ELECTROMAGNETIC RADIATION HAZARDS

Similar documents
Computation of Electromagnetic Energy Absorption in the Human Body Tissues by High Frequency Structure Simulator

SCITECH Volume 4, Issue 1 RESEARCH ORGANISATION November 09, 2017

Study of Specific Absorption Rate (SAR) in the human head by metamaterial attachment

Research. Ji Chen Department of Electrical and Computer Engineering University of Houston Houston, TX 77204

This watermark does not appear in the registered version - Laser- Tissue Interaction

Electromagnetic Modeling of the Human Eye for Wireless Environment

Ocular studies of EMF exposure at the MMW

EMF Energy Absorption Mechanisms in the mmw Frequency Range. Andreas Christ

EMF exposure of the skin at the mmw

ELECTROMAGNETIC ENVIRONMENT GENERATED IN A TEM CELL FOR BIOLOGICAL DOSIMETRY APPLICATIONS

Statistical Analysis of the Whole Body Specific Absorption Rate using Human Body Characteristics

TECHNO INDIA BATANAGAR

Calculation of Temperature Rises in the Human Eye Exposed to EM Waves in the ISM Frequency Bands

1 Electromagnetic concepts useful for radar applications

APPENDIX A RADIATION OVERVIEW

11/23/2014 RADIATION AND DOSE MEASUREMENTS. Units of Radioactivity

Plane Waves Part II. 1. For an electromagnetic wave incident from one medium to a second medium, total reflection takes place when

EMF PENETRATION IN BIOLOGICAL TISSUE WHEN EXPOSED IN THE NEAR FIELD OF A MOBILE PHONE ANTENNA

Non-Ionizing Radiation General Information

Friis Transmission Equation and Radar Range Equation 8.1 Friis Transmission Equation

Radiation Fundamentals. Radiation Safety Training Module 1

Electromagnetic-Thermal Analysis Study Based on HFSS-ANSYS Link

INTERACTION OF ELECTROMAGNETIC WAVE AND PLASMA SLAB WITH PARTIALLY LINEAR AND SINU- SOIDAL ELECTRON DENSITY PROFILE

UNIVERSITY OF BOLTON. SCHOOL OF ENGINEERING, SPORTS and SCIENCES BENG (HONS) ELECTRICAL & ELECTRONICS ENGINEERING EXAMINATION SEMESTER /2018

A Numerical Study on. Microwave Coagulation Therapy

SCIENCE & TECHNOLOGY

Doppler echocardiography & Magnetic Resonance Imaging. Doppler echocardiography. History: - Langevin developed sonar.

Name: COMBINED SCIENCE Topics 4, 5 & 6 LEARNING OUTCOMES. Maintain a record of your progress Use the booklet to guide revision

Radiation Safety Training Session 1: Radiation Protection Fundamentals and Biological Effects

Radiation Protection Fundamentals and Biological Effects: Session 1

Effects of Electromagnetic Fields On Living Organisms

Addition of a Lens Before the Second Focus of a Prolate-Spheroidal IRA

Plane Waves GATE Problems (Part I)

Georgia Institute of Technology. Radiation Detection & Protection (Day 3)

Technique for the electric and magnetic parameter measurement of powdered materials

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad Electronics and Communicaton Engineering

ERROR CONVERGENCE ANALYSIS FOR LOCAL HYPERTHERMIA APPLICATIONS

A MATLAB GUI FOR SIMULATING THE PROPAGATION OF THE ELECTROMAGNETIC FIELD IN A 2-D INFINITE SPACE

Ultrasound reflects strongly at different tissue layers inside the arm.

Sound wave bends as it hits an interface at an oblique angle. 4. Reflection. Sound wave bounces back to probe

Initial Certification

Medical Imaging Physics Spring Quarter Week 3-2

Shielding of Ionising Radiation with the Dosimetry & Shielding Module

Publication II Wiley Periodicals. Reprinted by permission of John Wiley & Sons.

Exposure Controls for physical Agents

Study on Evaluation of Induced Current within a Human Body by Electromagnetic Field of a Mobile Phone

Name Class Date. What two models do scientists use to describe light? What is the electromagnetic spectrum? How can electromagnetic waves be used?

Uniform Plane Waves. Ranga Rodrigo. University of Moratuwa. November 7, 2008

Radiofrequency Dosimetry in Subjects Implanted with Metallic Structures Undergoing MRI: a Numerical Study

Chapter 30 X Rays GOALS. When you have mastered the material in this chapter, you will be able to:

ECE 6340 Fall Homework 2. Please do the following problems (you may do the others for practice if you wish): Probs. 1, 2, 3, 4, 5, 6, 7, 10, 12

Radiological Preparedness & Emergency Response. Session II. Objectives. Basic Radiation Physics

FDTD analysis of human body-core temperature elevation. due to RF far-field energy prescribed in ICNIRP

X-ray Interaction with Matter

Basic System. Basic System. Sonosite 180. Acuson Sequoia. Echo occurs at t=2z/c where c is approximately 1500 m/s or 1.5 mm/µs

Loughborough University Institutional Repository. This item was submitted to Loughborough University's Institutional Repository by the/an author.

5 RCS Management of Edge Diffracted Waves

National 3 Waves and Radiation

WHAT IS IONIZING RADIATION

sample What happens when we are exposed to radiation? 1.1 Natural radiation Cosmic radiation

Supplementary Information for Metamaterial Absorber for Electromagnetic Waves in Periodic Water Droplets

A small object is placed a distance 2.0 cm from a thin convex lens. The focal length of the lens is 5.0 cm.

Radiometry. Energy & Power

Microwave Ablation and associated Dielectric Properties- Modelling, Measurements and Sensitivity Investigation

Gy can be used for any type of radiation. Gy does not describe the biological effects of the different radiations.

Electromagnetic Waves

Power Absorption of Near Field of Elementary Radiators in Proximity of a Composite Layer

Research Article Trapped-Mode Resonance Regime of Thin Microwave Electromagnetic Arrays with Two Concentric Rings in Unit Cell

BETTER DESIGN AND NEW TECHNOLOGIES IMPROVE LASER POWER MEASUREMENT INSTRUMENTATION

EECS 117. Lecture 22: Poynting s Theorem and Normal Incidence. Prof. Niknejad. University of California, Berkeley

Publication I Institute of Physics Publishing (IOPP) Reprinted by permission of Institute of Physics Publishing.

11 July 2018 GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELDS

Glint and Glare Analysis

Alternative approaches to electromagnetic cloaking and invisibility

LIGHT WAVES AND PARTICLES

Radiation Terminology

Physics (Theory) There are 30 questions in total. Question Nos. 1 to 8 are very short answer type questions and carry one mark each.

The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum

AQA Physics /7408

ELECTROMAGNETIC WAVES ELECTROMAGNETIC SPECTRUM

TM-Radiation From an Obliquely Flanged Parallel-Plate Waveguide

MINIMIZING REFLECTION AND FOCUSSING OF INCIDENT WAVE TO ENHANCE ENERGY DEPOSITION IN PHOTODETECTOR S ACTIVE REGION

Ba (Z = 56) W (Z = 74) preferred target Mo (Z = 42) Pb (Z = 82) Pd (Z = 64)

EL-GY 6813/BE-GY 6203 Medical Imaging, Fall 2016 Final Exam

Lecture 2 Review of Maxwell s Equations and the EM Constitutive Parameters

ECE357H1F ELECTROMAGNETIC FIELDS FINAL EXAM. 28 April Examiner: Prof. Sean V. Hum. Duration: hours

Shielding Effectiveness of Modern Energy Saving Windows

New GCSE 4463/01 SCIENCE A FOUNDATION TIER PHYSICS 1

EFFECTIVE SKIN DEPTH FOR MULTILAYER COATED CONDUCTOR

ULTRASOUND. Ultrasound physical phenomenon properties basics of medical applications, History. History

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING QUESTION BANK

PHYSICS A 2825/02 Health Physics

ELECTROMAGNETIC MODELING OF VIRTUAL HUMANS TO DETERMINE HEART CURRENT FACTORS

05/11/2013. Nuclear Fuel Cycle Ionizing radiation. Typical decay energies. Radiation with energy > 100 ev. Ionize an atom < 15eV

RADIATION and the EM Spectrum

TWINS II ANNA ŠUŠNJARA, VICKO DORIĆ & DRAGAN POLJAK

Technical University of Denmark

3D ELECTROMAGNETIC FIELD SIMULATION OF SILICON CARBIDE AND GRAPHITE PLATE IN MICROWAVE OVEN

Aperture Antennas 1 Introduction

Transcription:

EC3630 Radiowave Propagation ELECTROMAGNETIC RADIATION HAZARDS by Professor David Jenn (version 1.1) 1

Electromagnetic Radiation Hazards (1) Electromagnetic energy is absorbed by the body and deposits energy internally leading to thermal loads and temperature gradients. Since the 1950s the informally accepted tolerance dose in the US has been 10 mw/cm 2. The American National Standards Institute (ANSI) officially adopted 10 mw/cm 2 as the standard in 1966 for a five year term, and it was reaffirmed again in 1969 and 1974. It was concluded at the time that power densities in excess of 100 mw/cm 2 were needed to produce any significant biological changes. Power Density, mw/sqcm 100 80 60 40 Squirrel Monkey Rhesus Monkey Man Power density needed for 1 C temperature increase at 2.45 GHz and 60 minutes. Rat 20 10-1 10 0 Body Weight, kg 10 1 10 2 2

Electromagnetic Radiation Hazards (2) Later studies revealed that certain body organs were more susceptible to the effects of electromagnetic heating than others. The testis power density safety curve assumes damage when the temperature increases by on 1.4 degrees C (which is less than a warm bath). Power density, mw/sqcm 10 3 10 2 10 1 1 min. 1 hr EYES WHOLE BODY TESTIS 10 0 10 0 10 1 10 2 10 3 10 4 10 5 Time, seconds Effects other than those due to heating have been alleged: changes in hormone levels, blood chemistry, neurological function, growth, etc. The vast majority of studies have been negative. Research on the effect of EM radiation on the immune system has been inconclusive. Threshold levels versus time for sensitive organs. 3

Electromagnetic Radiation Hazards (3) The specific absorption rate (SAR) is used in dosimetric applications 2 SAR = σ E / ρ W/kg where ρ is the mass per volume (kg/m 3 ). SAR is the time rate at which electromagnetic energy is imparted to an element of mass of a biological body. A linear rise in temperature T can be converted to a SAR value by the formula SAR = T / t where c p is the specific heat of the material (J/kg- o C) and t is the duration 1. It was also found that the body has a resonance when the height (head-to-toe length) is approximately 0.4λ and the electric field is parallel to the body axis. This occurs around 70 MHz for the standard man (175 cm). Absorption can increase by a factor of seven at resonance. c p 1 For water 1 cal/gm c p = C, 3 ρ = 1000 kg/m at 1 atmosphere and 0 C, and 1 cal = 4.18606 J. 4

Electromagnetic Radiation Hazards (4) Summary of current ANSI standards for exposure to non-ionizing radiation 10 5 (a) 10 2 (b) 10 2 (c) 10 3 (d) Power density, mw/sqcm 10 4 10 3 Whole Body Average SAR, W/kg 10 1 10 0 10-1 10-2 Maximum SAR, W/kg 10 1 10 0 Maximum E, V/m 10 2 10 1 10 2 10 0 10 2 Frequency, MHz 10 4 10-3 10 0 10 2 Frequency, MHz 10 4 10-1 10 0 10 2 Frequency, MHz 10 4 10 0 10 0 10 2 Frequency, MHz 10 4 Data has shown that a whole-body averaged SAR of 4 W/kg is acceptable, and subsequently the standard was set at 0.4 W/kg to incorporate an order of magnitude safety factor. The standard allows the spatial peak SAR to be greater than the whole-body averaged SAR by a factor of 20. Essentially this allows relaxation of the power density limits for partial body exposure. The maximum permissible exposure (MPE) in the 1 to 3 GHz range is based on a 6 minute averaging time. 5

Electromagnetic Radiation Hazards (5) The safety issue has four aspects: 1) The whole-body averaged SAR should be less than the safe level (4 W/kg) The whole-body averaged SAR is computed taking the average power absorbed by the body over a 6 minute interval and dividing by the total body weight. 2) The maximum partial-body SAR should be less than 20 times the whole-body averaged SAR (80 W/kg) Partial-body SAR is permitted to be up to 20 times larger than the whole-body averaged SAR. It is determined by averaging over a volume ( V a ) exposed to the strongest incident power density. The appropriate averaging volume is still the subject of discussion. Cubes of 1 cm 3, 10 cm 3, and 100 cm 3 have been suggested. 3) The power density versus exposure time should remain below the safe values for sensitive organs such as the eyes and testes. The traditional safety standard of 10 mw/cm 2 applies to an indefinite time of exposure. It has been recognized that much higher levels are tolerable over short time periods. The most sensitive organ is the testes and the curve shown previously is based on the time and power density to reach 37 C, which is considered potentially dangerous. However this temperature is exceeded in a common hot bath and thermal induced damage is generally reversible. Irreversible injury to the human eye can occur when the exposure reaches several hundred mw/cm 2 and there are multiple exposures of several minutes in duration. Extended exposures in excess of 10 mw/cm 2 but less than 300 mw/cm 2 can cause reversible injuries. 4) The incident power density must be low enough to avoid a shock or burn hazard. Current induced in the body can potentially lead to shock if contact is made with a conducting object. 6

Electromagnetic Radiation Hazards (6) The depth of penetration into and subsequent absorption of a wave by the body are determined by the relative dielectric constant ( ε r ) and conductivity (σ ) of the body tissues. These are shown as a function of frequency. The absorption of energy is determined by the attenuation constant, α. REL DIEL CONST 150 100 CONDUCTIVITY, S/m 50 0 10 1 10 2 10 3 10 4 FREQUENCY, MHz 6 4 2 o = MUSCLE, x = FAT o = MUSCLE, x = FAT 0 10 1 10 2 10 3 10 4 FREQUENCY, MHz 7

Electromagnetic Radiation Hazards (7) Because the body is a good conductor, the skin depth is δ 1/ α. The relatively large εr and σ of the body results in a significant reflection of the incident wave at the body/air boundary. 10 2 Skin depth of body materials FAT, BONE (LOW WATER CONTENT) Reflection of a plane wave from the body 70 60 Skin Depth (δ ), cm 10 1 10 0 MUSCLE, SKIN, INTERNAL ORGANS (HIGH WATER CONTENT) o o o o o o (1 Γ 2 ) 100 50 40 30 20 10-1 10 1 10 2 10 3 10 4 Frequency, MHz 10 MHz 10 1 10 2 10 3 Frequency, 10 4 10 5 8

Electromagnetic Radiation Hazards (8) Historical note on the industrial, scientific, and measurement (ISM) band (2.45 GHz): The small skin depth at 2.45 GHz implies that the energy transfer between the wave and body occurs near the surface, and at these shallow depths the heat exchange mechanisms of the body are effective. Note that this is not a good frequency range for dosimetric (medical) applications because it is difficult to deposit energy deep into the body. The choice of the 2.45 GHz frequency for medical use was based on the erroneous conclusions of data collected by MIT in 1946. The study found that the absorption of water was 7000 times greater at this frequency than at the previously used 27 MHz and it was assumed that the therapeutic heating value would be much greater. Thus 2.45 GHz was adopted as a medical frequency before it was realized that the geometry and electrical properties of the body invalidated the study conclusion. See A. Guy, History of Biological Effects and Medical Applications of Microwave Energy, IEEE Transactions on Microwave Theory and Techniques, vol. 32, no. 9. September 1984. 9

Electromagnetic Radiation Hazards (9) Various models are used in EM radiation and safety calculations. The simplest are spherical and monolithic models of a man. In general these dummy models are called phantoms. d HEAD BACK h FRONT FEET w Complex phantom for use with the finite integration technique (CST Microwave Studio) The monolithic model is a rectangular parallelepiped 10

Electromagnetic Radiation Hazards (10) A sample calculation of whole body SAR for the monolithic model follows. Dimensions: height (toe to head), h=1.75 m; width, (across shoulders) w=0.45 m; depth (chest to back), d=0.25 m (volume is 0.1969 m3). A height of 175 cm is the standard man. The densities of fat and muscle are approximately 0.9 g/cm3 and 1.1 g/cm3, respectively. For convenience it is assumed that the average density of all body tissues is 1.0 g/cm3 yielding a mass of about 92 kg for the given dimensions. For absorption calculations the following tissue parameters are used. Tissue σ (S/m) εr muscle (high water content) 46 2.3 fat (low water content) 5.5 0.15 11

Electromagnetic Radiation Hazards (11) The body is illuminated by an antenna with principal plane beamwidths range R the area of the spot is an ellipse with axes l x = Rθ and l = Rθ x y θ and y x θ y. At. When the spot is larger than the body frontal area, the frontal area is used as the illuminated area; if the spot is smaller than the frontal area, the spot size determines the illuminated area. Therefore the illuminated area of the monolithic body is approximately A illum πab = where a = min( l x, w) and b = min( l y, h) 4 TRANSMIT ANTENNA APERTURE y x BEAM SPOT l y MONOLITHIC MAN l x L y L x MAINBEAM R 12

Electromagnetic Radiation Hazards (12) For example, let the aperture dimensions be Lx = 20m and L = 2m. Referring to the y figure, the spot size at 50 m is greater than the body frontal area below about 1.9 GHz. Above 1.9 GHz the antenna beam narrows with frequency and less of the body is illuminated. The worst case whole body SAR occurs when the spot size is bigger than the body. ILLUMINATED BODY AREA, m 2 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 TRANSMIT ANTENNA: Lx=20 m, Ly=2 m R=30 m R=50 m 0.1 1 1.5 2 2.5 3 FREQUENCY, MHz 13

Electromagnetic Radiation Hazards (13) For this calculation it is assumed that all of the incident field that is not reflected is absorbed P a = W wh(1 Γ i The reflection coefficient Γ is computed for a homogeneous slab of material (plot shown on p. 8) η Γ = η i i 377, + 377 η i 377 η tanh( γd ) =, η 377tanh( γd ) η = 2 ) σ + jωµ jωε r ε o, γ = α + η i is the intrinsic impedance of the body of thickness d with free space on the back side. The incident power density, assuming the body is in the far field of the antenna, is W i = P G t t /(4πR The gain of the antenna with efficiency e is approximately related to the beamwidth by 2 ) jβ G = 4π el x L y / λ 2 4π e /( θ x θ y ) 14

Electromagnetic Radiation Hazards (14) For this example, another simplifying assumption is that the field in the body is approximately constant within the first skin depth and zero elsewhere. Thus all of the power is absorbed in the first skin depth E of the body. Sample values: P = 100 W, f =1 GHz, t 2 = δ = 0.023 m, 1 Γ 0. 4 (from charts on p. 8), R =60 m and e = 0.7 The incident power density is Front δ ~ e αz 2 (100)(20)(2)(0.7) Wi = Pt LxLye /( λ R) = = 8.64 W/m 2 = 0.864 mw/cm 2 2 2 (0.3) (60) d Back z which is safe (< 10 mw/cm 2 ). For the present case, we use a SAR averaging volume of V a = whδ = 0.0101 m. 3 15

Electromagnetic Radiation Hazards (15) The heated body mass is 3 3 ( 100cm) kg 3 ρv a = ρwhδ = 1 gm /cm ( 0.0101 m ) = 10. 1 3 m 1000 gm kg and the SAR SAR = Pa ρv a W (1 Γ = iwh ρv which is below the safe level of 0.4 W/kg. The SAR for 1 mw/cm2 incident power density is shown at three frequencies and compared to data for other more detailed phantom models 1. a 2 ) = (0.864)(0.25)(1.74)(0.4) 10.1 = 0.1497 W/kg 1 O. Gandhi, State of the Knowledge for EM Absorbed Dose in Man and Animals, Proceedings of 10 the IEEE, vol. 68, January 1980. -3 10 1 10 2 10 3 10 4 Whole Body Averaged SAR, W/kg 10 0 10-1 10-2 AVERAGE OF: BLOCK MODEL HOMOGENEOUS SPHERE LAYERED SPHEROID EXPERIMENTAL DATA Frequency, MHz. MONOLITHIC MODEL... 16