parameters are presented in Table 2. Table 3. Comparison of refrigerant properties. R134a R245fa T sat ( o C) P sat (kpa) Conductivity (mw/m.k) Viscosity ( Pa.s) Density (kg/m 3 ) Enthalpy (kj/kg) Surface Tension (mn/m) liquid vapor liquid vapor liquid vapor liquid vapor 3 77 79. 14.33 185.8 12.4 1187.5 37.53 241.7 414.8 7.42 7 2116 61.7 2.45 16.4 14.65 996.2 115.6 34.3 428.7 2.61 3 179 79.2 12.52 376.4 1.51 1325.1 1.11 239.6 427.5 13.41 7 61 7.2 14.78 226.8 12. 124.7 33.43 295.7 456.6 8.35 Table 4. Range of testing parameters. Testing Parameters Range Mass Flux (kg/m 2 s) 5 5 Saturation Temperature (ºC) 3 7 Super Heat (ºC) - 15 Abu Dhabi, U.A.E., November 4-5, 28 346

The Second International Energy 23 Conference 6. Effect of Inlet Superheat 6.1 Average Heat Transfer Coefficient It is worth mentioning here that saturation temperature is used to calculate the average heat transfer coefficient. Since in this study only the average heat transfer coefficient was measured for the entire channel length, it was not feasible to find the heat transfer in the superheated region. This is because local heat transfer coefficient is required to calculate the length of the superheated region, from which heat transfer in that region can be estimated. Figure 16 and Figure 6 illustrate that as inlet superheat increases, the average heat transfer modestly increases. This could be because we used the saturation temperature as the liquid temperature in calculations of heat transfer coefficient in the superheated region or because the length of the annular flow region increased, which would cause more heat to be transferred than the heat transferred at the lower inlet superheat. The heat transfer difference between and 15ºC superheat was insignificant (1-15% of total heat transfer in the channel); and the local heat transfer coefficient at the inlet was significantly high; hence, the extra heat due to inlet superheat was quickly absorbed in the initial part of the channel. Another possibility is that if the heat transfer coefficient was significantly high at the inlet, a condensation film would be readily formed next to the walls while the fluid at the channel core was still at the superheated state. That is, a thermally non-equilibrium condition at each channel cross section would be formed. It is also obvious from the figures that the results of both refrigerants show similar patterns, which shows consistency in the data collection. In addition, R245fa has a higher heat transfer coefficient than that of R134a, which is mainly due to the higher latent heat of R245fa than that of R134a. 7 6 T sat = 5 o C 5 4 3 2 1 havg @ Mass Flux = 2 kg/m2s havg @ Mass Flux = 3 kg/m2s 5 1 15 2 Inlet Superheat ( o C) Figure 16. Effect of inlet superheat on average heat transfer coefficient at T sat = 5ºC for R134a. 1 9 Tsat = 5 o C 8 7 6 5 4 3 2 havg @ 2 kg/m2s 1 havg @ 3 kg/m2s 5 1 15 2 Inlet Superheat ( o C) Figure 17. Effect inlet superheat on average heat transfer coefficient at T sat = 5ºC for R245fa. Abu Dhabi, U.A.E., November 4-5, 28 347

The Second International Energy 23 Conference 6.2 Pressure Drop As a function of degree superheat at a given mass flux (2 & 3 kg/m 2 s) and at 5ºC saturation temperature, the pressure drop is almost constant at different superheats, as shown in Figure 18 and Figure 8. It is known that pressure drop of two-phase flows differs from one flow regime to another, which means that pressure drop is dependent on flow regime. Thus, it is believed that the flow pattern in the significant length of the channel (after the annular flow zone) is more or less the same as in the zero-superheat case. Since all the tests were conducted under the condition of 1% quality entering the condenser and % quality leaving the condenser, the overall flow pattern is not much different at various superheats and can be expected to be almost the same except at the inlet, where the annular flow is expected to be a bit longer in higher superheats. 7. Effect of Mass Flux 7.1 Average Heat Transfer Coefficient Figure 2 and Figure 1 show the effect of mass flux on average heat transfer for the refrigerants R134a and R245fa,respectively, at a fixed saturation temperature of 5ºC. This saturation temperature is chosen as the midpoint of the experimental range (3 7ºC). As seen in the figures, the heat transfer coefficient is positively affected by increasing the mass flux in the range of 5 5 kg/m 2 s. This is because the velocity is increased, enhancing the convection effects. The heat transfer coefficient is dominated by the thin-film condensation process, and when the velocity is increased, the annular flow regime becomes longer, therefore contributing to the increase in heat transfer. 12 T sat = 5 o C 1 8 6 4 2 Dp @ Mass Flux = 2 kg/m2s Dp @ Mass Flux = 3 kg/m2s 2 4 6 8 1 12 14 16 Inlet Super Heat ( o C) Figure 18. Effect of inlet superheat on pressure drop at T sat = 5ºC for R134a. 2 18 T sat = 5 o C 16 14 12 1 8 6 4 2 DP @ 2 kg/m2s DP @ 3 kg/m2s 5 1 15 2 Inlet Superheat ( o C) Figure 19. Effect of inlet superheat on pressure drop at T sat = 5ºC for R245fa. Abu Dhabi, U.A.E., November 4-5, 28 348

