Cation Exchange HPLC Columns

Similar documents
Cation Exchange HPLC Columns

groups I and II cations, amines, divalent transition metals

HPLC Columns and Accessories. Solutions for liquid chromatography

IC Columns Introduction

HPLC Columns and Accessories. Solutions for liquid chromatography

Anion Exchange HPLC Columns

Dionex IonPac AS28-Fast-4µm column

columns IonPac SCS 1 Silica Cation Separator

Saccharides and Organic Acids

HPLC. Columns and Resins. For a Complete Range of Applications

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Method Development with ZirChrom's Ion Exchange Phases

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

Packings for HPLC. Packings for HPLC

columns IonPac AS17-C Anion Exchange Column

ProPac WCX-10 Columns

HPLC COLUMNS. HPLC Columns & Bulk Resins THE MEASURE OF EXCELLENCE TM

1. Ion exchange chromatography

High Performance Liquid Chromatography

High Performance Liquid Chromatography

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Luminescence transitions. Fluorescence spectroscopy

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Shodex TM ODP2 HP series columns

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

columns IonPac AS18 Anion-Exchange Columns

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

columns IonPac AS22 Anion-Exchange Column

Acclaim Mixed-Mode WCX-1

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Thermo Scientific. Anion-Exchange Column

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

Liquid Chromatography

Liquid Chromatography


Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Acclaim Mixed-Mode WAX-1 Columns

High-Performance Chromatography Superior isocratic separation of

Advantages of polymerbased. an alternative for ODS

for Acclaim Mixed-Mode WCX-1

High Pressure/Performance Liquid Chromatography (HPLC)

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography

Too Polar for Reversed Phase What Do You Do?

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

BRIEFING. (EXC: K. Moore.) RTS C Propylparaben C 10 H 12 O Benzoic acid, 4 hydroxy, propyl ester; Propyl p hydroxybenzoate [ ].

Biochemistry. Biochemical Techniques HPLC

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

penta-hilic UHPLC COLUMNS

for Acclaim Mixed-Mode HILIC-1 Column

LC and LC/MS Column Selection Flow Chart

GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents

penta-hilic UHPLC COLUMNS

ION CHROMATOGRAPHY SYSTEM S 150

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

It s hot! ZIC -chilic

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

Theory of Ion Chromatography

The Analysis of Organic Acids in Foods and Beverages Using Reversed Phase HPLC

PRODUCT MANUAL OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N ) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N )

Expanded capabilities in ammonium and amine detection

anion-exchange column

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Ion Chromatography (IC)

GFC Analysis of Water-Soluble Polymers with TSKgel PW-type Columns. Contents

Reversed Phase Solvents

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Overcoming Challenging Matrices in Ion Chromatography

Chapter content. Reference

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Polymer analysis by GPC-SEC. Technical Note. Introduction

IC5000 Ion Chromatography System

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Shodex. Catalogue 9. Hichrom Limited

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

Hints for Strong Ion Exchange Resins

Open Column Chromatography, GC, TLC, and HPLC

Eternity. Kromasil EternityXT. Designed for extended lifetime

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

C190-E105 Printed in Japan ATD

GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI

Acclaim HILIC-10 Columns

GC Instruments. GC Instruments - Columns

Determination of trace anions in concentrated hydrofluoric acid

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Optimizing GPC Separations

Transcription:

Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb + Inorganic and organic cations using conductivity or UV detection, alkali and alkaline earth metals. Separate mono or divalent cations depending on mobile phase conditions from 0 ppb to 00 ppm. Glyphosate and its metabolite in drinking water Organic and inorganic cations using conductivity or UV detection Transition metals or mono and divalent cations in the same run Oligo saccharides up to DP8 Mono and disaccharides Organic acids, sugars and alcohols Sugar alcohols and plant cell wall hydrolysates In cation exchange chromatography, the stationary bed has an ionically negative (-) charged surface while the sample ions are of positive (+) charge. This technique is used almost exclusively with ionic or ionizable samples. The stronger the positive (+) charge on the sample, the stronger it will be attracted to the negative charge on the stationary phase, and thus the longer it will take to elute. The mobile phase is an aqueous buffer, where both ph and ionic strength are used to control elution time. Ion chromatography can employ harsh conditions requiring mobile phases that are at very high ph limits (> ). Temperatures well above the normal operating conditions where silica materials fail can also be used.

