Turbidity measurement with Turbiquant

Similar documents
Operating Manual. Turb 355 IR/T. Portable turbidimeter. ba75454e03 09/

ph/redox Measurement CPM 280

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Photometer AL250. Scroll Memory (SM) N.I.S.T Traceability. Highlights

Moisture Analyzers.

Automatic titrators, TitroMatic

NANOCOLOR UV /VIS & VIS

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Mobile coulometer for water determination anywhere you want

COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

Relative pressure transmitter type 520

QUANTUM CONCEPT. Swimming User s Manual

The first address for Titration. TITRONIC 300 and TitroLine 5000

473-SHX Dew Point Mirror

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

INFORMATION LABORATORY ANALYSIS UV-VIS SPECTROPHOTOMETER DR Simply more DR 5000 UV-VIS Spectrophotometer

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

Vet Photometer DP 700 Operating Manual. Version V5.9

Intelligent Sensor Management for Brewing Processes

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR

LUMiSizer. Dispersion Analyser. The All-in-One. Dispersion Analyser. Stability Demixing Consolidation Particle Sizing

Karl-Fischer Titration the method for determining water

HD32.2 WBGT Index HD32.3 WBGT-PMV. [ GB ] - WBGT index. - PMV index and PPD

WATER ACTIVITY MEASUREMENT WATER ACTIVITY

P S H - S 3G m t e e t r e (C ( E mar ar e k d e ) P B H - B 4 - Por or ab ab e l PH M t e e t r

ED 701 General Industry Pressure Transmitter

TURBIDIMETRY & NEPHELOMETRY. Mohsin Al-Saleh, Senior Biomedical Scientist (BSc. MLS-2004/MSc Clini. Chem. 2013) ID#6837

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

Thermometers. Applications

One-hand ph/temperature measuring instrument

Biochrom Libra. UV-Visible Spectrophotometers. High performance instruments with added application value for academia, research and industry

Quantum Series Product Catalog

IDENTIFICATION STS400

Operating Instructions for Digital Manometer. Model: MAN-SD

Technical Paper 3 Verifying Particle Counter Calibration: Size Verification

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

HD32.2 WBGT Index HD 32.2 INSTRUMENT FOR THE ANALYSIS OF THE WBGT INDEX

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

Air velocity & IAQ measuring instruments

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

THERMYS 150. Advanced field reference thermometer / temperature calibrator

Chlorine disinfectant in the water industry

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

Ion-Selective Measurements

Instruction Manual HI 96738C Chlorine dioxide ISM

ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20

Instruction Manual HI 96710C ph & Chlorine ISM

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Ion-selective Measurements

HI REDUCING SUGARS ISM for wine analysis

ISEmax CAM40/CAS40. Technical Information

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Instruction Manual HI 96720C Calcium Hardness ISM

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

The New Quintix. Intuitive application guideance. Maximum accuracy at all time. Easy cleaning. Plug & Work connectivity to printer or computer

Non-Contact Safety Systems CMS

NSG 4070C APPLICATION FOR MIL-STD 461G CS 114

JAPAN QUALITY. Automated Clinical Analyzer

NECi Nitrate Kits FAQs

CP3000. Automated Coagulation System POWE R F U L LY CO M PAC T STREAM LI NED EF F I CI ENCY SI M PLE AND INTUITIVE CH OO SE T RA NS FO R MATIO N

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

PhysioCare Concept improved. The feeling of a new philosophy

2100TR Liquid Scintillation Counter

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

PhysioCare Concept improved. The feeling of a new philosophy

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

The Plus for your lab!

VD1 CLC. Small Valves DIN-range with a higher k v -value

ABX Pentra 400. Clinical Chemistry System. Up to 420 tests/hour 55 Assays Validation Station

Acceleration/Velocity/Displacement VIBRATION METER

CuBiAn XC C u l t u r e B i o c h e m i s t r y a n a l y z e r extra compact

Solenoid valves Type EVUL

W 9 L: Laser photoelectric switches: small, light and reliable

Acetylcholinesterase Assay Kit

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Single Phase Motors Technical Datasheets

Instruction Manual HI Refractometer for Invert Sugar Measurements

Bright Advance Corporation

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

MAHR UK PLC I GAUGING TIP GAUGING TIP: DIN OR AGD WHAT'S RIGHT FOR ME?

