Application Note GCMS-01 Comparison of Ionization Techniques for the Analysis of Trace-Level Pyrethroid Insecticides by GC-MS/MS

Similar documents
Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

Sensitive Detection of Pyrethroids in Surface Water and Sediment

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

ENVIRONMENTAL analysis

PYRETHROID ANALYSIS. MARKET FOCUSED - Environmental TECHNICAL ARTICLE

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Highly Sensitive and Rugged GC/MS/MS Tool

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Application Note GCMS-03 Reliable high-throughput quantification of melamine and related analogs below regulatory limits in food using the EVOQ GC-TQ

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

A Method for Simultaneous Analysis of 174 Pesticides in Grape Using GC-MS/MS

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Strategies for Analysis of Pyrethroid Insecticides in Complex Matrices

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Sulfotepp impurities in Chlorpyrifos EC formulations

A Comprehensive, Fast, and Sensitive Method for the Quantitation of Synthetic Cannabinoids using the Elute UHPLC Coupled to an EVOQ LC-TQ MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Application Note No Introduction. DMI Instrumentation. DMI Method. DMI for Lettuce and Pea Extracts. Lettuce results

High Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry

Determination of urea in ultrapure water by IC-MS/MS

Pyrethroid Concentrations in Surface Water and Bed Sediment in High Agricultural Use Regions of California. Keith Starner and K.

Advantages of Reversed Sandwich Injection for Pesticide Residue Analysis

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Analysis of alkylphenols using GC-MS/MS and automated SRM development

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Fast and Accurate Quantitation of Perfluorinated Sources from Textiles using Gas Chromatography-Triple Quadrupole Mass Spectrometry

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Low level quantification of NDMA and non-targeted contaminants screening in drinking water using GC Orbitrap mass spectrometry

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Rapid, Robust, and Sensitive Detection of 11-nor-D 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair

Multi-residue analysis of pesticides by GC-HRMS

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Application Note FTMS-56 Reproducibility of Crude Oil Characterization by Flow Injection APPI-FT-ICR Mass Spectrometry

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Proven robustness for large-scale metabolomics studies using the Phenomics Workhorse

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

MRMS axelerate rapidly detected micropollutants and plant response metabolites in poplar leaves

GC Analysis of Polybrominated Flame Retardants Application

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

Enantiomeric and Diastereomeric Separations of Pyrethroids Using UPC 2

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

UCMR 3 Low-Level VOC Analysis by Purge and Trap Concentration and GC/MS using Selective Ion Monitoring

Derivatization Procedure and Negative Chemical Ionization GC/MS/MS Conditions for the Analysis of Steroidal Analogs

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Pyrethroid sediment toxicity data and risk assessment: challenges associated with highly hydrophobic chemicals

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan.

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Headspace Technology for GC and GC/MS: Features, benefits & applications

Blood Alcohol Determination using Static Headspace Analysis with Optimized Sample Throughput

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

STANDARD OPERATING PROCEDURES

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

At-a-Glance. Verapamil C 27 H 38 N 2 O 4 M+H + =

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

System and JUREK ANNE. Introduction: in an in purge and. trap sampling. Discussion: As part of. consistent and reliable data. (MoRT) to.

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

U.S. EPA Method 8270 for multicomponent analyte determination

ANNE JUREK. Abstract: soils and are found. in can also with GC/MS. poster. in series. option for. There are problems. analytes. in methanol.

CHAPTER 3 METHOD DEVELOPMENT FOR DETERMINATION OF PESTICIDES IN SOIL

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Transcription:

Application Note GCMS-01 Comparison of Ionization Techniques for the Analysis of Trace-Level Pyrethroid Insecticides by GC-MS/MS Abstract A study was carried out using the Bruker EVOQ GC-TQ to screen a group of pyrethroid insecticides at low concentrations in complex matrices including sewage outfall and ocean sediments. A comparison between electron impact and negative chemical ionization techniques in terms of the calibration range, method detection limits and precision was also conducted. The GC-MS/MS approach with MRM demonstrated excellent specificity and sensitivity overall, with negative chemical ionization demonstrating the best results for most of the pyrethroids studied. Authors Ed George Bruker Daltonics, Fremont, CA, USA Keywords Pyrethroid Insecticides GC-MS/MS EI NCI Instrumentation and Software EVOQ GC-TQ Introduction Pyrethroids are synthetic insecticides based on the structure of pyrethrins, derived from chrysanthemum flowers. The compounds are used in a range of household insecticides and repellents as they are stable, toxic and effective against a wide range of pests. Pyrethroids make their way into the environment through agricultural use and domestic control of mosquitos, and tend to persist in soils and sediments. The compounds are lethal to mayflies, gadflies and other invertebrates at extremely low levels, as well as being toxic to fish and other aquatic organisms.

