Introduction to the Q Trap LC/MS/MS System

Similar documents
Accurate, High-Throughput Protein Identification Using the Q TRAP LC/MS/MS System and Pro ID Software

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

Powerful Scan Modes of QTRAP System Technology

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Mass Spectrometry in MCAL

TANDEM MASS SPECTROSCOPY

Translational Biomarker Core

Analysis of Polar Metabolites using Mass Spectrometry

Types of Analyzers: Quadrupole: mass filter -part1

ABI 3200 Q TRAP LC/MS/MS System

Thermo Finnigan LTQ. Specifications

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

MS/MS .LQGVRI0606([SHULPHQWV

Finnigan LCQ Advantage MAX

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Lecture 8: Mass Spectrometry

Lecture 8: Mass Spectrometry

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

CEE 772: Instrumental Methods in Environmental Analysis

Information Dependent Acquisition (IDA) 1

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

Extrel Application Note

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Quattro Micro - How does it work?

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

Chemistry Instrumental Analysis Lecture 34. Chem 4631

The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS)

Secondary Ion Mass Spectroscopy (SIMS)

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

GRADUATE COURSE IN MASS SPECTROMETRY: LECTURE 2

Introduction to LC-MS

Harris: Quantitative Chemical Analysis, Eight Edition

Mass Analyzers. Ion Trap, FTICR, Orbitrap. CU- Boulder CHEM 5181: Mass Spectrometry & Chromatography. Prof. Jose-Luis Jimenez

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Mass Selective Ejection by Axial Resonant Excitation from a Linear Ion Trap

Suzanne Bell Second Edition

MS Goals and Applications. MS Goals and Applications

ICPMS Doherty Lecture 1

Ion traps. Quadrupole (3D) traps. Linear traps

1. The range of frequencies that a measurement is sensitive to is called the frequency

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Ion trap. 3D Quadrupole Trap. -Mass spectrometer -Ion trap (Quadrupol Ion Storage, Quistor) 18. April

This is the total charge on an ion divided by the elementary charge (e).

The Aerosol Ion Trap Mass Spectrometer (AIMS): Instrument development and first experimental results

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Choosing the metabolomics platform

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Mass Spectrometry. What is Mass Spectrometry?

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

Mass Spectrometry. Ionizer Mass Analyzer Detector

Interface (backside) & Extraction Lens

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Space Charge Effects in Linear. Quadrupole Ion Traps

Extrel is widely respected for the quality of mass spectrometer systems that are

Mass Spectrometry. Quantitative Mass Spectrometry Chiral Mass Spectrometry

Instrumentation development for coupling ion/ion reactions and ion mobility in biological mass spectrometry

Atomic masses. Atomic masses of elements. Atomic masses of isotopes. Nominal and exact atomic masses. Example: CO, N 2 ja C 2 H 4

Mass Spectrometer A Comparison of Positive and Negative Ion RGA Methods

Ionization Techniques Part IV

Simulation of External Ion Injection, Cooling and Extraction Processes with SIMION 6.0 for the Ion Trap/Reflectron Time-of-flight Mass Spectrometer

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR-MS)

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

MASS SPECTROMETRY. Topics

Quadrupole Storage Mass Spectrometry

Mass Spectrometry and Proteomics - Lecture 2 - Matthias Trost Newcastle University

Week 5: Fourier Tranform-based Mass Analyzers: FT-ICR and Orbitrap

Catalysis CAPABILITIES

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Mass spectrometry of proteins, peptides and other analytes: principles and principal methods. Matt Renfrow January 11, 2008

LECTURE-11. Hybrid MS Configurations HANDOUT. As discussed in our previous lecture, mass spectrometry is by far the most versatile

Laser Dissociation of Protonated PAHs

Tandem MS = MS / MS. ESI-MS give information on the mass of a molecule but none on the structure

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Mass spectrometry.

CHAPTER I. Introduction of HPLC, LC-MS/MS and aim of the work

Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4.

WADA Technical Document TD2003IDCR

Chemistry Instrumental Analysis Lecture 35. Chem 4631

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS

MS Goals and Applications. MS Goals and Applications

Theory, Design, and Operation of a Dynamic Reaction Cell for ICP-MS

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Mass Spectrometry. Fundamental LC-MS. Mass Analysers

Spectrometric Methods of Analysis. OCN 633 Fall 2013

Interpretation of Organic Spectra. Chem 4361/8361

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

4000 Q TRAP LC/MS/MS System. Advanced Linear Ion Trap technology at the highest level of sensitivity 4000 QTRAP. LC/MS/MS System

Mass spectrometry gas phase transfer and instrumentation

Tendenze nell innovazione della strumentazione in spettrometria di massa:

