Design and Analysis of dual Axis MEMS Capacitive Accelerometer

Similar documents
EE C245 / ME C218 INTRODUCTION TO MEMS DESIGN FALL 2011 C. Nguyen PROBLEM SET #7. Table 1: Gyroscope Modeling Parameters

EE C245 / ME C218 INTRODUCTION TO MEMS DESIGN FALL 2009 PROBLEM SET #7. Due (at 7 p.m.): Thursday, Dec. 10, 2009, in the EE C245 HW box in 240 Cory.

Dept. of Electrical & Computer Engineering, Dept. of Mechanical Engineering University of Bridgeport, Bridgeport, CT /08/2015

Analytical Design of Micro Electro Mechanical Systems (MEMS) based Piezoelectric Accelerometer for high g acceleration

Design and Simulation of Comb Drive Capacitive Accelerometer by Using MEMS Intellisuite Design Tool

Midterm 2 PROBLEM POINTS MAX

Design of a MEMS Capacitive Comb-drive Accelerometer

CHAPTER 4 DESIGN AND ANALYSIS OF CANTILEVER BEAM ELECTROSTATIC ACTUATORS

Modeling and Design of MEMS Accelerometer to detect vibrations on chest wall

Sensors & Transducers 2016 by IFSA Publishing, S. L.

Institute for Electron Microscopy and Nanoanalysis Graz Centre for Electron Microscopy

CHAPTER 5 FIXED GUIDED BEAM ANALYSIS

MEMS Tuning-Fork Gyroscope Mid-Term Report Amanda Bristow Travis Barton Stephen Nary

10 Measurement of Acceleration, Vibration and Shock Transducers

Kurukshetra University INDIA

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.2, pp ,

EE C245 ME C218 Introduction to MEMS Design Fall 2012

b. The displacement of the mass due to a constant acceleration a is x=

DESIGN AND SIMULATION OF ACCELEROMETER SPRINGS

EE C247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2014 PROBLEM SET #1

Four Degrees-of-Freedom Micromachined Gyroscope

Design and characterization of in-plane MEMS yaw rate sensor

Simple piezoresistive accelerometer

Optimizing the Performance of MEMS Electrostatic Comb Drive Actuator with Different Flexure Springs

E05 Resonator Design

High performance doubly clamped piezoresistive accelerometers by the outturn of electroplating

Capacitive MEMS Accelerometer Based on Silicon-on-Insulator Technology: Design, Simulation and Radiation Affect

Tunable MEMS Capacitor for RF Applications

Design And Analysis of Microcantilevers With Various Shapes Using COMSOL Multiphysics Software

Capacitive Sensor Interfaces

DESIGN AND ANALYSIS OF ROTATION RATE SENSOR. Modeling of vibratory MEMs Gyroscope

Y. C. Lee. Micro-Scale Engineering I Microelectromechanical Systems (MEMS)

Proceedings MEMS Inertial Switch for Military Applications

COMSOL Simulation of a Dualaxis MEMS Accelerometer with T-shape Beams

Foundations of MEMS. Chang Liu. McCormick School of Engineering and Applied Science Northwestern University. International Edition Contributions by

HSG-IMIT Application AG

Platform Isolation Using Out-of-plane Compliant Mechanism

19. Capacitive Accelerometers : A Case Study. 19. Capacitive Accelerometers : A Case Study. Introduction. Introduction (ctnd.)

Transducers. Today: Electrostatic Capacitive. EEL5225: Principles of MEMS Transducers (Fall 2003) Instructor: Dr. Hui-Kai Xie

Measurement Techniques for Engineers. Motion and Vibration Measurement

Slide 1. Temperatures Light (Optoelectronics) Magnetic Fields Strain Pressure Displacement and Rotation Acceleration Electronic Sensors

Design and Simulation of Micro-cantilever

Design And Analysis of Microcantilevers Type Sensor With Different Shape of Piezoresistive Patch

Possible Design Modification for Capacitive Type MEMS Accelerometer

EE C245 ME C218 Introduction to MEMS Design Fall 2007

INF5490 RF MEMS. LN03: Modeling, design and analysis. Spring 2008, Oddvar Søråsen Department of Informatics, UoO