The Second International Energy 23 Conference 12 T sat = 5 o C 1 8 6 4 2 h @ Superheat = oc h @ Superheat =1 oc 1 2 3 4 5 6 Mass Flux (kg/m 2 s) Figure 2. Effect of mass flux on average heat transfer coefficient for R134a at T sat = 5ºC. 12 11 1 T sat = 5 o C 9 8 7 6 5 4 3 2 Inlet Super Heat oc 1 Inlet Super Heat 1 oc 1 2 3 4 5 6 Mass Flux (kg/m 2 s) Figure 21. Effect of mass flux on average heat transfer coefficient R245fa at T sat = 5ºC. When the performances of the two refrigerants in terms of average heat transfer coefficients are compared, it is clear that R245fa has on average 15% better heat transfer than that of R134a. For example, at mass flux of 3 kg/m 2 s the average heat transfer coefficient of R134a is 551 W/m 2 K, whereas for R245fa it is 618 W/m 2 K. 7.2 Pressure Drop It is known that pressure drop has a squared power relation with the velocity and hence is significantly affected by increase in the mass flux, as shown in Figure 22 and Figure 12. It is noteworthy that R245fa has almost three times higher pressure drop as R134a does. This is mainly due to the higher surface tension, liquid viscosity and vapor density values of R245fa. However, from these properties vapor density contributes the most to the increase in pressure drop because vapor is dominant in the channel. The vapor density of R245fa is more than three times lower than that of R134a (Table 3); therefore, the magnitude of pressure drop R245fa compared with R134a at the same mass flux is three times higher. Abu Dhabi, U.A.E., November 4-5, 28 349

The Second International Energy 23 Conference 25 T sat = 5 o C 2 15 1 5 Dp @ Superheat = oc Dp @ Superheat =1 oc 1 2 3 4 5 6 Mass FLux (kg/m 2 s) Figure 22. Effect of mass flux on pressure drop R134a at T sat = 5ºC. 5 45 T sat = 5 o C 4 35 3 25 2 15 1 Inlet Super Heat oc 5 Inlet Super Heat 1 oc 1 2 3 4 5 6 Mass Flux (kg/m 2 s) Figure 23. Effect of mass flux on pressure drop R245fa at T sat = 5ºC. 8. Effect of Saturation Temperature 8.1 Average Heat Transfer Coefficient Average heat transfer coefficient shows a descending trend with increasing saturation temperature, as shown in Figure 24 and Figure 14. This is mainly due to a reduction in the latent heat, h fg, as the saturation temperature increases from 3ºC to 7ºC. In addition, as system pressure increases with increased saturation temperature, the specific volume decreases, and as a result, the vapor velocity decreases, which reduces the heat transfer. Therefore, the heat transfer is higher at lower saturation temperatures. 8.2 Pressure Drop Increasing the saturation temperature significantly decreases the pressure drop, as seen in Figure 26 and 16. This is due to the sensitivity of pressure drop to liquid viscosity; hence, the pressure drop is higher at 3ºC than at 7ºC because the liquid viscosity is higher at 3ºC. Another factor that contributes to the decrease in pressure drop is saturation temperature: as saturation temperature increases, the volumetric flow rate decreases, thus lowering velocity and decreasing pressure drop. Abu Dhabi, U.A.E., November 4-5, 28 35

The Second International Energy 23 Conference 8 Inlet Super Heat = o C 7 6 5 4 3 2 1 Mass Flux = 2 kg/m2s Mass Flux = 3 kg/m2s 2 3 4 5 6 7 T sat ( o C) Figure 24. Effect of saturation temperature on average heat transfer coefficient for R134a. 1 9 Inlet Super Heat = o C 8 7 6 5 4 3 2 Mass Flux 2 kg/m2s 1 Mass Flux 3 kg/m2s 2 3 4 5 6 7 8 T sat ( o C) Figure 25. Effect of saturation temperature on average heat transfer coefficient for R245fa. 2 18 Inlet Super Heat = o C 16 14 12 Mass Flux = 2 kg/m2s Mass Flux = 3 kg/m2s 1 8 6 4 2 2 3 4 5 6 7 T sat ( o C) Figure 26. Effect of saturation temperature on pressure drop for R134a. Abu Dhabi, U.A.E., November 4-5, 28 351

