EXPERIMENTS CHARACTERIZING THE X-RAY EMISSION FROM A SOLID-STATE CATHODE USING A HIGH-CURRENT GLOW DISCHARGE

Similar documents
EXCESS HEAT PRODUCTION IN Pd/D DURING PERIODIC PULSE DISCHARGE CURRENT IN VARIOUS CONDITIONS

RESEARCH INTO LOW ENERGY NUCLEAR REACTIONS IN CATHODE SAMPLE SOLID WITH PRODUCTION OF EXCESS HEAT, STABLE AND RADIOACTIVE IMPURITY NUCLIDES.

CATHODE MATERIAL CHANGE AFTER DEUTERIUM GLOW DISCHARGE EXPERIMENTS

Radionuclide Imaging MII Detection of Nuclear Emission

ANOMALOUS ENHANCEMENT OF DD-REACTION, ALPHA- EMISSION AND X RAY GENERATION IN THE HIGH- CURRENT PULSING DEUTERIUM GLOW-DISCHARGE WITH

Proportional Counters

Advances in the Micro-Hole & Strip Plate gaseous detector

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

Nuclear product ratio for glow discharge in deuterium

Detection and measurement of gamma-radiation by gammaspectroscopy

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

ATOMIC WORLD P.1. ejected photoelectrons. current amplifier. photomultiplier tube (PMT)

INTENSE NON-LINEAR SOFT X-RAY EMISSION FROM A HYDRIDE TARGET DURING PULSED D BOMBARDMENT

EEE4106Z Radiation Interactions & Detection

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Research on a Phonon-Driven Solid-State X-Ray Laser

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

Neutron Transport Calculations Using Monte-Carlo Methods. Sean Lourette Fairport High School Advisor: Christian Stoeckl

Volume Production of D - Negative Ions in Low-Pressure D 2 Plasmas - Negative Ion Densities versus Plasma Parameters -

Basic physics Questions

Ion Implanter Cyclotron Apparatus System

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

TRITIUM PRODUCTION CROSS SECTION FOR NEUTRON INTERACTION WITH 10 B NUCLEI

Quality Assurance. Purity control. Polycrystalline Ingots

The Mössbauer Effect

Alpha-particle Stopping Powers in Air and Argon

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Figure 1. Decay Scheme for 60Co

INFLUENCE OF PARAMETERS OF THE GLOW DISCHARGE ON CHANGE OF STRUCTURE AND THE ISOTOPE COMPOSITION OF THE CATHODE MATERIALS

Radiation Detection and Measurement

First Beam Profile Measurements Based on Light Radiation of Atoms Excited by the Particle Beam

Gamma Emission Evaluation in Tungsten Irradiated By Low Energy Deuterium Ions

Signal to noise Source of noise Signal to noise enhancement

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

NUCLEAR EMISSIONS FROM TITANIUM HYDRIDE/DEUTERIDE INDUCED BY POWERFUL PICOSECOND LASER BEAM

Plasma Accelerator for Detection of Hidden Objects by Using Nanosecond Impulse Neutron Inspection System (NINIS)

Radiation Detection and Measurement

Bolometry. H. Kroegler Assciazione Euratom-ENEA sulla Fusione, Frascati (Italy)

AUTORADIOGRAPHY OF DEUTERATED Ti AND Pd TARGETS FOR SPATIALLY RESOLVED DETECTION OF TRITIUM PRODUCED BY COLD FUSION

Rad T 290 Worksheet 2

Two-electron systems

Chemistry (

Particle Detectors and Quantum Physics (2) Stefan Westerhoff Columbia University NYSPT Summer Institute 2002

EMISSION REGISTRATION ON FILMS DURING GLOW DISCHARGE EXPERIMENTS

PHYSICAL VAPOR DEPOSITION OF THIN FILMS

08 - Miscellaneous and historical detectors

A Report On DESIGN OF NEUTRON SOURCES AND INVESTIGATION OF NEUTRON BASED TECHNIQUES FOR THE DETECTION OF EXPLOSIVE MATERIALS

