Infrared Thermometer Model: and

Similar documents
Model DIT-516/517: OPERATING MANUAL

GS-IR 8816 Series Infrared Thermometer

63/66/68. Infrared Thermometers. Users Manual

IR-712 IR-712-EUR 12:1 Infrared Thermometer. IR-720 IR-720-EUR 20:1 Infrared Thermometer. IR-730 IR-730-EUR 30:1 Infrared Thermometer.

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

IR-712 IR-720 IR-730

Introduction Cautions

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Noncontact Thermometer

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

566/568. Infrared Thermometers. Getting Started

IR-750. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok. 50:1 IR Thermometer with memory

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

INFRARED THERMOMETER TM0819

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

Instruction Manual SEFRAM Thermal Camera

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

InfraRed Thermometer with Laser Pointer

INFRARED THERMOMETER Model : TM-959

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

INSTRUCTION MANUAL Fax: (503)

Today s Weather 24 Hour Forecaster

INSTRUCTION MANUAL DTH Fax: (503)

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Dual laser + type K thermometer INFRARED THERMOMETER

INSTRUCTION MANUAL INF Fax: (503)

IT Series Infrared thermometer Using manual

Manual Dew point scanner PCE-DPT 1

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

Ground Penetrating Radar & By Mike Kelty Western Technologies Inc.

Emissivity: Understanding the difference between apparent and actual infrared temperatures

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL

optris LaserSight Operators manual

Superconductivity. Never store liquid nitrogen in a container with a tight fitting lid.

Data Sheet. Infra-red Temperature Measurement

Unit 11: Temperature and heat

User s Guide. Shown with Built-in Laser Sighting. OS531, OS532, OS533, OS534 OMEGASCOPE Handheld Infrared Thermometer

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Electromagnetism Review Sheet

Operating instructions Infrared temperature sensor TW20xx TW21xx

Electricity. Year 10 Science

Introduction to Blackbody Sources

Question Bank. Electric Energy, Power and Household Circuits

Thermometer Line. today s laboratory and field

ICSE Board Class IX Physics Paper 1

Heat and Temperature

Infrared Hand-Held Thermometers

Basic Electricity. Chapter 2. Al Penney VO1NO

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP

Electricity and Electromagnetism SOL review Scan for a brief video. A. Law of electric charges.

ICSE Board Class IX Physics Paper 5

1. Electrostatic Lab [1]

Emissivity and Remote Sensing

Downloaded from

Infrared Sensors. Operators manual thermometer CSL-SF50 / CSLM-2HSF300

Part Number Range Accuracy Printing WP * Probe Special User LDC with Page Logging included Feature Cal Backlight

One-Year Limited Warranty

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Peltier Application Note

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

Soft clean eraser Soft pencil (type B or HB is recommended)

CONDUCTORS, INSULATORS, AND ELECTRON FLOW

Infrared Hand-Held Thermometers

Quick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20

High Resolution High Sensitivity SDR Super Wide Dynamic Camera

Non contact temperature measurement

PHOS 15 LED PROJECTOR

SECONDARY SCHOOLS ANNUAL EXAMINATIONS 2005 Educational Assessment Unit Education Division. FORM 4 PHYSICS Time: 1 hr. 30 min.

WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

What is the maximum distance I can have the remote sensors from the display?

Critical parameters of

Determination of freezing points of pure substances with Cobra4 TEC

Emissivity and Remote Sensing

New! 2010 Model. Model No

Thermodynamics. We can summarize the four laws of thermodynamics as follows:

Electric Charges & Current. Chapter 12. Types of electric charge

WW12E, WW08E, WW06E ±5%, ±1% Thick film low ohm chip resistors Size 1206, 0805, 0603 RoHS Exemption free and Halogen free

Infrared Temperature Calibration 101 Using the right tool means better work and more productivity

EXPERIMENT ET: ENERGY TRANSFORMATION & SPECIFIC HEAT

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level

Static Electricity. Electric Field. the net accumulation of electric charges on an object