MEMS INERTIAL POWER GENERATORS FOR BIOMEDICAL APPLICATIONS

Modelling of Different MEMS Pressure Sensors using COMSOL Multiphysics

Biosensors and Instrumentation: Tutorial 2

Performance Evaluation of MEMS Based Capacitive Pressure Sensor for Hearing Aid Application

Sensors & Actuators. Velocity and acceleration Sensors & Actuators - H.Sarmento

Finite Element Analysis of Piezoelectric Cantilever

Experimental analysis of spring hardening and softening nonlinearities in. microelectromechanical oscillators. Sarah Johnson

SENSORS and TRANSDUCERS

Electrical schematics for 1D analysis of a bridge type MEMS capacitive switch

Design Optimization of Mems Based Piezoelectric Energy Harvester For Low Frequency Applications

BaTiO 3 and TeO 2 based gyroscopes for guidance systems: FEM analysis

Piezoelectric Resonators ME 2082

EE C245 ME C218 Introduction to MEMS Design

Simulation of a Micro-Scale Out-of-plane Compliant Mechanism

Reduced Order Modeling Enables System Level Simulation of a MEMS Piezoelectric Energy Harvester with a Self-Supplied SSHI-Scheme

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Design and Simulation of Various Shapes of Cantilever for Piezoelectric Power Generator by Using Comsol

A single-layer micromachined tunable capacitor with an electrically floating plate

EECS C245 ME C218 Midterm Exam

ME 237: Mechanics of Microsystems : Lecture. Modeling Squeeze Film Effects in MEMS

SIMULATION AND OPTIMIZATION OF MEMS PIEZOELECTRIC ENERGY HARVESTER WITH A NON-TRADITIONAL GEOMETRY

Design and Analysis of Silicon Resonant Accelerometer

Variable Capacitance Accelerometers: Design and Applications

EE C245 ME C218 Introduction to MEMS Design Fall 2007

Piezoelectric Actuator for Micro Robot Used in Nanosatellite

Contactless Excitation of MEMS Resonant Sensors by Electromagnetic Driving

Design of Electrostatic Actuators for MOEMS Applications

Outline. 4 Mechanical Sensors Introduction General Mechanical properties Piezoresistivity Piezoresistive Sensors Capacitive sensors Applications

Introduction to Microeletromechanical Systems (MEMS) Lecture 9 Topics. MEMS Overview

JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, VOL. 13, NO. 5, OCTOBER Sudipto K. De and N. R. Aluru, Member, IEEE, Associate Member, ASME

Simulation based Analysis of Capacitive Pressure Sensor with COMSOL Multiphysics

Microstructure cantilever beam for current measurement

1. Narrative Overview Questions

NAVAL POSTGRADUATE SCHOOL THESIS

Single- and dual-axis lateral capacitive accelerometers based on CMOS-MEMS technology

Contactless Excitation of MEMS Resonant Sensors by Electromagnetic Driving

Transduction Based on Changes in the Energy Stored in an Electrical Field

Electrostatic Microgenerators

Comparative Analysis on Design and Simulation of Perforated Mems Capacitive Pressure Sensor

Simulation of a New PZT Energy Harvester with a Lower Resonance Frequency Using COMSOL Multiphysics. Zewail City Staff Sep, 2014

Micro Capacitive Tilt Sensor for Human Body Movement Detection

Accelerometer Theory & Design

EE C245 - ME C218 Introduction to MEMS Design Fall Today s Lecture

Microsensors. G.K. Ananthasuresh Professor, Mechanical Engineering Indian Institute of Science Bangalore, , India

Design of a Shock Immune MEMS Acceleration Sensor and Optimization by Genetic Algorithm

1220. Design considerations of a MEMS cantilever beam switch for pull-in under electrostatic force generated by means of vibrations

MODELING OF T-SHAPED MICROCANTILEVER RESONATORS. Margarita Narducci, Eduard Figueras, Isabel Gràcia, Luis Fonseca, Joaquin Santander, Carles Cané

Comparative Study on Capacitive Pressure Sensor for Structural Health Monitoring Applications

