PERFORMANCE EVALUATION OF DIMMABLE LIGHTING SOURCES WITH FLUORESCENT TUBES FOR INDOOR APPLICATIONS

Similar documents
Optimisation and control of energy lighting consumption in offices

SHP-T Basic Plus. Sa Shp-T 150w Basic Plus E40 PRODUCT OVERVIEW DATA TABLE. Optical data. Range Features. Colour temperature (K) 2000 CRI (Ra) 20

Powerful, ultra-slim circular lamps

A NEW GENERATION OF ECGs QUICKTRONIC MULTIWATT ONE FOR MANY THERE IS LIGHT. AND THERE IS OSRAM.

Test report of IES LM Approved Method: Electrical and Photometric

Measurement method for the proficiency testing program

QTi DALI-T/E 2X18 42/ DIM

LM-79 Report TEST REPORT NO.M037D

MASTER TL5 Lamps. The Safety and. fit. TrustSight LED Emergency drivers. A full range of MASTER TL5 Lamps

LM-79 Report TEST REPORT NO. L523A

The official directions are written in Chinese, this English edition is for your reference only -1-

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

Product Description HPI-T. Quartz metal halide lamps with clear outer bulb

PrevaLED COIN 50 COB G1

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

TEST REPORT. Test Method : See the attached sheets.

Photometric Test Report

TEST REPORT. Page 1 of 11

Seeing colors in a natural way

CLUSTERLITE CONTENTS MEGAMAN

solid state LED LED LED LED LED LED Light Emitting Diode: LED LED module Self - ballasted LED module Integral LED module

2x led tubes 150 cm in build-in luminaire ARM2x1500-A-INB-G4-NW by Led Light Europe

PrevaLED COIN 50 DC COB G1

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

Report No.: HZ p. (Lumens) Stabilization Time CRI (K)

/ / /

Lamp measurement report - 10 Nov 2017 LED Lamp 230V bulb 6W Filament Warm White E27 Clear Dimmable by TopLEDshop

Photometric Report. 42 Partners Limited 21 Woden Road Wolverhampton WV10 0AU UK

Integrating Sphere Spectroradiometer System for LED LPCE-2(LMS-8000A) Brochure. Global Office of Lisun Electronics Inc.

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

IES LM TEST REPORT For Shenzhen sunper opto co., ltd

Product Description. MASTERColour CDM-R

Lamp measurement report - 28 Jan 2014 AR111 led lamp GU10 WW 40deg dimmable by TopLEDshop

Lamp measurement report - 11 June 2016 LED Lamp 230V bulb 6W Filament warm white E27 clear by TopLEDshop

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

Lamp measurement report - 23 Jan 2017 LED Lamp 230V 6W warm white GU10 dimmable ceramic by TopLEDshop

SHP-TS GroLux. SHP-TS 600W GroLux PRODUCT OVERVIEW

Lamp measurement report - 2 Nov 2013 AR111 led light spot GU10 WW 40deg not dimmable by TopLEDshop

IES LM TEST REPORT For EIKO GLOBAL, LLC

PHOTOMETRIC TESTING & EVALUATION TO IES LM Sample Tested LN130-A30 LED HIGH BAY. Prepared for: Janie Chung

ROUNDED - SHAPED LAMPS

Test Report. Report No.: EED35I R1. Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P

Test Report. Report No.: EED35I Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P

Lamp measurement report - 24 Aug 2013 Led Tube T8-CB3014H W 4000K by DMLUX Verlichtingsarmaturen

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

Lamp measurement report - 14 Sep 2014 QB-LLB-5W-DC Q-Bright E27 LED Bulb 2800K 5W 500LM Dimmable Clear by Eleqtron

Lamp measurement report - 19 April 2014 led tube 24 Watt High Lumen 150cm frosted CW by Esttech

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

ST T indoor batten fluorescent light fitting. USE ADVANTAGES IP20

Lamp measurement report - 3 Oct V led strip 2500K 10.5W.m-1 by TopLEDshop

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

Optimal light performance for short or long operation per switch-on Multiple light color choice Good color rendering (CRI > 80)

