EVAPORATIVE CO 2 HEAT TRANSFER MEASUREMENTS FOR COOLING SYSTEMS OF PARTICLE PHYSICS DETECTORS

Similar documents
Evaporative CO 2 cooling for thermal control of scientific equipments. Bart Verlaat (Nikhef/CERN)

EXPERIMENTAL ANALYSIS OF R-134a FLOW CONDENSATION IN A SMOOTH TUBE

Boiling Heat Transfer and Pressure Drop of R1234ze(E) inside a Small-Diameter 2.5 mm Microfin Tube

Experimental investigation on up-flow boiling of R1234yf in aluminum multi-port extruded tubes

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Heat transfer and pressure drop experimentation inside single minichannels

InterPACKICNMM

Characteristics of Flow Boiling Heat Transfer of Sub-Critical CO2 in Mini-Channels With Micro- Fins

FLOW BOILING OF ETHANOL IN SMALL DIAMETER TUBES

DETERMINATION OF R134A S CONVECTIVE HEAT TRANSFER COEFFICIENT IN HORIZONTAL EVAPORATORS HAVING SMOOTH AND CORRUGATED TUBES

AN EXPERIMENTAL INVESTIGATION OF BOILING HEAT CONVECTION WITH RADIAL FLOW IN A FRACTURE

Supercritical Helium Cooling of the LHC Beam Screens

Uncertainty Analysis on Prediction of Heat Transfer Coefficient and Pressure Drop in Heat Exchangers Due to Refrigerant Property Prediction Error

Principles of Food and Bioprocess Engineering (FS 231) Problems on Heat Transfer

Heat Transfer Predictions for Carbon Dioxide in Boiling Through Fundamental Modelling Implementing a Combination of Nusselt Number Correlations

Development of cryogenic silicon detectors for the TOTEM Roman pots

Condensation and Evaporation Characteristics of Flows Inside Three Dimensional Vipertex Enhanced Heat Transfer Tubes

Development of a Mechanically Pumped Two-Phase CO 2 Loop for the AMS-2 Tracker Thermal Control System

Evaporation Heat Transfer Coefficients Of R-446A And R-1234ze(E)

HE II HEAT EXCHANGER TEST UNIT FOR THE LHC INNER TRIPLET

Training period at CERN, Studies on cooling systems. Jean-Francois Seytre. Table of Contents.

CERN, 1211 Geneva 23, Switzerland *Laboratoire des Signaux et Systèmes, UMR 8506 CNRS-Supélec, Gif-sur-Yvette, France

Put sufficient ice cubes into water (1 M) and wait for equilibrium (both exist) (1 M)

Properties of Vapors

Forced Convective Boiling Heat Transfer in Microtubes at Low Mass and Heat Fluxes

EXPERIMENTAL STUDY OF R-134A VAPORIZATION IN MINICHANNELS

Coolant. Circuits Chip

CRYOGENIC CONDUCTION COOLING TEST OF REMOVABLE PANEL MOCK-UP FOR ITER CRYOSTAT THERMAL SHIELD

Onset of Flow Instability in a Rectangular Channel Under Transversely Uniform and Non-uniform Heating

R134a Flow Boiling inside a 4.3 mm ID Microfin Tube

FORCE FED BOILING AND CONDENSATION FOR HIGH HEAT FLUX APPLICATIONS

Performance Characterization of Two Selected Refrigerants in a Flat-Plate Micro-Tube Condenser

Contribution to the study of neon-nitrogen mixtures at low temperatures

FIELD TEST OF WATER-STEAM SEPARATORS FOR THE DSG PROCESS

The Research of Heat Transfer Area for 55/19 Steam Generator

Measurement of the performances of a transparent closed loop two-phase thermosyphon

Heat Transfer of Condensation in Smooth Round Tube from Superheated Vapor

An experimental investigation on condensation of R134a refrigerant in microchannel heat exchanger

N. Lemcoff 1 and S.Wyatt 2. Rensselaer Polytechnic Institute Hartford. Alstom Power

He II Heat transfer through a Corrugated Tube - Test Report

Experimental investigation on saturated critical heat flux of refrigerant R134a at high saturation temperatures

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

Characteristics of CO2 Transcritical Expansion Process

THE METHOD OF THE WORKING FLUID SELECTION FOR ORGANIC RANKINE CYCLE (ORC) SYSTEM WITH VOLUMETRIC EXPANDER. * Corresponding Author ABSTRACT

