Critical clearing time evaluation of Nigerian 330kV transmission system

Similar documents
ECE 422/522 Power System Operations & Planning/Power Systems Analysis II : 7 - Transient Stability

Enhancement of transient stability analysis of multimachine power system

Gafari A. Adepoju*, Muhammed A. Tijani **, Mufutau A. Sanusi**, Dauda O. Olatunji **

EVALUATION OF THE IMPACT OF POWER SECTOR REFORM ON THE NIGERIA POWER SYSTEM TRANSIENT STABILITY

1. Introduction. Keywords Transient Stability Analysis, Power System, Swing Equation, Three-Phase Fault, Fault Clearing Time

Power System Stability and Control. Dr. B. Kalyan Kumar, Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India

Transient Stability Analysis of Single Machine Infinite Bus System by Numerical Methods

SCHOOL OF ELECTRICAL, MECHANICAL AND MECHATRONIC SYSTEMS. Transient Stability LECTURE NOTES SPRING SEMESTER, 2008

POWER SYSTEM STABILITY

Module 6 : Preventive, Emergency and Restorative Control. Lecture 27 : Normal and Alert State in a Power System. Objectives

B.E. / B.Tech. Degree Examination, April / May 2010 Sixth Semester. Electrical and Electronics Engineering. EE 1352 Power System Analysis

ECE 585 Power System Stability

A Power System Dynamic Simulation Program Using MATLAB/ Simulink

Chapter 9: Transient Stability

Self-Tuning Control for Synchronous Machine Stabilization

11.1 Power System Stability Overview

KINGS COLLEGE OF ENGINEERING Punalkulam

Comparative Study of Synchronous Machine, Model 1.0 and Model 1.1 in Transient Stability Studies with and without PSS

Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics (Part 2)

A Model for Assessment of Power System Outages on Nigerian Transmission Network.

Reliability of Bulk Power Systems (cont d)

ECE 422 Power System Operations & Planning 7 Transient Stability

A Computer Application for Power System Control Studies

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous)

EE2351 POWER SYSTEM ANALYSIS UNIT I: INTRODUCTION

Incorporation of Asynchronous Generators as PQ Model in Load Flow Analysis for Power Systems with Wind Generation

Transient stability improvement by using PSS and increasing inertia of synchronous machine

IJSER. 1. Introduction

Power Angle & Time Domain Plots 1.0 The power-angle curves

PMU-Based Power System Real-Time Stability Monitoring. Chen-Ching Liu Boeing Distinguished Professor Director, ESI Center

QUESTION BANK ENGINEERS ACADEMY. Power Systems Power System Stability 1

Minimax Approximation Synthesis in PSS Design by Embedding

DESIGNING POWER SYSTEM STABILIZER WITH PID CONTROLLER

Control Lyapunov Functions for Controllable Series Devices

AN EVOLUTIONARY PROGRAMMING APPROACH TO OPTIMIZE SYNCHRONOUS GENERATOR INPUT POWER USING AREA-BASED TRANSIENT STABILITY INDEXES

Examples of Applications of Potential Functions in Problem Solving (Web Appendix to the Paper)

Module 3 : Sequence Components and Fault Analysis

1 Unified Power Flow Controller (UPFC)

7. Transient stability

Computer Simulation of Power Deviation, Admittance Distance, Coherency Indices, and Dynamic Equivalents for Electric Power Systems

EE 451 Power System Stability

Study of Transient Stability with Static Synchronous Series Compensator for an SMIB

SSSC Modeling and Damping Controller Design for Damping Low Frequency Oscillations

TRANSIENT STABILITY ANALYSIS ON AHTS VESSEL ELECTRICAL SYSTEM USING DYNAMIC POSITIONING SYSTEM

SPEED-GRADIENT-BASED CONTROL OF POWER NETWORK: CASE STUDY

Research Paper ANALYSIS OF POWER SYSTEM STABILITY FOR MULTIMACHINE SYSTEM D. Sabapathi a and Dr. R. Anita b

CHAPTER 3 MATHEMATICAL MODELING OF HYDEL AND STEAM POWER SYSTEMS CONSIDERING GT DYNAMICS

Transient Stability Assessment and Enhancement Using TCSC with Fuzzy Logic Controller

