INF195 Infrared Thermometer

Similar documents
EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

InfraRed Thermometer with Laser Pointer

Thermometer Line. today s laboratory and field

THERMYS 150. Advanced field reference thermometer / temperature calibrator

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

Dual laser + type K thermometer INFRARED THERMOMETER

INFRARED THERMOMETER TM0819

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

T h e rm i s t o r s

INSTRUCTION MANUAL Fax: (503)

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

566/568. Infrared Thermometers. Getting Started

DIGITAL THERMOMETER OPERATOR S MANUAL

Bimetal Industrial Thermometers

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

One-hand ph/temperature measuring instrument

Compact ph Measuring Instruments With Pro Engineering

The Fluke 66 and 68 Infrared Thermometers

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

INFRARED THERMOMETER Model : TM-959

INSTRUCTION MANUAL RS 51 & RS 52 DIGITAL THERMOMETER

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Clausing Industrial, Inc. Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

473 Dew Point Hygrometer

Temperature Calibration

473 Dew Point Hygrometer

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

E THERMADATA LOGGER Humidity & temperature recording meter

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Introduction to Blackbody Sources

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

VIBRATION METER. Instruction Manual.

ph / Temperature Meter for Cheese with Application Specific Probe

473-SHX Dew Point Mirror

Analog - Digital multimeters

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

Infrared Thermometer Model CA879

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

DGCU165-5B 36 W. Five-Burner Cooktop

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Experiment A4 Sensor Calibration Procedure

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

INSTRUCTION MANUAL DTH Fax: (503)

Heat stress index. Dewpoint. pressure. altitude

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar

FVBSS fixed volume bottle

[ ] Sensors for Temperature Measurement, and Their Application 2L R 1 1 T 1 T 2

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

CHAPTER 15. Introductory Engineering Design 179

THERMOCOUPLE CHARACTERISTICS TRAINER

MONITORING & CONTROL LABORATORIES FOR ALL YOUR LABORATORY REQUIREMENTS 50% THERMOMETER & HYDROMETER

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Designed to go where you work

Kestrel 4500 Pocket Weather Tracker

product manual H-3220A Benkelman Beam

Digital Controller Operation

testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

WW12C, WW08C, WW06C, WW04C, WW02C. Low ohm chip resistors ( power ) Size 1206, 0805, 0603, 0402, 0201

Scope of Accreditation For ISOLAB Inc. Calibration

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

CHIP RESISTOR. Chip Resistors Selection Guide. General Purpose Chip Resistor. Zero Ohm Jumper Resistor. Chip Resistor Array MAX WORKING VOLTAGE

Surface-mounting thermostats Series ATH

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Inside Wall Temperature Measurements of DSTs Using an Infrared Temperature Sensor

VISUAL LEVEL INDICATORS

Surface-mounting Thermostats ATH Type Series

General Purpose Relays Types K, R, N, and C

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Operating Instructions for Digital Manometer. Model: MAN-SD

LCS Laboratory Inc. 700 Collip Circle, Unit 218, London ON, N6G 4X8, (519) ,

Part Number Range Accuracy Printing WP * Probe Special User LDC with Page Logging included Feature Cal Backlight

product manual H-4204 Proving Ring Penetrometer

Positive Signal The most technologically advanced. double coated dichroic filters are used, which transmit

Pressure Transmitter ED 701

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

CLOCKS MARATHON WATCH COMPANY LTD.

Temperature Scales. Temperature, and Temperature Dependent on Physical Properties. Temperature. Temperature Scale

Air velocity & IAQ measuring instruments

IR/Thermistor Pen. Instruction Manual

REPAIR PARTS. DX17VS Outdoor Inverter. This manual is to be used by qualified technicians only.

Air velocity & IAQ measuring instruments

REFRIGERATOR RM3862 MODEL SERIES PARTS LIST. Series MODEL RM3862

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

2 AllSync Wired Clock System

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Chemistry MultiMeasure Sensor PS-2170

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

GS-IR 8816 Series Infrared Thermometer

Wenzhou Tripod Instrument Manufacturing Co., Ltd.