Numerical Study on the Quasi-periodic Behavior in Coupled. MEMS Resonators

PARAMETRIC ANALYSIS ON THE DESIGN OF RF MEMS SERIES SWITCHES

DESIGN AND FABRICATION OF THE MICRO- ACCELEROMETER USING PIEZOELECTRIC THIN FILMS

MEMS design and fabrication of an electrostatic vibration-to-electricity energy converter

Applicability of Self-Powered Synchronized Electric Charge Extraction (SECE) Circuit for Piezoelectric Energy Harvesting

DESIGN AND OPTIMIZATION OF BULK MICROMACHINED ACCELEROMETER FOR SPACE APPLICATIONS

Transcription:

International Journal of Electronics Engineering Research. ISSN 0975-6450 Volume 9, Number 5 (2017) pp. 779-790 Research India Publications http://www.ripublication.com Design and Analysis of dual Axis MEMS Capacitive Accelerometer 1 Kamal Prakash Pandey Research scholar, Department of Electronics & Communication Engineering, SHUATS, Allahabad, UP-211007, India 2 Anil Kumar Assistant Professor, Department of Electronics & Communication Engineering, SHUATS, Allahabad, UP-211007, India Abstract In current scenario the application of MEMS accelerometer is increasing rapidly in our day-to-day life; different approaches have been successfully developed in order to design high sensitive and high-resolution accelerometers. This paper reports a novel approach to design an MEMS accelerometer for dual axis sensing. Capacitive approach is used in accelerometer design and is based on different type of supports provided to the proof mass. Designing and modeling of the device is carried out on the COMSOL Multiphysics a 3-D simulation tool based on SOI-MUMP S technology provided by the MEMSCAP foundry. Keywords: Capacitive; Comb configuration; Dual axis sensing; Lateral movement; Transverse movement; I. INTRODUCTION Micro-electro-mechanical system (MEMS) accelerometer is one of the most important inertial sensor in the MEMS industry having wide application area. Over the last three decades extensive efforts have been made to develop highly efficient, precise and robust Micromachinedinertial sensors mainly accelerometers and gyroscopes. Accelerometer is a device that senses the acceleration, force, shock, vibrations etc. and converts it into an equivalent voltage form with the help of some external digital circuitry. Different types of accelerometers are well developed and available in the market for various applications. Accelerometers are classified on the ground of either fabrication technique [1][2] or sensing technique. There are mainly two techniques to fabricate accelerometers, which are bulk-micromachining, a subtractive process and surface micromachining,

780 Kamal Prakash Pandey and Anil Kumar an additive process [3]. Capacitive and piezoresistive sensing techniques are the two dominant techniques whereas some other less popular techniques are piezoelectric, thermal, optical and current tunneling. Capacitive sensing technique is used to design accelerometer in the paper here presented due to its different advantages over other techniques. Capacitive approach based accelerometers have high resolution, good DC response, linear output, low power dissipation [4], high sensitivity and easy incorporation with CMOS IC [5]. The acceleration determination is based on the change of capacitance between the capacitors plates when an acceleration/displacement producing force changes the plate positions [6-8]. II. ACCELEROMETER DESIGN A basic accelerometer is modeled as a simple spring-mass-damper system as shown in Fig 1. Fig 1. Basic accelerometer model. When under the influence of some force the accelerometer is excited towards its sensing axis y than due to inertial force the proof mass moves in the direction opposite to it. Displacement of proof mass per unit of gravitational acceleration describes the mechanical sensitivity of an accelerometer. The basic equation of the spring-mass-damper system is given by m 2 x x + d + kx = F = ma (1) t2 t Where, m= proof mass, d=damping coefficient, k=spring stiffness, a=acceleration and x= displacement of proof mass. III. PROPOSED ACCELEROMETER MODEL The accelerometer designed in this paper is for dual axis sensing application. Sensing axis depends upon how many axis an accelerometer can freely displaced on the application of force. Change in capacitance depends upon the change in overlapping area of plates or change in distance between plates.in this paper we have incorporated both the sensing techniques to determine the acceleration. A cantilever beam support is provided to provide out-of-plane movement which results in change of capacitance

