INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

Similar documents
INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

Instruction Manual HI Refractometer for Sodium Chloride Measurements

MA882, MA883, MA884, MA885

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

HI Propylene Glycol Refractometer

Instruction Manual HI Refractometer for Invert Sugar Measurements

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

HI Seawater Refractometer

HI 96811, HI HI 96813, HI 96814

Instruction Manual HI 96759C Maple Syrup Transmittance Analyzer

SUGAR/BRIX REFRACTOMETER INSTRUCTION MANUAL

PHOTOMETER FOR BOAR SEMEN ANALYSIS

HI REDUCING SUGARS ISM for wine analysis

Today s Weather 24 Hour Forecaster

Instruction Manual HI 96738C Chlorine dioxide ISM

Instruction Manual HI 96728C Nitrate ISM

HI Hardness ISM

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

IR/Thermistor Pen. Instruction Manual

OPERATING INSTRUCTIONS

Bante210 Benchtop ph Meter Instruction Manual

Instruction Manual HI Potassium LR and MR ISM

Instruction Manual HI 96720C Calcium Hardness ISM

Instruction Manual HI 96710C ph & Chlorine ISM

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Rapid RH Portable ph Meter. User's Manual

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

HI HI 8633 HI HI 8734 HI

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

STANDARD OPERATING PROCEDURE

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

ph 5 Meter Manual The LaMotte 5 Series

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual

Eclipse Refractometer General Models

Advanced Sensor Technologies, Inc. TEL: TOLL FREE: WOW-ASTI ( ) FAX:

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

HI Free & Total Chlorine ISM

Portable ph/orp/ion Meter D-73 Instruction Manual CODE:GZ A

KD2. User s Manual. Thermal Properties Analyzer. version 6. Decagon Devices, Inc.

INE-PHS-3E ph Meter Operating Manual

LEAPERS, INC. RED/GREEN DOTS

GENERAL INSTRUCTIONS GENERAL PREPARATION

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

One-hand ph/temperature measuring instrument

InfraRed Thermometer with Laser Pointer

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

Operating Manual. Turb 355 IR/T. Portable turbidimeter. ba75454e03 09/

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

MS20 Laboratory Seawater Salinity and Density

DIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

INSTRUCTION MANUAL DTH Fax: (503)

Chematest 25. Operator s Manual A Swan Analytical Instruments AG CH-8340 Hinwil/Switzerland ANALYTICAL INSTRUMENTS

INSTRUCTION MANUAL. Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN Introduction Helpful Operating Tips. 2

Anemometer Thermometer Hygrometer

QAM-I-111 Operation and Calibration of the Conductivity Meter

WS-9018U Wireless Weather Station. Instruction Manual

The Synthesis and Analysis of Aspirin

Mini Environmental Quality Meter

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

ph / Temperature Meter for Cheese with Application Specific Probe

Bright Advance Corporation

TH2821B Portable LCR Meter

GENERAL INSTRUCTIONS GENERAL PREPARATION

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook

ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

Chemistry MultiMeasure Sensor PS-2170

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

Zetasizer Nano-ZS User Instructions

Dual laser + type K thermometer INFRARED THERMOMETER

Sensor Accessories. Rotary Motion Accessory Pack. Pendulum Rod with two masses, Angular Momentum disc set and Linear Rack with mini c-clamp

ION 5 and ION 6 Acorn Series Meters

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

Density of an Unknown

Instruction Manual SEFRAM Thermal Camera

Instruction Manual C401/301/201/102/101. Portable Colorimeter. 99 Washington Street Melrose, MA Phone Toll Free

VIBRATION METER. Instruction Manual.

Quick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Exercise 2-4. Titration of a Buffer Solution EXERCISE OBJECTIVES

LCS Laboratory Inc. 700 Collip Circle, Unit 218, London ON, N6G 4X8, (519) ,

Transcription:

Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements www.milwaukeeinst.com INSTRUCTION MANUAL www.milwaukeeinst.com 1

