Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Similar documents
Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Comprehensive 2D-LC Analysis of Chinese Herbal Medicine

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

Analysis of Beer by Comprehensive 2D-LC with the Agilent 1290 Infinity 2D-LC system

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Application Note. Authors. Abstract. Food Testing & Agriculture. Stephen E. Reichenbach University of Nebraska Lincoln, NE, USA

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

Determination of Enantiomeric Excess of Metolachlor from Chiral Synthesis using the Agilent 1260 Infinity Analytical SFC System

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

The Agilent 1290 Infinity II Multi Method Solution

Application Note. Authors. Abstract. Energy & Chemicals, Biofuels & Alternative Energy

Method Development in Comprehensive 2D-LC Finding the Most Orthogonal Separation Systems for RPLC RPLC Using Column and Solvent Screening

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Analysis of E.coli Tryptic Digest and Intact Protein Using the Agilent 1290 Infinity 2D-LC Solution with Diode Array Detection and Q-TOF LC/MS

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Application Note. Agilent Application Solution Analysis of acaricides in honey. Authors. Abstract. Food

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Detection of Trace Level Pharmaceuticals in Drinking Water by Online SPE Enrichment with the Agilent 1200 Infinity Series Online-SPE Solution

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Application Note. Abstract. Authors. Pharmaceutical. William J. Long Agilent Technologies, Inc Centerville Road Wilmington, DE USA

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Impact of Instrument Dispersion on Performance of HPLC Capillary Columns

Application Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection.

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Agilent LC & LC-MS Cannabis Testing

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

High Speed 2D-HPLC Through the Use of Ultra-Fast High Temperature HPLC as the Second Dimension

Two Dimensional LC with Diode-Array- Detection & Quadrupole Time-of-Flight Detection

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Modernizing the USP Monograph for Acetaminophen

Varian Galaxie Chromatography Data System for Preparative HPLC

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Analysis of Positional Isomers with Agilent Poroshell 120 PFP Columns

COMPREHENSIVE LC X LC ANALYSIS OF FLAVORING INGREDIENTS IN DISTILLED SPIRITS

Use of the SFC-MS Splitter Kit G

Analysis of E.coli Tryptic Digest and Intact Protein Using the Agilent 1290 Infinity 2D-LC Solution with Diode Array Detection and Q-TOF LC/MS

Routine MS Detection for USP Chromatographic Methods

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Fast Screening Methods for Analgesics and Non-Steroidal Anti-Inflammatory Drugs by HPLC

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

The new Agilent 1290 Infinity Quaternary LC

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Application Note. Edgar Naegele. Abstract

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions

AM23 - Texas A&M University Health Science Purchase Order

UPLC Intact MASS Analysis Application Kit

Fast Screening Methods for Beta Blockers by HPLC with Agilent Poroshell 120 Columns

Analysis of Saponins in Spine Date Seed using Agilent ZORBAX Solvent Saver HT (1.8 µm) Columns

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software. Application

High Resolution Fast LC

Fast methods for the determination of ibuprofen in drug products

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Chromatography. Gas Chromatography

How proteins separate on reverse-phase HPLC

Rapid quantification of Chinese medicine Zuo Jin Pill using rapid resolution liquid chromatography

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Kinetic Optimization of Speed and Efficiency in Fast Ultra-High Resolution HPLC

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Transcription:

Automated Switching Between D-LC and Comprehensive D-LC Analysis The Agilent 90 Infinity D-LC Solution Technical Overview Author Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany Abstract This Technical Overview shows a flexible setup of the Agilent 90 Infinity D-LC Solution that allows switching between D-LC and comprehensive D-LC analysis with a few mouse clicks, and without any hardware change. This is accomplished by the installation of an additional -position/-port valve. Using the determination of phenolic compounds in virgin olive oil as an example, it was shown that the additional -position/-port valve does not have any negative impact on the separation, neither for D-LC analysis, nor for comprehensive D-LC analysis. Verified for Agilent 90 Infinity II LC