PRP-X00 Columns High resolution separation of alkali and alkaline earth metals Pore Size: 00 Å Material: PS-DVB/Sulfonic acid exchanger Exchange Capacity: µeq/gm PRP-X00 stationary phase structure and applications Inorganic and organic cations using conductivity or UV detection, alkali and alkaline earth metals. Separate mono or divalent cations depending on mobile phase conditions from 0 ppb to 00 ppm. Examples of analytes that can be separated on PRP-X00 columns: Hamilton PRP-X00 cation exchange HPLC columns are designed for rapid, high resolution separation of alkali and alkaline earth metals. The alkali metals and ammonium are completely resolved in less than five minutes, and the alkaline earth cations separate in under four minutes. Since the mobile phase conditions are different and unique for each of the groups of cations, interferences between these groups are eliminated. The resolution between any two ions in the alkali metal series can be increased or decreased by changing the concentration of methanol in the mobile phase. This unique feature of the PRP-X00 mobile phase/stationary phase interaction allows the chromatographer to focus on the particular ion of interest and reduce possible interference from other ions in the sample. The stationary phase is a sulfonated poly (styrene-divinylbenzene), so it is stable to all concentrations of organic modifiers as well as strong acids and bases. The rigid spherical polymer phase allows operation up to,000 psi. The PRP-X00 columns are designed for use in all of today s ion chromatographic equipment. Since exchange capacity is low, background signal is low. This allows low detection limits at the highest conductivity detector settings. XXCalcium XXCesium XXPotassium XXSodium PRP-X00 application chromatograms Monovalent Cations on PRP-X00 Need a custom method? The Hamilton HPLC team is happy to help design your unique application. Give us a call to learn more. The 0 mm column is ideal for rapid analysis, while the 0 mm column is recommended for higher resolution or for analysis of minor components in the presence of major interferences. PRP-X00 Column Ordering Information Dimensions Particle Size Column: PRP-X00, μm,. mm x 0 mm Part number: 79 Mobile phase: (.:) mm Nitric acid:methanol Flow rate: ml/min Temperature: Ambient Injection volume: 00 μl Detection: Conductivity. Lithium. Sodium. Ammonium. Potassium. Cesium 0 µm 0 µm. x 0 mm 799. x 00 mm 796. x 0 mm 79. x 0 mm 79.6 x 0 mm PEEK 798.6 x 0 mm PEEK 797 Bulk Resin ( Gram) 7987 7988 6

PRP-X00 Columns Excellent separation of glyphosate and its metabolite in drinking water Pore Size: 00 Å Material: PS-DVB/Sulfonic acid exchanger Exchange Capacity:. meq/gm The PRP-X00 column provides a fast separation for glyphosate and its metabolites. The exchange capacity of the PRP-X00 is greater than that of the PRP-X00, leading to characteristics better suited for the separation of glyphosate. It also performs well in other separations, such as inositol and sugar alcohols. The column does not have to be heated to 6 C and operates well at room temperature, so a column heater is not necessary for this method. PRP-X00 columns do not require the use of methanol in the mobile phase, and they cost much less than other glyphosate columns. PRP-X00 application chromatograms Glyphosate on PRP-X00 PRP-X00 Column Ordering Information Dimensions Particle Size 7 µm 0 µm 0 0 µm. x 0 mm 7998. x 0 mm 7977. x 0 mm 797.6 x 0 mm PEEK 7987 Bulk Resin ( Gram) 799 799 799 The PRP-X00 is a 7 µm poly(styrene-divinylbenzene) sulfonated cation exchange support (. meq/gm) column. It separates glyphosate and aminomethylphosphonic acid according to charge in less than 0 minutes. This separation requires post-column oxidation and derivatization. Post column reaction (oxidation) with calcium hypochlorite followed by derivatization with o-phthalaldehyde solution provides sensitive (6 ppb or lower) and selective (primary and secondary) amine detection. PRP-X00 stationary phase structure and applications Glyphosate and its metabolite in drinking water. The PRP-X00 provides unique hydrophilic interaction separations. Cations, inorganic and organic using conductivity or UV detection. Column: PRP-X00, μm,. mm x 0 mm Part number: 797 Mobile phase: 0.00 M Monobasic potassium phosphate Flow rate: 0. ml/min Temperature: Ambient Injection volume: 00 μl Detection: Excitation wavelength 8 nm, Emission wavelength nm. Glyphosate. Aminomethylphosphonic acid Examples of analytes that can be separated on PRP-X00 columns: XXGlyphosate XXMaltose XXXylitol XXMannitol For full details on how to use the PRP-X00 for glyphosate analysis, please visit our website at www.hamiltoncompany.com/hplc. 8

PRP-X800 Columns Separates transition metals or mono and divalent cations in the same run Pore Size: 00 Å Material: PS-DVB/Itaconate exchanger (WCX) Exchange Capacity:.6 meq/gm The PRP-X800 is a polymeric cation exchange column functionalized with itaconic acid that performs the isocratic separation of mono and divalent cations such as lithium, sodium, ammonium, potassium, magnesium and calcium. The column offers excellent durability, is stable to any concentration organic solvent, and enables dynamic control of exchange capacity. Detection is via conductivity or indirect UV, depending on the mobile phase. PRP-X800 application chromatograms Mono and Divalent Cations on PRP-X800 PRP-X800 Column Ordering Information Dimensions Particle Size: 7 µm. x 0 mm 798. x 0 mm 7988 From autosampler syringes to manual injection and more, Hamilton has the chromatography syringe you need. View the full portfolio of HPLC, GC and TLC syringes at www.hamiltoncompany.com/syringes. PRP-X800 stationary phase structure and applications Mono and divalent transition metals in the same run. Transition metals (e.g., manganese, zinc, cobalt and cadmium) are also resolved on the column using an ethylenediamine/tartaric acid mobile phase and conductivity detection. Examples of analytes that can be separated on PRP-X800 columns: XXMono and divalent metal cations (e.g., sodium, potassium, calcium) XXTransitions metals (e.g., iron, manganese, nickel, copper, zinc) Column: PRP-X800, μm,. mm x 0 mm Part number: 7988 Mobile phase: mm Cupric Sulfate Flow rate: 0.8 ml/min Temperature: Ambient Injection volume: 0 μl Sample concentration: All compounds are ppm Detection: Indirect UV at 0 nm. Lithium. Sodium. Ammonium. Potassium. Magnesium 6. Calcium 6 The PRP-X800 is available in PEEK hardware as a custom order. Please see page 8 for more information. 0

