Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Similar documents
Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Solid Phase Extraction Method Development Tips and Tricks

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

[ Care and Use Manual ]

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Development for SPE. Ron Majors Senior Chemist, CSD Joan Stevens SPE Application Chemist October 2009

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Determination of Alkaloids in Goldenseal Using Agilent Bond Elut Plexa Solid Phase Extraction Sorbent for Cleanup and HPLC-DAD Analysis

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

Determination of 24 PAHs in Drinking Water

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

LC and LC/MS Column Selection Flow Chart

Sample Prep Options for GC users

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Development of analytical methods for Catecholamines, Metanephrines and related metabolites in urine and plasma matrices

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

EVOLUTE EXPRESS SPE Products. Load-Wash-Elute SPE Products

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

SPE Method Development Tips and Tricks. Group/Presentation Title Agilent Restricted Month ##, 200X

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes Application

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Acclaim Mixed-Mode WCX-1

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Shodex TM ODP2 HP series columns

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

Application of Bio-SPME for the Enrichment of Illicit Phenethylamine and Cathinone Compounds from Biological Samples

Detection of 9-tetrahydrocannabinol ( 9-THC) in human urine by Solid Phase Extraction and HPLC.

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

ProPac WCX-10 Columns

Modernizing the USP Monograph for Acetaminophen

Sample Preparation. Approaches to Automation for SPE

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges

Automated Sample Preparation. Andrew Duggan, PhD Aman Sharma Shimadzu Scientific Australia

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Determination of trace anions in concentrated hydrofluoric acid

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

for Acclaim Mixed-Mode WCX-1

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation

State-of-the-art C18 HPLC Columns

Packings for HPLC. Packings for HPLC

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Sample Preparation Products General Catalogue. Sample Preparation Products General Catalogue

Hints for Strong Ion Exchange Resins

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

HPLC Column Material - Bulk Ware

Characterization of Carbon SPE for the Extraction of Polar Analytes

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Too Polar for Reversed Phase What Do You Do?

Chromatography. Gas Chromatography

High Performance Liquid Chromatography

High Performance Liquid Chromatography

HPLC analysis of VFAs, Furfural and HMF

Application. Introduction. Authors. Abstract. Hydrocarbon Processing

Biochemistry. Biochemical Techniques HPLC

Analysis of Saponins in Spine Date Seed using Agilent ZORBAX Solvent Saver HT (1.8 µm) Columns

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Application Note. Abstract. Authors. Environmental

New Product Update. HPLC Columns

Transcription:

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent reproducibility High recoveries Spherically controlled particles General Description Solid-phase extraction (SPE) is an integral sample preparation technique in the analytical workflow of complex samples. Even with the adoption of highly selective detectors, LC/MS/MS or GC/MS/MS, ion suppression from coeluting impurities can adversely affect quantitative analyses. A clean extract directly correlates to less complicated analysis conditions, longer column life, and more accurate results. SPE is the preferred sample preparation technique over liquid-liquid extraction (LLE), protein precipitation (PPT), or solid-phase microextraction (SPME) because it offers greater flexibility, more reproducible recoveries, reduced solvent cost, more effective cleanup, and automation. SPE sample preparations are used by researchers in the pharmaceutical, forensic, food safety and environmental sector. The Agilent SampliQ WAX polymeric resin is a neutral primary amine modified divinyl benzene polymer (Figure 1). The resin exhibits retention for acidic, neutral and more importantly strongly acidic compounds (for example, sulfonates) that are irreversibly retained on strong anion exchange resins. The pka (~6) of the SampliQ- WAX is more versatile than a strong anion exchange resin, which is always charged (pka > 16). This offers more flexibility since SampliQ-WAX charge or neutrality is based on ph. SampliQ-WAX exhibits both anion exchange and reversed-phase behavior, which equates to easy method development. The weak anion exchange resin is inert to a wide variety of solvents, stable in the ph range 0 to 14, and water-wettable.

R R CH 2 NH 2 Neutral amine functionally Figure 1. WAX resin. Quality Controls The data from our QA testing procedures reflect lot-to-lot resin uniformity. The particle characteristics are carefully controlled and monitored. Spherical polymeric particles are used to ensure homogeneous and reproducible packing. Particle size and distribution are measured by electrozone-sensing analysis. The particle shape is characterized by light microscopy, and the surface area and porosity are determined by nitrogen adsorption. The rigorous size controls provide excellent reproducibility and flow characteristics. Every batch is tested for chromatographic performance and purity. The SampliQ Certificate of Performance (enclosed with each box) indicates the stringent acceptance range and documents each lot within the range. Operational Guidelines With SampliQ-WAX cartridges, the extraction procedure is simple. There are typically five steps in a mixed-mode SPE procedure: 1. Conditioning 2. Load ph ~ 1 2 3. Aqueous solvent wash, ph 4.5 5.0 4. Organic solvent wash 5. Elution with alkaline organic It is imperative to understand the nature of each step in order to best optimize the solvent selection. Figure 2 shows a recommended starting procedure for method development. In this example the volumes shown are for a 60 mg/3 ml cartridge. For various amounts of SPE material, proportionally correcting the volumes should be effective for many applications. The Agilent SampliQ-WAX weak anion polymeric solid phase extraction cartridges are compatible with the aqueous and organic solvents associated with mixed-mode SPE. The cartridges fit into the Agilent vacuum manifolds and any vacuum manifold that accepts Luer tip fittings. 2