Instruction Manual MA888 Refractometer for Ethylene Glycol Measurements TABLE OF CONTENTS FUNCTIONAL DESCRIPTION... 3 GENERAL DESCRIPTION... 5 SPECIFICATIONS... 6 PRINCIPLE OF OPERATION... 6 MEASUREMENT UNITS... 8 MEASUREMENT GUIDELINES... 8 CALIBRATION PROCEDURE... 9 MEASUREMENT PROCEDURE... 10 CHANGING MEASUREMENT UNIT... 11 CHANGING TEMPERATURE UNIT... 12 MAKING A STANDARD SOLUTION... 12 ERROR MESSAGES... 13 BATTERY REPLACEMENT... 14 WARRANTY... 15 Remove the instrument from the packing materials and examine carefully to ensure no damage has occurred during shipping. If any damage has occurred, notify your Dealer. Each instrument is supplied with: 9 V battery Instruction manual Note: Save all packing material until you are sure that the instrument functions correctly. A defective instrument must be returned in its original packing. 2

www.milwaukeeinst.com FUNCTIONAL DESCRIPTION DISPLAY A. BATTERY STATUS ICON (BLINKS WHEN LOW BATTERY CONDITION DETECTED) B. MEASUREMENT IN PROGRESS TAG C. SETUP: FACTORY CALIBRATION TAG D. CAL: CALIBRATION TAG E. AUTOMATIC TEMPERATURE COMPENSATION (BLINKS WHEN TEMPERATURE EXCEEDS 10-40 C / 50-104 F RANGE) F. PRIMARY DISPLAY (DISPLAYS MEASUREMENT AND ERROR MESSAGES) G. TEMPERATURE UNITS H. SECONDARY DISPLAY (DISPLAYS TEMPERATURE MEASUREMENTS; WHEN BLINKING, TEMPERATURE HAS EXCEEDED OPERATION RANGE: 0-80 C / 32-176 F) I. RANGE INDICATOR 3

Instruction Manual MA888 Refractometer for Ethylene Glycol Measurements FRONT PANEL A. LIQUID CRYSTAL DISPLAY (LCD) B. READ KEY (USER MEASUREMENT) C. ZERO KEY (USER CALIBRATION) D. RANGE KEY (USER MEASUREMENT UNIT) E. ON/OFF F. STAINLESS STEEL SAMPLE WELL AND PRISM G. SECONDARY DISPLAY H. PRIMARY DISPLAY BOTTOM I. BATTERY COVER J. BATTERY COMPARTMENT 4

www.milwaukeeinst.com GENERAL DESCRIPTION SIGNIFICANCE OF USE Thank you for choosing Milwaukee. This instruction manual will provide you the necessary information for correct use of the meter. The MA888 is an optical instrument that employs the measurement of the refractive index to determine the % volume and freezing point of ethylene glycol based coolants or antifreeze. The digital refractometer eliminates the uncertainty associated with mechanical refractometers and is easily portable for use in the field to optimize your cooling system. The MA888 refractometer is an optical device that is simple and quick to use. Samples are measured after a simple user calibration with distilled or deionized water. Within seconds, the refractive index and temperature are measured and converted into one of two measurement units; % Volume or Freezing Point. The instrument utilizes internationally recognized references for unit conversion and temperature compensation for ethylene glycol solutions (e.g. CRC Handbook of Chemistry and Physics, 87 th Edition). The temperature (in C or F) is also displayed on the large dual level display along with helpful message codes. Key features include: Waterproof models offers IP65 waterproof protection Automatic Temperature Compensation (ATC) Battery operation with Low Power indicator Automatically turns off after 3 minutes of non-use. 5

Instruction Manual MA888 Refractometer for Ethylene Glycol Measurements SPECIFICATIONS % Volume F reezing Point C ( F) R ange: 0 to 100 % 0 to -50 C (32 to -58 F) 0 to 80 C (32 to 176 F) R esolution: 0.1 % 0.1 C (0.1 F) 0.1 C (0.1 F) A ccuracy: ± 0.2 % ± 0.5 (±1.0 F) ±0.3 C (±0.5 F) Light Source Yellow LED Measurement Time Approximately 1.5 seconds Minimum Sample Volume 100 μl (cover prism totally) Sample Cell Stainless Steel ring and flint glass prism Temperature Compensation Automatic between 0 and 40 C (32 to 104 F) Case Material ABS Enclosure Rating IP 65 Battery Type/Life 1 x 9 volt AA batteries / 5000 readings Auto-Shut off After 3 minutes of non-use Dimensions 19.2 x 10.2 x 6.7 cm (7.5 x 4 x 2.6") Weight 420 g (14.8 oz.). PRINCIPLE OF OPERATION Ethylene Glycol determinations are made by measuring the refractive index of a solution. Refractive Index is an optical characteristic of a substance and the number of dissolved particles in it. Refractive Index is defined as the ratio of the speed of light in empty space to the speed of light in the substance. A result of this property is that light will bend, or change direction, when it travels through a substance of different refractive index. This is called refraction. 6