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM V (ME-51, 52, 53, 54)] QUIZ TEST-1 (Session: )

Helium two-phase flow in a thermosiphon open loop

Measurement of Tritium in Helium

THERMOHYDRAULIC BEHAVIOUR OF HEII IN STRATIFIED CO-CURRENT TWO-PHASE FLOW AT HIGH VAPOR VELOCITIES

(ii) the total kinetic energy of the gas molecules (1 mark) (iii) the total potential energy of the gas molecules (1 mark)

Heat and Mass Transfer Prof. S.P. Sukhatme Department of Mechanical Engineering Indian Institute of Technology, Bombay

THE CERN CRYOGENIC TEST FACILITY FOR THE ATLAS BARREL TOROID MAGNETS

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

PERFORMANCE OF THE ATLAS MUON TRIGGER IN RUN 2

Flow instabilities in a vertical tube reboiler

T718. c Dr. Md. Zahurul Haq (BUET) HX: Energy Balance and LMTD ME 307 (2018) 2/ 21 T793

INTRODUCTION Strained Silicon Monochromator Magnesium Housing Windows for Monochromator Shutter and Collimator Fission Detector HOPG Monochromator

Measurement of the D 0 meson mean life with the LHCb detector

Available online at ScienceDirect. Procedia Engineering 157 (2016 )

1. INTRODUCTION TO REFRIGERATION AND AIR CONDITION

Effect of flow velocity on the process of air-steam condensation in a vertical tube condenser

SEM-2017(03HI MECHANICAL ENGINEERING. Paper II. Please read each of the following instructions carefully before attempting questions.

Estudio del refrigerante R134a en estado bifásico circulando en un tubo horizontal

A 3 Vapor pressure of volatile liquids

a. Key Laboratory of Efficient Utilization of Low and Medium Grade Energy, MOE, Tianjin University, Tianjin , China

Upgrade plans for the ATLAS Forward Calorimeter at the HL-LHC

DYNAMICS OF A LIQUID HELIUM I CRYOSTAT AT THE CANADIAN LIGHT SOURCE. C. Regier1. Canadian Light Source Inc. Saskatoon, SK, S7N 0X4, Canada.

PREDICTION OF TWO-PHASE THERMOSYPHON THROUGHPUT BY SELF DEVELOPED CAE PROGRAM

Axial profiles of heat transfer coefficients in a liquid film evaporator

Innovative Minichannel Condensers and Evaporators for Air Conditioning Equipment

Cryogenic and Electrical Test Results of a 30 M HTS Power Cable

Boiling and Condensation (ME742)

Chapter 1 INTRODUCTION AND BASIC CONCEPTS

Differential Mobility Particle Sizer (Aerosol measurements)

Boiling of R-134a in Horizontal Mini Tube

Heat Exchangers for Condensation and Evaporation Applications Operating in a Low Pressure Atmosphere

Contents. 1 Introduction 4. 2 Methods Results and Discussion 15

Thermochemistry/Calorimetry. Determination of the enthalpy of vaporization of liquids LEC 02. What you need: What you can learn about

Investigation of anomalous heat production in Ni-H systems

Two-Phase Refrigerant Distribution in a Micro- Channel Manifold

Heat and Mass Transfer Unit-1 Conduction

Measurements of temperature on LHC thermal models

THE EFFECT OF LIQUID FILM EVAPORATION ON FLOW BOILING HEAT TRANSFER IN A MICRO TUBE

Vacuum techniques (down to 1 K)

IMPLEMENTATION AND EXPERIENCE WITH LUMINOSITY LEVELLING WITH OFFSET BEAM

Measurement of Conductivity of Liquids

Operation and Performance of the LHCb experiment

THE VERSATILE VSP2: A TOOL FOR ADIABATIC THERMAL ANALYSIS AND VENT SIZING APPLICATIONS

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

Flow pattern identification based on a single-wire capacitance probe

High-Pressure Volumetric Analyzer

3D Simulation of the Plunger Cooling during the Hollow Glass Forming Process Model, Validation and Results

10 minutes reading time is allowed for this paper.

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Superfluid helium heat pipe. P.

Investigation of Heat Transfer on Smooth and Enhanced Tube in Heat Exchanger

HEAT TRANSFER PROFILES OF AN IMPINGING ATOMIZING WATER-AIR MIST JET

Level 7 Post Graduate Diploma in Engineering Heat and mass transfer

Report Liquid Hydrogen Target for the COMPASS Experiment

Droplet behaviour in a Ranque-Hilsch vortex tube

(a) (b) Fig. 1 - The LEP/LHC tunnel map and (b) the CERN accelerator system.

