Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

Similar documents
Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

columns IonPac AS17-C Anion Exchange Column

Dionex IonPac AS28-Fast-4µm column

columns IonPac SCS 1 Silica Cation Separator

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Thermo Scientific. Anion-Exchange Column

High-Performance Chromatography Superior isocratic separation of

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

columns IonPac AS18 Anion-Exchange Columns

columns IonPac AS22 Anion-Exchange Column

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

anion-exchange column

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Expanded capabilities in ammonium and amine detection

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

PRODUCT MANUAL. for the. IONPAC CG14 GUARD COLUMN (2 x 50 mm, P/N ) (4 x 50 mm, P/N )

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Determination of trace anions in concentrated hydrofluoric acid

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Determination of Methylamine in Drug Products

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Utility of the Charge Detector in Ion Chromatography Applications

IonPac Trace Cation Concentrator

Determination of urea in ultrapure water by IC-MS/MS

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

IonPac SCS 1 IonPac SCG 1

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Product Manual for Dionex IonPac CS12A and CG12A Columns

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

suppressors Eluent Suppressors for Ion Chromatography

Cation Exchange HPLC Columns

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Determination of Inorganic Cations and Ammonium in Environmental Waters by Ion Chromatography Using the IonPac CS16 Column

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

ProPac WCX-10 Columns

Determination of Trace Anions in Organic Solvents

suppressors SRS -ULTRA Self-Regenerating Suppressor

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Thermo Scientific Dionex eluent suppressors for ion chromatography

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

Monitoring Protein PEGylation with Ion Exchange Chromatography

Advances in Sample Preparation for Accelerated Solvent Extraction

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities

[ Care and Use Manual ]

Overcoming Challenging Matrices in Ion Chromatography

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

PRODUCT MANUAL OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N ) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N )

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Determination of Inorganic Anions in Wastewater by Ion Chromatography

groups I and II cations, amines, divalent transition metals

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

PRODUCT MANUAL. OMNIPAC PAX-100 GUARD COLUMN (4 x 50 mm, P/N ) OMNIPAC PAX-500 GUARD COLUMN (4 x 50 mm, P/N )

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

The Determination of Trace Anions in Concentrated Phosphoric Acid

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

Inline sample preparation for the determination of anions in sodium hydroxide

Determination of Trace Cations in Concentrated Acids Using AutoNeutralization Pretreatment and Ion Chromatography

User Manual. IonPac NS1 Columns Revision 07 November For Research Use Only. Not for use in diagnostic procedures.

for IonPac AG11-HC IonPac AS11-HC

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Determination of trace anions in high-nitrate matrices by ion chromatography

Enhancement of Linearity and Response in Charged Aerosol Detection

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

HILIC Method Development in a Few Simple Steps

Transcription:

chromatography Obtain excellent peak shapes for hydrophobic amines without the use of solvent using the Dionex IonPac CS CationExchange Column. Product Specifications Thermo Scientific Dionex IonPac CS CationExchange Column Separation of Alkylamines and the Group I and II Cations Using the Dionex IonPac CS Column.0 9 0 Peaks:. Lithium 0.0 mg/l (ppm). Sodium 0.0. Ammonium 0.. Potassium 0.. Ethylamine 0.0. tertbutylamine.. secbutylamine. 9. isobutylamine. 0. nbutylamine..,dimethylpropylamine.00. Dinpropylamine.00. Magnesium 0.. Calcium 0. 0.0 0 0 0 0 The Dionex IonPac CS cationexchange column is designed for the separation of hydrophobic and polyvalent aminesincluding biogenic amines, alkylamines and diaminesusing simple aqueous eluents and elevated temperatures. This column offers improved peak shape for most Dionex IonPac CS, CS amd CS amine applications without the use of solvent. The Dionex IonPac CS column is a universal column for the separation of polyvalent and hydrophobic amines in complex sample matrices. Minimal baseline shifts and enhanced analyte sensitivity are obtained using the Thermo Scientific Dionex Cation SelfRegenerating Suppressor (CSRS 00) or Thermo Scientific Dionex Cation Capillary Electrolytic Suppressor (CCES 00). Operation is simplified with ReagentFree IC provided by the Eluent Generator (EG), which requires only a deionized water source to produce methanesulfonic acid (MSA) eluent. Sample matrices include environmental waters, power plant waters treated with ammonium, morpholine, or ethanolamine, chemical additives, chemical process solutions, scrubber solutions, plating baths and solvents. The Dionex IonPac CS is available in standard bore, microbore and capillary formats allowing flow rates from. ml/min to 0 µl/min. The capillary format offers increased mass sensitivity, reduced eluent consumption and the ability to operate on demand. Part of Thermo Fisher Scientific

