T H E R MOF L O C. : : h o t p a p e r f o r e n e r g y - s a v e r s! Insulation made of cellulose fibre. : : R o o f i n s u l a t i o n

Similar documents
Underlayment. bonded impact sound insulation

8.1 Product data sheet

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying

12.1 Schlüter -KERDI-BOARD

The Highland - List of materials needed to construct a weather tight home.

SYNTHETIC ROOFING TILES

Hygrothermal Performance of Ventilated Cold Roofs an Experimental Study

12.1 Product data sheet

8.6 Product data sheet

12.1 Product data sheet

S E A L E D F L A T E X P A N S I O N J O I N T T A P E S

R I B E L E M E N T S

SWARCO LIMBURGER LACKFABRIK GmbH Road Marking Systems. 1-component Afterglow paint system TECHNICAL INFORMATION

Development of a small-scale reverberation room

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

Hygrothermal Properties and Performance of Sea Grass Insulation

TREES Training for Renovated Energy Efficient Social housing

6.1 Product data sheet

EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION

6.1. Schlüter -DITRA 25. Application and Function. Underlayment Uncoupling, waterproofing and vapour pressure equalisation. Product data sheet

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying

Precision Leaded Resistors

Lumber Supplies and Equipment. South Texas Moulding DBA Texas Wood Supply. McCoy's Building Supply. Precision Saw & Tooltex, Inc.

Technical information CONCRETE / SOLID STONE. Reaction resin mortar, epoxy-acrylate-based with styrene USAGE INSTRUCTIONS

Simple Building Estimating. Example Reports

From Table 1 4. DL = [12 lb/ft 2 # in.(6 in.)] (15 ft)(10 ft) = 10,800 lb. LL = (250 lb/ft 2 )(15 ft)(10 ft) = 37,500 lb.

Measurement of Acoustic Properties of light weight concrete SL-Deck

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

LED light engine / OLED LED compact. Umodule STARK DLE CLASSIC STARK DLE 82,8 54,4. Ordering data

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

Load-Carrying Capacity of Timber - Wood Fibre Insulation Board - Joints with Dowel Type Fasteners

Schlüter -DITRA-HEAT-E

Drying out capacity and snow melting risk for ventilated wooden roofs - a parameter study

Quarries National Joint Advisory Committee (QNJAC) Occupational Health. Information Sheet 10. April Management of Asbestos on Site

S TRUCTUR A L PR E- A N A LYSIS TA B LES

BUILDING HOME CONSTRUCTION

a 1 ft2 144 in 2 b 26 in.

Calcul des coefficients d'absorption alpha sabine

Collector test according to EN ,2:2006

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying

Collector test according to EN ,2:2002

VK2 volume flow controller Overview

Installation membrane

Weathertightness testing of Solar Slate Plate to MCS012. Prepared for: Michael Share. Solar Slate Plate. 24 th June Test report number

FORMWORK SAVINGS ADAPTABILITY LIGHT WEIGHT ECONOMICAL ALUMINIUM SLAB FORMWORK. BV Cert

Slot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L

1 /square Intermittent temperature range -250 C to 150 C (-420 F to 300 F) Continuous temperature range -250 C to 120 C (-420 F to 250 F)

*These are the vinyl for MAX Bepop Cutting/printing machines. We have 100mm (4in) and 200mm(8in) width models available in North America.

DUST SETTLING USING A NEGATIVE IONIZATION SYSTEM

9.4 Product data sheet

Analytical and experimental study of single frame double wall

Winter Thermal Comfort in 19 th Century Traditional Buildings of the Town of Florina, in North-Western Greece

ISO INTERNATIONAL STANDARD

How to Determine the Long-Term Performance of Vacuum Insulation Panels

Homework #4 Solution

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Design for Airtightness and Moisture Control in New Zealand housing

Condensation Risk Analysis

Swirl Diffusers Type DLA 7 and DLA 8

Winter Weather Roofing: Cold, Hard Facts

SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM

Assoc. Prof. Dr. Ruta MINIOTAITE

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

SBi 2010:06. Multidimensional HAM conditions Measurements on full-scale wall elements in the large climate simulator at SBi

laminated on both sides for effective anchoring in the tile adhesive.