Transcription:

HEFAT21 7 th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics 19-21 July 21 Antalya, Turkey EVAPORATIVE CO 2 HEAT TRANSFER MEASUREMENTS FOR COOLING SYSTEMS OF PARTICLE PHYSICS DETECTORS Colijn A.P.* and Verlaat B. National Institute for Subatomic Physics, Amsterdam, The Netherlands, E-mail: colijn@nikhef.nl ABSTRACT A major challenge in particle physics detectors is to transport the heat developed in their electronics to the outside world. Particle detectors require a minimum of material in order not to disturb accurate measurements of particle trajectories. CO 2 has superior behavior in small diameter - low material tubes, although detailed experimental data are lacking. Understanding the behavior of evaporative CO 2 cooling in small diameter tubing is therefore of large interest for future detector cooling developments. At the Dutch Institute for Subatomic Physics, Nikhef, we are developing an automated CO 2 test set-up able to scan the full phase space of mass fluxes, heat fluxes, vapor quality and temperature. A wide range of tube diameters (.5 to 4mm) will be explored and data will be compared to the available models. In this paper we will present the test setup and the first measurements of heat transfer, pressure drop, and dry-out behavior at room temperature. Lower evaporation temperatures down to -5 C will be explored in a later stage after an upgrade of the research plant. INTRODUCTION The Large Hadron Collider (LHC)[1] at CERN (Geneva) has become operational in the fall of 29. The LHC is a particle accelerator that will collide protons at an energy and intensity that is an order of magnitude higher than ever reached before. With the LHC we may discover much about the behavior of matter at the smallest distances and we may shed a light on how the Universe behaved in its first few seconds. Essential to all potential discoveries are the big detectors that are built around the collision points of the protons. These are the microscopes that look into the collisions in detail. For our research on cooling we focus on the detectors that are closest to the collision point of the proton beams. These detectors, the so-called trackers, have the task to measure accurately within 1 s of micrometers - the positions of the thousands of electrically charged particles that are produced when two protons collide head-on. Nowadays trackers are mostly made of solid state i.e. silicon detectors. These detectors usually consist of active sensor material in combination with readout electronics that are both generating heat. To transport this heat out of the detector a sophisticated cooling system is needed. In addition to the normal design considerations for a cooling system, we are subject to the following additional constraints: Minimize material. The cooling system is inside the volume where particles are traced, very close to the particle accelerator beam line. Any material here will deteriorate the precision of the measurements. Fortunately CO 2 allows for relatively small tube diameters compared to lowpressure evaporation coolers. First of all the viscosity of CO 2 is low. Second, CO 2 has a low dt/dp ratio which means that relatively large pressure drops are allowed without serious temperature gradients due to the change in evaporation pressure. Tolerant to radiation. The cooling system at least the part inside the tracking volume is exposed to intense radiation. All materials used in the system must therefore be radiation tolerant. This is required for both the system itself and the coolant. On the one hand the 2PACL cooling technique [2],[3] allows for placement of only passive i.e. un-breakable components in the LHC radiation zones. CO 2 can withstand large doses of ionizing radiation. Low temperature. Besides just removing the heat produced in the readout electronics, the cooling system must keep the solid state silicon sensors at a temperature well below C. This significantly increases the lifetime of a silicon detector inside a high radiation environment. Evaporative CO 2 cooling theoretically allows temperatures down to -55 C. A typical detector needs a cooling temperature between -25 C and -4 C. Temperature stability. We need to keep temperature fluctuations as small as possible in order to maintain the mechanical stability needed for precise position measurements. Temperature stability is guaranteed by the 2PACL technique that will be briefly discussed in the next section.

