Introducing 7820A GC System. Reliability, Simplicity & Affordability!

Similar documents
Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Analytical Instrumentation

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Author. Abstract. Introduction

Agilent Intuvo 9000 Gas Chromatograph System

Understanding Gas Chromatography

Application. Gas Chromatography February Introduction

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

GAS CHROMATOGRAPHY (GC)

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Selection of a Capillary GC Column

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Introduction to Capillary GC

Automated Characterization of Compounds in Fire Debris Samples

Maximizing Sample Throughput In Purge And Trap Analysis

USP<467> residual solvents

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Headspace Technology for GC and GC/MS: Features, benefits & applications

Agilent 5977A Series GC/MSD System

Introduction to Gas Chromatography

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Routine-grade performance of a new static headspace autosampler for the analysis of residual solvents according to USP <467> method

STANDARD OPERATING PROCEDURES

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

Study of Residual Solvents in Various Matrices by Static Headspace

Title Experiment 7: Gas Chromatography and Mass Spectrometry: Fuel Analysis

Organochlorine Pesticides by GCxGC-ECD

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

high performance OPTIC 3 and applications a total analytical solution

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

Agilent G2350A Atomic Emission Detector (AED)

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Practical Fast Gas Chromatography for Contract Laboratory Program Pesticide Analyses *

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

Thermo Scientific TriPlus RSH Autosampler Integrated Sampling System. You are productive solving your chromatography challenges

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Selection of a Capillary

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

Residual solvents analysis using an Agilent Intuvo 9000 GC system

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

Petrochemical. Transformer Oil Gas Analysis - TOGA

Secrets of GC Column Dimensions

883 Basic IC plus. The smallest Metrohm ion chromatograph

Analysis of BTEX in Natural Water with SPME

ION CHROMATOGRAPHY SYSTEM S 150

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Multi-residue analysis of pesticides by GC-HRMS

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

Application Note. Abstract. Authors. Introduction

Application. Gas Chromatography March 1998

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010

MultiVap8: Automated concentration system

Perseverance. Experimentation. Knowledge.

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Ultra-Inert chemistry for Trace Level Analysis

TDTS 16 Round-the-clock, on-line and cryogen-free monitoring of hydrocarbons from acetylene to trimethylbenzene in ambient air

Trajan SGE GC Columns

Varian Galaxie Chromatography Data System for Preparative HPLC

Introduction to Capillary GC

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

TOXICOLOGY & FORENSIC APPLICATIONS

Luminescence transitions. Fluorescence spectroscopy

Uncontrolled Copy. SOP-060 Chromatography, Tune Evaluation and Troubleshooting. Table of Contents. 1. Principle... 3

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Making Improvements to Today s Natural Gas Analysis Systems

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

110 Lowell Rd Hudson, NH USA Tel:

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Fusion UV/Persulfate TOC Analyzer

Transcription:

Reliability, Simplicity & Affordability!

7820A GC System Key Features New 7693A ALS with 16 vial capacity Detectors include Full EPC from inlets to detectors ECD, NPD, TCD, and FID. Large oven for dual column operation Ezchrom Elite Compact Software Control New generation architecture for proven reliability/quality Simplified display and keys Page 2 March 2009

Who are the Target Customers? Typical 7820A customers can be found across all industries: Budget limited Routine testing typically with local (non international) methods (QA/QC) Not a high throughput lab Generally small to medium size organizations Government testing labs at local district level Need basic GC functionality with just good enough performance Page 3

7820A GC System Overall Features TCD FID Cap Split/splitless Purge Packed ECD Inlet w/epc Detector w/epc Valve Control and data handling Flexible configuration, two channels system 7820A GC system Installation, Familiarization Service Self installation Analog output Column and consumables LAN Consumables Kits 1 Checkout Column Technical support Page 4 NPD EZChrom Elite Compact Software Keypad

7820A Highlighted Features Full EPC Control from Inlet to Detector New ALS with 16 Sample Vials Intuitive and Innovative User Interface Powerful and Escalable EzChrom Compact Software Agilent Quality 7820A Consumable Kits with Excellent Value

Agilent 7820A GC Highlighted Feature All GC gas flows electronically controlled Older Manual Pneumatic System Page 6

EPC Benefits Ease of use No need for bubble meter and stop watch for setting gas flows. For switching between methods, the gas flows are saved with the method. This includes inlets and detectors. Better Quality Data EPC technology allows better retention time and peak area repeatability from run to run. Page 7