FFHT1831QE2 FFHT1831QM2 FFHT1831QP2 FFHT1831QQ2 FFHT1831QS2

Thermal Mass Flow Meter for Gases

Jumbo Cross Beam Ionizer

Transcription:

DIGITAL TEMPERATURE TESTERS 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com INF195 Infrared The INF195 is perfect for frequent use in advanced or specialty application environments, where wide temperature ranges and superior optics are essential for use on targets at greater distances. This full-featured infrared thermometer is the most comprehensive and best-valued infrared thermometer on the market. Features: -76 ~ 1022 F (-60 ~ 550 C) 12:1 Distance to spot ratio MIN/MAX, Differential, Average 3 Emissivity levels: (0.30, 0.70, 0.95) Hi/low alarm (user adjustable) K-Type thermocouple input Holster Also included in this Data Sheet INF165, DT15A, DT20A, DTK2 Digital Pocket s, Dial and Liquid s DTK2KIT Differential Temperature Kit

INFRARED THERMOMETERS INF165 Infrared INF195 Infrared -36.4 ~ 689 F (-38 ~ 365 C) 12:1 Distance to spot ratio -76 ~ 1022 F (-60 ~ 550 C) 12:1 Distance to spot ratio K-Type thermocouple input Selectable emissivity (0.70, 0.95) Max value capture Lase targeting Backlit display Auto off 3 Emissivity levels: (0.30, 0.70, 0.95) MIN/MAX, Differential, Average Hi/low alarm (user adjustable) Lase targeting Backlit display Carrying case, 2 (AAA) Batteries, Manual Carrying case, 2 (AAA) Batteries, Manual INF165 Measurement range -36.4 to 689 F (-38 to 365 C) Operating range 32 to 122 F (0 to +50 C) Accuracy (Tobj= 0 ~ 365 C) +/-2.5% of reading or (2.5 C) 4.5 F whichever is greater (Tobj -36.4 ~ 0 C) ± (2.5 C (4.5 F)) + 0.05 / per degree) Emissivity 0.70, 0.95 Resolution (-9.9 ~ 199.9 F) 0.2 F/0.2 C Response Time (90%) 1 second Distance Spot Ratio 12:1 Battery life Standard AAA (x2) 1.5V, 14 hours continuous Dimensions 6.9 X 1.5 X 2.8 Weight 6.3 oz including batteries 2 AAA 1.5 batteries INF195 Item Non-contact Thermocouple Probe Infrared Scan Measurement range -76 to 1022 F -83.2 to +1999 F (-60 to +550 C) (-64 to 1400 C) Operating range 32 to 122 F (0 to +50 C) Accuracy ±2% RDG or 2 C (4 F) ±1% of reading or 1.8 F (Tobj= 0 ~ 550 C) whichever is greater (1.0 C) whichever is greater (Test under (Tobj= -60 ~ 0 C) ((±2 C (4 F) Tamb=73±6 F) + 0.05 /per degree) Resolution 0.1 F / 0.1 C (-9.9 ~ 199.9 F) Response time (90%) 1 second Distance: Spot 12 : 1 Battery life Standard AAA (x2), 140 hours Dimensions 6.9 x 1.5 x 2.8 (175.2 x 39.0 x 71.9mm) Weight 6.7 oz including batteries NOTE: Under the electromagnetic field of 2V/m from 200 to 600 MHz, the maximum error is 18 F (10 C). K-Type Temperature Probes (INF195) ATT29 4 Standard fiber glass coated. ATT36 8 Surface probe and handle. ATT100 6 Liquid probe and handle. (-40 to 950 F / -40 to 51 ATTPC2 1/4" ~ 1 1/2" Clamp Style Adapter for use with K-type inputs ATTEXT 10 Extension for K-type thermocouples ATT29 ATT36 ATT100 ATTPC2 ATTEXT