Water Analysis VISOCOLOR VISOCOLOR. Water analysis made easy. VISOCOLOR tests for water analysis

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

JAPAN QUALITY. Automated Clinical Analyzer

Automated Clinical Analyzer

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

Absolute encoders multiturn

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Transcription:

Turbidity measurement with Turbiquant Overview of devices The method of measurement employed in the TURBIQUANT 1100 / 1500 / 3000 IR conforms with EN ISO 7027, that used in the TURBIQUANT 1100 / 1500 / 3000 T models follows the recommendations of the USEPA. TURBIQUANT 1100 IR or 1100 T The TURBIQUANT 1100 is a portable turbidimeter which works on batteries. The 4 standard batteries allow more as 5000 measurements. The easy use, the compact carrycase and the watertight housing - to protect the electronic components - all these are features that make the new TURBIQUANT 1100 IR or 1100 T the ideal device for analysis in the field. IR: Light source T: Light source 1.18324.0001 TURBIQUANT 1100 IR turbidimeters, portable 2 empty,, case, 4 batteries measuring principle nephelometric 90 scattered light indication of units NTU / FNU measuring range 0.01...1100 NTU resolution 0.01 within the range 0.01 < x < 99.99 NTU 0.1 within the range 100 < x < 999.9 NTU 1 within the range 1000 < x < 1100 NTU + 2 % of reading or + 0.1 NTU, for range 0-500 NTU + 3 % of reading for range 500-1100 NTU automatic 1 to 3 points response time 14 seconds 25 x 45 mm sample volume 15 ml protection type designed to meet IP 67 GLP function control of intervals, self test, power requirements 4 alkali manganese AAA/Micro CE Also required: Turbiquant Calibration Standard Set 1.18335.0001 1.18325.0001 TURBIQUANT 1100 T turbidimeters, portable 2 empty,, case, 4 batteries specifications measuring principle indication of units same as TURBIQUANT 1100 IR, but additionally nephelometric 90 scattered light NTU / FNU Also required: Turbiquant Calibration Standard Set 1.18335.0001

TURBIQUANT 1500 IR or 1500 T These two devices have large and readily legible displays and can be easily operated with just a few keys. The user guidance via the display is state of the art. A high sample throughput can be achieved by means of a pour through assembly. IR: Light source T: Light source 1.18330.0001 TURBIQUANT 1500 IR turbidimeters indication of units NTU measuring range 0-1000 NTU resolution max. 0.01 within the range 0 < x < 10 NTU max. 0.1 within the range 10 < x < 100 NTU max. 1 within the range 100 < x < 1000 NTU + 2 % of reading or + 0.01 NTU, for range 0.00-1000 NTU repeatability < + 1% of reading or + 0.01 NTU automatic 1 to 3 points response time < 3 seconds 28 x 70 mm sample volume 25 ml serial input / output RS 232, uni-directional real time clock integrated GLP function control of intervals, self test power requirements universal power supply / plug CE, UL, CSA, TÜV-GS Also required: Turbiquant Calibration Standard Set 1.18328.0001 1.18331.0001 TURBIQUANT 1500 T turbidimeters specifications same as TURBIQUANT 1500 IR, but additionally Also required: Turbiquant Calibration Standard Set 1.18328.0001