Pyrethroids have been found to be unaffected by secondary treatment systems at municipal wastewater treatment facilities, often appearing in the effluent. State agencies in the USA such as the California Department of Food and Agriculture have implemented monitoring programs requiring low to sub-part-per-billion reporting limits in soil and water samples. In pesticide monitoring, discrimination against matrix components arising from waste water outfall (sewage) and sediment extracts is critical to the success of any method. Tandem GC-MS/MS is an ideal technique to analyze for synthetic pyrethroids, because it can discriminate effectively against matrix interferences and provide trace level detection. In this application note, a group of pyrethroids are analyzed with the EVOQ GC-TQ system. Electron impact (EI) and negative chemical ionization (NCI) techniques are optimized and compared in terms of calibration range, method detection limits and precision. Experimental GC-MS/MS Parameters Column: BR-5ms, 15 M x 0.25 mm id x 0.25 μm; Carrier gas: Helium at 1.0 ml/min; Oven: 60 o C (2min), at 50 o C /min to 150 o C (1 min), at 5 o C /min to 320 o C (hold 3 min); Injection: 2 μl pulsed splitless @ 28 o C with 4.0 mm ID fritted liner; Ion Source: EI @ 250 o C; NCI @ 150 o C; NCI Reagent Gas: Ammonia @ 20psi; (details see Table 1) Results and Discussion Calibration and instrument detection limits were determined for both NCI and EI modes. The calibration standards were prepared in dichloromethane with concentration range of 0.1 to 50 ppb. For EI, the average relative standard deviation (%RSD) and r 2 for all compounds was 8.7% and 0.9995 respectively. For NCI the average %RSD was 9.8% and r 2 was 0.9990. The added sensitivity observed for NCI allowed several compounds to have an extended lower calibration range, from 1 ppt to 5000 ppt. Calibration curve in EI for Piperonyl butoxide Instrumental EVOQ GC-TQ triple quadrupole mass spectrometer coupled to a Bruker 436 GC and CP-8400 liquid Autosampler. A standard hot splitless injection is used which reduces instrument matrix load as compared to the commonly used large volume programmed temperature vaporization (PTV). Figure 2: Example calibration curve in EI for Piperonyl butoxide, a synergist compound commonly added to pyrethroid formulations (0.1 to 50 ppb). Instrument detection limits (IDLs) were performed by analyzing seven replicates at 0.1 ppb prepared in dichloromethane and using the following equation: IDL = S t (n-1,1-alpha = 0.99) Where t (n-1,1-alpha = 0.99) = Student s t value for the 99% confidence level with n-1 degrees of freedom. Figure 1: EVOQ GC-TQ with 436 GC and CP-8400 autosampler. For EI/MS/MS IDLs ranged from 0.01 to 0.28 ppb with mean of 0.1 ppb and average %RSD of 10.6%. For NCI/ MS/MS IDLs were from 0.01 to 0.3 ppb with mean of 0.04 ppb and average %RSD of 6.1%. Analysis with NCI demonstrated excellent sensitivity for Fipronil, Fipronil sulfide, Fipronil sulfone, Esfenvalerate, Bifenthrin, Danitol and Deltramehtrin and IDLs were determined at 10 ppt with mean at 2.6 ppt and %RSD of 9.2%.