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Molecular Mass Spectrometry

Transcription:

www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment ABI Q Trap LC/MS/MS Introduction to the Q Trap LC/MS/MS System The Q Trap LC/MS/MS system is a hybrid triple quadrupole linear ion trap (LIT) mass spectrometer. The Q3 region can be operated as either a standard quadrupole mass spectrometer or a linear ion trap mass spectrometer. The unique scan modes of both configurations can be linked to provide more and higher quality data than either instrument alone. For example, a precursor ion scan in Transmission mode can be used as a survey scan in order to target specific ions to be used in an enhanced product ion scan (in LIT mode). Conversion between the two modes of operation is rapid, since it involves only the addition or removal of the resolving DC voltages. The Q Trap LC/MS/MS system retains all of the traditional triple quadrupole scan types such as: Q1 MS (Q1) Q1 Multiple Ion (Q1 MI) Q3 MS (Q3) Q3 Multiple Ion (Q3 MI) Multiple Reaction Monitoring (MRM) Precursor Ion (Prec) (This is not possible with a conventional ion trap.) Product Ion (MS2) Neutral Loss (NL) When Q3 operates as an LIT mass spectrometer, a number of new advantages and capabilities are available: High sensitivity product ion scanning Fast scanning (4000 amu per second) High resolution capabilities at reduced scan speeds MS/MS/MS capabilities Reduced space charge effects In LIT mode, a pulse of ions is introduced into the ion trap. The main RF fields trap the ions in the radial direction, while DC voltages applied to the lenses at both ends of Q3, trap the ions axially. The trapped ions are allowed to cool for several milliseconds, then the RF voltage is scanned in the presence of a low voltage auxiliary AC applied to the rods. The ions ejected axially toward the detector are counted. If you configure the mass spectrometer with Q1 operating as a standard quadrupole mass spectrometer and Q3 operated as an LIT mass spectrometer, you can achieve the following enhanced scan types: Enhanced MS (EMS) Enhanced Resolution (ER)

Enhanced Product Ion (EPI) Enhanced Multi-Charge (EMC) Time Delayed Fragmentation (TDF) MS/MS/MS (MS3) In LIT mode, a pulse of ions passes through Q1 operated as a conventional quadrupole mass spectrometer to select the precursor ion of interest. The precursor ions are accelerated into the pressurized Q2 to promote fragmentation. The fragment and residual precursor ions are then trapped in the Q3 linear ion trap. The Q3 RF voltage is ramped and the ions ejected toward the detector are reported. For more information about these enhanced scans, see Q Trap LC/MS/MS Enhanced Modes of Operation on page 10. Triple Quadrupole/Linear Ion Trap Mass Spectrometer The Q Trap LC/MS/MS system uses a TurboIonSpray, Heated Nebulizer, or Flow Nanospray ion source to produce ions from liquid samples. The term LC/MS/MS, applied to the triple quadrupole series, is a generic label for the combined analytical processes of liquid separation and subsequent mass spectrometric analysis. The instrument is configured to perform complex MS/MS and MS/MS/MS analysis. For less rigorous analytical requirements, it can perform single MS (LC/MS) scans. The Q Trap LC/MS/MS system allows all modes of MS/MS and MS/MS/MS operation for full characterization of biopharmaceutical compounds and the specificity needed for new drug development. For pharmaceutical and pharmacokinetic samples, MS/MS has the sensitivity and specificity required to analyze hundreds of samples per day without extensive sample preparation. For peptides and proteins, molecular weights can be determined with accuracies better than 0.01% at 200 kda. The major components of the Q Trap LC/MS/MS system are shown in the figure Q Trap LC/MS/MS system components with pump on page 7. Principles of MS In Single Quadrupole mode, the Q Trap LC/MS/MS system separates ions representative of the sample molecular components based on their m/z ratio. Ions of a unique m/z ratio can be separated by the single mass filter quadrupole and counted to provide mass spectra for the sample. The mass filter quadrupole consists of four cylindrical rods mounted in a ceramic collar surrounding the ion path. Fixing the ratio of RF to DC voltages applied to the quadrupole rods determines the mass of the ions exiting the quadrupole. Ions of a unique m/z ratio pass unobstructed through the quadrupole as a function of the quadrupole power supply (QPS) voltages applied. Ions of different m/z ratios have unstable oscillations that increase in amplitude until they collide with the quadrupole rods and are removed from the ion stream. As an example, a sample mixture containing three molecules, R, M, and N, is introduced into the ion source. Soft ionization in the ion source generates R+, M+, and N+ ions (quasi-molecular ions formed typically by attaching one or more protons in the Positive mode, or by removing one or more protons or attaching an electron in the Negative mode). Isolation of mixture R, M, and N Additional structural information can sometimes be obtained by fragmenting the precursor ion in a primary collision region between the orifice and the skimmer. This process is