Lecture # 3. Muhammad Irfan Asghar National Centre for Physics. First School on LHC physics

A UNIQUE ELECTRIC DISCHARGE-EXCITED SOLID STATE X-RAY LASER

Shielded Scintillator for Neutron Characterization

PECULIARITIES OF FORMING THE RADIATION SITUATION AT AN AREA OF NSC KIPT ACCELERATORS LOCATION

R&D on Astroparticles Detectors. (Activity on CSN )

Multiple charge states of titanium ions in laser produced plasma

SiPM & Plastic Scintillator

Digital two-parametric processing of the output data from radiation detectors

Chapter Seven (Nuclear Detectors)

Investigation of Water Fragments

188 L. Jakubowski and M.J. Sadowski temperature. Some examples of the registered X-ray images are shown in Fig.1. Figure 1. X-ray pinhole images from

LAAPD Performance Measurements in Liquid Xenon

Secondary ion mass spectrometry (SIMS)

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

Atomic and nuclear physics

Chapiter VII: Ionization chamber

Radiation Detection and Measurement

Chapter 4 Scintillation Detectors

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Measuring Cosmic Ray Muon Decay Constant and Flux

Radioactivity and Ionizing Radiation

PHB5. PHYSICS (SPECIFICATION B) Unit 5 Fields and their Applications. General Certificate of Education January 2004 Advanced Level Examination

Muon Telescope at BEO Moussala *

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

Fadei Komarov Alexander Kamyshan

NEUTRINO DINEUTRON REACTIONS (LOW-ENERGY NUCLEAR REACTIONS INDUCED BY D 2 GAS PERMEATION THROUGH PD COMPLEXES. Y. IWAMURA EFFECT)

Ba (Z = 56) W (Z = 74) preferred target Mo (Z = 42) Pb (Z = 82) Pd (Z = 64)

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

1.5. The Tools of the Trade!

Experiments on detection of cosmic ether

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Radioactivity. Lecture 6 Detectors and Instrumentation

Gamma and X-Ray Detection

RADIATION DETECTION AND MEASUREMENT

RADIOACTIVITY Q32 P1 A radioactive carbon 14 decay to Nitrogen by beta emission as below 14 x 0

Absolute activity measurement

Sparks in Gases: Line Spectra

An extremity (wrist) dosemeter based on the Landauer InLight TM whole body dosemeter

Diffractometer. Geometry Optics Detectors

Detecting high energy photons. Interactions of photons with matter Properties of detectors (with examples)

Laser heating of noble gas droplet sprays: EUV source efficiency considerations

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Fig.1 Pyrex glass cell

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

MEASUREMENT AND DETECTION OF RADIATION

Analysis of Nuclear Transmutation Induced from Metal Plus Multibody-Fusion-Products Reaction

Chapter Six: X-Rays. 6.1 Discovery of X-rays

Transcription:

EXPERIMENTS CHARACTERIZING THE X-RAY EMISSION FROM A SOLID-STATE CATHODE USING A HIGH-CURRENT GLOW DISCHARGE A.B. KARABUT AND S.A. KOLOMEYCHENKO FSUE SIA LUCH 24 Zheleznodorozhnaja Street, Podolsk, Moscow Region 142100, Russia Tel.: (095) 5508129; fax: (095) 5508129; E-mail: 7850.g23@g23.relcom.ru X-ray emission (with intensity up to 0.01 Gy/s) was recorded in research on a possible mechanism of initiating nuclear transmutation reactions in a solid-state cathode medium in glow discharge experiments. The experiments were carried using a glow discharge 1 with deuterium and hydrogen (at pressures up to 10 Torr), and using various cathode metals (Al, Sc, Ti, Ni, Nb, Zr, Mo, Pd, Ta, W, Pt and Pb). The x-rays were recorded using thermoluminescent detectors, x-ray film, and scintillation detectors with photomultipliers. Two different modes of the emission were observed during these experiments: (1) Diffusion x-rays were observed as separate x-ray bursts (up to 10 5 bursts a second and up to 10 6 x-ray quanta in a burst) with an average x-rays energy (from measurements using thermoluminescent detectors) in the range of 1.3 1.8keV. (2) X-rays as laser microbeams (up to 10 4 beams a second and up to 10 9 x-ray quanta in a burst). The emission of the x-ray laser beams occurred during the discharge, and within 100ms after turning off the discharge current. The results obtained constitute a direct experimental proof for the existence of excited metastable energy levels with energies in the range 1.2 5.0keV, within the solid-state cathode sample. 1. Introduction Previous experiments were carried out to clarify possible mechanism involved in the initiation of nuclear transmutation reactions in the solid-state cathode of a highcurrent glow discharge. The experimental results showed that the character of the detected x-ray radiation differed essentially from known x-ray emission types. Such results are significant, and we have been motivated to pursue the problem further. 2. Experiment scheme The experiments were carried out with a high-current glow discharge, using deuterium and hydrogen. The cathode samples (made of Pd and other metals) were placed on the cathode holder below an output window for penetrating radiation. The window was covered by a 15 µm thick Be foil for protecting the detectors against optical and ultraviolet radiation. A pulse-periodic power supply with a rectangular current pulse shape was used to drive the glow discharge. The duration of the 585

August 4, 2005 23:6 WSPC/Trim Size: 9.75in x 6.5in for Proceedings KaraB 586 Figure 1. Various variants of the experimental device: (a) system of a scintillator PM placed at a distance of 21 cm from the cathode, (b) system of a scintillator PM placed at a distance of 70 cm from the cathode, (c) system of a scintillator PM placed at a distance of 70 cm from the cathode with superimposition of the cross magnetic field. discharge current pulses was 0.27 10.0ms, and the time between impulses was 1.0 100 ms. The discharge was carried out in D 2, Xe, and Kr. X-ray recording was carried out using thermoluminescent detectors, x-ray film placed above the cathode at various distances, and scintillation detectors supplied with photomultipliers. We used scintillation detectors (with photomultipliers) to study the characteristics of the penetrating radiation in space and in time. The signal from the photomultiplier was transferred to a fast preamplifier (with an amplification constant of k = 7) and then to the two-channel computer digital oscilloscope (with a frequency resolution of 50 MHz per channel). Organic scintillators based on polymethylmetacrelate (PMMA) (with a luminescence time of 3 5 ns) were used. The time resolution of the entire path from the photomultiplier to the oscilloscope determined experimentally to be 70 80ns. Electrical pickup was absent in all the path from the photomultiplier to the oscilloscope, as was checked during special experiments using a light-absorbing shield installed between the photomultiplier and the scintillator. Electrical noise was observed only when passing the leading edge and trailing edge of the rectangular current pulses feeding the glow discharge.