Design and Analysis of dual Axis MEMS Capacitive Accelerometer 781 due to the change in the overlapping area of the plates. Spring attached to the proof mass is responsible for the in-plane transverse movement which results in change in capacitance due to the change in distance between the plates. The accelerometer structure with dual axis sensing mechanism is shown in Fig 2. Fig 2. Proposed accelerometer model. A rectangular proof mass is at the center of the design at which the force is applied, a series of comb structure and spring support is directly attached to the proof mass. For the transverse movement of proof mass the maximum displacement of proof mass should always less than the gap between the fingers or capacitive plates, large displacement may damage the comb fingers. A series of comb fingers are attached to sense the change of capacitance, capacitance incorporated per pair of fingers increases as the number of fingers increased. IV. SIMULATION AND ANALYSIS Accelerometer performance depends upon the supports provided to the proof mass. System operating frequency, proof mass displacement depends upon the modeling of support attached to the proof mass. A. Proof mass support modeling The proof mass support provided in this design is basically a combination of two types of support which is a beam and a spring. Beam support has no effect of the spring movement while the effect of spring can t be ignored when movement is associated with beam support. The structure of support is shown in Fig 3.

782 Kamal Prakash Pandey and Anil Kumar Fig 3. Spring and beam support provided to proof mass. Anchored point is kept fix and proof mass is attached to the free point. The parameter of the support for the designed accelerometer is shown in table 1. Table 1. Proof Mass Support Parameters Parameters Beam Spring Length 20 100 Width 10 5 Height 10 10 1) Mass associated with proof mass support The total mass of the proof mass support is given by the sum of spring, beam and connecting points. Support mass = 0.055896 µg. 2) Spring stiffness: The spring stiffness (K) depends upon the number of folds, length, width and height of the spring, which is given by k α = 1 hw3 E α l 3 Where α= number of folds, E= young s modulus, h= height of spring, w= spring flexure width, l= spring flexure length. k α =643.94 kn/m 3) Resonance frequency of proof mass support when movement is associated with spring support:the spring support is responsible for in-plane movement, the force is applied in the direction to compress and expand the spring. The resonance frequency

Design and Analysis of dual Axis MEMS Capacitive Accelerometer 783 with the parameters from table 1 is 1.75 MHz and bandwidth 1 MHz as shown in Fig 4. Fig 4. Resonance frequency of support provided to proof mass. 4) Effect of change in spring finger height on the free point displacement: As the spring flexure height increases the mass of spring increases and the effect on the displacement of free point is analyzed as shown in Fig 6. Fig 6. Free point displacement Vs. structure height for different frequencies. As the structure height increases the displacement of free end decreases for all the frequency range. The system shows maximum displacement for the height of 2µm as shown in Fig 7.

784 Kamal Prakash Pandey and Anil Kumar Fig 7. Total displacement vs. frequency for different height. 5) Resonance frequency of proof mass support when the movement is associated with beam support: Beam support is responsible for the movement of proof mass in out-ofplane, force applied on proof mass oscillates the system in the direction of its height, the maximum displacement should be less than or equal to the height of the whole structure. The resonance frequency of the support is found as 1.1 MHz and the bandwidth as 1 MHz as shown in Fig 8. Fig 8. System resonance frequency for beam support. 6) Effect of change in beam support height on the free end displacement: Change in free end displacement for various beam height at different frequency is observed as shown in Fig 9.

Design and Analysis of dual Axis MEMS Capacitive Accelerometer 785 Fig 9. Free point displacement vs. beam height for different frequency range. Fig 10. Total displacement vs. frequency for different beam height. The free point displacement decreases with increase in the beam height. B. Accelerometer modeling The accelerometer is now modeled using the spring and beam support, pair of comb structures are attached to the proof mass, parameters of accelerometer model are shown in table 2. Table 2. Accelerometer Parameters Parameters Comb Proof mass Length(µm) - 200 Width(µm) - 100 Finger length(µm) 50 - Finger width(µm) 5 - Finger overlap(µm) 2.5 - Finger gap(µm) 40 - Capacitor pair 52 - Height 10 10