POWER SYSTEM DYNAMIC SECURITY ASSESSMENT CLASSICAL TO MODERN APPROACH

Unified Power Flow Controller (UPFC) Based Damping Controllers for Damping Low Frequency Oscillations in a Power System

COMPARISON OF DAMPING PERFORMANCE OF CONVENTIONAL AND NEURO FUZZY BASED POWER SYSTEM STABILIZERS APPLIED IN MULTI MACHINE POWER SYSTEMS

Static and Transient Voltage Stability Assessment of Power System by Proper Placement of UPFC with POD Controller

Modeling of Hydraulic Turbine and Governor for Dynamic Studies of HPP

Multiple Swing Out-of-Step Relaying

DAMPING OF SUBSYNCHRONOUS MODES OF OSCILLATIONS

Impact of Model Detail of Synchronous Machines on Real-time Transient Stability Assessment

FAULT ANALYSIS FOR CIRCUIT BREAKERS RATINGS DETERMINATION ON NIGERIAN 330kv TRANSMISSION GRID

The Effects of Machine Components on Bifurcation and Chaos as Applied to Multimachine System

Reactive Power Compensation in Nigeria Electricity Grid Using Static Synchronous Compensator (STATCOM)

SSC-JE EE POWER SYSTEMS: GENERATION, TRANSMISSION & DISTRIBUTION SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL

WIDE AREA CONTROL THROUGH AGGREGATION OF POWER SYSTEMS

POWER SYSTEM STABILITY AND CONTROL

Effect of Inertia Constant on Generator Frequency and Rotor Angle

Transient Stability Improvement of Multi-machine Power System Using Fuzzy Controlled TCSC

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II : 8 - Voltage Stability

Dynamic Behavior of Three phase Inductions Motors as Loads in an Electric Power System with Distributed Generation, a Case of Study.

The Mathematical Model of Power System with Static Var Compensator in Long Transmission Line

ECEN 667 Power System Stability Lecture 15: PIDs, Governors, Transient Stability Solutions

System Stability of Synchronous Machine with Small Signal Representation including Rotor Circuit Dynamics

Mitigation of Distributed Generation Impact on Protective Devices in a Distribution Network by Superconducting Fault Current Limiter *

Robust Tuning of Power System Stabilizers Using Coefficient Diagram Method

EE2351 POWER SYSTEM OPERATION AND CONTROL UNIT I THE POWER SYSTEM AN OVERVIEW AND MODELLING PART A

Fault Location in Distribution Feeders with Distributed Generation using Positive Sequence Apparent Impedance

EFFECTS OF EHV POWER CIRCUIT BREAKER RECLOSING ON POWER SYSTEM STABILITY

Predicting, controlling and damping inter-area mode oscillations in Power Systems including Wind Parks

REAL-TIME TRANSIENT STABILITY ASSESSMENT

Improving Transient Stability of Multi-Machine AC/DC Systems via Energy-Function Method

A COMPUTER PROGRAM FOR SHORT CIRCUIT ANALYSIS OF ELECTRIC POWER SYSTEMS

Final Exam, Second Semester: 2015/2016 Electrical Engineering Department

The Mathematical Model of Power System with Thyristor Controlled Series Capacitor in Long Transmission Line

CURENT Course Power System Coherency and Model Reduction

DESIGN OF POWER SYSTEM STABILIZER USING FUZZY BASED SLIDING MODE CONTROL TECHNIQUE

Power Grid Partitioning: Static and Dynamic Approaches

Improving Transient Stability of a Multi-Machine Power Network Using FACTS Devices and Nonlinear Controller Tuned by PSO

New criteria for Voltage Stability evaluation in interconnected power system

Mitigating Subsynchronous resonance torques using dynamic braking resistor S. Helmy and Amged S. El-Wakeel M. Abdel Rahman and M. A. L.

