Heat stress index. Dewpoint. pressure. altitude

Similar documents
Kestrel 4500 Pocket Weather Tracker

ea980r Digital Anemometer User Manual

Kestrel 4000 Pocket Weather Tracker

WM9280. Pro Family weather station with T/H sensor, pluviometer, anemometer, PC connection and Meteotime weather forecasts until 3 days

Mini Environmental Quality Meter

Pocket Weather Meter with Backlight

QUICK START GUIDE Kestrel 5000 Environmental Meter Kestrel 5100 Racing Weather Meter Kestrel 5200 Professional Environmental Meter

The Kestrel Handheld Weather Tracker. 1) If the unit is configured to log data and it is turned off, will it continue to log temperature data?

Pocket Weather Meter with Backlight

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

473 Dew Point Hygrometer

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

USER GUIDE 1000, 2000, 2500 & 2500NV, 3000, 3500 & 3500NV, 3500DT.

E THERMADATA LOGGER Humidity & temperature recording meter

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

473 Dew Point Hygrometer

473-SHX Dew Point Mirror

Wireless Weather Station Instruction Manual

Weather Monitoring Station Features Easy Wireless Installation and Solar Power

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Automatic titrators, TitroMatic

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Complete Moisture Analysis

WEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather

Manual Weather Stations & Instruments

ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Performance Measurements for Mechanical Air Handling Systems

Vantage Vue Weather Station

Edgetech Instruments Inc.

Dewpoint Meter Data Sheet / Instructions

TM360 TEMP-SEEKER PRECISION THERMO-PSYCHROMETER OPERATION MANUAL

Humidity Calibration Solutions

2100TR Liquid Scintillation Counter

How to use the MMU-EGS Meteorological field instruments

Data Sheet / Instructions. Dewpoint MeterO

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

Engineering Specification

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

Pyschrometric Sample Problem Pharmaceutical Engineering Graduate Program New Jersey Institute of Technology

06MAR THU 12: User Manual

Windwatch PRO Pocket Weather Station

ED 701 General Industry Pressure Transmitter

Product Description. 1 of 6

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement

National Event Tree. **Combo Package** Eliminator 2000 Super & National Event Tree. Item # 3152 $849

Humidity Calibration Solutions

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

CABLE FREE WEATHER STATION

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

Hadrons Desktop U.S. Atomic Clock & Weather Station

Cabled Vantage Pro2 & Vantage Pro2 Plus Stations

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

SENSORS CLIMATRONICS CORPORATION (631) MANUAL TACMET II WEATHER STATION, EMI 2.0 INSTALLATION 1.0 INTRODUCTION

QUICK SET UP MANUAL WEATHER CENTER

Understanding the uncertainties associated with using the 5128A RHapid Cal portable humidity generator

Chilled Mirror Hygrometry

Weather Stations. Evaluation copy. 9. Post live weather data on the school s web site for students, faculty and community.

U.S. Atomic Clock & Weather Station. Instruction Manual

REALIZATION OF HUMIDITY STANDARD FACILITY USING TWO-PRESSURE HUMIDITY GENERATOR AND HUMIDITY CHAMBER

Vantage PRO2 Quick. Reference Guide

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Anemometer Thermometer Hygrometer

CLOCKS MARATHON WATCH COMPANY LTD.

SwemaMan 7 Operating instructions vers 1.13 MB_CW

3. Analytical measurement and testing Timing/Clocks-Climate measurement/hygrometer

Complete Moisture Analysis

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

La Crosse Technology. Heavy Weather Pro. Software User s Guide. (for 2800 series weather stations with USB connectivity) Revision: 1.