DIGITAL Functions NEW DTK2 Dual Input Digital Dual thermocouple input -328 to +2498 F (k-type) T1 - T2 (Differential) Automated ice bath in-field calibration NEW DTK2KIT Differential Temperature Kit Features Auto power off with disable feature Large LCD screen C/ F select function MIN/MAX 3 year limited warranty Includes Specifications (2) K Type bead temperature probes, 9V Battery, Manual, Carrying Pouch (2) K Type bead temperature Probes, (2) K-type Pipe Clamp Adapters, Carrying Case, 9V Battery, Manual DTK2 Temperature Range K-Type: -328 F ~ 2498 F (-200 C ~ 1370 C) Temperature Unit C or F Selectable Display Resolution 0.1 C (0.1 F) Accuracy ±(0.2% + 1.4 F) ±(0.2% + 1 C) Input Protection Max voltage of temperature input is 24V DC Temperature Coefficient 0.01% of reading + 0.03 C per C 0.01% of reading + 0.06 F per F When out of range 18 C ~ 28 C (64 F ~ 82 F) Size 6 1/4 x 2 1/8 x x 1 1/2 (H x W x D) ATT29 ATT29A ATT100 K-Type Temperature Probes ATT29 4 Standard fiber glass coated. ATT29A 4 Standard fluoroplastic coated. ATT29APACK 10 PACK 4 Standard fluoroplastic coated. ATT36 8 Surface probe and handle. ATT37 8 Right angle surface probe and handle. ATT50 8 Liquid probe & handle. (-40 to 1,550 F / -40 to 850 C) ATT100 6 Liquid probe and handle. ATTPC 1/4" ~ 3" Pipe clamp adapter for use with K-type inputs. ATTPC2 1/4" ~ 1 1/2" Clamp style adapter for use with K-type inputs. ATTEXT 10 Extension for K-type thermocouples ATT50 ATT36 ATT37 ATTPC ATTPC2 ATTEXT

TEMPERTURE TESTERS DT15A Single Input Digital -58 to 571 F (-50 to 300 C) Singe thermistor input Responds quickly to temperature changes DT20A Dual Input Digital -58 to 571 F (-50 to 300 C) Dual thermistor input Responds quickly to temperature changes High visibility backlit display Dual display lets you monitor any two of T1, T2 or differential ( T) High visibility backlit display One replaceable, submersible metal probe, 3 (AAA) Batteries, Manual Two replaceable, submersible metal probes, 3 (AAA) Batteries, Manual DT15A, DT20A Range Resolution Accuracy -50 to -20 F/ C 1-19.9 to 199.9 F/ C 0.1 200 to 571 F 1 ±(1% reading +1.5 F/ C) 200 to 300 C 1 Inputs Single (DT15A) Double (DT20A) Size 5 1/2 x 3 x 1 1/4 (H x W x D) Weight.44 lbs. Nominal resistance 100KΩ COMING SOON! Thermistors ATT55A ATT56A ATT57A ATT58A 4 Liquid temperature probe with 30 cord. 4 Air temperature probe with 30 cord. 4 Surface temperature probe with 30 cord. Sealed probe with 15 cord. ATTPC3 Pipe Clamp Thermistor ATT55A ATT56A ATT57A ATT58A