Power System Stability GENERATOR CONTROL AND PROTECTION

Minimization of Shaft Torsional Oscillations by Fuzzy Controlled Braking Resistor Considering Communication Delay

Mathematical Model of a Synchronous Machine under Complicated Fault Conditions

Performance Of Power System Stabilizerusing Fuzzy Logic Controller

Computer Applications in Electrical Engineering

IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 19, NO. 2, MAY Definition and Classification of Power System Stability

DYNAMIC RESPONSE OF A GROUP OF SYNCHRONOUS GENERATORS FOLLOWING DISTURBANCES IN DISTRIBUTION GRID

Design of PSS and SVC Controller Using PSO Algorithm to Enhancing Power System Stability

Aldi Mucka Tonin Dodani Marjela Qemali Rajmonda Bualoti Polytechnic University of Tirana, Faculty of Electric Engineering, Republic of Albania

URTDSM Initiative in India and Controlled Islanding using PMU Measurements

Transient Stability Analysis with PowerWorld Simulator

A PRACTICAL EXPERIENCE ABOUT DYNAMIC PERFORMANCE AND STABILITY IMPROVEMENT OF SYNCHRONOUS GENERATORS

A STUDY OF THE EIGENVALUE ANALYSIS CAPABILITIES OF POWER SYSTEM DYNAMICS SIMULATION SOFTWARE

Mathematical Modelling of an 3 Phase Induction Motor Using MATLAB/Simulink

Transcription:

American Journal of Electrical Power and Energy Systems 2013; 2(6): 123-128 Published online October 20, 2013 (http://www.sciencepublishinggroup.com/j/epes) doi: 10.11648/j.epes.20130206.11 Critical clearing time evaluation of Nigerian 330kV transmission system Adepoju Gafari Abiola 1, Tijani Muhammed Adekilekun 2 1 Electronic and Electrical Engineering Department, LAUTECH, Ogbomoso, Nigeria 2 Electrical and Electronics Engineering Department, Federal Polytechnic, Ede, Nigeria Email address: agafar@justice.com (A. Gafari), muhammedtijani@gmail.com (T. Muhammed) To cite this article: Adepoju Gafari Abiola, Tijani Muhammed Adekilekun. Critical Clearing Time Evaluation of Nigerian 330kV Transmission System. American Journal of Electrical Power and Energy Systems. Vol. 2, No. 6, 2013, pp. 123-128. doi: 10.11648/j.epes.20130206.11 Abstract: Critical Clearing Time (CCT) is the largest possible time for which a power system is allowed to remain in fault condition without losing stability. Appropriate CCTs settings of protective equipments on power system greatly determine the reliability of power supply. This paper determines the CCTs for all the transmission lines in the Nigerian 24-bus, 39-lines 330kV transmission system. The Transient Stability Analysis (TSA) program adopted used the method of partitioned approach with explicit integration method. The result of TSA was considered satisfactory since about 87% of the values obtained fall within acceptable international range. It was concluded that the determination of appropriate CCTs for the Nigerian power system will enhance the operation of the power system by limiting effects of faults on the power system. Keywords: Power System, Transient Stability Analysis, Critical Clearing Time 1. Introduction The Nigerian 330kV transmission network links the generating stations and distribution system. Interruptions in this network hinder the flow of power to the load. The cost of losing synchronism through transient instability is extremely high [1]. The quality of electricity supply is measured, amongst other factors, by the ability of the power system to clear faults before they cause damage to the power system equipments. The time at which fault is cleared before it causes damage on the power system is known as Critical Clearing Time (CCT). CCT is the largest possible time for which a power system can remain in fault condition without losing stability once the fault is cleared [2, 3, 4]. Constant faults on Nigerian power system have had adverse effects on the Nigerian economy and its citizenry. The yearnings and aspirations of the Nigerians for constant supply of electricity can partly be met if Nigerian 330kV National Grid is operated to clear faults before damages are caused by the faults given adequate generation, transmission and distribution facilities. Hence, the need to determine appropriate CCT for the circuit breakers on the power system. CCT is determined through the performance of Transient Stability Analysis (TSA) of the power system. TSA is the evaluation of the stability of a power system when there is large and sudden disturbance on the power system. This disturbance can be a fault which includes; transmission line short-circuit, loss of generator, load or a part of the transmission network and gain of load [5]. The generators in the power system respond to the occurrence of these disturbances with large swinging of their rotor angles. Initial operating conditions and the severity of the disturbance determine the stability of a power system [6]. Transient stability problems are concerned mainly with the behaviors of synchronous machines in power system after they have been perturbed. When a fault occurs on the power system, an imbalance is created between the generator output and the load. The rotor angle of the machine accelerates beyond the synchronous speed which is the reference speed, for a time greater than zero. When this happens, the machine is said to be swinging and two possibilities are identified when the rotor angle is plotted as a function of time [7]. i. The rotor angle swings and eventually settles at a new angle. The system is said to be stable i.e. in synchronism. ii. The rotor angle swings and the relative rotor angle diverge as time increases. This condition is considered unstable i.e. losing synchronism. The single line diagram of the Nigerian 24-bus, 330kV transmission system considered is shown in Figure 1 [8].