The Second International Energy 23 Conference 35 3 Inlet Super Heat = o C 25 Mass Flux 2 kg/m2s 2 Mass Flux 3 kg/m2s 15 1 5 2 3 4 5 6 7 8 T sat ( o C) Figure 27. Effect of saturation temperature on pressure drop for R245fa. 9. Conclusions To characterize condensation heat transfer and pressure drop coefficients in micro-channels with small hydraulic diameter and high aspect ratio, a rectangular micro-channel made of copper, with dimensions of 19 mm 2.8 mm.4 mm, was fabricated. Parametric tests as a function of various controlling parameters were conducted for condensation of refrigerants R134a and R245fa. The study revealed that for both refrigerants the heat transfer and pressure drop coefficients decreased with an increase in the saturation temperature. The results also show that the average heat transfer coefficients were only slightly affected by changes in the inlet superheat; the corresponding effect on pressure drops was insignificant as well. As expected, an increase of both heat transfer coefficient and pressure drop was observed as mass flux increased. A comparison of the two refrigerants demonstrated that refrigerant R245fa on average has 15%-better heat transfer than that of R134a. However, the pressure drop for refrigerant R245fa was almost three times higher than that of R134a for the same operating conditions. 1. References 1. Tuckermann, D. B., Pease, R. F., & Nills, D. M.. High performance heat sinking for VLSI. IEEE Elect. Dev. Letter, Vol. 2 No. 5, (1981), pp. 126-129. 2. Choi, U. S., Rogers, C. S., & Mills, D. M.. High performance micro-channel heat exchanger for cooling high heat load X-Ray optical elements. ASME DSC, Vol.4, (1992), pp. 83-89. 3. Webb, R. L., & Zhang, M.,Heat transfer and friction in small diameter channels,presented at Workshop on Thermophysical Phenomena in Microscale Sensors, Devices and Structures, National Heat Transfer Conference. Baltimore, MD. (1997). 4. Coleman, J. W., Garimella, S., Characterization of two-phase flow patterns in small diameter round and rectangular tubes, International Journal of Heat and Mass Transfer, Vol. 42, (1999), pp. 2869-2881. 5. Cavallini A. et al., Condensation Heat Transfer and Pressure Gradient Inside Multiport Minichannels, Heat Transfer Engineering, Vol. 26, No. 3, (25), pp. 45-55. 6. Rose J. W. et al., A Theory of Film Condensation in Horizontal Noncircular Section Microchannels, Transaction of the ASME, Vol. 127, (25), pp. 196-115. Author Biographies Mr. Ebrahim Al-Hajri is a Ph.D. candidate and a Research Assistant in the Mechanical Engineering Department at the University of Maryland at College Park, U.S.A. He received his B.S. in mechanical engineering from the University of Arizona, and his M.S. in mechanical engineering from the University of Colorado. He is a member of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) and the American Society of Mechanical Engineers (ASME), and serves as a member and corresponding member in technical committees in both associations. He is also a member of the Association of Energy Engineers (AEE). Abu Dhabi, U.A.E., November 4-5, 28 352

The Second International Energy 23 Conference Dr. Serguei Dessiatoun is an Associate Research Professor in the Mechanical Engineering Department at the University of Maryland at College Park. He received his Ph.D. in mechanical engineering from the Moscow Automobile and Highway Technology Institute in 1988. He has over 7 publications in scientific journals, 3 technical reports, and more than 25 patents in the areas of energy conversion, heat transfer and fluid mechanics. Dr. Amir Shooshtari received his Ph.D. degree in mechanical engineering from the University of Maryland, College Park, in 24. Since 25, he has been a member of the research faculty at the University of Maryland. His research interests include electronic cooling, two-phase flow, fluid flow in porous media, and modeling of electrohydrodynamics. Dr. Shooshtari is the author or co-author of over 15 publications in international journals and conferences. He is a member of ASME and ASHRAE. Dr. Michael Ohadi is the Provost and Interim President of the Petroleum Institute. He received his Ph.D. from the University of Minnesota in 1986. He is internationally recognized for his work in enhanced heat and mass transfer in heat exchangers and energy systems. He has conducted many research projects for both industry and government. He has published over 14 refereed technical papers and is the author or co-author of nine U.S. patents. He is fellow of both ASME and ASHRAE, and has won numerous awards from both societies. He was recently featured in the technology section of the Washington Post for technology transfer efforts. Abu Dhabi, U.A.E., November 4-5, 28 353