Lamp measurement report - 18 Sep 2017 Led Tube 6A by Lighthero GmbH

HONOURTEK Delux Array Series HRA0303 Preliminary

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD

LEDs in ERCO luminaires

IES LM MEASUREMENT AND TEST REPORT For

Lamp measurement report - 11 April 2013 OX-sign by Ledhuys BV

HONOURTEK Delux Array Series HRA0407 Preliminary

Photometric Test Report

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

Lamp measurement report - 18 Jan 2013 Led tube light 150 cm 5500K by Demeterled BV

Lamp measurement report - 11 May 2015 liniled PCB Green Power by Triolight B.V.

Lamp measurement report - 21 Jan 2014 AR111 led spot light G53 WW 40 degrees by TopLEDshop

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Seeing colors in a natural way

LEDs in ERCO luminaires

IES LM MEASUREMENT AND TEST REPORT. For

Lamp measurement report - 25 Jan 2015 LED spot light GU10 5W 2700K dimmable by TopLEDshop

Flux-O-Meter. Making luminous flux measurements more accessible. Andrew Bierman, Martin Overington

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

PRODUCT FAMILY DATASHEET LEDVANCE FLOODLIGHT LED STD

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

OLLA White Paper on the Necessity of Luminous Efficacy Measurement Standardisation of OLED Light Sources

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Cat# LED High Bay

Lamp measurement report - 18 Feb 2016 OX-profile 1500mm 4000K by Overhuys Verlichting BV

Lamp measurement report - 5 Aug 2013 LED light 12V 10W warm white AR111 by TopLEDshop

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

Product Description. MASTERColour CDM-T. Benefits. Features. Application. Versions

LUMINOUS MEASUREMENTS

Get your city ready for the future with DigiStreet

Lamp measurement report - 26 June 2012 Led street light 120W by Lemnis Lighting Asia

Transcription:

SINAIA 2006 International Lighting Symposium «Modern Quality Solutions for an Efficient Lighting» 12-14 October 2006, Sinaia, Romania PERFORMANCE EVALUATION OF DIMMABLE LIGHTING SOURCES WITH FLUORESCENT TUBES FOR INDOOR APPLICATIONS Benoit ROISIN*, Arnaud DENEYER**, Peter D HERDT**, Silvia-Maria DIGA***, Christian EUGENE* ABSTRACT In the frame of a research work aimed to analyze and optimize the lighting installations performances in offices, two papers are presented in this symposium. In this first paper, various lighting sources with fluorescent tubes are experimentally tested in order to identify their performances, mainly their power consumption. A 20% economy in power consumption can be obtained with high grade fluorescent tubes and electronic ballasts by comparison to standard material. Dimmable electronic ballasts are especially considered and the consequence of their dimming on the performances of the lighting installation. In a second paper, simulations will be performed using the results of this first part in order to evaluate the lighting power consumption in a typical office. 1. INTRODUCTION The tertiary sector, essentially composed of buildings, represents more than 40% of the total energy consumption in Europe. A decrease of the European energy demand requires thus a better energy performance of buildings. Lighting installations represent a significant part of this consumption (about 35% of the total primary energy consumed in buildings like offices and schools). This justifies the aim of this work which is to analyze and optimize lighting installations performances in offices. Only lighting with fluorescent tubes (the main light source in use in this type of buildings) is addressed in this work. Our study is twofold. In a first paper, which is here of concern, various systems are experimentally tested in order to identify their performances, namely their power consumption, in function of their using mode. Some of the results obtained will be used in a second paper [1], devoted to perform simulations in order to evaluate the lighting energy consumption (on a yearly basis) in a typical office according to different strategies. Modern lighting systems using electronic ballasts EB (mainly dimmable - DEB) are focussed in this study. Comparison is made with tubes driven with classical ferromagnetic ballast (FB). The luminous efficacy of the lamp (luminous flux divided by the total consumed power) is here mainly addressed. 2. MEASUREMENT METHODOLOGY 2.1 Power measurement The main measurements of concern are related to the power consumed by the tube itself and the different auxiliaries (ballasts, control gears, sensors) depending on the dimming level (when applicable). Note that when speaking about P tube, we include