often referred to as collision induced dissociation mass spectrometry (CID/MS). Isolation of product ions from a sample using the orifice-skimmer technique The ions generated in the ion source are drawn through a curtain of dry inert gas into the ion optics housed inside the vacuum chamber. The mass filter quadrupole in the vacuum chamber selectively filters the ions based on their m/z ratio. The filtered ions are focused to the detector. As ions collide with the detector, they produce a pulse of electrons. The electron pulse is collected and converted to a digital signal to provide an ion count as a function of ion mass. The acquired data is relayed to the computer where it can be displayed as either full mass spectra, intensity of single or multiple ions versus time, or total ion current versus time. Principles of MS/MS In Triple Quadrupole mode, the Q Trap LC/MS/MS system uses two identical mass filter quadrupoles (Q1 and Q3) separated by a collision cell, which encloses an RF-only quadrupole (Q2). The fundamental principle of MS/MS is illustrated in the figure Isolation of product ions from a mixture of R, M and N on page 8. As an example, a sample mixture containing three molecules, R, M and N, is introduced into the ion source. Soft ionization in the ion source generates R+, M+, and N+ ions (quasi-molecular ions formed typically by attaching one or more protons in the Positive mode, or by removing one or more protons or attaching an electron in the Negative mode). Isolation of product ions from a mixture of R, M and N In a Product Ion scan, the first mass filter, Q1, separates or filters ions according to their m/z ratio, and allows only one ion to enter the collision cell (M+). The M+ ion enters Q2 where it is fragmented by collision with neutral gas molecules in a process referred to as collision activated dissociation (CAD). The fragment ions generated are then passed into Q3 and filtered to provide a mass spectrum. The ions created by the source are referred to as precursor ions, the collision products are referred to as product or fragment ions. In a Precursor Ion scan, the third quadrupole (Q3) is fixed to the fragment mass of interest and the first quadrupole (Q1) is scanned over a range. The resulting mass spectrum displays the masses of all the compounds that produced the specified fragment mass. In a Neutral Loss scan, both quadrupoles (Q1 and Q3) are scanned with a constant mass difference between them. The resulting mass spectrum displays the mass of the compounds that have undergone the specified loss. This type of scan is useful in identifying compounds from similar functional groups. The fragment ions are filtered in Q3 before they are collected at the detector. As ions collide with the detector, they produce a pulse of electrons. The pulse is converted to a digital signal that is counted to provide an ion count. The acquired data is relayed to the computer where it can be displayed as either full mass spectra, intensity of single or multiple ions versus time, or total ion current versus time. The technique of MS/MS is well suited to mixture analysis because the characteristic fragment ion spectra can be obtained for each component in a mixture without interference from the other components, assuming that the ions have a unique m/z ratio. This analysis can also be used for targeted analysis by monitoring specific precursor/product ions with Q1 and Q3 respectively while the sample is eluting. This type of analysis is more specific than single MS, which only discriminates on the basis of molecular weight. The MS/MS technique is well suited to structural elucidation studies. The same fragmentation pattern that provides identification of a compound in a complex mixture can also reveal pertinent information regarding the structure of all their precursors. Additional structural information can sometimes be obtained by fragmenting the precursor