HC-0 Ca + and HC-7 (H +, Ca +, Pb + ) Columns Separate compounds through size exclusion and ligand exchange Pore Size: 00 Å Material: PS-DVB/ Sulfonic acid exchanger Exchange Capacity: meq/gm The HC-0 and HC-7 group of columns consist of four different packing types, each with a different retention characteristic and application. They are: XXHC-0 Oligo saccharides up to DP8 (e.g., corn syrup, high conversion corn syrup, beer) XXHC-7 Calcium Form Separates mono and disaccharides (e.g., corn syrup, chewing gum sweeteners, milk product sugars, glycols and polyols, high fructose corn syrup, juices, oligosaccharides) XXHC-7 Lead Form Sugar alcohols and plant cell wall hydrolysates XXHC-7 Hydrogen Form Organic acids, sugars and alcohols HC-0 and HC-7 stationary phase structure and applications Carbohydrates, sugar oligomers up to DP8. Mono and disaccharides, organic acids, sugars, and sugar alcohols. Examples of analytes that can be separated on HC-0 and HC-7 columns: XXEthanol XXMaltohexose citric acid XXGlucose fructose XXArabinose XXSorbitol XXAcetic acid Pb +, H + or Ca + HC-0 and HC-7 columns separate compounds through size exclusion and ligand exchange. The % cross-linked HC-0 uses size exclusion as the primary mechanism of separation, while ligand exchange dominates in the more highly cross-linked HC-7. The different forms of the HC-7 (Hydrogen, Calcium and Lead) each provide a unique selectivity for separating varying types of charged analytes based on electronegativity toward the counterion. The higher carbohydrate oligomers elute first while the smaller di- and monosaccharaides elute later. The HC-7 column provides a slightly faster -minute separation up to DP, and the HC-0 column provides a much better separation of the oligomers up to DP 8 in 6 minutes. Because carbohydrates do not contain a chromophore, UV detection cannot be used without derivatization. The recommended detection method is refractive index. The control of carbohydrate retention lies in the selection of the correct column. The HC-0 and HC-7 columns use water as a mobile phase (gradients and salts are not required), which simplifies eluent preparation and minimizes cost. This mobile phase characteristic also lends these columns to detection techniques such as evaporative light scattering detection and mass spectrometry. A very versatile column family, the HC-7 group can be used with up to 0% acetonitrile and can be regenerated to help restore performance.

HC-7 application chromatograms HC-7 and HC-0 Column Ordering Information Chewing Gum Sugars on HC-7 Ca + Organic Acids by USP L7 on HC-7 H + Dimensions HC-7 Particle Size HC-0 9 µm 9 µm (H + ). x 0 mm 7976 (H + ) 7.8 x 00 mm 797 (H + ) 7.8 x 0 mm 79 (H + ) Bulk Resin ( Gram) 797 (Ca + ). x 0 mm 79 (Ca + ) 7.8 x 0 mm 796 (Ca + ) Bulk Resin ( Gram) 79709 79707 (Pb + ) 7.8 x 00 mm 790 (Pb + ) 7.8 x 0 mm 798 (Pb + ) Bulk Resin ( Gram) 797 Column: HC-7 Calcium Form, μm, 7.8 mm x 0 mm Part number: 796 Mobile phase: Deionized water. Flow rate:. ml/min Temperature: 90 C Injection volume: μl Detection: Refractive index. Sucrose. Glucose. Fructose. Mannitol. Sorbitol Column: HC-7 Hydrogen Form, μm,. mm x 0 mm Part number: 7976 Mobile phase: 0.0 N sulfuric Flow rate: 0. ml/min Temperature: 60 C Injection volume: 0 μl Sample concentration: All compounds are 0 ppm Detection: UV at 0 nm. Citric acid. Lactic acid. Acetic acid Sugar Standards on HC-7 Pb + Column: HC-7 Lead Form, μm, 7.8 mm x 0 mm Part number: 798 Mobile phase: Deionized water Flow rate: 0.6 ml/min Temperature: 80 C Injection volume: 00 μl Sample concentration: All compounds are. mg/ml Detection: Refractive index. Sucrose. Glucose. Fructose. Inositol. Sorbitol