Currently the LHCb experiment [4] at the LHC already uses evaporative CO 2 cooling. The system is working well and other experiments in particle physics expressed interest to use CO 2 as well for future upgrades of the equipment. To support the design of new evaporative cooling systems we are assembling a test facility at Nikhef where we can thermally characterize detector structures and components. We will use the facility also to further investigate the behavior of CO 2 with emphasis on flow properties in small diameter tubes. The results of these measurements can then be used as input parameters for detector design. In this paper we present the first measurements of room temperature heat transfer of two stainless steel tube samples. EXPERIMENTAL SETUP We use evaporative CO 2 cooling at ambient temperature following the 2PACL technique (2-Phase Accumulator Controlled Loop) developed at Nikhef [2],[3] A schematic diagram of the cooling facility is shown in Figure 1 and a picture of the setup is shown in Figure 3. F E system is controlled by means of a Siemens S3 PLC: in this ambient cooler the only parameter that can be controlled is the CO 2 flow, which can be set by means of a profibus connection to the pump. In addition to the control, the PLC records the pressure, temperature, and the mass flow in the cooling plant. The functionality of the PLC control will be increased, when the ambient temperature cooling apparatus is upgraded to a more versatile system that can span the full range of evaporative temperatures from -5 C to +27 C. The bottle will be replaced by an accumulator as it was used in LHCb and the concentric tube condenser by a plate heat exchanger. Both accumulator and condenser will be cooled by an external cryostat. The internal heat exchanger will be replaced by an electric heater to control better the inlet condition of the experiment. Pressure (bar) 75 7 65 6 5 1 15 2 25 3 35 4 45 5 CO 2 bottle A B C D Cooling water at 6 C 55 2 25 3 35 4 45 Figure 2: Example of the 2PACL cooling cycle of the ambient cooling plant in the enthalpy pressure diagram. Since a pumped system is used, the cooling plant cycle is in the liquid phase, the experiment in 2-phase. Figure 1: Schematic view of the ambient temperature evaporative CO 2 cooling apparatus. A Gather 1M-J/12-11/X-SS/S/Qk2/DLC gear pump (A- B) circulates CO 2 liquid through the system. After the pump the CO 2 temperature is raised to the returning vapor temperature by means of a concentric tube heat exchanger (B-C). The experimental setup (D-E) is after a restriction/capillary (C-D). The returning vapor-liquid mixture is condensed and subcooled (F-A) by cooling water of 6 C in a concentric tube heat exchanger. The sub-cooled liquid is fed back to the pump. The evaporator pressure is determined by an accumulator. It passively regulates the pressure inside the CO 2 return-line and thus in the experimental setup. The presented measurements are all done with a normal storage bottle as accumulator. The ambient temperature bottle controls the evaporator temperature in the experiment to be at the ambient temperature. Figure 2 shows an example of what the 2PACL cooling loop for the ambient temperature cooling plant looks like in the enthalpy pressure diagram. All measurements presented in this paper have been done with this ambient temperature cooling system. The cooling 2PACL cooler Test facility Figure 3: Picture showing the ambient temperature CO 2 cooling apparatus (left) and the isolated test-facility (right). In the foreground the data-acquisition PC with PVSS software is visible that controls the experiment and gives the necessary input parameters to the cooling machine.