INSTRUCTION MANUAL for No. 45 Altimeter-Compass

OPERATING INSTRUCTIONS

Quick Reference Guide

MxVision WeatherSentry Web Services Content Guide

2 ACCESSING VARIOUS MODES

Labcell Water Activity Instruments

WS-9018U Wireless Weather Station. Instruction Manual

Atmosphere Properties and Instruments. Outline. AT351 Lab 2 January 30th, 2008

Visual Tutorial. Pitot Static System Simulator. Adobe (formerly Macromedia) Flash Requirements

CABLE FREE TM WEATHER STATION

Rapid RH Portable ph Meter. User's Manual

Instruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector

All-In-One Wireless Professional Weather Station (DCF) (975246)

Speedtech Deerhunter s EDGE TM Model HE-1. Speedtech ECO EDGE TM Model EE-1. User s Manual

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

IMPORTANT. Questions? Contact Customer Support at (877) or visit Display for 5-in-1 Weather Sensor model 06016RM

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

SLH-K Handheld Ultrasonic Flowmeter

Fischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual

MICHELL TECHNOLOGIES FOR MOISTURE. Calibration. General Principles & Theory, Equipment Considerations

Innovative Sustainable Technology

O P E R A T I N G M A N U A L

Assembly and Operation Manual. April 2016

Transcription:

Kestrel 4200 Measures Volume air flow in cfm, L/s, m³/s, m³/m, m³/h Air velocity (current, average, and maximum) Heat stress index Windchill Relative humidity Dewpoint in F or C Humidity ratio Barometric pressure Wet bulb temperature Altitude Density altitude Tired of cumbersome equations to calculate CFM? Like the 4100, the Kestrel 4200 has taken the calculations and guess-work out of air flow measurements with automatic air flow readings. The convenient averaging mode ensures accurate CFM readings in any airflow or duct size and shape. For immediate and accurate air flow readings, simply: 1. Enter the duct shape and dimensions. 2. Hold the 4200 in the air flow. 3. Volume air flow readings are displayed... no calculator required!

Innovative Design and Features The Kestrel 4200 makes HVAC technicians jobs even easier with automatic wet bulb temperature and humidity ratio readings. Of particular interest to dehumidification professionals, the Kestrel 4200 measures relative humidity, dewpoint, wet bulb temperature and heat stress index as well as the humidity ratio and the patented dual chamber humidity sensor assures fast and accurate readings in any environment. This multi-functional precision instrument also measures: volume air flow, air velocity, barometric pressure, altitude, wind chill, heat stress index, temperature, relative humidity and dewpoint, either ambient or in any accessible airflow. Easy-to-Use Data Logging & Computer Upload The Kestrel 4200 air flow meter features a powerful data logger that records 1600 sets of measurements at user-selectable time intervals (over 2 years of data can be recorded). Logged data can be reviewed with the 4200 s on-screen graphing capabilities, or uploaded to a PC for in-depth review. The optional Kestrel Interface and accompanying Kestrel Communicator software makes long-term storage, indepth analysis and detailed charting of stored data a breeze. With on-screen customization, the 4200 can truly be personalized for every technician. Easy set-up screens allow the unit to display only relevant readings, and hide screens not relative to the job. Plus the Kestrel s user screens group pertinent information on one easily referenced screen. NIST-Traceable Accuracy Don t let the inexpensive price tag fool you the Kestrel 4200 is as accurate as instruments costing far more. Every Kestrel is individually calibrated to NIST-traceable standards and comes with a free Certificate of Conformity. (Individual NIST certificates and recalibration are also available.) Consider the 4100 s hold and averaging functions, and it s the only instrument HVAC technicians need to perform a variety of jobs. Kestrel 4200 Features Waterproof and floats Backlight for low light conditions Data Logger (automatic and manual) Customizable data storage - 1600 data points Minimum, Maximum and Average values Multi-Function 3-line display Data charting Humidity sensor can be recalibrated in the field with our Relative Humidity Calibration Kit. User-replaceable impeller Flip-top impeller cover Upload to a computer (with optional interface) Five languages (English, French, Spanish, German, and Italian) US Patent Nos. 5,783,753 and 5,939,645 and 6,257,074 5-year warranty Assembled in the USA Kestrel 4200 Includes Soft carry pouch Neck lanyard Batteries - 2 AAA