ALC. ALBATROSS Supply air terminal for large airflows

SCREEN LOW E SATINÉ 5500 LOW E

W e a t h e r S e a l s for Windows and Doors. E x c e l l e n c e i n S h a p e a n d F u n c t i o n

SCREEN LOW E SATINÉ 5500 LOW E

Laboratory for Acoustics

Standard Assessment Procedure

CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level. PHYSICS 5054/02 Paper 2 Theory October/November 2003

Users Manual. Marshall Day Acoustics. Double Panels Contact 33 Details Marshall Day 37.8 Acoustics PO Box

Requirements to perform accurate dielectric material analysis

Recommended Hole Pattern: [mm]

2. Climate (Outdoor) Altitude. Distance from the ocean. Conditions of the ocean. Store/release heat. angle of solar radiation Amount of solar energy

Window air permeability measurement, watertightness and resistance to wind load (designation of the test)

@Copyright 2016 SKAPS Industries.

Pre-owned - 8 colour press FA-Line: FA-4* NEXT CLEANINKING #F4733 MODULAR 16" MULTI-SUBSTRATE FLEXO PRESS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series

TFI Report Sound Absorption Impact Sound Insulation

The External Thermal Insulation Composite System (ETICS) More than comfort and energy saving

EFFECTS OF PROTECTIVE PANELS ON CHARRING OF TIMBER ELEMENTS IN TIMBER FRAME ASSEMBLIES

Chemical Storage Guide

6.4 Product data sheet

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

Acoustic spaces: comfort and social sustainability

5. AN INTRODUCTION TO BUILDING PHYSICS

Liquid Polybutadienes and Derivatives

PRODUCT SAFETY SUMMARY (GPS) SODIUM-HYDROXIDE

Non-licensed Work with Asbestos Training

ACRYSOL TT-935 Rheology Modifier

AFT. Advanced Friction Tester. Static and dynamic coefficient of friction Fast, repeatable measurements Compliant to multiple standards

IBIDEN Group Green Procurement Guidelines. (Version 6)

the distance of conduction (the thickness), the greater the heat flow.

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

Today s A/C systems include:

Transcription:

T H E R MOF L O C Insulation made of cellulose fibre : : h o t p a p e r f o r e n e r g y - s a v e r s! : : t h e t r e n d t o w a r d s i n t e l l i g e n t i n s u l a t i o n! : : R o o f i n s u l a t i o n : : W a l l i n s u l a t i o n : : F l o o r i n s u l a t i o n

Thermofloc Insulation_ Contents Thermofloc Products Overview in detail 3 Thermofloc Blow- in Insulation 4-5 Thermofloc Blow-in Insulation Roofs, walls, floors 6-9 Thermofloc Floor Filling 10-11 Thermofloc Insulation Pellets 12-13 Thermofloc Vapour- Proof Lining 14-15 Thermofloc Roof Sheathing Rolls 16-17 Thermofloc Adhesive Tapes 18-19

T h e T h e r m o f l o c insulation system - t h a t s p l e a s a n t l y c o o l i n s u m m e r & c o s i l y w a r m i n w i n t e r! ➐ ➑ 5) 1) THERMOFLOC Blow-in Insulation f o r i n s u l a t i n g b e t w e e n t h e ra f t e r s i n t h e r oof 2) THERMOFLOC Blow-in Insulation b l o w n o n a s a n o p e n l a y e r t o i n s u l a t e c e i l i n g s o n t h e t o p s t o r i e s o f b u i l d i n g s 3) THERMOFLOC Blow-in Insulation f o r i n s u l a t i n g o u t e r wa l l s 5) Thermofloc Floor Filling for insulating hollow spaces in intermediate ceilings 6) Thermofloc Blow-in Insulation sprayed onto the underside of cellar ceilings 7) Thermofloc Roof Sheathing Rolls 8) Thermofloc Vapour-Proof Lining 4) Thermofloc Insulation Pellets a s a s u p p o r t i n g f l o o r s u b s t r u c t u r e