Dionex IonPac CS CationExchange Column Highlights Separation of polyvalent and hydrophobic amines in complex sample matrices without the use of solvent Improved peak shapes over the Dionex IonPac CS, CS and CS applications using simple aqueous gradients Available in standard bore, microbore and capillary formats Unique Carboxylate Cation Exchanger The Dionex IonPac CS column is a unique, hydrophilic, moderate capacity carboxylatefunctionalized cation exchanger that provides excellent selectivity and peak shape for amines. Figure shows the resin bead structure of the Dionex IonPac CS. The resin bead consists of a highly crosslinked core. The substrate for this column is a macroporous resin bead ( µm diameter) consisting of ethylvinylbenzene, crosslinked with % divinylbenzene. The Dionex IonPac CS resin bead is produced using a novel grafting technology. This new technology employs a grafted nonfunctional coating on the resin surface and pores with the cationexchange polymer grafted onto this nonfunctional coating. This novel technology reduces hydrophobic interactions with the analytes and resin surface, resulting in excellent mass transfer characteristics which provides very high efficiency peaks. The Power of Gradient Elution Figure illustrates improved resolution among adjacent peaks using gradient or stepchange elution instead of isocratic elution. Gradient elution improves the resolution among the first five eluting peaks, the four monovalent cations, and dimethylamine. By using the EG, a Thermo Scientific Dionex Cation Trap Column (Dionex CTC) or Thermo Scientific Dionex Continuously Regenerated Cation Trap Column II (Dionex CRCTC II) and the Dionex IonPac CS column, the baseline shift is minimal when stepping from a low to high eluent concentration, thus providing simplified peak integration and quantification of the analytes. Moderately hydrophobic amines, such as triethylamine, can be eluted efficiently without addition of organic solvent to the eluent. Figure. Structure of a Dionex IonPac CS packing particle. r =. m Macroporous Polymeric Substrate Surface Area = 0 m /g Figure. Separation of Group I and II cations and methylamines using a stepchange elution and the Dionex IonPac CS column. Column: Eluent: A. Eluent B: Flow Rate: Sample Volume: µl Temperature: 0 C. 0.. A B Dionex IonPac CS, mm mm Methanesulfonic acid (MSA) mm MSA isocratic to.0 min; step change to mm MSA at. min; isocratic to min; step change back to mm MSA at. min Equilibration time is min.0 ml/min Suppressor: Dionex Cation Atlas Electrolytic Suppressor in AutoSuppression Recycle Mode, ma Peaks:. Lithium 0. mg/l (ppm). Sodium 0.. Ammonium 0.. Potassium.0. Dimethylamine.0. Triethylamine.0. Magnesium 0.. Calcium.0 9 0. 0 0 0 9