Kestrel Certificate of Conformity Measurement Response Time Units Operational Range Resolution Accuracy (+/-) Specification Range Wind Speed m/s 0.4 to 60.0 m/s 0.1 Larger of 3% of 0.4 to 40.0 m/s reading or ft/min 59 to 11,948 1 least significant ft/min digit 59 to 7877 ft/min km/h 1.0 to 218.0 km/h mph 0.8 to 135.0 mph 0.1 1.0 to 144.0 km/h 1 0.8 to 89.0 mph knots 0.6 to 118.3 kt 0.1 0.6 to 78.0 kt Beaufort 0 to 12 B 0.1 0 to 12 B 1 inch diameter impeller with precision axle and sapphire bearings. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH / 7 m/s. Sustained operation above 60 MPH / 27 m/s will wear impeller rapidly and may cause destruction of impeller. Replacement impeller (NK PN-0801) may be field-installed without tools (US Patent 5,783,753). Air Flow cfm 0 to 99,999 cfm 1 3% of reading 0 to 99,999 cfm m3/h 0 to 99,999 m3/h 1 0 to 99,999 m3/h m3/m 0 to 99,999 m3/m m3/s 0.0 to 9,999.9 m3/s 1 0 to 99,999 m3/m 0.1 0.0 to 9,999.9 m3/s L/s 0 to 99,999 L/s 1 0 to 99,999 L/s Automatically calculated from Air Velocity measurement and user-specified duct shape (circle or rectangle) and dimensions (units: in, ft, cm or m). Maximum duct dimension input: 258.0 in / 21.5 ft / 655.3 cm / 6.55 m. F -49.0 to 257.0 F C -45.0 to 125.0 C 0.1 1.8 F -20.0 to 158.0 F 0.1 1.0 C -29.0 to 70.0 C Measures air, water and snow temperature. Thermally isolated, hermetically sealed, precision thermistor mounted externally (US Patent 5,939,645). Calibration drift negligible. Relative Humidity %RH 0.0 to 100.0 % 0.1 3.0 %RH 5.0 to 95.0 % noncondensing

Polymer capacitive humidity sensor mounted in thin-walled chamber external to case for rapid, accurate response (US Patent 6,257,074). (To achieve stated relative humidity accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and must be kept out of direct sunlight.) Calibration drift +/- 2% over 24 months. Relative humidity may be recalibrated at factory or in field using Kestrel Humidity Calibration Kit (NK PN- 0802). Pressure (mb & PSI 4000 model only) inhg 0.3 to 32.5 inhg hpa / mb 10.0 to 1100.0 hpa / mb PSI 0.15 to 16.0 PSI 0.01 0.05 inhg At 77.0 F, 22.1 to 32.5 inhg 0.1 1.5 hpa / mb At 25.0 C, 750 to 1100 hpa / mb 0.01 0.02 PSI At 77.0 F, 10.9 to 16.0 PSI Monolithic silicon piezoresistive pressure sensor with second-order temperature correction. Maximum error over temperature range 32 to 158 F (0 to 70 C), +/- 0.06 inhg / +/-2.0 hpa. Calibration drift typically -0.03 inhg / -1.0 hpa per year. Pressure sensor may be recalibrated at factory or in field. Altitude ft -6000 to 30000 ft m -2000 to 9000 m 1 50 ft At 77.0 F, <19,700 ft. Max error +/- 98 ft 1 15 m At 25.0 C, <6,000 m. Max error +/- 30 m compensated pressure (barometric) altimeter. Wind Chill F 0.7 to 135.0 MPH, -49.0 to 257.0 F C 0.4 to 60.0 m/s, -45.0 to 125.0 C 0.1 1.8 F 1.8 to 89.0 mph, - 50.0 to 50.0 F 0.1 1.0 C 0.4 to 40 m/s, -45.6 to 10.0 C Calculated from the primary measurements of wind speed and temperature. Utilizes the NWS Wind Chill (WCT) Index, revised 2001, with wind speed adjusted by a factor of 1.5 to yield equivalent results to wind speed measured at 10 m above ground. (Specification temperature limits established by WCT Tables.) Heat Index F 0.0 to 100.0 %RH, -49.0 to 257.0 F C 0.0 to 100.0 %RH, -45.0 to 125.0 C 0.1 3.6 F 70.0 to 130.0 F, 0 to 100% RH 0.1 2.0 C 21.1 to 54.4 C, 0 to 100 %RH Calculated from the primary measurements of temperature and relative humidity. Utilizes the NWS Heat Index (HI) tables. (Specification temperature limits established by HI tables.) Dewpoint F 0.0 to 100.0 %RH, -49.0 to 257.0 F C 0.0 to 100.0 %RH, -45.0 to 0.1 3.6 F -20.0 to 158.0 F, 20.0 to 95.0% RH 0.1 2.0 C -29.0 to 70.0 C, 20.0 to 95.0 %RH