Thermofloc_ Philosophy B l o w - i n I n s u l a t i o n B l o w - i n I n s u l a t i o n T H E M O S T I M P O R TA N T A R E A S O F A P P L I C AT I O N - the roof (steep roof, pent roof, hipped roof, flat roof) - the outer wall and inner wall - the ceiling on the top storey Used in both new buildings and in the renovation of old buildings, THERMOFLOC Blow-in Insulation has been proving its worth for decades. A S P E C I A L A R E A O F A P P L I C AT I O N - where the insulation is sprayed onto the inner walls of rooms (brickwork or concrete too), ceilings e.g. cellar ceilings) and roofs. For this purpose, a 30 to 60 mm layer is usually sprayed on.

insulation T h e T h e r m o f l o c p e r m a n e n t l y c u t s e n e r g y c o s t s! system : : R o o f i n s u l a t i o n : : W a l l i n s u l a t i o n : : F l o o r i n s u l a t i o n T h e r m o f l o c B l o w - i n I n s u l a t i o n THERMOFLOC Blow-in insulation made of cellulose fibres has many important product features which enable an efficient insulation for reducing energy costs, while including ecological considerations as well. One outstanding feature of the Blow-in Insulation, which is produced from old newspapers, is that it provides optimal insulation during both the cold and the warm seasons, thus markedly reducing energy costs for heating in the winter and for air conditioning in the summer. Construction projects are regularly conducted in over 12 European countries using natural THERMOFLOC fibres, and the number of builder-owners who are convinced of the benefits of a THERMOFLOC insulation system is growing daily. I n s u l a t i o n e x p e r t i n f o : w w w. t h e r m o f l o c. c o m

Thermofloc_ Blow- in Insulation B l o w - i n I n s u l a t i o n B l o w - i n I n s u l a t i o n THERMOFLOC is installed by means of specially equipped blowing machines. The insulation is thereby pumped into hoses under air pressure, transported further into the hollow spaces of the building components, and there compressed in accordance with the material handling instructions, to produce an uninterrupted, complete insulation layer. The special handling technique H a s c o n s i d e ra b l e a d va n t a g e s b o t h f o r t h e p e r son installing the insulation and the builder-owner. The builder-owner benefits through having an uninterrupted insulation layer that is free of thermal bridges. Old roofs can be insulated later without removing the roof tiles. Through the creation of an insulation layer that is open to diffusion, the builder-owner can enjoy an ecologically compatible, cosy atmosphere in his living area.

T h e T h e r m o f l o c insulation system - 1 0 0 % e c o l o g i c a l & 1 0 0 % c o s y : : R o o f i n s u l a t i o n : : W a l l i n s u l a t i o n : : F l o o r i n s u l a t i o n The processor can create a layer of between 20 and 500 mm from one single product, due to which there is no need to keep different insulation sizes in storage (as in the case of insulation panels and insulation felts). The compression ratio of the insulation thereby lies between 25 kg/m 3 and 65 kg/m 3, according to the area of application. There is practically no waste, as only the exact amount of insulation that is necessary for a particular construction is blown into the building component. Furthermore, it simplifies building site logistics, as the insulation materials in the building no longer have to be transported by hand. Thanks to the blow-in technique, all higher parts of the building (multi-storey buildings) can be filled with no problem.,this saves time and speeds up the execution of the project. ThermoFloc Blow-in Insulation Approval and monitoring ETA-05/0186, CE number Components Newspapers, with borates as preservative agents Heat co-efficient λ D 0.039 W/mK Water vapour diffusion resistance μ1 Water absorption 14.5/35.19 kg/m Flow resistance 6.1 kpa s/m² Fire classification in acc. with EN 13501-1 B-s2,d0 Resistance against mould Class 0 Metallic corrosion No potential for metallic corrosion Harmlessness to health Free of hazardous substances as defined by ETA-05/0186

