SCANNING OF CARGO CONTAINERS BY GAMMA-RAY AND FAST NEUTRON RADIOGRAPHY

Similar documents
Design of an Integrated Inspection System For Detection of Explosive and Illicit Materials

Using Fast Neutrons to Detect Explosives and Illicit Materials

The Neutronic Check Point: fast neutron transmission measurements to detect explosives in vehicles.

Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner

NEUTRON RADIOGRAPHY OF CARGO CONTAINERS USING 2.5 MEV TAGGED NEUTRONS

Quality control of neutron-absorber materials for the nuclear fuel cycle, Principle of the JEN-3 neutron Backscattering gauge

The Use of Neutron Generators for the Detection of Illicit Materials in the Sea Transportation System

Principles and Applications of Neutron Based Inspection Techniques. Tsahi Gozani Rapiscan Laboratories 520Almanor Ave, Sunnyvale, CA

Computational study to enhance threat detection of radiation portal monitors:

Air Cargo Inspection using Pulsed Fast Neutron Analysis

POSITION SENSITIVE DETECTION OF CONCEALED SUBSTANCES EMPLOYING PULSED SLOW NEUTRONS

INTERNATIONAL ATOMIC ENERGY AGENCY PROGRAM FOR DETECTION OF ILLICIT MATERIALS

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

A Proposal of Nuclear Materials Detection and Inspection Systems in Heavily Shielded Suspicious Objects by Non-destructive Manner.

The Use of Neutron Generators for the Detection of Hidden Explosives and Illicit Materials. Giancarlo Nebbia

DEVELOPMENT OF NEUTRON INTERROGATION TECHNIQUES TO DETECT DANGEROUS SUBSTANCES

Powerful Nanosecond Single- Shot Technique for Detection of Illicit Materials and Explosives

New perspectives in X-ray detection of concealed illicit materials brought by CdTe/CdZnTe spectrometric detectors

Detection of explosives and fissile material based on neutron generators, survey of techniques and methods. M. Bruggeman

Status Report on the detection of illicit materials in cargo containers by using neutron beams.

Background Reduction Using Collimators on a Portable HPGe Nuclide Identifier

Recent improvements in on-site detection and identification of radioactive and nuclear material

The EURITRACK Project: Status of a Tagged Neutron Inspection System for Cargo Containers

MCNP Simulations of Fast Neutron Scattering by Various Elements and their Compounds in View of Elaboration of a Single Shot Inspection System

General Overview of Radiation Detection and Equipment

Neutron Based Techniques for the Detection of Illicit Materials and Explosives

The Cobalt-60 Container Scanner

Neutron and Gamma Ray Imaging for Nuclear Materials Identification

Contrabands detection with a low energy electron linac driven photoneutron source

Pulsed Neutron Interrogation Test Assembly - PUNITA

Simulation of nonorganic scintillation detector response for the problems of active interrogation by tagged neutron technology

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

PoS(FNDA2006)033. Radiography Using Fission Neutrons. Thomas Bücherl. Christoph Lierse von Gostomski

Department of Chemistry, University of Rochester, Rochester, N.Y POC:

CLASSIFICATION AND IMAGING OF SPENT NUCLEAR FUEL DRY CASKS USING COSMIC RAY MUONS

Shielded Scintillator for Neutron Characterization

nuclear material in cargo containers via active neutron interrogation

DETECTORS. I. Charged Particle Detectors

Radionuclide Imaging MII Positron Emission Tomography (PET)

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

Detection of Neutron Sources in Cargo Containers

Use of Imaging for Nuclear Material Control and Accountability

Technical University of Denmark

INTENSE PULSED NEUTRON GENERATION TO DETECT ILLICIT MATERIALS.