WW12C, WW08C, WW06C, WW04C, WW02C. Low ohm chip resistors ( power ) Size 1206, 0805, 0603, 0402, 0201

B Left-hand case side (x1) F

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT


Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Cambridge International Examinations Cambridge Ordinary Level

Transcription:

Infrared Thermometer Model: 72-820 and 72-823 1

IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. Please operate according to this manual, otherwise the protection provided by the device will be impaired or fail. Do not point laser directly in your eyes or indirectly off reflective surfaces. Check the condition before using. If you find any cracking, breakage, damage or abnormality, or you consider the device broken, stop using the device immediately Do not use the Thermometer if it operates abnormally. Protection may be impaired. When in doubt, have the Thermometer serviced. Do not operate the Thermometer around explosive gas, vapor, or dust. To avoid a burn hazard, remember that highly reflective objects will often result in lower than actual temterature measurements. To avoid damaging the thermometer or the equipment under test protect them from the following: EMF (electro-magnetic fields) from arc welders, induction heaters, etc. Static electricity. Thermal shock (caused by large or abrupt ambient temperature changes allow 30 minutes for the Thermometer to stabilize before use). Do not leave the Thermometer on or near objects of high temperature. Replace the batteries as soon as the low battery indicator appears on the display. Remove dead batteries from the Thermometer or if it is not going to be used for a long time. Never mix old and new batteries together, or different types of batteries. Never dispose of batteries in a fire, or attempt to recharge ordinary batteries. Before replacing the battery, turn off the Thermometer and disconnect all the test probes. To prolong battery life turn off the Thermometer after use. WHAT S INCLUDED Infrared Thermometer with laser sighting. 9V 6F22 Alkaline Battery (included) Instruction manual FEATURES Single-spot laser sighting. Intelligent USB power input (does not charge internal battery). Backlit display - Two level white/colour (when using USB power, this feature will be on automatically). Current temperature plus MIN, MAX, DIF, AVG temperature readings. Easy emissivity selector. Trigger lock. Celsius and Fahrenheit temperature measurement. Tripod mount. 2

Display The primary temperature display reports the current or last IR temperature read until the 8-second hold time elapses. The secondary temperature display reports a choice of maximum, minimum, difference between maximum and minimum temperature or average value. You can toggle through the maximum, minimum, difference and average IR temperatures anytime the display is on. The MAX, MIN, DIF and AV temperatures are constantly calculated and updated when the trigger is pressed. After the trigger is released, the MAX, MIN, DIF and AV temperatures are held for 8 seconds. Laser on symbol HOLDSCAN o C / o F A B C D Scan or hold Celcuis / Fahrenheit Primary temperature Display Secondary temperature Display Emissivity LO, MED, HI Temperature values for the MAX, MIN, DIF, AVG Low Battery symbol. Appears when the battery charge is <4.5V. After connecting the USB cable, the Thermometer automatically selects USB power supply and two levels white colour backlit display will be on. Note: The USB connection does not charge the internal battery. It is for external power only for when the Thermometer is in use over extended periods. 3

Button operation. Press SET to enter set up mode stepping through Emissivity set up, trigger lock and switching o C/ o F set up. Press to turn on the display backlight. When Thermometer enters user set up mode use to select a further option. Press MODE button to toggle between MAX, MIN, DIF, and AVG options. Press MODE to turn the Thermometer on again and displays the last measurement result. OPERATION FUNCTION Press to turn on laser target function When * Thermometer enters user set up mode use to select a further option. Infrared thermometers measure the surface temperature of an opaque object. The Thermometer s optics sense infrared energy, which is collected and focused onto a detector. The Thermometer s electronics then translate the information into a displayed temperature reading which appears on the display. The laser is used for aiming purposes only. The Thermometer turns on when you press the trigger. The Thermometer turns off when no activity is detected for 8 seconds. To measure temperature, aim the Thermometer at the target, pull and hold the trigger. Release the trigger to hold a temperature reading. To find a hot or cold spot, aim the Thermometer outside the target area. Then, slowly scan across the area with an up and down motion until you locate the hot or cold spot. Distance and target spot size As the distance (D) from the target being measured increases, the spot size (S) of the area measured by the unit becomes larger. The spot size indicates 90% encircled energy. The maximum D:S is obtained when the Thermometer is 600mm (60 in) from the target resulting in a spot size of 20mm (2 in). Make sure that the target is larger than the spot size. 4