Thermofloc_ Areas of Application B l o w - i n I n s u l a t i o n B l o w - i n I n s u l a t i o n R O O F Insulation thickness = 140-300 mm U-value = 0.21-0.11 W/mK ➐ ➑ Insulation thickness = 140-300 mm U-value = 0.23-0.11 W/mK ➐ ➑ ➒ ➒ Roof system D1 Roof covering Roof lathing Counter lathing THERMOFLOC Roof Sheathing Rolls Roof Sheathing Rafters/THERMOFLOC Blow-in Insulation ➐ Thermofloc Vapour-Proof Lining ➑ Lathing ➒ Plaster board Roof system D5 Roof covering Roof lathing Counter lathing THERMOFLOC Roof Sheathing Rolls Roof Sheathing Edgewise beam/thermofloc Blow-in Insulation ➐ THERMOFLOC Vapour-Proof Lining ➑ Fireproof sheathing ➒ Rafters visible Insulation thickness = 140-300 mm U-value = 0.25-0.12 W/mK Insulation thickness = 140-300 mm U-value = 0.14-0.10 W/mK ➐ ➑ ➒ ➐ Roof system D2 Roof covering Roof lathing Counter lathing THERMOFLOC Roof Sheathing Rolls Rafters/THERMOFLOC Blow-in Insulation Lathing 2-6 cm ➐ Thermofloc Vapour-Proof Lining ➑ Lathing installation level ➒ Plaster board Roof system D7 Roof covering Roof lathing 4/5 Counter lathing 5/8 Bitumen soft fibre board Double web T-beam/THERMOFLOC Blow-in Insulation Sperrholz/OSB ➐ Plaster board

insulation T h e T h e r m o f l o c P o i n t f o r p o i n t b e t t e r i n s u l a t e d! system : : R o o f i n s u l a t i o n : : W a l l i n s u l a t i o n : : F l o o r i n s u l a t i o n W A L L Insulation thickness = 140-300 mm U-value = 0.23-0.12 W/mK Insulation thickness = 60-220 mm U-value = 0.37-0.17 W/mK Wall system W1 Wood cladding Lathing Wood fibre insulation board Crossbar/THERMOFLOC Blow-in Insulation Evenly spaced slats Thermofloc Vapour-Proof Lining ➐ Lathing (installation level) ➑ Plaster board ➐ ➑ Wall system W13 Vertically perforated bricks THERMOFLOC Blow-in Insulation Vertically perforated bricks Interior plaster Insulation thickness = 140-300 mm U-value = 0.24-0.12 W/mK Insulation thickness = 140-300 mm U-value = 0.23-0.12 W/mK 4) ➐ Wall system W15 Gypsum fibre board Gypsum fibre board Gypsum fibre board Crossbar/THERMOFLOC Blow-in Insulation Thermofloc Dampfbremsvlies Gypsum fibre board Wall system W10 Gauged mortar Wood-wool lightweight board Soft fibre board Crossbar/THERMOFLOC Blow-in Insulation OSB plywood Lathing/THERMOFLOC Blow-in Insulation ➐ Gypsum fibre board

Thermofloc_ Floor Filling Floor Filliing F l o o r F i l l i n g Unlike the Blow-in Insulation, THERMOFLOC Floor Filling is processed by hand and used exclusively as a non- pressureresistant insulation at the horizontal level (ceiling on the top storey, between joists in a wood-joist floor construction). In order to ensure better manual processing, the insulation material is less compressed in the packaging. THERMOFLOC Floor Filling is available in 12 kg sacks, with 24 sacks per pallet. The insulation material is simply poured on evenly to achieve the desired insulation thickness and then spread to form a level surface. Material consumption is approx. 35 kg/m 3. The technical data is identical to that of the Blow-in Insulation. 10