THERMOMETERS Digital Pocket s PDT550 Pocket Waterproof -58 to 572 F (-50 to 300 C) Built-in magnetic mount Dual purpose probe cover serves as thermometer extension Auto power off Quick and easy to read Colors available: Red, Green,Yellow, Blue, Black PDT650 Folding Pocket -58 to 572 F (-50 to 300 C) Built-in magnetic mount Auto power off Large easy to read display 550B Digital Pocket Protective boot Magnetic mount -58 to 572 F Water resistant MIN/MAX Auto power off New ergonomic designed head Dial And Liquid s RFT2A Refrigeration/Freezer Heavy-duty stainless steel, dial type refrigeration thermometer -20 to 80 F (-30 to 30 C) 2 F/1 C per division Hangs or stands Stainless steel frame RF60A Vapor Tension -40 to 60 (-40 to 15 C) 2 F/C per division 2" Dial with 3" mounting flange 48" Nickel plated, rear-mounted capillary Color-coded scales Easy pointer calibration DOT2A Oven 200 to 550 F (65 to 290 C) 25 F/10 C per division Hangs or stands Stainless steel frame RH60 Vapor Tension -40 to 60 F (-40 to 15 C) 2 F/C per division 2" Dial with hanger strap 48" Nickel plated capillary with bottom connection Color-coded scales Easy pointer calibration FG80K Refrigeration/Freezer -40 to 80 F (-40 to 27 C) Large 5 x 1 1/4 scale plate Red spirit-filled (contains no mercury) Hangs or stands G120 & G220 Vapor Retension Mercury free! Glass spirit with protective sleeve Range: G120: -40 to 120 F G220: 0 to 220 F Pocket Dial s #Stock Scale Deg./Div. Range Length T160 1 2-40 ~ +160 F 5 T220 1 2 0 ~ +220 F 5 TC70 1 1-40 ~ +70 C 5 TC100 1 1-10 ~ +100 C 5 T125/3 1-3/4 1 +25 ~ +125 F 5 T160/3 1-3/4 2-40 ~ +160 F 5 T220/3 1-3/4 2 0 ~ +220 F 5

T E M P E R A T U R E P R O B E S J-Type Temperature Probes (for use with DT301, DT302, DT304 Digital Logging Themometers) ATT19 48 Standard bead probe w/ clip. (-40-950 F / -40-510 C) ATT26 8 Liquid probe and 48 cord. (-40-1,550 F / -40-850 C) ATT27 48 Standard bead probe. (-40-950 F / -40-510 C) ATT19 ATT26 ATT27 ATT30 ATT30 8 Liquid probe & handle. (-40-1,550 F / -40-850 C) K-Type Temperature Probes ATT29 Standard bead probe w/ 48 fiber glass coated wire. ATT29A Standard bead probe w/ 48 fluoroplastic coated wire. ATT29APACK 10 PACK (ATT29A) ATT29 ATT29A ATT36 ATT37 ATT36 8 Surface probe and handle. ATT37 8 Right angle surface probe and handle. ATT39 Storable bead probe w/ 36 fluoroplastic coated wire for the DT301, DT302, DT304. ATT50 8 Liquid probe & handle. (-40 to 1,550 F / -40 to 850 C) ATT39 ATT50 ATT70 ATT100 ATT70 Temperature plug adapter for DMMs and Clamp Meters. ATT100 6 Liquid probe and handle. ATTPC 1/4" ~ 3" Pipe Clamp Adapter for use with K-type inputs. ATTPC2 1/4" ~ 1 1/2" Clamp style adapter for use with K-type inputs. ATTEXT 10 Extension for K-type thermocouples ATTPC ATTPC2 ATTEXT Thermistors ATT55A 4 Liquid temperature probe with 30 cord. ATT56A 4 Air temperature probe with 30 cord. ATT57A 4 Surface temperature probe with 30 cord. ATT58A Sealed probe with 15 cord. ATTPC3 ATT55A 1/4 ~ 1 1/2 Clamp style adapter for use with thermistor inputs. ATT56A ATT57A ATT58A ATTPC3 CAN'T FIND WHAT YOU'RE LOOKING FOR?... COMING SOON! UEi offers a full line of HVAC/R and combustion testing equipment. We have grouped our products specifically to make it easy to find what you're looking for. Here are a few related products and data sheets. For a complete list visit: www.ueitest.com Product Part # or Group LIT # Apollo Digital Logging s L310 Refrigeration Products L351 Combustion & Environmental Catalog L330 NOW TWO U.S. SERVICE CENTER LOCATIONS We are proud to announce the opening of our newest service center located in Indianapolis. This provides the additional resources to respond quickly to calibration, repair or warranty requests. All service shipments received at UEi are scheduled as normal turn around and prioritized as first come first serve to the facility most able to complete the service turn around. Priority service is available by appointment only. For a service request, please contact us: 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com L352 BRID424 3K 11/13