Integrated System for Detection of Dangerous Materials and Illicit Objects in Cargoes

Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution

Using Fast Neutrons to Detect Explosives and Illicit Materials

EXPERIMENTAL STUDY OF NEUTRON FIELDS PRODUCED IN PROTON REACTIONS WITH HEAVY TARGETS. Nuclear Physics Institute AS CR, Rez Czech Republic

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

FISSILE MATERIALS DETECTION VIA NEUTRON DIFFERENTIAL DIE-AWAY TECHNIQUE

Fissile material experiments at the Device Assembly Facility

NSD GRADEL FUSION NEUTRON GENERATORS

Using Neutron Generator with APT/NNA for Detection of Explosives

Special Nuclear Material Detection Studies With The SMANDRA Mobile System

Physics Dept. PHY-503-SEMESTER 112 PROJECT. Measurement of Carbon Concentration in Bulk Hydrocarbon Samples

MONTE-CARLO SIMULATIONS OF TIME- RESOLVED, OPTICAL READOUT DETECTOR for PULSED, FAST-NEUTRON TRANSMISSION SPECTROSCOPY (PFNTS)

Applications of MCBEND

Gamma-ray shielding of concretes including magnetite in different rate

DESIGN OF NEUTRON DOSE RATE METER FOR RADIATION PROTECTION IN THE EQUIVALENT DOSE

1 of :32

Detection of Highly Enriched Uranium Using a Pulsed IEC Fusion Device

A Comparison between Channel Selections in Heavy Ion Reactions

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Accelerator-Based Neutron Generator to Drive Sub-Critical Isotope Production Systems. Ross Radel, PhD President, Phoenix Nuclear Labs

Utilization of Variable Energy Radio-Frequency Quadrupole Linear Accelerator Systems.

Los Alamos Research Quarterly Spring

arxiv: v1 [physics.ins-det] 3 Feb 2011

Application of Nuclear Quadrupole Resonance to Detection of Explosives and Research Activities at CIAE

Neutronics Experiments for ITER at JAERI/FNS

Hands on LUNA: Detector Simulations with Geant4

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

Research in NDA Techniques for Waste Characterization at the JRC

An industrial radiography exposure device based on measurement of transmitted gamma-ray intensity

Requirements on Neutron Detectors Alternative to He-3

Fast Neutron Resonance Radiography for Elemental Imaging: Theory and Applications

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Oak Ridge National Laboratory* P. 0.Box 2008 Oak Ridge, TN (615) Presentation at. Les Houches, France.

Characterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan

Detection of Explosives and Other Illicit Materials by Nanosecond Neutron Analysis

Distinguishing fissions of 232 Th, 237 Np and 238 U with beta-delayed gamma rays

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

arxiv: v1 [physics.ins-det] 29 Jun 2011

Today, I will present the first of two lectures on neutron interactions.

RESULTS AND DISCUSSION ON EFFECT OF COLLIMATOR SIZE ON THE ATTENUATION OF GAMMA RAY IN PURE ELEMENTS

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Radiation Quantities and Units

Nuclear cross-section measurements at the Manuel Lujan Jr. Neutron Scattering Center. Michal Mocko

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Neutron Imaging System For level Interface Measurement

Effect of Cosmic-ray Shielding in Passive Neutron Coincidence Counting

Portable neutron generators of VNIIA and their applications

A dual scintillator - dual silicon photodiode detector module for intraoperative gamma\beta probe and portable anti-compton spectrometer

IPNDV Working Group 3: Technical Challenges and Solutions Nuclear Material (3) Technology Data Sheet

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Time Correlation Measurements of Heavily Shielded Uranium Metal. Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37831

A Review of NEUTRON BASED NON-INTRUSIVE INSPECTION TECHNIQUES. Tsahi Gozani Ancore Corporation Santa Clara, CA, USA

ICTP-IAEA Joint Workshop on Nuclear Data for Science and Technology: Medical Applications. 30 September - 4 October, 2013

Neutron Dose near Spent Nuclear Fuel and HAW after the 2007 ICRP Recommendations

SCINTILLATION DETECTORS AND PM TUBES

Transcription:

Armenian Journal of Physics, 2012, vol. 5, issue 1, pp. 1-7 SCANNING OF CARGO CONTAINERS BY GAMMA-RAY AND FAST NEUTRON RADIOGRAPHY A. M. Yousri*, A. M. Osman, W. A. Kansouh, A. M. Reda*, I. I. Bashter*, R. M. Megahid Laboratories for Detection of Landmines and Illicit Materials, Nuclear Research Centre, Atomic Energy Authority, Cairo, Egypt *Physics Department, Faculty of Science, Zagazig University, Cairo, Egypt E-Mail: ahmed2004ge@yahoo.co.uk Received 27 December, 2011 Abstract This paper describes the combined systems which were installed and tested to detect contraband smuggled in cargo containers. These combined systems are based on radiographers work by gamma-rays emitted from point source 60Co with 0.5 Ci activity and neutrons emitted from point isotopic sources of 252Cf and Pu- -Be as well as 14 MeV neutrons emitted from sealed tube neutron generator. The transmitted gamma ray through the inspected object was measured by gamma detection system with NaI(Tl) detector while the transmitted fast neutron beam was measured by a neutron gamma detection system with stilbene organic scintillator. The later possess the capability of discrimination between gamma and neutron pulses using a discrimination system based on pulse shape discrimination method. The measured intensities of primary incident and transmitted beams of gamma-rays and fast neutrons were used to construct 2D cross-sectional images of the inspected objects hidden directly within benign materials of the container and for object screened by high dense material to stop object detection by gamma or X-rays. The constructed images for the inspected objects show the good capability and effectiveness of the installed gamma and neutron radiographers to detect illicit materials hidden in air cargo containers and sea containers of med size. They have also indicated that the developed scanning systems possess the ease of mobility and low cost of scanning. Keywords: Cargo containers, gamma-rays, 14-MeV neutron generator, organic scintellator, 2D-cross-sectional image 1. Introduction In advertent movements of illicit materials such as explosives, chemical weapons, narcotics and radioactive materials in the form of radiation sources and contaminated metallurgical scrap have become a problem of increasing importance. Illicit trafficking in nuclear and other radioactive materials is not a new phenomenon, concern about a nuclear black market has increased in the last few years particularly in view of its terrorist potential. After the terrorism at September 11, 2001, the illicit materials have been the threaten thing to a human beings in a modern society, so the homeland security has been underlined more and more. A method of nuclear technique has been considered and developed as an inspection system [1,2]. At present, the normal inspection techniques are using X-ray which has the limitation of material specificity. Several features are required in nuclear based inspection system: deep penetration, high accuracy (low false alarm rate), specificity and practicality (cost, size). Nuclear techniques [3-11] using neutrons such as PFNA, TNA, FNSA, etc. are preferred because those can determine the contents of many of the light elements of interest, such as carbon, nitrogen, and oxygen. Some kind of commercial products using neutrons from proton or deuteron beam have been installed at an airport or a harbor. However, still these have some disadvantage in the aspect of cost and size [9].

A.M. Yousri et al. Armenian Journal of Physics, 2012, vol. 5, issue 1 Fast neutron radiography technique is an effective and a powerful tool for screening cargo for contraband such as narcotics, chemical weapons, and explosives. Neutrons have the required penetration, they interact with matter in a manner complementary to gamma-rays and they can be used to determine elemental composition. Compared to gamma ray radiography, neutron radiography systems are much more efficient especially in case for the detection of nuclear materials smuggling where the traditional methods like X-rays or gamma-rays radiography are fogging. In this work, the combined systems were installed in the feasibility condition of developing a low cost, fast and effective system to locate and distinguish explosive and illicit materials hidden in cargo containers of varied size and shape are given and discussed with more details in the next section [12]. 2. Experimental Setup and Measurements The installed combined systems consist of container manipulator system and radiography scanners. Figure 1 shows a schematic diagram for these systems. Brief descriptions of the combined systems are given below. Fig. 1. Schematic diagram of the radiologic scanner. 2.1. Container Manipulating System The system consists of a transfer table that moves on a steel frame by step motor. The inspected container is fixed on a transfer table which can be moved between radiation source/sources and detector/detectors in step increment that can be varied from 0.05 mm to 100 mm. The system works as well in continuous mode in the backward and forward directions. The movement increment and time of measurements are changed and adjusted by a control unit. 2