The discussed experiments in this paper (D-E in Figure 1) were done on an ID=1.2mm and ID=1.6mm stainless steel tube with a length of 8mm. The tubes were heated running a DC current through the stainless steel tube over a length of 715mm using a remotely controlled Delta power supply. On the heated part of the tubes 2 equally spaced type-k thermocouples were attached. To avoid grounding loops a thin layer of kapton tape was folded around the tube in order to electrically isolate the thermocouples from the sample. The main thermal effect of the kapton tape is a longer response time of the thermocouples: we estimated that the offset in temperature is below the measurement sensitivity. Readout of all thermocouples was done with a DT8 datalogger (http://www.datataker.com). In addition two thermocouples and pressure sensors are located on both the in- and outlet of the tube next to the heated zone. A picture of the experimental test facility is shown in Figure 3. The readout of the lab-experiments and the control of the cooling plant have been integrated with a PC through PVSS Scada software: PVSS Scada software is widely used in particle physics to control for example the LHC and its detectors. The readout and control of the PLC and DT8 datalogger are done through ordinary Ethernet connection, while control of the power supply and readout of additional pressure sensors is done through a CANBUS interface. Due to the high level of readoutintegration it has become possible to do a fully automated characterization of the thermal behavior of a sample. In the current system it usually takes in the order of a few hours to scan through the full range of mass flux and power density. After the cooling plant upgrade we will also be able to scan through the full temperature range. An additional advantage of the integrated approach is that it is easy to correlate cooling plant data with the data from the experimental setup, since these are contained in the same data set. MEASUREMENT PRINCIPLE The test set-up measures the in- and outlet temperatures and pressures. On the test tube thermocouples are mounted on the heated zone. The in and outlet sensors are mounted outside the heated zone. The coolant at the inlet of the test tube is kept single phase so the combination of pressure and temperature can be used to determine the inlet enthalpy. The enthalpy is derived from the Refprop database [5] which is implemented in Matlab. Matlab is used to analyze and plot all measurements. For each thermocouple location the pressure and enthalpy with respect to the known inlet condition is calculated. The temperature measurement is corrected for thermal conductivity from the outside of the tube wall to the inside. ENTHALPY The enthalpy of each sensor location is calculated from the known inlet enthalpy, the mass flux and the applied heat flux. = + (1.1) Where H is the enthalpy, Φ the heat flux, z the position along the tube, ID the inner diameter of the tube and the mass flux. The enthalpy calculation of equation 1.1 can be checked in case superheated vapor is present at the outlet. In this case the enthalpy can be derived as well from the Refprop database as a function of the measured temperature and pressure. PRESSURE DROP The pressure drop over both stainless steel tubes has been measured as a function of the mass flux (see Figure 4). The pressure drop was measured by subtracting the pressure measured by absolute pressure sensors at both the inlet and outlet of the tubes. A quadratic fit to the points, indicated by the dotted lines, describes the data well. P (bar).4.35.3.25.2.15.1.5 ID=1.2mm ID=1.6mm -.5 2 4 6 8 1 12 14 16 18 2 Mass Flux (kg/m 2 /s) Figure 4: Pressure drop over the ID=1.2mm and ID=1.6mm stainless steel tubes as a function of the mass flux. The dotted lines represent a quadratic fit to the points. To calculate the temperature of the CO 2 at every location on the tube we need to estimate the pressure along the tube. Since we do not know the exact profile of pressure as a function of position we assume a simplified linear dependence of pressure on position. In reality this is not the case as the vapor quality is not constant. = + / (1.2) Where z is the position along the tube, P the pressure at inlet the inlet of the tube, P the pressure drop and L the length of the tube. For the ID=1.2mm tube the pressure drop of 35mbar at the highest mass flux results in a change in evaporation temperature of.2 C. At low temperatures a correction for the pressure drop is crucial for good estimation of the CO 2 temperature. It has to be noted though that there is a 2-3 mbar offset in the pressure measurement. To increase the precision of our saturation temperature calculation we need to use more accurate pressure sensors. We will also add a differential pressure sensor in the future to measure the pressure drop directly. The calculated pressure of equation 1.2 is used to calculate the CO 2 evaporation temperature at each temperature sensor location. At 2 C an error in the pressure measurement of 5mbar results in an offset of.5 C in the calculated evaporation temperature. This is well below the uncertainty of