124 Adepoju Gafari Abiola et al.: Critical Clearing Time Evaluation of Nigerian 330kV Transmission System and a small change in speed. The voltage behind the transient reactance is determined from the following equation (1) [7, 9, 10]. (1) Where = Voltage behind transient reactance. = Machine terminal voltage = direct axis transient reactance. = Machine terminal current The rotor mechanical dynamics are represented by the following equations [3, 11].. 2 (2) Figure 1. Nigerian 24 Bus 330kV National Grid [8]. 2. Methodology The initiation of fault and its removal by circuit breakers in a power system is considered that the system is going through a change in system configuration in three stages: pre-fault, fault and post-fault stages. The dynamics of the power system during fault and post-fault periods are nonlinear and the exact solution is too complex. In order to reduce the complexity of the transient stability analysis, the following simplified assumptions are made [7]; i. Every synchronous machine in the power system is modeled by a constant voltage source at the back of direct axis transient reactance. ii. The governor s actions for the automatic control generation are neglected and the input powers are assumed to remain constant. iii. Using the pre-fault bus voltages, all loads are converted to equivalent admittances to ground and are assumed to remain constant. iv. Damping or asynchronous powers are ignored. v. The mechanical rotor angle of each machine coincides with the angle of the voltage behind the machine reactance. vi. Machines belonging to the same station swing together and are said to be coherent. A group of coherent machines is represented by one equivalent machine. In transient stability studies, particularly those involving short periods of analysis in the order of a second or less, a synchronous machine can be represented by a voltage source behind transient reactance that is constant in magnitude but changes its angular position [9]. This representation neglects the effects of saliency and assumes a constant flux linkages (3) Where H = per unit Inertial Constant D = Damping coefficient = rotor angle of the generator δ = angular speed of the generator = Mechanical Torque Input = Electrical Torque output Numerical integration techniques are used to solve the swing equation for multimachine stability problems. The Modified Euler s method is used to compute machine power angles and speeds in this research work. The real electrical power output of each machine is computed by the following equations., 1,2,,# (4) &/0% %% & %%' & %cos +, & - - &. (5) The above equations (1) to (5) are very crucial to transient stability studies because they are used to calculate the output power of each machine in the power system. The individual models of the generators and the system load given by the differential and algebraic equations have been stated. Together, these equations form a complete mathematical model of the system, which are solved numerically to simulate system behaviors. To develop a power system dynamic simulation, the equations used to model the different elements are collected together to form: [6, 10, 12]. (i) A set of differential equations 12 3+1,4. (6) That describes the system dynamics, primarily contributed by the generating units and the dynamic loads. (ii) A set of algebraic equations 06+1,4. (7) That describes the network, static loads and the algebraic