Scanning of Cargo Container Armenian Journal of Physics, 2012, vol. 5, issue 1 2.2. Gamma and Fast Neutron Radiographers In this section, development, adaptation and implementation of radiographers based on measuring the transmitted photons and/or neutrons emitted from different sources are given and discussed. This objective was achieved by gamma or fast neutron radiography methods to locate the position of hidden object. A brief description of the installed gamma and fast neutron radiographer systems are given below 2.3. Gamma-Ray Scanner A gamma scanner based on using slit beam of gamma-rays emitted from 60Co source of 0.5 Ci activity was built and tested. The source was fixed in a lead shield with horizontal channel where gamma-ray collimators of different geometries can be inserted to have gamma-ray beams of different geometries. The gamma-rays transmitted through the inspected container are measured by a NaI(Tl) detector housed in lead shield with central slit collimator fixed in front of the detector lead shield to enhance the spatial resolution of the 2D image constructed from the transmitted gamma beam. The output signals of NaI(Tl) detector were amplified and fed to the input of a radiation analyzer to only count signals of gamma-rays of energy ranges from 1.1 to 1.4 MeV. The output of scan is fed to a counter/timer NIM module type, Ortec 776, and its output is fed to the input of a PC for signal processing and image reconstruction. 2.4. Fast Neutron Scanner To improve the scanner workability for detection of objects hidden within thick and high dense materials, a fast neutron radiography system was installed and tested. This system works by using slit collimated beam of fast neutrons of 10 mm width and 20 mm height emitted from 14 MeV neutron generator, Pu-α-Be and 252Cf neutron sources. The transmitted fast neutron beam was measured by a neutron/gamma spectrometer with stilbene scintillator coupled to PMT fixed in high density polyethylene shield with slit opening of the same dimension of the incident neutron beam. The method PSD was applied to achieve discrimination between neutron and gamma peaks. To have a good quality image by fast neutron radiography a fast neutron source with high emission rate and neutron detector of high efficiency must be used. These two requirements could not be achieved in the installed fast neutron radiography scanner which uses a 5 Ci Pu-α-Be source and organic scintillator with efficiency ~ 20% for neutrons of average energy ~4 MeV. The incident fast neutron flux was enhanced by surrounding the Pu-α-Be source directly with lead of spherical shape to work as fast neutron reflector. The fast neutron count rate given by the neutron gamma spectrometer was only measured for fast neutrons of energies higher than 3 MeV to avoid artifact in the 2D image due to neutron 3

A.M. Yousri et al. Armenian Journal of Physics, 2012, vol. 5, issue 1 multiple scattering. Figure 2 shows the circuit diagram of neutron/gamma spectrometer used to measure fast neutron transmitted through the inspected container. 2.5. Image Reconstruction from Fan-Beam Projected Data Assuming a narrow beam geometry in which the scattered radiation dose not reach the detector, the transmission of photons/neutrons through an object of density ρ (g/cm 3 ) and thickness X can be calculated using the attenuation relation: where In (1) x Ie 0 I n is the measured photons or neutrons intensity through the object across X and Y-directions, and the subscript n are refer to the pixel number ( n 1, 2, 3, ), I 0 is the incident measured photons or neutrons intensity (the container removes), and is the gamma mass attenuation coefficient. The measured photons or neutrons transmitted through the inspected object carry most of the information about shape and density of the suspected object. For each pixel the quantities 0 R ln I I is calculated to construct a two-dimensional image with different color zones using n MATLAB program. A hot zone indicated a high density materials or hidden (shielded) organic materials. 3. Results and Discussion 2D images and its projections for ATM with 2.5 kg explosive material hidden in a container filled with foam and other foregoing materials such as rice or ceramic powder are constructed from the measured transmitted gamma-rays and fast neutrons using the MATLAB program. Measurements were performed with a bare object and with the object hidden in rice as a foregoing material and screened in a steel box with a wall thickness of 1 cm. 3.1. Gamma Scanning Figure 2 show the constructed images and its projections for bare, shielded with rice and steel screened ATM and hidden inside a cargo container. The displayed images give a good indication about the position of the hidden object inside the container. 3.2. Fast Neutron Scanning Neutron radiographs of bare ATM, shielded with rice and ATM screened with steel and hidden inside a cargo container are given in Figs. 3 and 4 using 14 MeV neutrons and fast neutrons emitted from Pu-α-Be respectively. The displayed images indicate the good detection capability of the neutron scanner using fast neutrons emitted from radio-isotopic sources. They also indicate that 4