587 Three different ways of assembling the discharge chamber (with a channel for extracting the radiation) were used as shown in Fig. 1. In the first variant (Fig. 1a), the scintillator detector (and photomultiplier) was placed at a distance of 21 cm from the cathode surface. The channel diameter for extracting the radiation was 1.7 cm. In the second variant, the scintillator-photomultiplier detector was placed at a distance of 70 cm from the cathode; in this case, the diameter of the channel for extracting the radiation was 3.2 cm (Fig. 1b). For determining the penetrating radiation type, a third variant of the experimental assembly (included a magnetic system consisting of a constant magnet and an elliptic iron magnetic circuit as shown in Fig. 1c) was used. The axis of the poles of the magnetic system was at a distance of 35 cm from the cathode, perpendicular to the axes of the radiation extraction channel. The magnetic field strength in the gap between poles was 0.2 T. The intensity of the luminous flux from the scintillator in the mode of generating the x-ray laser beams was approximately 1000 times (and more) as much as the intensity of the luminous radiation of the scintillator in the mode of diffusion bursts. In this case, a light-absorbing filter attenuating the luminous flux by 50 times was installed between the scintillator and photomultiplier. 3. Procedure and results for diffusion x-rays bursts Procedures for measuring and recording were developed and applied to the two modes of x-ray emission: diffuse radiation bursts, and x-ray generation as laser microbeams. The intensity of the luminous flux from the scintillator in the beam mode was approximately 1000 times as much as the intensity of the luminous radiation of the scintillator for bursts in the diffusion mode. In this case, the amplification constant of the radiation recording system was changed by modifying the supply voltage of the photomultiplier, and by changing the amplification constant of the oscilloscope. During some experiments, the light-absorbing filter attenuating the luminous flux coming to photomultiplier was installed between the scintillator and photomultiplier. Two types of the filters attenuating the luminous flux (by 50 times, and by 2500 times) were used. The x-rays energy and intensity were determined in the case of the diffusion mode. The dependence (calibration) of the x-ray intensity (power associated with an exposure x-ray dosage) on the output signal of the scintillator-photomultiplier was determined during glow discharge experiments when both the scintillatorphotomultiplier and thermoluminescence detectors were used. The thermoluminescence detectors, in the form of disks with a diameter of 5 mm and thickness of 1 mm, were arranged in the holes of the special housing cartridge at a distance of 11 cm from the cathode. A set of beryllium foils (with thickness of 15, 30, 60, 105, 165, 225 and 300 µm) was arranged in the housing holes on the side of the radiation input (where foils of different thickness were arranged in each hole). Two thermoluminescence detectors were placed outside the chamber for recording the background value of the radiation dose. The thermoluminescence detectors were exposed during the experiment (up to 2300 s), and then the dose absorbed

588 Figure 2. Typical oscillograms of the x-ray emission signal from the scintillator-photomultiplier system covered with the Be foil with different thickness: (a) covered with a 15 µm Be shield, (b) coveredwitha30µm Be shield. In this experiment the cathode sample is Pd-D 2 ; the discharge current is 150mA. Inset: (1) the Be screen of 15 µm; (2) scintillator; (3) photomultiplier. by each detector during exposure was determined. The x-ray associated power was determined by dividing the dose amount by the period of the experiment. The power per unit mass absorbed by the detector (in the solid angle in the direction from the cathode) was determined as the exposure dose power divided by the detector mass. The determination of the x-ray energy was made by changing the radiation dose absorbed by the thermoluminescence detectors with Be shields of various thickness. The x-ray intensity (number of photons per second) incident on the detector was determined by dividing the radiation energy absorbed by the detector by the energy of an x-ray photon. Further, the intensity falling on a detector was given to 2π solid angle. For the scintillator-photomultiplier detector, the relative intensity of the x- rays was defined as the sum total of the amplitudes ΣA i for all of the x-ray bursts within a time interval of 1 s (Fig. 2). Then the relative intensity was converted to a physical magnitude by the intensity value measured by the thermoluminescence detectors. Experiments made with the system of the scintillator-photomultiplier detector and shields made of beryllium foil (with thickness of 15 and 30 µm) gave an estimate

589 Figure 3. The typical oscillograms of bursts of the diffusive x-ray emission (PM scintillator) during passing the discharge current. The system Ta D 2, current is 175 ma. (a) PM scintillator arrange at a distance of 21 cm from cathode (by Fig. 1a); (b) PM scintillator arrange at a distance of 70 cm from cathode (by Fig. 1b). of the x-ray energy value of E x-ray 1.5 kev, which was well matched the result from the thermoluminescence detectors. This is shown in Fig. 2. The dependence of the radiation intensity on the distance was determined using the experimental arrangements shown in Fig. 1a,b. An increase in the distance between the scintillator-photomultiplier detector and the cathode from 21 cm to 70 cm resulted in a decrease in the radiation intensity faster than would be expected accordingtoa1/r 2 law (Fig. 3). Such result could be explained by the fact that the radiation pattern of separate bursts had an elliptic shape with a narrow angular orientation. 4. Results for x-ray laser beam bursts Generation of x-ray laser beams occurred under precise fixed discharge parameters and conditions: (1) Beam generation occurred only in the presence of a pulse-periodic current (there is no x-ray beam generation under direct current operation, whereas x-ray bursts of the diffusion radiation occured also with direct current). (2) Some critical parameters associated with beam generation were the gas pressure of P GD (in the discharge chamber) and the discharge voltage U GD.Thex-raybeam generation occurred for P GD <P GDcrit,andU GD >U GDcrit. Minor changes in the discharge pressure, and in the discharge voltage, would result in beam generation