insulation T h e T h e r m o f l o c p e r m a n e n t l y c u t s e n e r g y c o s t s! system : : W a l l i n s u l a t i o n : : F l o o r i n s u l a t i o n Insulation thickness = 140-300 mm U-value = 0.22-0.11 W/mK Insulation thickness = 140-300 mm U-value = 0.24-0.12 W/mK Insulation thickness = 140-300 mm U-value = 0.24-0.12 W/mK Floor construction DB1 Tie-beam insulation Wood-wool board Subfloor/Rough floor Tie beams/thermofloc Blow-in Insulation Evenly spaced slats Thermofloc Vapour-Proof Lining Gypsum wallboard Floor construction DB3 Ceiling OSB/Plywood Beams/Thermofloc Blow-in Insulation Thermofloc Vapour-Proof Lining Spring rails 2-ply gypsum wallboards Insulation of a ceiling on the top storey of a building Beams/Thermofloc Blow-in Insulation Thermofloc Vapour-Proof Lining Concrete ceiling ThermoFloc Floor Filling Approval and monitoring Components Heat co-efficient ETA-05/0186, CE number Newspapers and borate as a preservative λ D 0.039 W/mK Water vapour diffusion resistance μ 1 Water absorption Flow resistance Fire classification in acc. with EN 13501-1 14.5/35.19 kg/m 6.1 kpa s/m² B-s2,d0 Resistance against mould Class 0 Metallic corrosion No potential for metallic corrosion Harmlessness to health Free of hazardous substances in acc. with ETA-05/0186 Thermofloc THE Film You can request this film about production, handling and practical application from Peter Seppele Ges.m.b.H. in 6 languages, or download this information under www.thermofloc.com 11

Thermofloc_ Insulation Pellets Insulation Pellets I n s u l a t i o n P e l l e t s THERMOFLOC Insulation Pellets are granules made from cellulose fibres, which can be used for floor construction. The granules, which are 3-8 mm in size, are simply poured on to produce the desired installation height and afterwards spread to form a level surface. In this way, subfloor constructions with an installation height of 30-80 mm can be created. Due to the high piled weight (500 kg/m 3 ), THERMOFLOC Insulation Pellets are particularly suited for the construction of supporting insulation layers, resulting in outstanding noise insulation. No matter whether in a concrete ceiling or a wooden beam ceiling the insulation qualities of both types of construction can be markedly improved using THERMOFLOC Insulation Pellets. 12

insulation T h e T h e r m o f l o c - o n e s i m p l y m u s t i n s i s t o n i t! system : : F l o o r i n s u l a t i o n : : C e i l i n g i n s u l a t i o n Insulation thickness = 30-80 mm U-value = 0.48-0.32 W/mK Insulation thickness = 30-80 mm U-value = 0.54-0,35 W/mK Insulation thickness = 80-160 mm U-value = 0.33-0.24 W/mK Floor construction DB7 Ceiling Timber floor board Soft fibre N+F Soft fibre cover panel THERMOFLOC Insulation Pellets Waterproof layer Fireproof sheathing Floor construction DB14 Ceiling Timber floor board Soft fibre N+F Soft fibre cover panel THERMOFLOC Insulation Pellets Concrete ceiling Ceiling plaster Floor construction DB15 Ceiling Floor tiles Gypsum fibre board Soft wood fibre THERMOFLOC Insulation Pellets Concrete ceiling Ceiling plaster ThermoFloc Insulation Pellets Granule size Piled weight Piled height Fire classification 3-8 mm 500 kg/m³ max. 80 mm per layer B2 Thermal conductivity λ D 0.07 Pressure resistance Water vapour diffusion μ 1 Material consumption Delivered in the form of 40 litre sacks/36 sacks per pallet/1.44m 3 6.320 kg with 10 % compression 40 l per m² (piled height 40 mm), 60 l per m² (piled height 60 mm) 13