TURBIQUANT 3000 IR or 3000 T In addition to the specified features of the TURBIQUANT 1500 IR and 1500 T the user can select different measurement modes and indications of the measurement results. The TURBIQUANT 3000 IR, for example, can display the following units: NTU (Nephelometric Turbidity Units, 90 scattered-light measurement) EBC (Recommendation of the European Brewery Commission) FNU (Formazine Nephelometric Units, i.e. with formazine) FAU (Formazine Attenuation Units, i.e.: DIN measurement above 40 FNU). The methods that are available are those of nephelometry, lighttransmission measurement, and ratio measurement. It is also possible to measure in the continuous mode with a low-pressure flow-through assembly using a purging gas. 1.18332.0001 TURBIQUANT 3000 IR turbidimeters measurement modes nephelometric (non ratio / ratio selectable) indication of units NTU, FNU, FAU, EBC measuring range 0-10 000 NTU 0-10 000 FNU 0-10 000 FAU 0-2450 EBC resolution selectable 0.1-0.0001 NTU max. 0.0001 within the range 0 < x < 10 NTU max. 0.001 within the range 10 < x < 100 NTU max. 0.01 within the range 100 < x < 1000 NTU max. 0.1 within the range 1000 < x < 10 000 NTU + 2 % of reading or + 0.01 NTU, for range 0.00-1000 NTU + 5 % of reading for range 1000-4000 NTU + 10 % of reading for range 4000-10 000 NTU repeatability < + 1% of reading or + 0.01 NTU automatic 1 to 4 points (to 1750 NTU) 10 000 NTU selectable response time < 6 seconds 28 x 70 mm sample volume 25 ml serial input / output RS 232, bi-directional real time clock integrated GLP function control of intervals, self test, and instrument configuration are access code protected power requirements universal power supply / plug CE, UL, CSA, TÜV-GS Also required: Turbiquant Calibration Standard Set 1.18329.0001

1.18333.0001 TURBIQUANT 3000 T turbidimeters specifications same as TURBIQUANT 3000 IR, but additionally indication of units NTU, EBC, Nephelos measuring range 0-10 000 NTU 0-2450 EBC 0-67 000 Nephelos Also required: Turbiquant Calibration Standard Set 1.18349.0001 Accessories 1.18320.0001 TURBIQUANT 1000 / 1100 (1 pack = 3 pcs) 1.18336.0001 TURBIQUANT 1500 / 3000 (1 pack = 3 pcs) 1.18344.0001 TURBIQUANT 1500 IR lamp module 1.18382.0001 TURBIQUANT 3000 IR lamp module 1.18338.0001 TURBIQUANT 1500 / 3000 tungsten lamp module 1.18339.0001 TURBIQUANT 1500 / 3000 cuvette stand 1.18340.0001 TURBIQUANT 1500 / 3000 pour through assembly 1.18341.0001 TURBIQUANT 3000 flow-through assembly 1.09759.0001 Printer cable for TURBIQUANT 1500 / 3000 (for serial interface) 1.14667.0001 PC cable for TURBIQUANT 1500 / 3000 (for serial interface)

Standards TURBIQUANT Primary standard AMCO-AEPA-1 Microspheres are cited as Primary Calibration Standards in compliance with USEPA Method 180.1. (see also: Standard Methods for Examination of Water and Wastewater 21st Edition (2005), Section 2130, Turbidity). The standards are also accepted as Alternative Use Secondary Standards equivalent to freshly prepared Formazin suspensions Ref. EN IS0 7027: 1999 Water Quality - Determination of Turbidity. The new TURBIQUANT Calibration standards offer the following advantages: 1. Cited as primary standards in compliance with USEPA method 180.1. 2. Accepted as alternative use secondary standards according EN ISO 7027:1999. 3. More stable than formazin with a minimum shelf life of 12 months. 4. Non toxic. 5. Can be stored and transported without any precautionary measures. 6. Supplied ready-to-use. 7. Coming with indexing ring for quick and repeatable indexing as recommended by USEPA. 8. Incomparable precision: 10 NTU +/- 1% 100 NTU +/- 1% 1 000 NTU +/- 1% 1750 NTU +/- 2% 10 000 NTU +/- 2% 1.18327.0001 TURBIQUANT 1000 IR Calibration standard set 4 Standards 0.02-10.0 100.0-1000 NTU 1.18335.0001 TURBIQUANT 1100 IR / 1100 T Calibration standard set 3 Standards 0.02-10.0-1000 NTU 1.18328.0001 TURBIQUANT 1500 IR / 1500 T Calibration standard set 3 Standards 0.02-10.0-1000 NTU 1.18329.0001 TURBIQUANT 3000 IR Calibration standard set 4 Standards 0.02-10.00-100.0-1750 NTU 1.18349.0001 TURBIQUANT 3000 T Calibration standard set 4 Standards 0.02-10.00-100.0-1750 NTU 1.18342.0001 TURBIQUANT 3000 IR Calibration standard 10 000 NTU 1.18343.0001 TURBIQUANT 3000 T Calibration standard 10 000 NTU 1.18381.0001 TURBIQUANT 1500 / 3000 Calibration standard 10 NTU