Introduction One dimensional liquid chromatography (D-LC) is routinely applied to the analysis of all kinds of samples in different fields. However, it does not provide enough resolving power, or peak capacity, to resolve all components of complex samples. Comprehensive two-dimensional liquid chromatography (comprehensive D-LC, LCxLC) can be employed to greatly increase the peak capacity compared to D-LC methods. In LCxLC, the entire sample is subjected to separation in two dimensions. This is accomplished by alternately collecting the effluent from the first dimension column in two loop capillaries and injecting the collected effluent onto the second dimension column. When an orthogonal column configuration with noncorrelated separation mechanisms in the first and second dimension is used, the total peak capacity equals the product of the first and second dimension peak capacities,. In most implementations of LCxLC, some degree of correlation exists between the first and second dimension separation mechanisms, especially if two reversed phase separations are combined (RPxRP). In this case, only part of the available two-dimensional separation space is used, and the peaks are distributed, for example, inside of a triangular sector within the available separation space. This reduces the resulting peak capacity. The accessible two-dimensional separation space can be enlarged by designing complex gradients for the second dimension separation, thereby increasing peak capacity. Usually, it is necessary to reconnect capillaries to switch between performing D-LC methods and comprehensive D-LC methods using the same LC system. This Technical Overview shows the setup of the Agilent 90 Infinity D-LC Solution using an additional -position/-port valve to allow switching between D-LC and comprehensive D-LC analysis with a few mouse clicks, and without any hardware change. Experimental Equipment The Agilent 90 Infinity D-LC Solution was comprised of the following modules: Two Agilent 90 Infinity Binary Pumps (G0A) Agilent 90 Infinity (GA) with 90 Infinity Thermostat (G0B) Agilent 90 Infinity Thermostatted Column Compartment (GC) with -position/-port ultra high pressure valve head,,00 bar (p/n 07-7) Agilent 90 Infinity Valve Drive (G70A) with -position/ port duo valve (D LC Valve Head,,00 bar p/n 07-) equipped with two 0-µL loops Agilent 90 Infinity Diode Array Detector (GA) with a 0 mm Max-Light Cartridge Cell (G 0007) Software Agilent OpenLAB CDS ChemStation Edition Rev. C.0.0 [8] with 90 Infinity D-LC Acquisition Software Product Version A.0.0 []. GC Image LCxLC Edition Software for D-LC data analysis from GC Image LLC., Lincoln, NE, USA. Chemicals All solvents were LC grade. Acetonitrile and methanol were purchased from Merck, Darmstadt, Germany. Fresh ultrapure water was obtained from a Milli-Q Integral system equipped with a 0.-μm membrane point-of-use cartridge (Millipak, EMD Millipore, Billerica, MA, USA). Formic acid was purchased from Sigma-Aldrich, Steinheim, Germany. Sample Olive oil was purchased directly from an Italian olive oil farm, and sample preparation was carried out according to the protocol from the International Olive Council (COI/T.0/Doc No 9, November 009).

Setup To allow switching between D-LC and comprehensive D-LC analysis without any hardware change, an additional -position/-port valve was included in the setup of the Agilent 90 Infinity D-LC Solution. During comprehensive D-LC analysis, a -position/-port-duo valve was used for modulation, as shown in a previous Technical Overview. The setup of the system and the plumbing of the -position/-port valve, as well as the -position/-port-duo valve are shown in Figures and. In Figure, showing D LC analysis, the -position/ port valve is set to connect ports and, directing the effluent from the first dimension column to the detector. The -position/ port duo valve does not switch during D-LC analysis, and the flow rate of the second dimension pump can be set to 0 ml/min. Alternatively, the second dimension column can be flushed during D-LC analysis. In Figure, showing comprehensive D LC analysis, the -position/ port valve is set to connect ports and, directing the effluent from the first dimension column to the -position/-port-duo valve. Using the -position/-port-duo valve, the effluent from the first dimension column is alternately collected in two loops and injected onto the second dimension column. The -position/-port valve used to switch between D-LC and comprehensive D-LC analysis was installed in the Agilent 90 Infinity Thermostatted Column Compartment, and the -position/-port-duo valve used for modulation was operated by an Agilent 90 Infinity Valve Drive. ¹D-Pump Waste Detector ¹D-Column 8 ²D-Pump 7 ²D-Column Figure. Setup of the Agilent 90 Infinity D-LC Solution with an additional -position/-port valve positioned for D-LC analysis. A ¹D-Pump Detector ¹D-Column 8 Fill-direction Analyze-direction B ¹D-Pump Fill-direction Analyze-direction Waste ¹D-Column 8 ²D-Column ²D-Pump 7 ²D-Column Detector Fill-direction Analyze-direction Waste 7 ²D-Pump Fill-direction Analyze-direction Figure. Setup of the Agilent 90 Infinity D-LC Solution with an additional -position/-port valve positioned for comprehensive D-LC analysis; (A) Collection of the effluent from the first dimension column in loop (between ports and 8); (B) Collection of the effluent from the first dimension column in loop (between ports and ), analysis of the content of loop on the second dimension column.