Thermofloc_ Vapour- Proof Lining Vapour-Proof Lining Vapour-Proof Lining T H E R M O F L O C Va p o u r- P r o o f L i n i n g i s a v a p o u r- p r o o f a n d a i r- t i g h t m a t e r i a l w h i c h p r o t e c t s c o n s t r u c t i o n s a g a i n s t damp. It can be used for wall and roof constructions in the interior of buildings. Thanks to its additionally reinforced structure, it has a greater tear strength and can be excellently combined with THERMOFLOC Blow- in Insulation. Free delivery with THERMOFLOC insulation materials Item No. 5150 (Width 150 cm) Item No. 5160 (Width 280 cm) THERMOFLOC Vapour-Proof Lining Raw material Tear strength Technical Data reinforced polypropylene fibrous lining 100 N / 5 cm, additionally reinforced Weight per m² ca. 50-60 g/m 2 Elongation at tear > 25 % SD value 10 m Brand classification B2; used on interior of roofs and walls Roll width 150 cm or 280 cm Roll length 50 m m 2 per roll 75 m 2 or140 m 2 14

insulation T h e T h e r m o f l o c - I n s u l a t e d w i t h q u a l i t y c o m p o n e n t s! system : : R o o f i n s u l a t i o n : : W a l l i n s u l a t i o n Area of application: THERMOFLOC Vapour-Proof Lining is used on the interior of ventilated and non-ventilated roof constructions and in the walls of wooden crossbar structures. The use of THERMOFLOC Vapour-Proof Lining prevents weak points in the construction due to draughts, thus preventing the penetration of moisture into the thermal insulation. Installation instructions: THERMOFLOC Vapour-Proof Lining is fastened to the substructures by means of tacking or gluing. The lining must be installed with the foil side facing inwards to the room, i.e. with the fibrous side facing the thermal insulation. A lengthwise installation of the Vapour-Proof Lining is to be recommended in the case of THERMOFLOC Blow-in Insulations. Should it be necessary to install it crosswise, the points where adhesive tape is used must be covered with continuous lathing in order to prevent THERMOFLOC Adhesive Tape from becoming detached due to the blowin pressure. The areas to be stuck down must be free of grease, dust and silicone, and also completely dry. 15

Thermofloc_ Roof Sheathing Rolls Roof Sheathing Rolls Roof Sheathing Rolls T H E R M O F L O C R o o f S h e a t h i n g R o l l s p r o t e c t t h e c o n s t r u c t i o n from driving rain and thus prevent a n y p e n e t ration of moisture into the roof or wall s t r u c t u r e. The rolls are UV stable, particularly tearr e s i s t a n t a n d extremely open to diffusion. Free delivery with THERMOFLOC insulation materials Item No. 5158 Item No. 5159 Item No. 5162 Item No. 5167 Roof Sheathing Rolls are installed overlapping on the outside of the roof, under the roof covering, to provide optimal protection against wind and rain. The counter lathing is nailed or tacked onto the Roof Sheathing Rolls, and thus fixed in place at the same time. T H E R M O F L O C R o o f S h e a t h i n g R o l l s h a v e a 10 year guarantee. Coordinated system components provide optimal insulation. 16

insulation T h e T h e r m o f l o c - S y s t e m a t i c a l l y t h o u g h t o u t! system : : R o o f i n s u l a t i o n Item No. 5158 Item No. 5159 Roof Sheathing Roll Grey Technical Data Roof Sheathing Roll Green Technical Data Raw material 3-ply polypropylene fibrous lining Raw material 3-ply polypropylene fibrous lining Tear strength 215 N / 5 cm Tear strength 250 N / 5 cm Weight per m² 120 g/m 2 Elongation at tear > 60 % Weight per m² 135 g/m 2 Elongation at tear > 60 % SD value 0.02 m 0.02 m, extremely open to diffusion SD value 0.02 m, extremely open to diffusion Fire classification B2 Fire classification B2 Outdoor exposure max. 2 months Outdoor exposure max. 4 months Nail tear strength 220 N Nail tear strength 250 N Roll width 150 cm Roll width 150 cm Roll length 50 m Roll length 50 m 30 rolls per pallet/2,250 m² 24 rolls per pallet/1,800 m² Item No. 5162 Item No. 5167 Roof Sheathing Roll Blue Technical Data Roof Sheathing Roll XL Black Technical Data Raw material 3-ply polypropylene fibrous lining Raw material 3-ply polypropylene fibrous lining Tear strength 380 N / 5 cm Tear strength lengthwise 400 N/crosswise 310 N/ 5 cm Weight per m² 160 g/m 2 Elongation at tear > 60 % Weight per m² 260 g/m 2 Elongation at tear > lengthwise 40 % / crosswise 50 % SD value 0.02 m, extremely open to diffusion SD value 0.02 m extremely open to diffusion Fire classification B2 Fire classification B2 Outdoor exposure max. 4 months Outdoor exposure max. 4 months Nail tear strength 290 N Nail tear strength 200 / 170 N Roll width 150 cm Roll width 150 cm Roll length 50 m Roll length 50 m 24 rolls per pallet/1,800 m² 24 rolls per pallet/1,800 m² 17