125.0 C Calculated from the primary measurements of temperature and relative humidity. to which the air would need to be cooled at a constant pressure to become saturated. Wet Bulb F -49.0 to 257.0 F, 0.0 to 100.0 %RH, 8.86 to 32.48 inhg C -45.0 to 125.0 C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hpa 0.1 3.6 F 32.0 to 100.0 F, 5.0 to 95.0% RH, 8.86 to 32.48 inhg, <19700 ft 0.1 2.0 C 0.0 to 37.8 C, 5.0 to 95.0 %RH, - 2000.0 to 9000.0 hpa, <6000 m Calculated from the primary measurements of temperature, relative humidity and pressure. indicated by a wet bulb psychrometer. Humidity Ratio gpp 0.000 to 5000.0 gpp 0.1 typical accuracy 10% -20 to 130 F, 5 to 95% RH, 8.86 to 32.48 inhg g/kg 0.00 to 720.0 g/kg 0.01 typical accuracy 10% -29 to 54 C, 5 to 95% RH, 300.0 to 1100.0 hpa Calculated from the primary measurements of temperature, relative humidity and pressure. The measure of Grains/lb of dry air, called the humidity ratio, is an indication of the mass of water vapor in air. Density Altitude ft -49.0 to 257.0 F, 0.0 to 100.0 % RH, 8.86 to 32.48 inhg m -45.0 to 125.0 C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hpa 1 246 32.0 to 100.0 F, 5.0 to 95.0 %RH, 8.86 to 32.48 inhg, <19700 ft 1 75 0.0-37.8 C, 5.0 to 95.0 %RH, -2000 to 9000 hpa, <6000 m Calculated from the primary measurements of temperature, relative humidity and pressure. Air density converted to equivalent sea level elevation at the International Standard Atmosphere. Max/Avg Wind Speed (Air Velocity), Crosswind, Headwind/Tailwind Data Storage / Display Data Upload Display Display Update One-button clear and restart of Max Wind Gust and Average Wind measurement. Minimum, maximum, average and logged history stored and displayed for every measured value. 1600-point data logger with graphical display. Auto data storage; interval settable from 2 seconds to 12 hours. Manual data capture. Requires optional PC interface (NK PN-0830) and provided software. RS-232 connection with USB adapter available. Multifunction, multi-digit programmable dot-matrix display..

Display Backlight Clock / Calendar Operational Range (LCD and Batteries) Storage Auto Shutdown Languages Certifications Batteries Environmental Dimensions Choice of aviation green or visible red electroluminescent backlight. Automatic or manual activation. Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment. The operational temperature range of the liquid crystal display and batteries is 14 F to 131 F / -10 C to 55 C. Beyond the limits of the operational temperature range, the unit must be maintained within range and exposed for minimum time necessary to take reading. -22 F to 140 F / -30 C to 60 C. User-selectable: 15 or 60 minutes with no key presses or disabled. English, French, German, Italian, Spanish. CE certified. Individually tested to NIST-traceable standards (written certificate of tests available at additional charge). AAA Alkaline, two, included. Average life, 400 hours of use, +/-depending on backlight use. Waterproof (IP67 standard). Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage replaceable impeller.). Unit 5.0 x 1.8 x 1.1 in / 12.7 x 4.5 x 2.8 cm. Weight Unit 3.6 oz / 102 g. Kestrel Meters are designed and manufactured at NK s facility in Boothwyn, Pennsylvania, and are individually calibrated at the time of manufacture. Every Kestrel Meter comes with a Certificate of Conformity to document the unit s accuracy all Kestrel measurements are traceable to the National Institute of Standards and Technology, ensuring the highest level of reliability. Additional NIST Calibration and Certification services are available.