Emissivity Emissivity describes the energy-emitting characteristics of materials. Most organic materials and painted or oxidized surfaces have an emissivity of about 0.95. If possible, to compensate for inaccurate readings that may result from measuring shiny metal surfaces, cover the surface to be measured with masking tape or flat black paint (<150 o C / 302 o F) and use the high emissivity setting. Allow time for the tape or paint to reach the same temperatures as the surface beneath it. Measure the temperature of the tape or painted surface. If you cannot use paint or use tape, then you could improve the accuracy of your measurements with the emissivity selector. Even with emissivity selector, it can be difficult to get a completely accurate infrared measurement of a target with a shiny or metallic surface. The Thermometer allows you to adjust the unit s emissivity for the type of surface. To adjust values for emissivity (see table below): 1. Press SET to select emissivity set up, icon E on the display will flash. The Thermometer steps through emissivity set up, trigger lock and switching o C / o F. 2. Press to increase the value by 0.01 or press and hold to access quick setting. The maximum value is 1.00. 3. Press to decrease the value by 0.0 or press and hold to access quick setting. The minimum value is 0.10. Measure Surface (metals) 5 Switch Setting Aluminium oxydised 0.2-0.4 Alloy A3003 oxydised 0.3 Alloy A3003 roughened 0.1-0.3 Burnished Brass 0.3 Oxidised Brass 0.5 Copper oxydised 0.4-0.8 Electrical terminal blocks 0.6 Haynes alloy 0.3-0.8 Inconel oxydised 0.7-0.95 Inconel sandblasted 0.3-0.6 Inconel electropolished 0.15 Cast Iron oxydised 0.6-0.95 Cast Iron clean 0.2 Cast Iron molten 0.2-0.3 Wrought Iron dull 0.9 Lead rough cast 0.4 Lead oxydised 0.2-0.6 Molydbenum oxydised 0.2-0.6 Nickel oxydised 0.2-0.5 Platinum black 0.9 Steel cold rolled 0.7-0.9 Steel ground sheet 0.4-0.6 Steel polished sheet 0.1 Iron oxydised 0.5-0.9 Iron rusted 0.5-0.7 Zinc oxydised 0.1

Measure Surface (non-metals) 6 Switch Setting Asbestos 0.95 Asphalt 0.95 Basalt 0.7 Carbon clean 0.8-0.9 Graphite 0.7-0.8 Carborundum 0.9 Ceramic 0.95 Clay 0.95 Concrete 0.95 Cloth 0.95 Plate glass 0.85 Gravel 0.95 Gypsum 0.8-0.95 Ice 0.98 Limestone 0.98 Paper (any colour) 0.95 Opaque plastic 0.95 Soil 0.9-0.98 Water 0.93 Wood (natural) 0.9-0.95 Trigger Lock Press SET and when lock icon displays select to set on or off. When the trigger is locked, the Thermometer will provide continuous measurement. There is no need to pull the trigger. When the trigger is unlocked, the user must pull the trigger for measurement. When the trigger is released, the Thermometer will hold the measurement result automatically. HOLD appears in the display until the trigger is pulled again. Temperature units Press SET to enter centigrade or fahrenheit mode then select to set selection. OPERATION EXAMPLES Testing Contactors Press SET to select emissivity. Press / to select relatively low emissivity for bright contacts, or 0.7 mid level for darkened contacts. Press MODE to select MAX. Measure line and load side of one pole without releasing trigger. A temperature difference between the line and load sides of a pole indicate increased resistance of one point and a contactor may be failing. Testing Enclosed Relays Press SET and then press / to set emissivity to relatively low for uninsulated connectors or relatively high for plastic encased relays or for bakelite enclosed relays or insulated connectors. Press MODE to select MAX. Start to scan. Measure the relay casing, looking for hot spots.