www.milwaukeeinst.com When passing from a material with a higher to lower refractive index, there is a critical angle at which an incoming beam of light can no longer refract, but will instead be reflected off the interface. The critical angle can be used to easily calculate the refractive index according to the equation: sin (θ critical ) = n 2 / n 1 Where n 2 is the refractive index of the lower-density medium; n 1 is the refractive index of the higher-density medium. In the MA888 refractometer, light from an LED passes through a prism in contact with the sample. An image sensor determines the critical angle at which the light is no longer refracted through the sample. Specialized algorithms then apply temperature compensation to the measurement and convert the refractive index to: % Volume or Freezing Point. 7

Instruction Manual MA888 Refractometer for Ethylene Glycol Measurements MEASUREMENT UNITS Freezing point is displayed as a temperature from 0.0 to -50.0 C corresponding to 0-58 % by volume. The display blinks the freezing point when the concentration of Ethylene glycol is greater than 78 % concentration by volume. When the display shows LO, the freezing point is at a minimum (below -50 C). MEASUREMENT GUIDELINES Handle instrument carefully. Do not drop. Do not immerse instrument under water. Do not spray water to any part of instrument except the sample well located over the prism. The instrument is intended to measure ethylene glycol solutions. Do not expose instrument or prism to solvents that will damage it. This includes most organic solvents and extremely hot or cold solutions. Particulate matter in a sample may scratch the prism. Absorb sample with a soft tissue and rinse sample well with deionized or distilled water between samples. Use plastic pipettes to transfer all solutions. Do not use metallic tools such as needles, spoons or tweezers as these will scratch the prism. Cover sample well with hand if measuring in direct sun. 8

www.milwaukeeinst.com CALIBRATION PROCEDURE Calibration should be performed daily, before measurements are made, when the battery has been replaced, between a long series of measurements, or if environmental changes have occurred since the last calibration. 1. Press the ON/OFF key, then release. Two instrument test screens will be displayed briefly; all LCD segments followed by the percentage of remaining battery life. The meter will then briefly display an indication of the measurement unit set. When the LCD displays dashes, the instrument is ready. 2. Using a plastic pipette, fill the sample well with distilled or deionized water. Make sure the prism is completely covered. Note: If the ZERO sample is subject to intense light such as sunlight or another strong source, cover the sample well with your hand or other shade during the calibration. 3. Press the ZERO key. If no error messages appear, your unit is calibrated. (For a description of ERROR MESSAGES see page 13). 9

Instruction Manual MA888 Refractometer for Ethylene Glycol Measurements Note: The 0.0 screen will remain until a sample is measured or the instrument is turned off. 4. Gently absorb the ZERO water standard with a soft tissue. Use care not to scratch the prism surface. Dry the surface completely. The instrument is ready for sample measurement. Note: If instrument is turned off the calibration will not be lost. MEASUREMENT PROCEDURE Verify the instrument has been calibrated before taking measurements. 1. Wipe off prism surface located at the bottom of the sample well. Make sure the prism and sample well are completely dry. 2. Using a plastic pipette, drip sample onto the prism surface. Fill the well completely. Note: If the temperature of the sample differs significantly from the temperature of the instrument, wait approximately 1 minute to allow thermal equilibration. 3. Press the READ key. The results are displayed as % Volume or Freezing Point. 10

www.milwaukeeinst.com Note: The last measurement value will be displayed until the next sample is measured or the instrument is turned off. Temperature will be continuously updated. Note: The ATC tag blinks and automatic temperature compensation is disabled if the temperature exceeds the 0-40 C / 32-104 F range. 4. Remove sample from the sample well by absorbing with a soft tissue. 5. Using a plastic pipette, rinse prism and sample well with distilled or deionized water. Wipe dry. The instrument is ready for the next sample. CHANGING MEASUREMENT UNIT Press the RANGE key to select measurement units. The instrument toggles between the two measurement scales each time the key is pressed and the primary display indicates VoL % Volume or FrPt for Freezing Point. When the instrument displays the screen with 4 dashes, the instrument is ready for measurement. A number on the display indicates the selected unit: 1 denotes % Volume and 2 denotes Freezing Point (as indicated on the instrument cover). Note: The temperature measurement is not displayed in Freezing Point mode. 11