CS Capillary Format The Dionex IonPac CS Capillary column (0. 0 mm) is packed with the same material as the equivalent analytical scale version, thereby producing the same performance as a mm column while requiring only /00th the eluent flow rate. The capillary format offers the advantage of reduced eluent consumption which means reduced operating costs and the ability to operate "on demand". Figure illustrates the separation of the common inorganic cations using the Dionex IonPac CS Capillary Column. Excellent retention time reproducibility can be achieved with the capillary format. Determination of Biogenic Amines and Group I and II Cations Biogenic amines including putrescine, cadaverine, spermine, spermidine, and histamine are indicators of food spoilage. As illustrated in Figure, the Dionex IonPac CS column can easily separate the biogenic amines and Group I and II cations using an aqueous eluent without added organic solvent. Good peak efficiencies and symmetries are shown when the column is operated with a simple acidic gradient at elevated temperature. Biogenic amines can easily be determined in complex food matrices using the Dionex IonPac CS column with suppressed conductivity detection. Amperometric detection can also be used to detect these compounds. This detection mode provides improved specificity for oxidizable amines, including the biogenic amines. Inorganic cations present in the sample are not detected using this method, and high concentrations do not interfere with the quantification of the amines. Figure. Separation of Common Cations, Ammonium and Amines Using the Dionex IonPac CS Capillary Column Column: Dionex IonPac CS, 0. mm Eluent: mm MSA Eluent Source: Dionex EGCMSA (Capillary) Flow Rate: 0.00 ml/min Inj. Volume: 00 nl Temperature: 0 C Detection: Suppressed conductivity, Dionex CCES 00, AutoSuppression, recycle mode 0 Peaks:. Lithium 0.0 mg/l. Sodium 0.0. Ammonium 0.. Potassium 0.0. Dimethylamine 0.0. Triethylamine.0. Magnesium 0.. Calcium 0.0 0 0 Figure. Determination of biogenic amines and the Group I and II cations using the Dionex IonPac CS column. Column: Eluent: Dionex IonPac CG, CS, mm mm MSA isocratic to. min; mm to mm MSA gradient at min; isocratic to min; gradient to 0 mm MSA at 0 min, isocratic to min; step change back to mm MSA at. min Equilibration time is min Flow Rate: 0.0 ml/min Sample Volume: µl Temperature: 0 C Suppressor: Dionex CSRS ULTRA mm Cation SelfRegenerating Suppressor, AutoSuppression Recycle Mode, 00 ma.0 Peaks:. Lithium 0 µg/l (ppb). Sodium 0. Ammonium 0. Potassium 00. Magnesium 0. Calcium 00. Putrescine 000. Cadaverine 00 9. Histamine 00 0. Spermidine 00. Spermine 00 9 9 0 0. 0 0 0 0

Dionex IonPac CS CationExchange Column Determination of Amine Additives in Power Plant and Boiler Waters Ethanolamine is one of the most widely used corrosion prevention additives in power plant waters. Hydrazine, (H NNH ) is a powerful reducing agent used in the power industry as an oxygen scavenger to reduce turbine corrosion present in µg/l (ppb) concentrations. The moderate capacity, hydrophilic Dionex IonPac CS column solves the difficult resolution problem of separating hydrazine from ammonium and ethanolamine. Morpholine, diethylaminoethanol, and cyclohexylamine are added to water as vaporphase corrosion inhibitors in steamgenerating plants and for other boiler applications. Concentrations of these amines must be monitored to maintain optimum levels. Using the Dionex IonPac CS column with suppressed conductivity, separation, detection, and quantitation of these amines are easily achieved using an MSA gradient at elevated temperature, as illustrated in Figure. Determination of Alkanolamines in Power Plant Waters and Scrubber Solutions Alkanolamines including mono, di, and triethanolamine are most commonly used individually or in any combination to optimize the efficiency of the scrubber treatment for a specific chemical process. In large plants, different alkano lamines may be used in adjacent units as tracers for leakage problems. The Dionex IonPac CS column resolves all combinations of these scrubber amines using a methanesulfonic acid gradient and elevated temperature (See Figure ). Figure. Determination of power plant amine additives using the Dionex IonPac CS column. Column: Dionex IonPac CG, CS, mm Eluent: 0. mm to 0. mm MSA gradient at min; step change to mm MSA at. min; isocratic to min; step change to. mm MSA at. min; isocratic to min; step change back to 0. mm MSA at. min Equilibration time is min Flow Rate: 0. ml/min Sample Volume: µl Temperature: 0 C Suppressor: Dionex Cation Atlas Electrolytic Suppressor in AutoSuppression Recycle Mode, ma.0 0 Peaks:. Lithium µg/l (ppb). Sodium 00. Ammonium. Hydrazine 000. Ethanolamine 0. Potassium 0. (aminoethoxy) ethanol 000. aminopentanol 00 9. Morpholine 000 0. diethylamino ethanol 000. Cyclohexylamine 000. Magnesium. Calcium 0 0 0 0 0 0 Figure. Determination of alkanolamines using the Dionex IonPac CS column. Column: Dionex IonPac CS, mm Peaks:. Lithium 0. mg/l (ppm) Eluent: 0. mm to 0. mm MSA gradient. Sodium 0. at min; step change to 9 mm MSA. Ammonium 0. at. min; isocratic to min;. Ethanolamine 0. step change back to 0. mm MSA. Potassium.0 at. min. Diethanolamine.0 Equilibration time is min. Triethanolamine.0 Flow Rate:. ml/min. Magnesium 0. Sample Volume: µl 9. Calcium.0 Temperature: 0 C Suppressor: Dionex Cation Atlas Electrolytic Suppressor in AutoSuppression Recycle Mode, ma. 9 0 9.0 0 0 0 0