To switch between D-LC and comprehensive D-LC analysis, respective methods with the appropriate setting of the -position/-port valve have to be defined. In the instrument configuration, D-LC has to be disabled for D-LC analysis and enabled for comprehensive D-LC analysis. This can be done with one mouse click, as shown in Figure. Check for comprehensive D-LC analysis, uncheck for D-LC analysis Figure. Enabling and disabling of D-LC in the instrument configuration. D-LC method Column Agilent ZORBAX RRHD Eclipse Plus Phenyl-Hexyl,. 0 mm,.8 µm (p/n 9979-9) -position/-port valve The -position/-port valve was set to connect ports and to direct the effluent from the column to the detector (Figure ). Pump Solvent A Water + 0. % formic acid Solvent B Methanol + 0. % formic acid Flow rate 0. ml/min Gradient 0 minutes % B minutes 9 % B 0 minutes 9 % B Stop time 0 minutes Post time 8 minutes Thermostatted Column Compartment Column temperature Maintained at C Injection volume µl Sample temperature C Needle wash Diode Array Detector Wavelength Data rate seconds in methanol 0 nm/ nm, Ref.: 0 nm/00 nm 0 Hz

Comprehensive D-LC method Columns First dimension Agilent ZORBAX RRHD Eclipse Plus Phenyl-Hexyl,. 0 mm,.8 µm (p/n 9979-9) Second dimension Agilent ZORBAX RRHD Eclipse Plus C8,.0 0 mm,.8 µm (p/n 9977-0) -position/-port valve The -position/-port valve was set to connect ports and to direct the effluent from the first dimension column to the -position/-port-duo valve (Figure ). First dimension pump Solvent A Solvent B Flow rate Gradient Stop time Water + 0. % formic acid Methanol + 0. % formic acid 0.0 ml/min 0 minutes % B 0 minutes 9 % B 80 minutes 9 % B 80 minutes Post time 0 minutes Second dimension pump Solvent A Solvent B Flow rate Gradient Gradient modulation Water + 0. % formic acid Acetonitrile + 0. % formic acid ml/min 0.00 minutes % B 0. minutes % B 0. minutes % B 0.0 minutes % B Post time 0 minutes Thermostatted Column Compartment 0.00 min % B to minutes % B to 0 minutes % B to minutes % B 0. minutes % B to minutes % B to 0 minutes 0 % B to minutes 9 % B 0. minutes % B to minutes % B to 0 minutes % B to minutes % B 0.0 minutes % B to minutes % B to 0 minutes % B to minutes % B First dimension column on the right side at C Second dimension column on the left side at 0 C -position/-port-duo valve The -position/-port-duo valve was switched automatically after each second dimension modulation cycle of 0 seconds. The loops were used in a cocurrent manner (filled and eluted from the same side). Injection volume 0 µl Sample temperature C Needle wash Diode Array Detector Wavelength Data rate seconds in methanol 0 nm/ nm, Ref.: 0 nm/00 nm 80 Hz