American Journal of Electrical Power and Energy Systems 2013; 2(6): 123-128 125 equations of generators. The solutions of these two sets of equations define the electromechanical state of the power system at any instant in time. Equations (6) and (7) can be solved using either a Partition Solution method or a Simultaneous Solution method. In the partitioned solution method, the differential equations are solved using a standard explicit numerical integration method with algebraic equation (7) being solved separately at each time step. The simultaneous solution uses implicit integration methods to convert the differential equations of (6) into a set of algebraic equations which are combined with the algebraic network equations of (7) to be solved as one set of simultaneous algebraic equations [6, 11, 12]. stability program [6]. The transient stability program adopted in this research work uses the method of partitioned approach with explicit integration method. The advantages of the method include programming flexibility and simplicity, reliability and robustness. Figure 2 shows the flowchart for the transient stability solution using the Modified Euler s method [13]. 3. Results and Discussion The Nigerian power system considered is a 24 bus system which has seven (7) generators and thirty-nine (39) transmission lines. Three phase fault was simulated on each bus and different lines removed to determine the stability or otherwise of the power system. The critical clearing time, which is a measure of the stability, was determined by varying the fault clearing times. At any time greater than the critical clearing time, the system becomes unstable. The stability and instability of the power system at a given fault is determined by the behavior of the generators. If the rotor Angles of the generators diverge, the system is unstable and if otherwise, the system is stable. Figures 3, and 4 show the behaviors of the generators, with generator 7 (Egbin) as reference, on the power system when three-phase faults occur on Buses 3 (AJA) and 9 (AYEDE) and lines L1 (AJA to EGBIN) and L20 (AYEDE to OSOGBO) are removed respectively for faults cleared at the critical clearing times. The generators swing together to show stable equilibrium. Figures 5, and 6 show the behaviors of the generators, with generator 7 as reference, on the power system when faults occur on Buses 3 (AJA) and Figure 2. Modified Euler s Method Applied to Transient Stability sstability Problems [13] The partitioned approach with explicit integration method is the traditional approach used widely in production grade Figure 3. Generator rotor angle behaviour for fault at bus3 and line L1 removed at 0.01s critical clearing time (stable condition)

126 Adepoju Gafari Abiola et al.: Critical Clearing Time Evaluation of Nigerian 330kV Transmission System Figure 4. Generator rotor angle behaviour for fault at bus 3 and line L1 removed at 0.05s critical clearing time (unstable condition) Figure 5. Generator rotor angle behaviour for fault at bus 3 and line L1 removed at 0.01s critical clearing time (stable condition) Figure 6. Generator rotor angle behaviour for fault at bus 3 and line L1 removed at 0.08s critical clearing time (unstable condition) 9 (AYEDE) and lines L1 (AJA to EGBIN) and L20 (AYEDE to OSOGBO) are removed respectively for faults cleared at times greater than the critical clearing times. It was observed that the rotor angle diverges and hence the system is unstable. Figures 3 and 4 show that the generators on the Nigerian 330kV Transmission Grid System are grouped into two. Buses 2 (Delta), 18 (JebbaG) and 21 (Kainji) formed the first group while buses 11 (Afam), 23 (Shiroro) and 24 (Sapele) are in the second group. Machines in each group swing together with respect to the reference machine (Bus 1). The system is stable from these figures. Figures 5 and 6 show the angular positions of machines for a clearing time greater than the critical clearing time. In these cases, the clearing times increase beyond the critical clearing times and the machines go out of steps as seen in the figures. It is found that the critical clearing time of the fault on Bus 18 (JebbaG) is lower than those of buses 3 (Aja) and 9 (Ayede). This can be interpreted in such a way that faults closer to generating stations must be cleared rapidly than faults on the lines far from the generating stations. Table 1 shows the critical clearing times in milliseconds determined for all the thirty-nine lines on the Nigerian 330kV National Grid. Starting with a clearing time of 0.01seconds, transient stability analysis program is run and if the conditions proved stable, another run is made with a higher value; if the second run showed the system to be unstable, then the clearing time of the first run gives the desired result. If the second run is still stable then more runs are made until the system becomes unstable. In some cases, a lower value of time is tested if 0.01 proved to be unstable. Comparing the results in Table 1 with Table 2 [14] which is a standard Range of typical EHV Relay-Breaker Clearing