Scanning of Cargo Container Armenian Journal of Physics, 2012, vol. 5, issue 1 the images obtained with the Pu-α-Be neutron source are nearly of the same quality as those obtained by 14 MeV neutrons. Fig. 2. Spatial distribution and 2D-images constructed from gamma ray scanning of ATM bare, shielded with rice and screened with steel box of 1 cm thick hidden inside cargo container. Fig. 3. Spatial distribution and 2D-images constructed from 14-MeV neutron generator scanning of ATM bare, shielded with rice and screened with steel box of 1 cm thick hidden inside cargo container. 5

A.M. Yousri et al. Armenian Journal of Physics, 2012, vol. 5, issue 1 Fig. 4. Spatial distribution and 2D-images constructed from Pu-Be neutron source scanning of ATM bare, shielded with rice and screened with steel box of 1 cm thick hidden inside cargo container. 4. Conclusions and Recommendations The installed Radiological scanner can work with either gamma or fast neutron radiography technique. This scanner proves a good imaging capability to locate position of contraband materials hidden in cargo containers, and show nearly the same effectiveness. The obtained results indicated that, the use of Pu- -Be fast neutrons to radiograph objects gives nearly the same image quality obtained by 14 MeV neutrons. The effectiveness of scanners working with isotopic fast neutron source can be enhanced to ~40% if the source is surrounded by a fast neutron reflector made of steel. An integrated system include this scanner and neutron identifier working with only one Pu- -Be neutron source possesses highly effective and accurate system to detect and identify different types and shapes of hidden contraband materials. To improve the scanning workability and reduce the container scanning time, neutron source of high emission rate ~ 1010 n/s and array of fast neutron detectors with higher detection efficiency should be used. Further investigations have to be performed to check the effectiveness of the installed combined system for locating and identifying fertile and fissile materials hidden in cargo containers. REFERENCES 1. T.Gozani, A review of neutron based non-intrusive inspection techniques, Hoover Institute National Security Forum, 12-13 March, Stanford University, 2002, http//:www-hoover.stanford.edu/reseach/ conferences/nsf02/agenda. 6

Scanning of Cargo Container Armenian Journal of Physics, 2012, vol. 5, issue 1 2. D.R.Brown, Combined technology for cargo security, the 2005 US Maritime Security Expo, www.maritimesecurityexpo.com/whitepapersarticles.html. 3. C.Overley, et al., Nucl. Instr. and Meth. B, 99, 728 (1995). 4. C.L.Fink, et al., Nucl. Instr. and Meth. B, 99, 748 (1995). 5. G.Vourvopoulos, F.J.Schultz, Nucl. Instr. and Meth. B, 79, 585 (1993). 6. L.Grodzins, Nucl. Instr. and Meth. B, 79, 597 (1993). 7. P.Sawa, Nucl. Instr. and Meth. B, 79, 593 (1993). 8. J.Rynes, et al., Nucl. Instr. and Meth. A, 422, 895 (1999). 9. A.Buffler, Ninth International Symposium on Radiation Physics (ISRP-9) and Workshop on Radiation Based Analytical Technology, 24 31 October, Cape Town (2003). 10. J.Csikai, R.Doczi, B.Kiraly, Detection of illicit traffic materials using neutrons, Private Communication, 2002. 11. T.Gozani, et al., Sea VEDS-nonintrusive of maritime vessels for concealed drugs, ONDCP International Technology Symposium Proceedings, Washington, D.C, 8 10, March, 1999. 12. R.M.Megahid, A.M.Osman, W.A.Kansouh, Neutron Based Techniques for the Detection of Illicit Materials and Explosives, Satellite Meeting held within the framework of the IAEA International Topical Meeting on Nuclear Research Applications and Utilization of Accelerators, 4 8 May, Vienna, Austria, 2009. 7