Instruction Manual MA888 Refractometer for Ethylene Glycol Measurements CHANGING TEMPERATURE UNIT To change the temperature measurement unit from Celsius to Fahrenheit (or vice versa), follow this procedure. 1. Press and hold the ON/OFF key continuously for approximately 8 seconds. The LCD will display the all segment screen followed by a screen with the model number on the primary display and the version number on the secondary display. Continue pressing the ON/OFF key. 8 seconds 2. While continuing to hold the ON/OFF key, press the ZERO key. The temperature unit will change from C to F or vice versa. Note: The selected unit will be used in Freezing Point mode. MAKING A STANDARD SOLUTION C or F To make an Ethylene Glycol Solution, follow the procedure below: To make an X % ethylene glycol solution volumetrically add X ml of high purity ethylene glycol (CAS #: 107-21-1; MW 62.068) to a 100 ml Grade A volumetric flask. Use distilled or deionized water to bring the flask close to the total volume, mix, allow the solution to return to room temperature. Once the solution has returned to room temperature use distilled or deionized water to bring the total volume to 100 ml. Mix solution well before use. Ethylene Glycol Total Volume Expected Freezing Point Value 10 % V 10.00 ml 100.00 ml -3.8 C (25.2 F) 40 % V 40.00 ml 100.00 ml -26.3 C (-15.4 F) 12

www.milwaukeeinst.com ERROR MESSAGES Err Error Code Description Genera l fa i l ure. Cycl e power to instrument. If error p e r s i s t s, c o n t a c t Milwaukee. LO Primary display Sample exceeds minimum measurement range. HI Primary display LO Primary display CAL segment ON HI Primary display CAL segment ON t LO Primary display CAL segment ON t HI Primary display CAL segment ON Sample exceeds maximum measurement range. Wrong solution used to z e r o i n s t r u m e n t. U s e deionized or distilled water. Press Z ero. Wrong solution used to z e r o i n s t r u m e n t. U s e deionized or distilled water. Press Z ero. Temperature exceeds ATC l ow l i m i t (0 C) d uri ng calibration. Temperature exceeds ATC high limit (40 C) during calibration. Air Prism surface insufficiently covered. ELt nlt Too much external light for m e a s u r e m e n t. C o v e r sample well with hand. LED light is not detected. Contact M ilwaukee. Battery segment blinking < 5 % o f b a t t e r y l i f e i s remaining. Temperature values are blinking 0.0 C or 80.0 C ATC segment SETUP segment blinking blinking Temperature measurement out of sampling range (0 to 80 C). O u t s i d e t e m p e r a t u r e compensation range (0 to 40 C). Factory calibration lost. Contact M ilwaukee. 13

Instruction Manual MA888 Refractometer for Ethylene Glycol Measurements BATTERY REPLACEMENT To replace the instrument s battery, follow these steps: Turn the instrument OFF by pressing the ON/OFF key. Turn instrument upside down and remove the battery cover by turning it counterclockwise. Extract the battery from its location. Replace with fresh 9V battery making certain to observe polarity. Insert the back battery cover and fasten it by turning clockwise to engage. 14

www.milwaukeeinst.com For your Safety don t use or store the instrument in hazardous environments. To avoid damages or burns, do not perform any measurement in microwave ovens. WARRANTY This instrument is warranted against defects in materials and manufacturing for a period of 2 years from the date of purchase. Electrodes are warranted for 6 months. If during this period the repair or replacement of parts is required, where the damage is not due to negligence or erroneous operation by the user, please return the instrument, electrode and probe to either distributor or our office and the repair will be effected free of charge. Damage due to accidents, misuse, tampering or lack of prescribed maintenance is not covered by the warranty. Milwaukee/Martini instruments reserves the right to make improvements in design, construction and appearance of its products without advance notice. 15

THANK YOU FOR CHOOSING Sales and Technical Service Contacts: Milwaukee Electronics Kft. Alsókikötő sor 11. 6726, Szeged, Hungary Tel: +36-62-428-050 Fax: +36-62-428-051 e-mail: sales@milwaukeeinst.com Milwaukee Instruments, Inc. 2950 Business Park Drive Rocky Mount, NC 27804 USA Tel: +1 252 443 3630 Fax: +1 252 443 1937 e-mail: sales@milwaukeetesters.com www.milwaukeeinst.com MANMA888 10/09