Testing Fuses and Bus Connectors Press SET and then press / to set emissivity to relatively high for paper covered fuse body or insulated connections. Press MODE to select MAX. Scan the paper covered length of fuse. Without releasing the trigger, scan each fuse. Unequal temperatures between fuses may indicate voltage or amperage imbalance. Press SET and then press / to set emissivity to relatively low, for metal fuses and caps and insulated bus connections. Testing Electrical Connections Press SET and then press / to set emissivity to relatively low for uninsulated connectors or buss connections or relatively high for insulated connections. Scan the conductor, moving toward direction of electrical connector. Note: conductors are typically smaller than the Thermometers spot size. If the spot size is bigger than the connector the reading is the average within the spot. Scanning walls for air leaks or insulation deficiencies Turn off heating, cooling, and blower. Press SET to select emissivity. Press / to select emissivity relatively high for painted surfaces or window surfaces. Press MODE to select MIN when opposite side of wall is at lower temperature and or select MAX when opposite side of wall is at higher temperature. Measure an interior partition wall surface temperature. Do not release the trigger. Record this temperature as your baseline (or benchmark) for a perfectly insulated wall. Face the wall to be scanned. Stand 1.5m away to scan a 5cm spot on the wall. Scan horizontal rows of wall from top to bottom, or horizontal rows of ceiling from wall to wall. Look for greatest deviations from baseline temperature to identify problems. This completes the insulation test scan. Checking Hydronic radiant heat applications Radiant heat tubes in the floor will normally run parallel to the outside walls. Starting at the floor wall juncture, scan parallel to the wall while moving into the room away from the wall. Parallel to the outside wall you should find parallel isothermal rows indicating the location of heat tubes below the surface. Perpendicular to the outside wall, you should find rising and falling temperatures at equal distances. High temperatures indicate you are scanning a heat tube beneath the floor surface, low falling temperatures indicate a space between the heat tubes. Measuring Grille or Diffuser Discharge Temperature Press SET and then press / to select relatively high emissivity. Aim the Thermometer at the discharge air grille, register, or diffuser. Measure discharge temperature. Release trigger to freeze the temperature reading for 8 seconds and record this temperature. Grille, register, or diffuser temperature should be equivalent to discharge temperature at the air handler. 7

MAINTENANCE Changing the battery To install or change the 9V battery, open the battery compartment. Replace only with the same type of battery. Cleaning the lens Blow off loose particles using clean compressed air. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water. Cleaning the casing Wipe using a damp cloth or sponge. Do not use solvents as these may damage the casing. Do not immerse in water. SPECIFICATIONS Infrared Measurement Range (72-820) 18 o C to 550 o C (0 o F to 1022 o F) Measurement Range (72-823) -32 o C to 650 o C (-25 o F to 1200 o F) Spectral Range 8 to 14 microns Accuracy 1.8% or (1.8 o C/4 o F) Repeatability Response Time (95%) 0.5% of reading or 1 o C/2 o F 250ms Distance to Spot (72-820) 12:1 Distance to Spot (72-823) 20:1 Emissivity adjustment 0.10~1.00 Display resolution ±0.1 o C (0.1 o F) Laser Sighting Power Power Supply Power consumption Weight Single point laser Class 2 Output <1mV, wavelength 630 to 670mm 6F22 9V Battery over 30hrs (alkaline) or over 10hrs (gp) 0.322kg INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT These symbols indicate that separate collection of Waste Electrical and Electronic Equipment (WEEE) or waste batteries is required. Do not dispose of these items with general household waste. Separate for the treatment, recovery and recycling of the materials used. Waste batteries can be returned to any waste battery recycling point which are provided by most battery retailers. Contact your local authority for details of the battery and WEEE recycling schemes available in your area. Made in China. PR2 9PP 8 Man Rev 1.0