the power consumed by the two heaters (or filaments). Other electrical quantities as power factor, RMS voltages and currents, harmonic content are also of interest. Figure 1 represents a tube driven by an electronic ballast (EB). We observe that the tube itself and the ballast are multi-terminals components preventing the direct measurement of the power they consume (unlike the input power to the whole system which is a two-terminal circuit authorizing the simple wattmeter connection as on the figure the wattmeter is here represented by the traditional scheme of an electrodynamic instrument even if it is actually an electronic one). The solution is to use the (n-1) wattmeter method where n is the number of terminals, consisting to successively measure the power with the wattmeter sensing the current of each of the (n-1) lines and the voltage between this line and the n th line taken as reference, and then to sum up algebraically these results for obtaining the searched power. Figure 1. EB driven tube with wattmeter in total power measurement configuration Figure 2 gives the way to measure the power consumed by the tube. Since this one has four terminals (the two filaments), three power measurements are needed. The Voltech ballast CT is an electronic current transformer, the role of which is to insure a galvanic isolation between both wattmeter circuits: it has the property of a high band-pass appropriate to HF signals (see next paragraph). Figure 2. Power measurement of the tube Another difficulty with electronic ballasts is that the frequency at the tube side is in the ultrasonic range (typically between 20 and 80 khz depending on the dimming we denote it as the HF range). As, furthermore, the HF signals are distorted, it requires the use of an instrument the band-pass of which is several hundred of khz! Now that the input power and the power at the tube are known, the power consumption of the ballast is simply the difference between the two former ones. This is perhaps simple but with the negative consequence of a possible poor relative accuracy on this quantity because it represents only a small fraction of the other

powers. We recall that the modulus ρ c of the relative error on a quantity C resulting from the difference between two other quantities A and B is in the worst case: A ρ A + B ρb ρ c = A B leading to a severe relative error on C when A and B are close together. Applying this in our case: P ballast = P total P tube where P total and P tube are measured separately with a relative error ρ, the worst case gives: wattmeter P total + Ptube ρ ballast = ρwattmeter Pballast If, as a realistic example, P ballast is about 10% of P tube, we obtain: ρ ballast 20 ρ wattmeter. In order for this error to be acceptable, the wattmeter error has to be very low. The electrical quantities were measured with a digital power analyzer of rather good performances: the VOLTECH PM100 model (www.voltech.com). It guarantees an accuracy of about 0.4% on P total and only a few percent on P tube (this figure is poorer due to the HF signals). For the reasons explained above, the values obtained for P ballast are only indicative. 2.2 Flux measurement The luminous output of the tube is very simply measured on a relative level thanks to a photo-sensor clipped at a random place on the tube and aimed to it. Note that the spectral sensitivity of the detector is here irrelevant because we can suppose that the light spectrum is independent of the dimming level. This configuration allows for instance the evolution of the luminous efficacy of a tube (in lm/w) to be evaluated in function of the dimming. But for comparison between different tubes, an absolute calibration is required. This is performed, for each lamp under study, in a classical Ulbright sphere at nominal regime of the tube. For reason linked to the age of the material used and the lack of recent calibration, it is reasonable that we don t claim for the absolute flux values (in lm) an accuracy better than 10%, which is nevertheless acceptable for this study. 3. MATERIAL UNDER TEST 3.1 - T8 Philips tube Master TLD super 840 58 W with dimmable electronic ballast (DEB) Philips HF-Regulator HF-R 158 TL-D 3.2 - T8 Sylvania tubes - Tube Sylvania Luxline plus 840 58 W - Tube Sylvania Luxline 133 58 W - Tube Sylvania Luxline plus 840 36 W - Tube Sylvania Luxline 133 36 W The model 840 lamp is of high colour rendering index and high efficacy (typically 90 lm/w) while the model 133 is of standard quality (efficacy of 80 lm/w) With the following ballasts : - dimmable electronic ballasts (DEB) Osram-Quicktronic De Luxe HF 158 or 136 DIM - conventional ferromagnetic ballasts (FB) (from the brand Vossloh-Schwabe)