Table 1: MRM transitions for both NCI and EI modes for the compounds studied. Compound Name EI Q1 EI Q3 EI (CE) NCI Q1 NCI Q3 NCI (CE) cis/trans-permethrin 183 128-20 207.2 35.2 10 183 152-20 209.2 37.2 10 183 168-18 Fipronil sulfide 351 255-20 384 314.9 20 384 248 25 384 244 25 Esfenvalerate-A/B 225 91-25 211.2 35.2 20 225 119-18 211.2 167.2 10 225 147-10 Allethrin/Prallethrin 123 81-15 167.4 167.4 1 123 95-10 Fipronil sulfone 383 255-20 415.9 282.9 25 383 335-10 415.9 243.9 30 Danitol 181 152-25 141.4 141.4 1 181 127-30 Bifenthrin 181 115-40 386 205 5 181 165-18 386 161 15 181 166-10 Cyfluthrin isomers 206 151-15 207.2 35.2 20 206 179-20 171.2 35.2 20 226 206-10 Cypermethrin isomers 181 127-30 207.2 35.2 20 181 152-20 171.2 35.2 20 Deltamethrin 253 172-10 296.9 79 2 253 199-25 296.9 81 2 253 174-10 Fipronil 367 178-40 397.9 303.8 30 367 213-30 397.9 281.9 30 367 255-15 397.9 271.9 30 Piperonyl butoxide 176 131-10 ND ND ND 176 117-18 176 103-25 Cyhalothrin 208 181-10 241 205 20 181 152-20 241 35 10

Bifenthrin analyzed by NCI Figure 3: 10 ppt of Bifenthrin analyzed by NCI. Analysis of Complex Matrices 10 g ocean sediment was extracted in 50:50 DCM: Acetone with an accelerated solvent extraction technique (ASE) at 2000 psi and 125 oc, and the extracts were dried with sodium sulfate, evaporated to 1 ml without any further clean-up. 1 L of sewage outfall was prepared by continuous liquid-liquid extraction (CLLE) with DCM, dried and concentrated to 1 ml. A glass fritted 4 mm liner was used for the injections. Severe matrix interferences were noticed for several compounds in the EI method and resulted in very highly biased results. As can be seen on the right hand side of Figure 5, there are interferences in the EI/MS/MS analysis for the ocean sediment samples for Allethrin/Pallethrin, Cypermethrin isomers, and Deltamethrin at the transitions studied. Elevated baselines and distorted peaks encumber quantitation, even though the ion ratios are in range. The NCI/MS/MS analyses for the same sediment extract shown on the left hand side of Figure 5 demonstrate comparable results to the pure standard and give acceptable percent recoveries. Figure 4: Ocean extract (top) and sewage extract (bottom) used for matrix studies. The sewage samples exhibited similar interferences in EI/ MS/MS but to a lesser extent. Deltamethrin spiked sewage for example showed some elevation in baseline but gave a similar response compared to the calibration standard (Figure 6).

Comparison of NCI and EI extracted ion chromatograms NCI Cal std Palletrin/Allethrin EI Cal std Palletrin/Allethrin NCI Sediment EI Sediment NCI Cal std Cypermethrin EI Cal std Cypermethrin NCI Sediment EI Sediment NCI Cal std Deltamethrin EI Cal std Deltamethrin NCI Sediment EI Sediment Figure 5: Comparison of NCI (left) and EI (right) extracted ion chromatograms for (top to bottom) Allethrin/Pallethrin, Cypermethrin isomers, Deltamethrin. EI/MS/MS Figure 6: Deltamethrin in Cal standard (top) and sewage extract (bottom) by EI/MS/MS.

Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. Bruker Daltonics 04-2014, GCMS-01, 1837065 Conclusion This method demonstrates the benefits of using GC-MS/ MS with multiple reaction monitoring for low level pyrethroids analysis. In particular, excellent specificity and selectivity can be achieved in extremely complex matrices. The importance of evaluating the ionization technique alongside matrix to deliver improved performance is also demonstrated. In this case, NCI combined with MS/MS clearly provides the best results for most pyrethroids in the matrices studied. References [1] Pyrethroid pesticides in municipal wastewater: A baseline survey of publicly owned treatment works facilities in California in 2013, James C. Markle et al., January 22 2014. For research use only. Not for use in diagnostic procedures. Bruker Daltonik GmbH Bremen Germany Phone +49 (0)421-2205-0 Fax +49 (0)421-2205-103 Bruker Daltonics Inc. Billerica, MA USA Phone +1 (978) 663-3660 Fax +1 (978) 667-5993 ms.sales.bdal@bruker.com - www.bruker.com