786 Kamal Prakash Pandey and Anil Kumar 1) Analytical analysis: The analytical analysis is carried out to determine the accelerometer total mass and capacitance, the total mass for the accelerometer, when the chosen material is silicon with density of 2329 Kg/m 3, is given by Mass TOTAL= Proof mass+comb finger mass+support mass Mass TOTAL= 0.892 µg Capacitance per pair of finger is given by c = ε A d Where ε=permittivity of the material between fingers, A=overlapping area, d= distance between two consecutive fingers [6]. C=1.41667 nf Total number of capacitors = 52 Total capacitance = 73.6668 nf 2) Frequency domain analysis: The frequency domain analysis is carried out to determine the system resonance frequency and bandwidth. a) Analysis for in-plane sensing: During in-plane sensing spring support is used and the proof mass oscillates in transverse direction. As the proof mass and comb fingers are attached to the spring support there is change in system resonance frequency which is observed as 0.3 MHzand bandwidth as 0.4 MHz as shown in Fig 11. Fig 11. Resonance frequency for in plane sensing. b) Analysis for out-of-plane sensing: beam support is used to determine the out of plane sensing, an force producing acceleration is applied on the proof mass which oscillates it in the out-of-plane direction, the capacitance change is now due to the change in overlapping area. The system resonance frequency and bandwidth is observed as 0.32 MHz and 0.25 MHz respectively as shown in Fig 12.

Design and Analysis of dual Axis MEMS Capacitive Accelerometer 787 Fig 12. Accelerometer resonance frequency for out-of-plane sensing. 3) Eigen frequency analysis: This analysis is performed to determine the system displacement at different Eigen frequencies. a) Analysis for in-plane sensing: The system performance is observed for different Eigen frequencies as shown in Fig 13. Fig 13 (a). Eigen frequency of 0.3229 MHz and a maximum displacement of 2.9176 µm.

788 Kamal Prakash Pandey and Anil Kumar Fig 13 (b). Eigen frequency of 0.724 MHz and a maximum displacement of 4.0316 µm. Fig 13 (c). Eigen frequency of 1.28 MHz and a maximum displacement of 4.848µm. With the increase in system frequency the chances of device failure and damage increases. b) Analysis for out-of-plane sensing:the system performance is observed for different Eigen frequencies as shown in Fig 14.

Design and Analysis of dual Axis MEMS Capacitive Accelerometer 789 Fig 14 (a). Eigen frequency of 0.3229 MHz and a maximum displacement of 2.917 µm. Fig 14 (b). Eigen frequency of 7.24 MHz and a maximum displacement of 4.031 µm. Fig 14 (c). Eigen frequency of 1.2835 MHz and a maximum displacement of 4.8489 µm.

790 Kamal Prakash Pandey and Anil Kumar V. RESULTS AND CONCLUSION The accelerometer is designed for dual axis sensing, the accelerometer resonance frequency for in-plane sensing is 0.3 MHz having bandwidth of 0.4 MHz and the resonance frequency for out-of-plane sensing is 0.32 MHz with bandwidth of 0.25 MHz The designed accelerometer is applicable in moderate frequency applications. REFERENCES [1] Rebeiz, G.M.; Muldavin, J.B., "RF MEMS switches and switch circuits," Microwave Magazine, IEEE, vol.2, no.4, pp.59-71, 2001. [2] S. Pacheco, et al., Microwave and Optoelectronics Conference,p. 770-777, 2007. [3] http://www.memsnet.org/mems/what-is.html. [4] Amini BV, Ayazi F (2004) A 2.5-V 14-bit CMOS SOI capacitive accelerometer. IEEE J Sold-State Circuits 39(12):2467 2476. [5] G.Kovacs, Micromachined Transducers Sourcebook; New York: McGraw Hill, 1998. [6] Chi Yuan Lee, Guan Wei Wu, Wei Jung Hsieh, Fabrication of micro sensors on a flexible substrate, Sens.Actuators A:Phys.(2008). [7] P. Bruschi et al, A method for cross-sensitivity and pull-in voltage measurement of MEMS two-axis accelerometers, Sensors and Actuators A 123 124 (2005). [8] Norwood, MA, ADXL202E: Low-cost _2 g dual-axis accelerometer with duty cycle output, Analog Devices, 2003. [9] James Doscher et. Al, Analogue Dialogue Volume 33, Number 6, June, 1999. [10] http://www.analog.com/imems/products/adxl202_top.html.