the thermocouples used to measure the stainless steel tube wall temperatures. At a temperature of -4 C the temperature effect is of the order of.1 C: a small value for which we need to correct in order to obtain accurate measurements of heat transfer. TEMPERATURE PROFILES The temperature along both stainless steel tubes have been measured at 2 equally spaced locations. Figure 5 shows the temperature as a function of the heat flux for three of the sensors: one located at the beginning of the heated length (z=.2m), one in the middle (z=.24m) and one close to the end (z=.65m). The heat flux range is chosen such that it covers the full range of cooling power we expect for new applications in particle physics detectors. The line with blue stars is close to the inlet and boiling starts at high heat fluxes (52 kw/m 2 ), the line with the green dots is near the outlet. Here the boiling starts already around 14 kw/m 2 and dry-out sets in at 62 kw/m 2. Temperature ( C) 38 36 34 32 3 28 26 24 22 2 Mass Flux = 1.9e+3 kg/m 2 /s z=.2m z=.24m z=.65m 1 2 3 4 5 6 7 8 Heat Flux (W/m 2 ) x 1 4 Figure 5: Measured temperature as a function of the heat flux for the ID=1.2mm tube. The different lines show the temperatures at three different locations. Figure 6 shows the temperature along the ID=1.2mm tube as function of enthalpy for a mass flux of 1.9 1 3 kg/m 2 /s. The fluid temperature at each location is calculated from the enthalpy of equation 1.1 and the pressure of equation 1.2 using the Refprop database. This method of temperature calculation is independent of the local phase. It always derives the real CO 2 condition from Refprop which can be sub-cooled, saturated or superheated. The dashed lines show these calculated temperatures. The sub-cooled liquid to 2-phase transition is clearly visible by the sharp bend. In Figure 7 an example of the 2-phase to super-heated vapour transition is shown. At a relatively low heat flux of 3.28 1 4 W/m 2 (red squares) the temperature on the tube wall decreases suddenly at the transition from sub-cooled to saturated liquid. For larger enthalpies the temperature slowly decreases as the liquid passes through the tube, due to the drop in pressure. The calculated saturation temperature profile (red dotted line) shows the same behaviour. At the higher heat flux, the transition from the sub cooled liquid to 2-phase is not so clear. Clearly visible here is the sudden temperature increase around x=.45. Dry-out has set in while the fluid temperature remains saturated (blue dotted line). Temperature ( C) 25 24 23 22 21 Mass Flux = 1.9e+3 kg/m 2 /s x=. x=.2 x=.4 x=.6 25 26 27 28 29 3 31 32 33 34 35 Figure 6: Temperature along the ID=1.2mm cooling tube as a function of the CO 2 enthalpy for two values of the heat flux. The mass flux is 1.9 1 3 kg/m 2 /s. The dotted lines show the calculated saturation temperature at the same enthalpy. Figure 7 shows the temperature as a function of enthalpy for a much lower mass flux of 4.5 1 2 kg/m 2 /s. At x>.75 dry-out becomes clearly visible. After fully evaporating the liquid, the temperature of the tube is determined through gas cooling, which shows inferior heat transfer compared to evaporative cooling (note the different vertical scales on Figure 6 and Figure 7). Temperature ( C) 9 8 7 6 5 4 3 2 T liquid T liquid 3.28E4 W/m 2 6.56E4 W/m 2 Mass Flux = 4.5e+2 kg/m 2 /s x=. x=.2 x=.4 x=.6 x=.8 x=1. 3.69E4 W/m 2 4.48E4 W/m 2 T vapour 25 3 35 4 45 5 T gas Figure 7: Temperature along the ID=1.2mm cooling tube as a function of the CO 2 enthalpy for two values of the heat flux. The mass flux is 4.5 1 2 kg/m 2 /s. The dotted line shows the estimated vapour/gas temperature at the same enthalpy.

HEAT TRANSFER In this section we present our first results on measurements of the heat transfer coefficient of CO 2 in small tubes at room temperature. The heat transfer coefficient is defined in the usual way as: = (1.3) where is the heat flux from the tube into the liquid, T fl the temperature of the fluid and T in the temperature of the inner tube wall. We measure the temperature, T, on the outer surface of out the tube. The heat is developed equally in the tube wall. By solving the heat transport equation in cylindrical coordinates we obtain for T : in = + ln + (1.4) Where is the volumetric power density and the thermal conductivity of the tube. For this equation we assume that all the heat that is generated is absorbed through the inner surface of the tube by the CO 2 coolant. Since we are operating our cooling facility close to room temperature we expect the effects of heat leaks to be small. The temperature corrections we calculate in this way vary from -.5 C depending on the power density. Although this correction is rather small it still constitutes a 15-2% effect on the HTC: especially for large HTC values when the temperature differences are small. In the future when we run cold measurements the heat leak will be evaluated by measuring the temperature increase at a sub cooled liquid flow. htc (W/m 2 /K) Mass Flux = 1.9e+3 kg/m 2 /s 8 x 14 x=. x=.2 x=.4 7 6 5 4 3 2 1 2.55E4 W/m 2 4.37E4 W/m 2 6.2E4 W/m 2 24 25 26 27 28 29 3 31 32 33 34 Figure 8: Heat transfer coefficient as a function of enthalpy and heat flux for the 1.2mmID tube Figure 8 shows an example of the heat transfer coefficient calculated with the temperature correction of equation 1.4 as a function of the enthalpy. The HTC increases from liquid to 2-phase heat transfer and remains constant at increasing vapor qualities. The heat transfer coefficient increases with the applied heat flux. The value for the evaporative HTC ranges from about 2 1 4 W/m 2 /K at low heat fluxes of the order of 5 1 4 W/m 2 /K at high heat fluxes. We expect lower HTC s once we will measure the same samples in the lower temperature range (down to -4 C) which is the interesting range for particle physics applications. Around x=.45 a dry-out is observed by a sudden decrease of the heat transfer coefficient. Just before this dry-out an increase of the HTC is observed, which we do not completely understand at the time of writing this paper. In Figure 9 the heat transfer results of 62kW/m 2 from figure 8 are plotted in a flow pattern/heat transfer plotting tool from the online engineering databook III of Thome [6]. The heat transfer prediction according to Kandlikar [7] is added in the same figure. The measurements show a much more constant heat transfer over vapor quality and a sudden decrease at dryout. Both models show a slow dry-out slope. The upgrade of the cooling plant to colder temperatures will give us the possibility to scan the full phase space of mass flux, heat flux, temperature and tube diameter. The automatic measurement protocol will generate a database at which we will check the available models in the future. Mass Velocity [kg/m 2 s] 2 18 16 14 12 1 8 6 4 2 Process Path Intermittent Annular D Stratified,2,4,6,8 1 Vapor Quality [-] Figure 9: The heat transfer measurement of 62 kw/m 2 from figure 8 plotted in the Thome flow pattern map. The red curve is the heat transfer calculated by the Thome, the blue curve is the heat transfer according to Kandlikar. DRY-OUT BEHAVIOR 6 5 4 3 2 1 To further investigate the dry-out behaviour in the samples of stainless steel tubes, we have plotted the HTC divided by the heat flux as a function of the CO 2 vapour quality (see Figure 1 and Figure 11). In these figures all the measured HTC from all sensors at all settings of heat flux and CO 2 mass flux are plotted. Both samples show a high HTC compatible with CO 2 evaporative cooling up to a critical value, x c, of the vapour quality. Above x c the relative HTC drops to a much lower value: still some heat is rejected, but now by means of gas cooling. The ID=1.2mm tube dries out for vapour qualities in the range of x c =.45 to.65, while the larger ID=1.6mm tube has a significantly higher dry out range between x c =.85 and.95. Heat Transfer Coefficient [W/m 2 K]