Determination of Alkylamines and the Group I and II Cations Lithium, sodium, ammonium, potassium, magnesium and calcium and lowmolecularweight alkylamines can be easily separated using an organic solventfree eluent. The alkylamines elute with good peak efficiencies and symmetries using a simple acidic gradient and elevated temperature, as illustrated in Figure. Determination of Diamines in Complex Sample Matrices The unique hydrophilic cationexchange surface of the Dionex IonPac CS column allows the separation of lithium, sodium, ammonium, potassium, magnesium and calcium, and alkyl diamines with an organic solventfree eluent. The diamines elute after the six common cations with good peak efficiencies and symmetries using a simple acidic gradient and elevated temperature. Figure illustrates the excellent selectivity for the diamines. Despite the gradient change from mm to 0 mm methanesulfonic acid, the baseline shift is undetected. Alkyl diamines larger than,0decanediamine are not soluble in aqueous solutions, and therefore require the addition of organic solvent to the eluent when they are present in the sample. Figure. Separation of alkylamines and the Group I and II cations using the Dionex IonPac CS column. Column: Dionex IonPac CG, CS, mm Eluent: 0. mm to. mm MSA gradient at min; gradient to. mm MSA at min; gradient to 0 mm MSA at min; isocratic to min; step change back to 0. mm MSA at. min Equilibration time is min Flow Rate: 0.0 ml/min Sample Volume: µl Temperature: 0 C Suppressor: Dionex Cation Atlas Electrolytic Suppressor in AutoSuppression Recycle Mode, ma.0 0.0 0 0 Peaks:. Lithium 0.0 mg/l (ppm). Sodium 0.0. Ammonium 0.. Potassium 0.. Ethylamine 0.0. tertbutylamine.. secbutylamine. 9. isobutylamine. 0. nbutylamine..,dimethylpropylamine.00. Dinpropylamine.00. Magnesium 0.. Calcium 0. 9 0 0 0 Figure. Determination of diamines and the Group I and II cations using the Dionex IonPac CS column. Column: Eluent: Dionex IonPac CG, CS, mm mm MSA isocratic to. min; mm to mm MSA gradient at min; isocratic to min; gradient to 0 mm MSA at 0 min, isocratic to min; step change back to mm MSA at. min Equilibration time is min Flow Rate: 0.0 ml/min Sample Volume: µl Temperature: 0 C Suppressor: Dionex CSRS ULTRA mm Cation SelfRegenerating Suppressor, AutoSuppression Recycle Mode, 00 ma.0 A Peaks: A B. Lithium µg/l (ppb). Sodium. Ammonium 9. Potassium. Magnesium. Calcium. Ethylenediamine 00.,propanediamine 00 9.,hexanediamine 0 0. N,Ndiethylenediamine 00.,heptanediamine. N,N,N,Ntetramethylethylenediamine 00,octanediamine 0.,diaminopropylamine 00.,9nonanediamine.,0decanediamine 9 0.0 0.0 B 0 0.0 0 0 0