Thermofloc_ Adhesive Tapes Adhesive Tapes A d h e s i v e T a p e s Our adhesive tapes are specially adapted to our THERMOFLOC products and, together with the Vapour-Proof Lining and ROOF SHEATHING ROLLS, constitute a complete thermal insulation system. The adhesive tapes are used for the air-tight sealing of Item No. 5151 THERMOFLOC Vapour-Proof Lining and ROOF SHEATHING ROLLS. In addition, they can be used for sticking down joint connections onto derived timber product boards (e.g. OSB boards, plywood boards, etc.). Free delivery with THERMOFLOC insulation materials Green Adhesive Tape Technical Data Raw material Roll width Roll length Carton Pallet Polyethylene adhesive tape 5 cm 25 m 12 pcs. 60 cartons The adhesive coating consists of solvent and emollient-free acrylate. Reinforced green polyethylene adhesive tape with acrylate glue, for air-tight sealing of areas where THERMOFLOC Vapour-Proof Linings are perforated or overlapping. Item No. 5156 White Adhesive Tape: Technical Data Raw material Roll width Roll length Carton Pallet Polyethylene adhesive tape 20 cm 20 m 1 pcs. 112 cartons The adhesive coating consists of solvent and emollient-free acrylate. White universal adhesive tape for sealing blow-in openings 18

insulation T h e T h e r m o f l o c - c a r e f u l l y p l a n n e d p r e c i s i o n s e a l i n g! system : : R o o f i n s u l a t i o n : : W a l l i n s u l a t i o n Item No. 5157 Black Adhesive Tape Technical Data Raw material Roll width Roll length Carton Pallet Polyethylene adhesive tape 14,6 cm 25 m 4 pcs. 80 cartons The adhesive coating consists of solvent and emollient-free acrylate. Universal black adhesive tape on a polyethylene basis, with carrier material reinforcement layer and release paper with perforation slits, for sealing blow-in openings. Item No. 5166 Double-sided blue adhesive tape Technical Data Raw material Roll width Roll length Carton Pallet Polyethylene adhesive tape 2 cm 20 m 30 pcs. 80 cartons The adhesive coating consists of solvent and emollient-free acrylate. Double-sided blue adhesive tape, used for sticking down rolls of fibrous lining and Roof Sheathing. 19

2007 2007 E Thermofloc/Feistritz/Drau Ref._EN: 01/01/2007 Your THERMOFLOC Partner: Peter Seppele Ges.m.b.H. Bahnhofstraße 79 A-9710 Feistritz/Drau Tel: +43(0)4245-6201 Fax: +43(0)4245-6336 20 office@thermofloc.com I n s u l a t i o n e x p e r t i n f o r m a t i o n : www.thermofloc.com

T H E R MOF L O C Insulation made of cellulose fibre : : h o t p a p e r f o r e n e r g y - s a v e r s! : : t h e t r e n d t o w a r d s i n t e l l i g e n t i n s u l a t i o n! : : R o o f i n s u l a t i o n : : W a l l i n s u l a t i o n 100% Cellulose : : F l o o r i n s u l a t i o n 21