590 Figure 4. Typical oscillograms of bursts from x-ray laser beams (scintillator-photomultiplier) during the discharge with different gases: (a) D 2 ; (b) Xe; (c) Kr. The assembly used is that of Fig. 1a; the cathode sample is Pd; and the discharge current is 50 ma. Asterisk (*) means that the pulse peak was chopped by the amplifier. (for example, the pressure the change was P GD = 0.2 0.3 Torr, and the voltage change was U GD =30to50V). (3) These (critical) parameters were different for various cathode materials (e.g. when using a Pd cathode, x-ray laser generation occurred at a pressure twice as high as when using a Ti cathode. (4) The parameters for the occurence of x-ray laser generation also depended on the (plasma-forming) gas. (5) During operation, the beam intensity decreased in due course (obviously because of a degradation of the cathode surface), and stopped completely in the course of time. This phenomenon was especially well observed for cathode materials with a large coefficient for material sputtering in the discharge plasma (e.g. Al, Pd, Pb). The x-rays as laser beams consisted of separate beams, presumably; each hav-

591 Figure 5. Typical oscillograms of bursts from x-ray laser beams for the scintillatorphotomultiplier, in the presence of a discharge in D 2, for different kinds of cathode samples: (a) Al; (b) Sc; (c) Pb; (d) Ta. The experimental configuration is that shown in Fig. 1a. Asterisk (*) means that the pulse peak was chopped by the amplifier. ing a small diameter (up to 10 6 10 9 photons in a beam). These magnitudes were obtained in assumption that the scintillator-photomultiplier detector operated in a linear regime, taking into account the reduction in the magnitude of the amplification constant of the path when recording the x-ray laser radiation. The x-ray laser beam emission occurred during the discharge, and for 100 ms after the current was turned off. At the specific parameters of the discharge the generation of the x-ray laser beams was observed only some milliseconds later after turning off the discharge current (up to 20 30 beams after each current pulse). The time oscillograms type of the generated beams depended on the type of (plasma-forming) gas (Fig. 4), and

592 Figure 6. Typical oscillograms of bursts from x-ray laser beams (scintillator-photomultiplier) in the discharge for different kind of assemblies. The cathode sample is Ta; the discharge gas is D 2 ; and the discharge current is 100mA. (a) Assembly used is that of Fig. 1a; (b) assembly used is that of Fig. 1b; (c) assembly used is that of Fig. 1c. Asterisk (*) means that the pulse peak was chopped by the amplifier. on the cathode metal used (Fig. 5). In this case, the amplification constant of the recording path was enough large so that the upper part of pulses was cut off by the amplifier discriminator. The true form of the radiation pulses was observed using the light-absorbing filter, which reduced the luminous flux from the scintillator to the photomultiplier a factor of 2500 (Fig. 6). Estimates for x-ray laser beam divergence was carried out in experiments that used experimental configurations as shown in Fig. 1a,b. An increase of the distance from the cathode to the scintillator-photomultiplier detector from 21 cm to 70 cm (Fig. 7) resulted in an insignificant reduction in the signal. These results proved to be true when using a 50 optical filter (attenuator) between the scintillator and photomultiplier (Fig. 8).

593 Figure 7. Schematic of an experiment (primary penetration radiation research) with an optical filter between photomultiplier and scintillator. The optical filter decreases the light flux by a factor of 50: (1) cathode sample; (2) anode; (3) 15 µm Be foil screens; (4) scintillator; (5) photomultiplier; (7) 50 optical filter (attenuator). Experiments carried out with a cross magnetic field showed that the radiation had two components (Fig. 1c). The x-ray laser beams did not diverge in the magnetic field, and were recorded by the scintillator-photomultiplier detector. The other part of the radiation did not hit on the detector (in the presence of the magnetic field). Hypothetically, this part of the radiation was fast electrons with an energy of 0.5 MeV. The fast electron beams can be formed when primary x-ray laser beams interact with the walls of the channel for extracting the radiation. The track images of the x-ray laser beams were obtained using x-ray film placed above the cathode at various distances. The diameter of the laser beams tracks was 6 10 µm at a distance of 100 mm from the cathode; and up to 20 30 µm ata distance of 210 mm (Fig. 9). The high intensity of the radiation, and the process of photoemulsion solarization, gave the tracks a positive image. The angular divergence of each beam was estimated to be up to 10 4 (from the results of tracks diameter measurements at the various distances from the cathode).

594 Figure 8. Typical oscillograms of bursts from x-ray laser beams (scintillator-photomultiplier with optical attenuator) in the discharge for different kind of assemblies: (a) the cathode sample is Ta; (b) the cathode sample is Mo; the discharge current is 100 ma, D 2. (a) Assembly used is that shown in Fig. 1a; (b) assembly used is that shown in Fig. 1b. Asterisk (*) means that the pulse peak was chopped by the amplifier. 5. Discussion The features of the x-ray emission recorded during these experiments are the following: The x-rays leave the solid-state medium of the cathode material. The intensity of the x-rays increases by 5 6 times when the discharge voltage is increased by 1.3 1.4 times. The x-rays energy is not changed essentially in this case. The x-ray emission occurs within 100 ms after turning off the discharge current. The results obtained constitute a direct experimental proof of the existence of excited metastable energy levels, with the energies in the range of 1.5 2 kev in the solid cathode sample. These excited metastable levels are presumably formed in the volume of separate crystallites. These excited metastable levels exist for a time of τ mst (up to 100 ms, and more). Then the destruction of these levels by relaxation takes place, accompanied with the emission of x-rays and fast electrons. Beams generation occurs in the solid-state cathode medium, presumably from a single pass of amplification. In this case, the duration of the beams should be on the order of

595 Figure 9. The increased negative image of the flare spots of the x-ray laser beam tracks for different distances from cathode. The x-ray film Kodak XBM was covered with the 15 µm Al shield. The cathode sample was Pd-D 2 ; the discharge current is 130 ma; the exposure time is 1000 s; (a) for 100 mm from the cathode surface; (b) for 210 mm from the cathode surface. The image is negative. 10 11 10 13 s. A clarification of the physical mechanism for the formation of these levels requires the additional research. The existence of one of the two following possible physical phenomena can be assumed: Excitation of the interior L and M electronic shells without ionization of the outer electrons. Vibrational deformation of the electron-nuclear system of the solid ions. The core of electronic shells is displaced relative to a nucleus, forming a dipole (an optical polar phonon). The frequency of this formed phonon is much greater than the plasma frequency in a metal. 6. Conclusion The experimental research of this fundamental phenomenon has allowed to create an essentially new type of the device: The x-ray solid-state laser, with a wavelength of 0.6 0.8nm, with a duration of individual pulses on the order of 10 11 10 13 s, andwithabeampowerinthepulsesupto10 7 W. References 1. A.B. Karabut, Research into powerful solid x-ray laser (wavelength is 0.8 1.2 nm) with excitation of high current glow discharge ions, in Proceedings of the 11th International Conference on Emerging Nuclear Energy Systems, 29 September 4 October 2002, Albuquerque, New Mexico, USA, pp. 374 381.

596 2. Richard B. Firestone, Table of Isotopes, Eighth Edition, Vol. 2, Appendix G-1, John Wiley & Sons Inc., New York (1996). 3. Raymond C. Elton, X-Ray Lasers, Academic Press Inc. (1990).