REFERENCES Figure 1: Heat transfer coefficient divided by heat-flux as a function of the CO 2 vapour quality for an ID=1.2mm stainless steel tube. Note that the wider range of HTC/Φ heat is at x<, which is sub-cooled. htc / Φ heat 1.5 1.5 R=1.6mm [1] Evans, L Bryant, P. 28, LHC Machine, JINST 3 S81 [2] Verlaat B. 27. Controlling a two-phase CO2 loop using a two-phase accumulator. International Conference of Refrigeration 27, Beijing, China, ICR7-B2-1565 [3] Verlaat B. et al, 28. CO2 cooling for the LHCb- VELO experiment at CERN. 8th IIF/IIR Gustav Lorentzen Conference on Natural Working Fluids 28, Copenhagen, Denmark, CDP 16-T3-8 [4] Augusto Alves Jr, A. 28. The LHCb Detector at the LHC. JINST 3, S85. [5] Lemmon, E.W, et al., 27, REFPROP, Reference Fluid Thermodynamic and Transport Properties, NIST Reference Database 23, Version 8. [6] Thome J.R. 29, Engineering Data Book III, http://www.wlv.com/products/databook/db3/databoo kiii.pdf [7] Kandlikar S et al. 25, Heat Transfer and Fluid Flow in Minichannels and Microchannels, ISBN:- 84-4527-6.2.4.6.8 1 1.2 1.4 1.6 Figure 11: Heat transfer coefficient divided by heat-flux as a function of the CO 2 vapour quality for an ID=1.6mm stainless steel tube. CONCLUSION AND OUTLOOK We have demonstrated a working CO 2 cooling plant at room temperature working according to the 2PACL principle. The plant facilitates precise measurements on CO 2 properties in small diameter tubes. The automatic measurement method is able to scan relatively easy an experimental tube, the data taken is very clean and easy to process. The first results of heat transfer coefficients have been obtained on a 1.2mm ID and 1.6mm ID stainless steel tube. The heat transfer coefficients we measure are roughly in agreement with the model predictions by Thome et al., though we see a sharp increase in heat transfer coefficients just before dry-out sets in. At the time of writing this paper this phenomenon is under study. Furthermore we have observed that dry-out sets in at higher vapor quality for a larger inner-diameter tube. The aim of our measurement program is to map all parameters relevant to heat transfer for CO 2. In the presented tests a 2d scan was made (heatflux & massflux), in the future a 3d scan can be performed including pressure and hence temperature. This way a full data base of heat transfer and pressure drop data will be generated, which we will compare to the available theory. The test set-up will also be used to characterize the thermal behavior of particle physics detector structures which will use CO 2 cooling for their thermal control. x