The method setup for the second dimension pump with the complex gradient designed to enlarge the accessible two-dimensional separation space is shown in Figure. Results and Discussion This Technical Overview shows the setup of the Agilent 90 Infinity D LC Solution using an additional -position/ port valve to allow switching between D-LC and comprehensive D-LC analysis. In D LC analysis, the additional -position/ port valve is installed in the flow path behind the column. In comprehensive D-LC analysis, respectively, the valve is installed behind the first dimension column as well as the second dimension column. To demonstrate the performance of this setup, it is shown that the additional -position/-port valve does not have any negative impact on the separation, neither for D-LC analysis, nor for comprehensive D-LC analysis. The determination of phenolic compounds in virgin olive oil using comprehensive D-LC shown in a previous Application Note was chosen to demonstrate the performance of the setup. For comprehensive D-LC analysis, the method described in that Application Note was used. For D-LC analysis, the flow rate and gradient time for the (first dimension) column were changed to typical values used in D-LC analysis. Both the D-LC analysis and the comprehensive D-LC analysis, were performed using an exemplary olive oil with the additional -position/-port valve in the flow path, and without this valve for comparison. Figure shows an overlay of six D-LC analyses of the exemplary olive oil, three analyses performed with the additional -position/-port valve in the flow path and three analyses performed without this valve. No difference between the analyses performed with and without the additional -position/-port valve in the flow path can be observed. Figure. Method setup for the second dimension pump. mau 0 0 00 80 0 0 0 0..0 7. 0.0..0 7. Figure. Overlay of six D-LC analyses of an olive oil, three analyses performed with the additional -position/-port valve in the flow path and three analyses performed without this valve. min

Figure shows two comprehensive D-LC analyses of the exemplary olive oil. One analysis was done with the additional -position/-port valve in the flow path (Figure A) and one analysis was done without this valve (Figure B). As observed for D-LC analysis, no impact of the additional -position/-port valve can be seen during comprehensive D-LC analysis. The only difference between the two comprehensive D-LC analyses shown in Figure is the reduced second dimension retention time of peaks eluting in the first dimension retention time range from 0 to minutes, in Figure B (for example, see highlighted peak). This can be explained by the fact that these peaks were detected one modulation cycle later in Figure B compared to Figure A. The rapid modulation of the second dimension gradient in the time range from 0 to minutes causes the observed retention time differences. Conclusion This Technical Overview shows the setup of the Agilent 90 Infinity D LC Solution comprising an additional -position/ port valve to allow switching between D-LC and comprehensive D-LC analysis with a few mouse clicks, and without any hardware change. Using the determination of phenolic compounds in virgin olive oil, it is shown that the additional -position/-port valve has no negative impact on the separation, neither for D-LC analysis, nor for comprehensive D-LC analysis. Therefore, the additional -position/-port valve allows a flexible setup of the Agilent 90 Infinity D-LC Solution for D-LC and comprehensive D-LC analysis. A B Figure. Comprehensive D-LC analysis of an olive oil; A) performed with the additional -position/ port valve in the flow path; B) performed without the additional -position/-port valve. 7

References. Dugo, et al. Comprehensive multidimensional liquid chromatography: theory and applications. J. Chromatogr. A 008, 8, pp -8.. Giddings. Two-dimensional separations: concept and promise. Analytical Chemistry 98,, 8A-0A, A, A passim.. Duck, et al. A simple method for the determination of peak distribution in comprehensive two-dimensional liquid chromatography. J. of Chromatography A 0,, pp 9-7.. International Olive Council: COI/T.0/ DOC. 9-009. Determination of biophenols in olive oils by HPLC, 009.. Naegele, E. Performance evaluation of the Agilent 90 Infinity D LC Solution for comprehensive two dimensional liquid chromatography, Agilent Technologies Technical Overview, publication number 99-08EN, 0.. Krieger, S., Schneider, S. Quality Analysis of Extra Virgin Olive Oils - Part 7, Agilent Technologies Application Note, publication number 99-EN, 0. www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc., 0 Published in the USA, September, 0 99-8EN