American Journal of Electrical Power and Energy Systems 2013; 2(6): 123-128 127 Time, it was observed that all the relay breaker clearing times fall below the normal Critical Clearing Times but 87% fall below the total back-up clearing time as shown in Table 1. 4. Conclusion The transient stability analysis was carried out to determine the critical clearing time for the circuit breakers on the power system. The partitioned solution method with explicit Modified Euler s integration method was used in Table 1. Critical clearing time for faults on Nigerian 330kV transmission system Faulted bus Removed lines Critical clearing time, t cr (milliseconds) 3 L1 20 L2 20 4 L3 20 L4 20 1 L5 20 L6 20 5 L7 20 L8 20 9 L9 60 10 L10 60 6 L11 40 L12 40 2 L13 40 7 L14 20 24 L15 100 14 L16 60 8 L17 40 8 L18 20 L19 20 9 L20 60 15 L21 20 17 L22 60 L23 60 L24 60 11 L25 60 L26 60 12 L27 60 13 L28 100 16 L29 100 18 L30 20 L31 20 23 L32 20 L33 20 21 L34 20 L35 20 20 L36 100 22 L37 100 20 L38 20 L39 20 Table 2. Range of typical EHV relay-breaker clearing time [14] Function Time in cycles Time (milliseconds) Primary relay 0.85 1.25 17 25 Breaker clearing 2.5 50 Total normal clearing time Breaker-failure detection 3.35 3.75 67 75 0.425 1.25 8.5 25 Coordination time 2.5 4.25 50 85 Auxiliary relay 0.425 0.85 8.5 17 Backup breaker clearing 1.75 35 Total backup clearing 8.45 11.85 169 237 solving the transient stability equations. The results of the transient analysis are considered satisfactory since the entire relay breaker clearing times fall below the normal Critical Clearing Times. The system is well protected in the first instant but the protection has to be improved upon so that 100% total back-up clearing will be achieved. It has been demonstrated in this research work that determination of appropriate CCTs for the Nigerian power system will enhance the operation of the system by limiting the effects of faults on the power system. The CCTs for three-phase faults of circuit breakers installed on the Nigerian 330kV Transmission Grid were established which serves as reference data for the use of power system experts and researchers. References [1] O. Anthony, and O. Ameze. Transient stability assessment of the Nigerian 330kV network,. International Journal of Engineering, Vol. 4, Issue 5, pp 357 367, 2011. [2] M.H. Haque, and A.H. Rahim. Determination of first swing stability limit of multimachine power system through taylor series expansion, IEEE Proceedings on Power Application, Vol. 136, No. 6, November 1989, pp. 374 379. [3] B. Boussahoua, and M. Boudour. Critical clearing time evaluation of power system with UPFC by energetic method, Journal of Electrical Systems,Special Issue, No. 1, pp 85 88, 2009. [4] Z. Eleschova, M. Smitkova, and A. Belan. Evaluation of power system transient stability and definition of basic criterion, International Journal of Energy, Issue 1, Vol. 4, pp 9 16, 2019. [5] P. Iyambo, and R. Tzenova. Transient stability analysis of the IEEE 14 test bus electric power system, IEEE Transaction on Power Systems, Vol. 25, No. 3, pp 1 7, 2007. [6] S. Ravi, and S. Siva. Transient stability improvement using UPFC and SVC, ARPN Journal of Engineering and Applied Sciences, Vol. 2, No. 3, pp 28 45, 2007. [7] H. Saadat. Power System Analysis. McGraw-Hill, New York, USA, 1999.

128 Adepoju Gafari Abiola et al.: Critical Clearing Time Evaluation of Nigerian 330kV Transmission System [8] G. Adepoju, O. Komolafe and A. Aborishade. Power flow analysis of the Nigerian transmission system incorporating FACTS controller, International Journal of Applied Science and Technology, Vol. 1, No. 5, pp 186 200, September 2011. [9] G.W. Stagg, and H. El-Abiad. Computer Methods in Power System Analysis. McGraw-Hill, Kogakusha, Tokyo, 1968. [10] X. Wang, S. Yonghua, and I. Malcolm. Modern Power System Analysis. Springer, New York, USA, 2008. [12] J. Machowsky, J. Bialek, S. Robak, and J. Bumby. Power System Dynamics Stability and Control. John Willey & Sons Ltd, Wiltshire, Great Britain, 2008. [13] C.L. Wadhwa. Electrical Power System. John Wiley and Sons, New Delhi, India, 1991. [14] G. Adepoju. Transient stability: a case study of NEPA 330kV transmission grid system. M.Sc, University of Lagos, Akoka, Nigeria, 2000. [11] K. Prabha. Power System Stability and Control. McGraw-Hill, New York, USA, 1994.