Agilent 7820A GC Highlighted Feature New 16 vial Automatic Liquid Sampler Benefits More accurate result over manual injections Automation; possible to have sample analyzed overnight without adding night shift Less training for new operators Page 8

Agilent 7820A GC Highlighted Feature Specially designed GC user interface Benefits 7820 s user interface has been simplified, minimizing the chance of operator error. Complex keypad has been reduced to 5 buttons. 7820 s display shows instrument s status in English or Chinese Temperature zones, flows, pressures, signals, run times 7820 indicator lights show the instrument s working status: running, error, not ready; Page 9

7820A GC User Interface Five key Interface Software keypad Page 10

Software Keypad Same functions as a GC keypad Displays GC actual and setpoint Necessary for GC method creation and control when customer uses integrator or 3rd party data processing software. Page 11

7820A Ease of use Dedicatedly designed user interface with only five keys which are most used, minimized operation error. Easy to learn, easy to use. Technician level customer could use software or software keypad to control instrument, set up methods and conduct daily maintenance. Operating level customer could reply on the easy to use simplified instrument user interface to conduction daily operation.

Power and Scalable Instrument Control and Data Handling System

EZChrom Elite Compact Software A low cost subset of EZChrom Elite Workstation Optional with 7820 GC Hardware Localized for Chinese and Japanese Markets Supports 2 7820A GC systems or a 7820A GC and a 1120 HPLC Compliance functionality available as an option Upgradable to EZChrom Elite Workstation Page 14

EZChrom Elite Compact Software Configuration Controls up to Two instruments per workstation (1120 LC or 7820 GC) Page 15

EZChrom Elite Compact Scalability Scalable member of the Lab Informatics Portfolio Upgradable as your lab grows. Your data methods and reports are all readable across all members of the product line Same user interface no re training needed Page 16

EZChrom Elite Compact Software View Instrument Status, current data and Run Queue on a single screen Auto increment of sample ID and Autosampler Vial Number Reports generated automatically Page 17

Standard Reports in EZChrom Elite Compact Predefined Reports in one mouse click Use Pre installed reports or add your own Ease of Use Page 18

Agilent Quality

Quality Programs and Certifications Typical Agilent GCs go through 3,600 hours of quality testing and 26,000 hours of life testing during development. These products must pass over 150 quality production inspections and 58 rigorous safety tests. These tests cover electrical, fire mechanical, chemical, fluid pressure, acoustic, and explosive hazards. Page 20

Agilent quality Build in design 7820 GC passed 58 rigorous quality tests that cover electrical, fire, mechanical, chemical, fluid pressure, and explosive hazards 50g shock test Explosion test

Agilent quality Build in design Radiated Emission Package Test Vibration Test Temperature and Humidity Test

Agilent quality Control process ensure that 7820 works and keeps working 7820 GC pass over 150 quality production inspections. And they are shipped with a specially designed checkout sample so performance can be verified after installation Continuous process improvement and advanced quality tools are used in production, such as Six sigma, Lean. 23 2009 6 25

Agilent Ensures of Value and Quality Instruments designed and built for long life Fully staffed quality engineers and furnished testing labs at four sites International standards and certifications Design for reliability, and supportability There is extensive support Number of service engineers and depth of training Web resources Applications chemists Local and internet seminars Breadth of services 10 year value promise Factors not reflected in specifications! Page 24

Excellent Value of 7820A Consumables Kits 5 different kits! Optimized to increase 7820A GC s performance and to reduce maintenance downtime. 30% discount over list price Page 25

Agilent 7820 GC, your easy choice Full EPC from Inlet to Detector New ALS with 16 Sample Vials Intuitive and Innovative User Interface Powerful and Escalable EzChrom Compact Software Agilent Quality ensures 7820A Consumable Kits with Excellent Value

7820 Application By Wang Chunxiao & Liu Wenmin

Application Aromatic Solvent Purity Analysis Organochlorine pesticides in drinking water analysis Page 28

Application Highlights HPI Aromatic solvent purity analysis An easy to use, single column method for aromatic solvent purity analysis that meets the requirements of ten separate ASTM methods EPC control and automatic injection ensures excellent repeatability for Retention time & peak area. FID s wide dynamic range enables a quantitative analysis of samples containing both very high & low concentrations in a single run Page 29

Unified of Aromatic Solvent Analysis 1 heptane 2 cyclohexane 3 octane 4 nonane 5 bezene 6 decane 7 toluene 8 undecane 9 ethylbenzene 10 p xylene 11 m xylene 12 cumene 13 dodecane 14 o xylene 15 propybenzene 16 p ethyltoluene 17 m ethyltoluene 18 t butylbenzene 19 s butybenzene 20 styene 21 tridecane 22 diethylbenzene 23 n butylbenzene 24 a methylstyrene 25 phenyacetylene pa Separation of 25 compounds analyzed by the ten ASTM aromatics methods listed Sample size: 0.5uL, Split ratio: 100:1 Oven temperature program:75 C (10 min); 3 C/min to 100 C, 10 C/min to 145 C Chromatographic overlay of 11 runs shows outstanding repeatability Min Page 30

Trace Impurities in Benzene Analysis >99% benzene is still visible without exceeding the instrumental dynamic range if drawn to full scale Sample size: 0.5uL, Split ratio:30:1 Oven temperature program: 75 C (10 min); 3 C/min to 100 C Quantitative analysis of samples containing both very high and very low concentrations in a single run Page 31

Trace Impurities in Benzene Analysis RSD% Cyclohexane Nonane Bezene Toluene 1,4-dioxane Ethylbenzene Peak Area Mean 430588.36 861794.27 900519436 590497.3 56348.45 688515.09 %RSD 1.59 1.66 1.66 1.59 1.49 1.61 Retention Time Mean 3.562 4.504 5.370 7.398 8.006 10.564 %RSD 0.02 0.03 0.02 0.01 0.02 0.01 Excellent repeatability for both peak area and RT thanks to EPC C control and automatic injection

7820A FID Wide Linear Dynamic Range 1.00E+08 Response Factor 1.00E+07 1.00E+06 1.00E+05 1.00E+04 1E-09 1E-08 1E-07 1E-06 1E-05 0.0001 0.001 0.01 0.1 Mass(g) 空气 H2 + 尾吹气 喷嘴 Benefit: (high and low concentrations coexisting in the sample) No longer needs either external or internal standard method, easy touse Area Normalization method will help generate the same good quality of data No need to change scale, all compound tested in one sample injection Page 33

Application Highlights Environmental Organochlorine pesticides in drinking water analysis μecd s provides high sensitivity and selectivity for organochlorine pesticides analysis. Meets the rugged related regulation across borders. Using Nitrogen as the carrier gas tremendously saves cost compared with helium ALS and EPC ensure good repeatability and ease of use. Page 34

Organochlorine Pesticides Standard Analysis 1. α BHC 2. Lindane 3. β BHC 4. δ BHC 5. p,p DDE 6. o,p DDT 7. p,p DDD 8. p,p DDT Hz 160 155 150 145 140 135 130 125 1 1 2 2 3 3 4 4 0.5 μg/l (0.5 ppb) pesticides standard Sample size: 1uL, Splitless Oven temperature program: 50 C (3 min); 30 C/min to 210 C (30min) μecd s s high sensitivity ensures the trace organochlorine pesticides analysis a at 0.5 μg/l with good S/N 5 5 12 14 16 18 20 Minutes 22 24 26 28 30 Min 6 6 7 7 8 8 Page 35

Organochlorine Pesticides in Drinking Water Analysis 1. α BHC 2. Lindane 3. β BHC 4. δ BHC Hz 2000 1800 1600 1400 1200 1 10 ppb pesticides spiked drinking water 2 5. p,p DDE 6. o,p DDT 7. p,p DDD 8. p,p DDT 1000 800 600 400 200 μecd s s high sensitivity and selectivity ensures the trace organochlorine pesticides in real sample. 3 4 5 6 7 8 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Sample size: 1uL, Splitless Oven temperature program: 50 C (3 min); 30 C/min to 210 C (30min) Min Page 36

Organochlorine Pesticides Aanalysis linearity Peak Compounds Linear Corresponding No. range(ppb) Coefficient ( R 2 ) 1 α-bhc 0.5-500 0.9998 2 β-bhc 0.5-500 0.9998 3 lindane 0.5-500 1 4 δ-bhc 0.5-500 0.9996 5 p,p -DDE 1-500 0.9998 6 o,p -DDT 1-500 0.9998 7 p,p -DDD 0.5-500 0.9999 8 p,p-ddt 0.5-500 0.9993 Unique turbulent mixing and electrical design offer wide linear response range for μecd

Summary Reliable, ease of use but cost saving solution is 7820A GC customer s need Excellent reliability, high sensitivity, wide dynamic range and costsaving solution is demonstrated in two application examples HPI down stream, food safety, and environmental are 7820A GC target industries 7820 is the easy choice for your routine analysis