3.3 - Control gears and detectors We also considered different control systems, including sensors combining presence detection and daylight measurement. We were essentially focussed on the solutions proposed by the Belgian company ETAP (www.etaplighting.com), namely the ELS + MDD (or MDS) systems but similar solutions exist elsewhere. Without any presence in the room, the flux is reduced to a preset value (or simply cut off); when a person enters in the detection field, the luminous flux is controlled by an analogue 1-10V DC voltage in function of the daylight (detected by a light dependent resistor) by way of a Control-it control unit (equivalent to Philips LRC 1010 TRIOS light controller). This unit can act by luminaire or at a centralized level. A DALI (Digital Addressable Lighting Interface) control unit is also available for DALI electronic ballasts inserted in a DALI network. We observed a very limited (typically about 2 W) power consumption of these control units and sensors: therefore, their contribution in the total power consumption is not taken into account: in the results below. 4. RESULTS 4.1 Philips ballasts Figure 3 gives the powers in function of the luminous flux (relative to the nominal or full flux) for the Philips system (tube + DEB). We observe a remarkable linearity of the total power in function of the relative flux. The regression straight line is: P tot = 0.46 Φ relat.% + 9.0 (W) The constant term of this expression (justified by the fact that the ballast consumption is not nil even with the tube in turn-off state) leads to the conclusion that the luminous efficacy (in lm/w) decreases in function of the dimming depth. We also note that the ballast consumption is rather independent of the dimming (and close to the constant term 9.0 W), with the consequence that the power at the tube is also approximately linear in function of the flux, which is a rather foreseeable conclusion since this power is essentially transformed in radiating power which is, for a constant spectrum, proportional to the luminous flux. 4.2 Osram ballasts - Osram HF 1x58 DIM There is practically no power difference between the two types of tube (Sylvania 840 or 133). The regression straight line for the total power is P tot = 0.47 Φ relat.% + 8.7 (W) which is very close to the law obtained with the Philips system. We also verified by absolute flux calibration the difference of about 13% between the flux emitted by both lamps, as expected in the data sheets. - Osram HF 1x36 DIM Same comments. The linear law is P tot = 0.29 Φ relat.% + 6.8 (W)

Total power [W] Tube power [W] Ballast power [W] 60,0 50,0 40,0 Power [W] 30,0 20,0 10,0 0,0 0,0 10,0 20,0 30,0 40,0 50,0 60,0 70,0 80,0 90,0 100,0 4.3 Ferromagnetic ballasts Luminous flux [%] Figure 3. Powers in function of relative flux for Philips system (HF 158 TL-D tube + ballast) These conventional ballasts are of course non dimmable by a controlling (analogue or digital) access. We observe with the different models under test that generally the flux is close to the nominal flux with electronic ballasts (it means that the manufacturers guarantee a certain inter-changeability concerning the light output) but at the price of higher total power (even if the ballast consumption is also similar to the corresponding electronic models). We actually observe a decreasing in luminous efficacy of about 10% with conventional ferromagnetic ballasts which is conform to what is mentioned in the literature. 4.4 Total power absolute flux linear law The linear relationship (regression line) mentioned above for the different dimmed systems is given in Table 1 in term of the total power (in W), this time in function of the absolute flux (in lm). The data given are rounded taking into account the fact that our flux measurements are not guaranteed at more than 10%, which is appropriate for practical purposes. The higher slope with standard tube for a same nominal power is the consequence of its lower luminous efficacy. These simple formulas are very useful and as far as we know are given for the first time. They are derived from our experiments with Philips, Sylvania or Osram materials which are the dominant brands on the market but, of course, these formulas are not guaranteed for other materials.