ion in a primary collision region between the sampling orifice skimmer. The fragment ions (for example, a second generation fragment ion spectrum), provide structural information on both the original precursor ions and the first generation fragment ions. Isolation of second generation product ions from mixture M The triple quadrupole instruments contain the same components as the single quadrupole instruments with the addition of a second mass filter (Q3). The high-pressure region is the same, but the high vacuum region contains the Q1 prefilter (stubbies) and the Q1 and Q3 mass filter quadrupoles that are separated by the collision cell. The collision cell is a ceramic housing enclosing the Q2 RF-only quadrupole, which when pressurized with CAD gas provides a local high-pressure region for ion fragmentation. Ions pass through the same path as in the single quadrupole instrument until they reach the Q2 RF-only quadrupole. The selected ions arrive at Q2, while those rejected eventually collide with the rods and are lost. The Q2 RF-only quadrupole is separated from the Q1 and Q3 mass filters by the interquad lenses IQ2 and IQ3 (or ST3, depending on the triple quadrupole series). The Q2 region has no mass filtering capabilities; it operates in Total Ion mode. If no CAD gas is present to fragment the sample ions, Q2 transports the ions directly into Q3. If CAD gas is present, the ions that enter Q2 collide with the neutral CAD gas molecules. If pressurized, the voltage drop between the entrance lenses and Q2 provides the ions with the energy to induce fragmentation when the ions collide with CAD gas molecules. Through the energetic collisions, the ion translational energy is converted into internal energy that fractures bonds and causes ion fragmentation. After collision, the unfragmented precursor ions and the fragmented ions are transported to Q3 where they are again filtered. When operating in MS/MS mode, the Q3 mass filter is physically and functionally identical to Q1. The ions, including a mixture of precursor and fragment ions, enter Q3 where they are filtered according to mass. In Single MS Operating mode (Q1 scan type), Q3 acts as an ion transporter (like a Q0 or RF-only quadrupole) with no filtering action. Terms used to describe this operation are Total Ion mode, RF-only mode, and AC-only mode. Q Trap LC/MS/MS Enhanced Modes of Operation The Q Trap LC/MS/MS system has a number of enhanced modes of operation. A common factor of the enhanced modes is that ions are trapped in the Q3 quadrupole region and then scanned out to produce full spectrum data. Many spectra are rapidly collected in a short period of time and are significantly more intense than spectra collected in a comparable standard quadrupole mode of operation. The widths of the peaks in the spectra are usually much narrower than peaks observed in the standard quadrupole mode. During the collection phase, ions pass through the Q2 collision cell where CAD gas focuses the ions into the Q3 region. The Q3 quadrupole is operated with only the main RF voltage applied. Ions are prevented from passing through the Q3 quadrupole rod set and are reflected back by an exit lens to which a DC barrier voltage is applied. After the fill time elapses (a time defined by the user), a DC barrier voltage is applied to a Q3 entrance lens (IQ3). This confines the collected ions in Q3 and stops further ions from entering. The entrance and exit lens DC voltage barriers and the RF voltage applied to the quadrupole rods confine the ions within Q3. During the scan out phase, a potential of a few volts is applied to the exit lens to repel the charged ions. An auxiliary AC frequency is applied to the Q3 quadrupole. The main RF voltage amplitude is ramped from low to high values, which sequentially brings masses into resonance with the auxiliary AC frequency. When ions are brought into resonance

with the AC frequency, they acquire enough axial velocity to overcome the exit lens barrier and are axially ejected towards the mass spectrometer ion detector. Full spectra data can be acquired from the ions collected in Q3 by rapidly scanning the main RF voltage. The enhanced modes of operation are: Enhanced MS (EMS): Ions are transferred directly from the ion source and orifice region to the Q3 quadrupole where they are collected. These ions are scanned out of Q3 to produce enhanced single-ms type spectra. Use the EMS mode when you need a rapid enhanced sensitivity survey type scan. Enhanced Resolution (ER): This mode is similar to the Enhanced Product Ion mode except that the Q1 precursor ions pass gently through the Q2 collision cell without fragmenting. A small range about the precursor mass is scanned out of Q3 at the slowest scan rate to produce a narrow window of the best-resolved spectra. Enhanced Product Ion (EPI): Product ions are generated in the Q2 collision cell by the precursor ions from Q1 colliding with the CAD gas in Q2. These characteristic product ions are transmitted and collected in Q3. These ions are scanned out of Q3 to produce enhanced product ion spectra. Use the EPI mode if you need enhanced resolution and intensity. Enhanced Multi-Charge (EMC): This mode operates similarly to the Enhanced MS mode except, before scanning the ions out of Q3, there is a delay period in which low charge state ions (primarily singly charged ions) are allowed to preferentially escape from the Q3 quadrupole. When the retained Q3 ions are scanned out, the multiply charged ion population dominates the resulting spectra. Time Delayed Fragmentation (TDF): Product ions are generated and collected in Q3. During the first part of the collection period, the lower mass ions are not collected in Q3. During the second part of the collection period, all masses over the mass range of interest are collected. The resultant enhanced product ion spectra are simplified compared to EPI scan type spectra. The nature of the spectra aids in the interpretation of the structure and fragmentation pathways of the molecule of interest. MS/MS/MS (MS3): In MS/MS/MS mode, product ions are generated in the Q2 collision cell by the precursor ions from Q1 colliding with the CAD gas in Q2. These characteristic product ions are transmitted and collected in Q3. Applying the normal mode resolving DC voltages to the Q3 quadrupole isolates a specified mass (m/z) of ion and removes all other ions from Q3. By properly applying a second auxiliary AC frequency to Q3, the specified ion can be resonantly excited. These excited ions collide with the residual nitrogen in Q3 and may fragment, producing a characteristic spectrum of ions. These secondary product ions of the isolated product ion result in MS/MS/MS product spectra. Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment