EXPERIMENT 7. Determination of Sodium by Flame Atomic-Emission Spectroscopy

Similar documents
Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

Determination of Orthophosphate Ion

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Density of Aqueous Sodium Chloride Solutions

FLAME PHOTOMETRY AIM INTRODUCTION

Determination of Orthophosphate Ion

Density of Aqueous Sodium Chloride Solutions

Part II. Cu(OH)2(s) CuO(s)

Chemical Reactions: The Copper Cycle

Experiment 20-Acid-Base Titration: Standardization of KOH and Determination of the Molarity and/or Percent Composition of an Acid Solution

Learn to do quantitative titration reactions. Observe the mole ratios of several simple chemical reactions.

Experimental Procedure Lab 402

The Fluorometric Determination of Acetylsalicylic Acid in an Aspirin Tablet

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

EXPERIMENT 4. Identifying a Substance by Acid-Base Titration

Skill Building Activity 2 Determining the Concentration of a Species using a Vernier Spectrometer

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

EXPERIMENT 2. Gravimetric Analysis of a Soluble Chloride

GETTING THE END POINT TO APPROXIMATE. Two hours

EXPERIMENT. Stoichiometry of a Precipitation Reaction

Ascorbic Acid Titration of Vitamin C Tablets

Experiment 8 Introduction to Volumetric Techniques I. Objectives

Ascorbic Acid Titration of Vitamin C Tablets

CHEM Practice to be done before the lab. Experiment 9 Introduction to Volumetric Techniques II. Objectives

GENERAL INSTRUCTIONS GENERAL PREPARATION

Identification of an Unknown Compound through Mass Correlations

Chem 2115 Experiment #7. Volumetric Analysis & Consumer Chemistry Standardization of an unknown solution, analysis of vinegar & antacid tablets

Western Carolina University

Title: FLAME TESTS. sodium chloride. calcium nitrate. potassium nitrate. strontium nitrate. copper(ii) nitrate. lithium nitrate. nitrate.

THE IRON(III) THIOCYANATE REACTION SYSTEM

Test Method: CPSC-CH-E

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Solubility Product Constants

Spectrophotometric Determination of Ferrocyanide in Effluents

EXPERIMENT #3 A Beer's Law Study

6. Common Laboratory Techniques

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

Experiment 7A ANALYSIS OF BRASS

(b) Write the chemical equation for the dissolution of NaOH in water.

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

Experiment 7: ACID-BASE TITRATION: STANDARDIZATION OF A SOLUTION

Flushing Out the Moles in Lab: The Reaction of Calcium Chloride with Carbonate Salts

Sodium Chloride - Analytical Standard

TYPES OF CHEMICAL REACTIONS

Introduction to Small Scale Chemistry

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

NaOH (aq) + HCl (aq) NaCl (aq) + H 2 O (l)

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

EXPERIMENT 22 SOLUBILITY OF A SLIGHTLY SOLUBLE ELECTROLYTE

Molarity of Acetic Acid in Vinegar A Titration Experiment

Chemistry 151 Last Updated Dec Lab 8: Precipitation Reactions and Limiting Reagents

EXPERIMENT A4: PRECIPITATION REACTION AND THE LIMITING REAGENT. Learning Outcomes. Introduction

CHEM 122 LABORATORY SKILLS EXAMINATION

REVIEW OF LAB TECHNIQUES

Substances and Mixtures:Separating a Mixture into Its Components

PART II: ANALYSIS OF IRON COORDINATION COMPOUND

Introduction to Spectroscopy: Analysis of Copper Ore

Bellevue College CHEM& 121 Experiment: Stoichiometric Analysis of an Antacid 1

Ascorbic Acid Titration of Vitamin C Tablets

ASCORBIC ACID METHOD FOR PHOSPHORUS DETERMINATION

Ascorbic Acid Titration of Vitamin C Tablets

Titration with an Acid and a Base

EXPERIMENT 16 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

CHEM 30A EXPERIMENT 8 & 9: ACID- BASE TITRATION. Learning Outcomes. Introduction. Upon completion of this lab, the student will be able to:

Chemistry Calibration of a Pipet and Acid Titration

Experimental Procedure. Lab 406

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

Water Hardness and Softening (Bring a water sample from home) Minneapolis Community and Technical College Principles of Chemistry II, C1152 v.2.

Chesapeake Campus Chemistry 111 Laboratory

# 12 ph-titration of Strong Acids with Strong Bases

Chapter 9. Volumetric Analysis

EXPERIMENT A7: VINEGAR TITRATION. Learning Outcomes. Introduction. Upon completion of this lab, the student will be able to:

Chem 2115 Experiment #7. Volumetric Analysis & Consumer Chemistry Standardization of an unknown solution and the analysis of antacid tablets

Basic Equipments and Instruments used in Chemistry laboratory: Balance: It is an instrument for measuring mass.

CHEM 334 Quantitative Analysis Laboratory

Introduction to Spectroscopy: Analysis of Copper Ore

Experiment 17. Synthesis of Aspirin. Introduction

H 3 O + (aq) + P 2- (aq)

Chemical Reactions: Titrations

Percentage of Acetic Acid in Vinegar

Introduction to Spectroscopy: Analysis of Copper Ore

THE TEMPERATURE DEPENDENCE OF THE EQUILIBRIUM CONSTANT

Copper (II) Glycinate Titration

To use calorimetry results to calculate the specific heat of an unknown metal. To determine heat of reaction ( H) from calorimetry measurements.

Experiment 2: Analysis of Commercial Bleach Solutions

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

Laboratory 3. Development of an Equation. Objectives. Introduction

Experiment #5. Empirical Formula

Density of an Unknown

Reactivity of Halide Ions

Sodium Chloride - Analytical Standard

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

Lab #3 ph and Buffers

1) A ph/mv meter or an ion meter, either line operated or portable.

POGIL LAB EXERCISE 15 HOW DO YOU STANDARDIZE AN ACID AND BASE?

Reaction Stoichiometry

Titration of an Unknown Acid

Synthesis and Analysis of a Coordination Compound

Exercise 6: Determination of Hardness of Water

The Cole-Parmer Ammonium Ion Electrode is used to quickly, simply, accurately, and economically measure ammonium ions in aqueous solutions.

Transcription:

EXPERIMENT 7 Determination of Sodium by Flame Atomic-Emission Spectroscopy USE ONLY DEIONIZED WATER (NOT DISTILLED WATER!) THROUGHOUT THE ENTIRE EXPERIMENT Distilled water actually has too much sodium in it. Clean all glassware and rinse thoroughly with deionized water both before and after use. There is sufficient sodium in tap water and even distilled water to invalidate your results. Remember also to rinse out your plastic wash bottle several times and then fill it with deionized water. SAFETY WARNING CAUTION Although the natural-gas/oxygen flame is rather small, it has such a high temperature that contact of the flesh with even the outer edge of the flame will instantly produce a third-degree burn. Except for lighting the flame, hands should be kept completely out of the chimney or burner housing whenever the flame is burning. In addition, NEVER put your hand above the burner housing. UNKNOWN Submit a clean, labeled 100-mL volumetric flask to the instructor so that your unknown sodium solution can be issued. Your name, section number, and your locker number should be written legibly on this flask. The flask does not need to be dry on the inside, but needs to have been rinsed with deionized water thoroughly after it has been washed. The flask must be turned in at least 1 lab period before you plan to do the experiment so that the Teaching Assistants will have time to prepare the unknown. Each student will have his or her own unknown to analyze even if working in pairs. BACKGROUND Flame photometry, now more properly called flame atomic emission spectrometry, is a relatively old instrumental analysis method. Its origins date back to Bunsen s flame color tests for the qualitative identification of select metallic elements. Probably the most common example of the atomic emission effect is fireworks for 4 th of July celebrations and other events. As an analytical method, atomic emission is a fast, simple, and sensitive method for the determination of trace metal ions in solution. Because of the very narrow (ca. 0.01 nm) and characteristic emission CHE 226 Analytical Chemistry Laboratory 40 Na Atomic Emission

lines from the gas-phase atoms in the flame plasma, the method is relatively free of interferences from other elements. Typical precision and accuracy for analysis of dilute aqueous solutions with no major interferences present are about ±1-5% relative. The method is suitable for many metallic elements, especially for those metals that are easily excited to higher energy levels at the relatively cool temperatures of typical flames Na, K, Ca, Rb, Cs, Cu, and Ba. Metalloids and nonmetals generally do not produce isolated neutral atoms in a flame, but rather mostly neutral, polyatomic radicals and ions. Therefore, nonmetallic elements are not suitable for determination by flame emission spectroscopy, except for a very few and under very specialized conditions. Flame photometry is a highly empirical, rather than an absolute, method of analysis such as gravimetry. That is, you must calibrate the method carefully and frequently. Many different experimental variables affect the intensity of light emitted from the flame. Therefore, careful and frequent calibration is required for good results. INSTRUMENTATION Coleman Flame Photometer, Model 21 The Coleman flame photometer represents very old technology indeed. It once found extensive use in clinical labs and even operating rooms to determine sodium, calcium, and potassium in various bodily fluids. This use has been supplanted by more modern, safer, faster, and more accurate methods. The instrument uses a total-consumption burner to aspirate aqueous solutions into a natural-gas/oxygen flame. Wavelength isolation is by use of a simple interference filter that is designed to transmit only the strong, characteristic sodium-doublet lines at 589.2 nm. [Different filters must be used to transmit the calcium line at 442.7 nm and the two potassium lines at 766.5 and 769.9 nm.] A glass lens is used to focus the light from the flame onto the end of a fiber optic cable, a light pipe, which transmits the light onto a photodiode located in the small home-built electronics box by the flame photometer. The electronics therein convert the diode s output into a digital display. EQUIPMENT NEEDED Wash bottle(s) rinsed several times and then filled with deionized water One 1-L volumetric flask, from your locker 10- and 25-mL volumetric pipets, or a 50-mL burette, from your locker Five 100-mL volumetric flasks, available in the locker for this experiment Eight to ten small glass containers (aspiration cups) used for aspirating solutions into the flame photometer. These are provided in the locker drawer for this experiment. CHE 226 Analytical Chemistry Laboratory 41 Na Atomic Emission

PREPARATION OF SOLUTIONS Standard Sodium Stock Solution, 100.0 ppm 1. Accurately (to 0.1 mg) weigh out by difference 0.1271 g of reagent grade NaCl into a small plastic weighing boat. It is very difficult and time consuming to weigh out this amount exactly. Get it as close as you can, record the exact weight, and correct your concentrations accordingly. Remember: NEVER transfer chemicals inside an analytical balance. 2. Carefully transfer the salt quantitatively into a 500-mL volumetric flask. Use a few squirts of deionized water from your wash bottle on the weighing boat and the sides of the flask to wash all of it down into the flask. [0.100 g Na/L = 100 mg/l = 100 µg/ml = 100 ppm Na). 3. Add about 100 ml of deionized water to the flask, swirl several times, and dissolve all of the salt before diluting to volume with deionized water. This is critical. Sodium Standard Calibration Solutions 1. Pipet 10.00, 20.00, 30.00, 40.00, and 50.00 ml of the standard 100-ppm sodium solution into the first, second, third, fourth, and fifth 100-mL volumetric flasks, respectively. 2. Dilute carefully to the mark with deionized water and mix thoroughly. 3. Use deionized water for the blank. Unknown Solution Obtain the unknown from the instructor and carefully dilute to the 100-mL mark with deionized water. Mix thoroughly. PROCEDURE Carefully follow the instructions provided you for use of the instrument and determine the emission intensity for each standard, the blank (deionized water), and the unknown. 1. When ready to take emission readings, call the Teaching Assistant to light the flame, stabilize the flame photometer, and instruct you in its proper and safe use. 2. Aspirate deionized water from a small glass container that is designed to fit into the instrument for at least 2-3 minutes to clean out and stabilize the unit. While aspirating deionized water, set the ZERO knob on the digital readout unit to 0.0 units. There will be some bounce or fluctuation in the meter reading. 3. Aspirate the most concentrated standard solution, and use the GAIN knob to set the reading to 100.0 units. CHE 226 Analytical Chemistry Laboratory 42 Na Atomic Emission

4. Recheck the zero setting with deionized water and the 100 setting again with the most concentrated standard. Repeat if necessary. The instrument may drift substantially while its temperature is stabilizing, and more slowly throughout the experiment. 5. Now aspirate all the standards and unknowns in turn, starting with the least concentrated standard solution. Aspirate deionized water in between each Na solution to clean the unit out. The burner displays a memory effect. It takes a while to clean it out the previous solution aspirated. 6. Repeat steps 2-4 a second time to get a good duplicate set of measurements, then repeat the whole sequence a third time. 7. When done, aspirate deionized water for at least 2-3 minutes. 8. Call the Teaching Assistant to shut down the photometer. 9. Clean your work areas up. HAZARDOUS WASTE DISPOSAL Essentially there is NO hazardous waste involved in this experiment. All we are dealing with are dilute solutions of ordinary table salt. Empty ALL the solutions down a sink drain with cold water running. Rinse all glassware with distilled water and then rinse the 100-mL volumetric flasks and the glass aspiration cups with deionized water. DATA TREATMENT Prepare a calibration curve by plotting the emission intensities as a function of Na concentration. Determine the concentration of sodium in the unknown sample by reading the concentration of the sample which corresponds to its emission intensity from the calibration curve. Depending on the drift in the instrument and other factors, it may be better to average all three values for each solution and obtain one final value for the unknown, or to get three separate values for the unknown, each using its own calibration curve, and average the three values. Try both to see if one approach seems to be better than the other. If the plot appears to be linear, or at least that portion of it that includes your unknown, use some software to run a linear-leastsquares fit to the data. Report the best estimate for the average concentration of sodium in ppm (µg/ml) and the associated standard deviation of the value. CHE 226 Analytical Chemistry Laboratory 43 Na Atomic Emission

TEXT REFERENCE D. A. Skoog, D. M. West, F. J. Holler, and S. R. Crouch, Analytical Chemistry: An Introduction, 7th ed., Chapter 23, pp. 594-631. Revised January 24, 2005 Copyright by The Department of Chemistry,, 2005 CHE 226 Analytical Chemistry Laboratory 44 Na Atomic Emission