58W high efficacy tube with ad-hoc dim. ballast 58W standard tube with ad-hoc dim. ballast 36W high efficacy tube with ad-hoc dim. ballast 36W standard tube with ad-hoc dim. ballast P tot = 0.0100 Φ(lm) + 9 (W) P tot = 0.0114 Φ(lm) + 9 (W) P tot = 0.0100 Φ(lm) + 7 (W) P tot = 0.0114 Φ(lm) + 7 (W) 4.5 Luminous efficacy Table 1. Total power absolute flux linear law Figure 4 synthesizes the different results regarding the luminous efficacy in function of the luminous flux. One among the comments that we can do on this graph is that for a fixed flux, the luminous efficacy is higher for a 36W system than for a 58 W system. It is therefore preferable to install systems of lower electrical power and to use them at lower dimming depth (closer to their nominal regime) than systems of higher power but deeper dimmed. 90 DEB 36W w/ high efficacy tube DEB 36W w/ standard tube DEB 58W w/ high efficacy tube DEB 58W w/ standard tube FB 58W w/ high efficacy tube FB 58W w/ standard tube FB 36W w/ high efficacy tube FB 36W w/ standard tube 80 70 Luminous efficacy [lm/w] 60 50 40 30 20 10 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Luminous flux [lm] Figure 4. Luminous efficacy (lumen/total power) versus flux 4.6 Power factor Recall the definition of the power factor (PF): P PF = URMS IRMS It concerns here the input of the system tube plus ballast (total power) and has to be as high as possible for optimizing the connection of the lamp to the mains. This parameter is thus also of concern when speaking about the tube performances in dimmed regime. Generally spoken, it is observed that the power factor decreases in function of the dimming depth. See Figure 5

DEB 36W DEB 58W 1,00 0,95 0,90 Power factor [-] 0,85 0,80 0,75 0,70 0,65. 0,60 0,00 10,00 20,00 30,00 40,00 50,00 60,00 70,00 80,00 90,00 100,00 Luminous flux [%] Figure 5. Power factor versus relative flux (OSRAM ballasts) 5. CONCLUSIONS - Choice of high grade tubes is recommended for their higher luminous efficacy of more than 10% - Use of electronic ballasts (EB) in place of ferromagnetic ballasts (FB) allows a reduction of about 10% of the total power consumption - Dimmable electronic ballasts (DEB) are obligatory for light management (see [1]) - DEB s have poor performances at deep dimming (dramatic decrease in luminous efficacy, power factor and harmonic purity). If a large dimming range is not required, it is thus advisable to design the installations in order that their tubes are working near their nominal regime - DEB s exhibit a linear relationship of their flux in function of the total power. This facilitates the study of a new installation (see [1]) - The power consumption of lighting management systems (including sensors) has a relative weak contribution to the whole power consumption. 6. ACKNOWLEDGEMENTS This research work was funded by the Walloon Government. The authors wish to thank the ETAP company for its support in this project. 7. REFERENCES 1. ROISIN B., DE NEYER A., D HERDT P., EUGENE C., Optimization of Lighting Power Consumption in Office. Sinaia 2006 International Lighting Symposium, 7 pages *Prof. Dr. Eng. Christian EUGENE and Eng. Benoit ROISIN are at the Electrical Department, Université catholique de Louvain, Louvain-la-Neuve, Belgium, Eugene@lei.ucl.ac.be **Eng. Arnaud DENEYER and Eng. Peter D HERDT are at the Belgian Building Research Institute, Limelette, Belgium, arnaud.deneyer@bbri.be ***Prof. Dr. Eng. Silvia-Maria DIGA is at Facultatea de Electrotehnica, Universitatea di Craiova, Romania, sdiga@elth.ucv.ro