Conditioning Step Almost all SPE material uses a water-miscible organic solvent in its first conditioning step to prepare (wet) the resin to receive the sample. Methanol is the most popular conditioning solvent. The next step in the conditioning process is equilibration, which is removal of the methanol with at least five bed volumes of an aqueous solution. Loading Step Samples in complex matrices will require additional preparation prior to loading. Common preparation methods are dilution, ph adjustment, homogenization, centrifugation, and filtration. The prepared sample is usually spiked with an internal standard and loaded onto the cartridge as an aqueous solution. The flow through the cartridge is crucial and should not exceed 1 ml/min. If the flow is too fast, channeling will occur resulting in low recoveries. Vacuum will probably be required, depending on the volume and viscosity of the sample. For the strongest retention of the acids and neutrals, the ph of the loading solution should be approximately 1 to 2. An acidic loading solution maintains a charge on the weak anion exchange resin. Loading volumes for a mixed-mode polymeric SPE resin are synonymous with standard silica bonded material. However, the loading capacity of all polymeric SPE material is greater than silica-based sorbent. A 60-mg bed of polymeric material is therefore comparable to a 200-mg bed of C18 silica sorbent. In general, polymeric SPE material can retain approximately 10% to 15% of its bed volume, whereas silica based sorbents are approximately 5% of its bed volume. Washing (Aqueous) The wash solution should be modified with buffer to a ph of approximately 4.5 for the preferential retention of acids. A minimum volume of five times the bed volume should be used for the wash. The flow through the cartridge should be approximately 1 ml/min. The cartridge should dry for 1 minute at 10 inches Hg to remove as much residual water as possible. Wash (Organic) In many applications, the cleanup of the sample is aided by the selective removal of neutral and basic compounds. However, the methanol eluent can be collected to isolate the neutral molecules if desired. The mixed-mode (weak anion exchange/reversed phased) behavior provides greater flexibility in method design, the ability to fractionate neutral compounds, and cleaner extracts. The cartridge should dry for 1 minute at 10 inches Hg. Elution Step A ph modification is required to elute the target compounds; two ph units (ph > 8) above the pka of the weak anion resin (pka~6) will result in the cleanest extracts. Flow through the cartridge should not exceed 1 ml/min, and a minimum of five times the bed volume should be used for elution. The eluent is collected, evaporated and reconstituted in the initial starting mobile phase. The Agilent SampliQ WAX solid-phase extraction cartridges are compatible with water, acid, basic solvents from ph 0 to 14, and most organic solvents. The cartridges are intended for single use, reconditioning is not recommended. 3

Condition with 1 ml Methanol Equilibrate with 1 ml Water Load 1 ml spiked plasma (dilute 1:1 with buffer) add IS Dry 3 minute Wash with 1 ml 25 mm Sodium Acetate Dry 1 minute Methanol fraction may be collected if basic and neutral compound capture is desired. Wash and Inference removal with 1 ml Methanol Elute 2 1 ml 5% Ammonium Hydroxide/Methanol:ACH (20/80) Dry 1 minute Dry and reconstitute in mobile phase Figure 2. Agilent SampliQ WAX method development process for 60 mg/3 ml cartridge. Performance The SampliQ WAX weak anion polymeric resin provides highly reproducible recoveries for a wide range of acidic compounds following a simple protocol. Optimization of the method may be required to enhance the specificity of the separation and to accommodate the analytical steps to follow. HPLC Analysis Column: Agilent Zorbax Rapid Resolution Eclipse Plus C18, 4.6 150 mm, 5.0 µm (p/n: 959993-906) Mobile phase: A: 20 mm ammonium acetate/water B: 10:90 water: acetonitrile 20 mm ammonium acetate Gradient profile: Time %B 0 2 18 75 18.1 2 Flow rate: 0.8 ml/min Injection volume: 2 µl HPLC: Agilent 1200 HPLC DAD, 230 and 254 nm 4

Table 1 show the compounds used in this study. The compounds are a series of acids (weak to strong) with a range of hydrophobicity. Compound Log P pka Indoprofen 2.77 5.45 Naproxen 4.15 3.18 Diflunisal 4.44 2.9 Indomethacin 4.27 4.5 Ketoprofen 0.97 5.94 2-naphthalenesulfonic acid 0.63 1.29 2 4 3 6 1 5 Figure 3. Chromatographic representation of the acidic and neutral compounds extracted from human plasma by SampliQ WAX: Peak 1. Indoprofen, 2. Naproxen, 3. Diflunisal, 4. Indomethacin, 5. Ketoprofen, 6. 2-napthalenesulfonic acid, 1 ug/ml spiked sample. Exceptional Compound Recovery From Human Plasma with SampliQ WAX 100 90 80 70 60 50 40 30 20 10 0 Indoprofen Naproxen Diflunisal Indomethacin Ketoprofen 2-naphthalenesulfonic acid Figure 4. Exceptional recovery of acidic and neutral compounds from human plasma via SampliQ-WAX, > 90% recoveries and <2.0% RSD, for a 1 ug/ml spiked sample. 5

Conclusion Agilent SampliQ WAX is a weak anion exchange polymeric resin designed for the extraction and concentration of strongly acidic, acidic and neutral compounds. A general protocol can be used to extract strongly acidic, acidic and neutral compounds that range in hydrophobicity. Applications employing WAX polymeric resin can be found in pharmaceutical, forensics, food/flavors and environmental sectors. 30 micron 6 micron Description Unit part no. part no. 30 mg, 1 ml 100/pk 5982-3613 5982-6613 60 mg, 3 ml 50/pk 5982-3636 5982-6636 150 mg, 6 ml 30/pk 5982-3667 5982-6667 96-well plate, WAX, 30 mg, 2 ml 5982-3696 5982-6696 For More Information For more information on our products and services, visit our Web site at www.agilent.com/chem. Author/Contact Joan Stevens is a sample preparation application chemist based at Agilent Technologies, Inc., Wilmington DE, USA. www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 2010 Printed in the USA April 6, 2010 5990-5394EN