Dionex IonPac CS CationExchange Column SolventCompatible Packing The Dionex IonPac CS column is 00% solventcompatible, including alcohols. Adding solvent to the eluent modifies column selectivity and facilitates the elution of nonpolar analytes or contaminants from the column. Solvent can be used to enhance sample solubility, reduce retention times, and improve peak shapes of hydrophobic amines. Time and expense can be saved by eliminating timeconsuming sample preparation steps. This feature allows analysis of complex sample matrices with minimal preparation. System Recommendations The Dionex IonPac CS column in suppressed conductivity mode is recommended for use with the Thermo Scientific Dionex ICS00 or Thermo Scientific Dionex ICS000 equipped with an EG, or with older Dionex IC systems equipped with an EG or a Dionex RFC0 ReagentFree Controller. The eluent generator is used to automatically produce methanesulfonic acid gradients from deionized water. The Dionex CS capillary column requires the use of the Dionex ICS000 capillary system. Suppressors For optimum ease of use and performance, the Dionex IonPac CS analytical column can be used with the Dionex CSRS 00 and the Dionex IonPac CS capillary column can be used with the CCES 00. Cation Trap Columns When using the Eluent Generator, a Dionex CRCTC II Continuously Regenerated Cation Trap Column for concentration should be installed between the Eluent Generator cartridge and the Eluent Generator Degas Module. Alternately, a Dionex CTC Cation Trap column can be installed between the gradient pump and the injection valve to remove cationic contaminants from the eluent. Concentrator Columns For trace analysis, use the Dionex IonPac CG Guard Column when a singlepiston pump such as the Thermo Scientific Dionex AXP is used for sample delivery. Use one of the Thermo Scientific Dionex Trace Cation Concentrator columns (Dionex TCCLP, TCCULP, or TCCXLP) when using a syringe or autosampler. For concentrator work with a 0. mm capillary column, use the Dionex IonPac CG Capillary Guard Column or the Thermo Scientific Dionex MCC00 Concentrator Column.

Product Specifications Dimensions Maximum Operating Pressure Mobile Phase Compatibility SPECIFICATIONS Dionex IonPac CS Capillary Column: 0. x 0 mm Dionex IonPac CG Capillary Guard Column: 0. x 0 mm Dionex CS Analytical Columns: 0 mm and 0 mm Dionex CG Guard Columns: 0 mm and 0 mm 000 psi Substrate Characteristics Bead Diameter: µm Crosslinking (%DVB): % IonExchange Group Functional Group Characteristics Capacity Column Construction Acidic eluents, 00% HPLC solvents, including alcohols Grafted carboxylic acid Very low hydrophobic. µeq/column (0. 0 mm).9 µeq/column (0. 0 mm) 0 µeq/column ( 0 mm) 90 µeq/column ( 0 mm) µeq/column ( 0 mm) µeq/column ( 0 mm) PEEK with 0 threaded ferrulestyle end fittings. All components are nonmetallic. ORDERING INFORMATION To order in the U.S., call 0090, or contact the Thermo Fisher Scientific office nearest you. Outside the U.S., order through your local Thermo Fisher Scientific office or distributor. Refer to the following part numbers. Dionex IonPac CS Columns Part Number Dionex IonPac CS Analytical Column ( 0 mm) 00 Dionex IonPac CG Guard Column ( 0 mm) 000 Dionex IonPac CS Analytical Column ( 0 mm) 00 Dionex IonPac CG Guard Column ( 0 mm) 00 Dionex IonPac CS Capillary Column (0. 0 mm) 0 Dionex IonPac CG Capillary Guard Column (0. 0 mm) 0 Trap Columns Part Number Dionex CRCTC II Continuously Regenerated Cation Trap Column 0 Dionex CRCTC Continuously Regenerated Cation Trap Column (Capillary) (For use with Capillary Cation Columns) 009 Dionex CTC Cation Trap Column (9 mm) for use with the mm columns 009 Dionex CTC Cation Trap Column ( mm) for use with the mm columns 0 Cation Concentrator Columns Part Number Dionex TCCLP Low Pressure Trace Cation Concentrator ( mm) for use with the mm and mm columns 00 Dionex TCCULP Ultra Trace Cation ConcentratorUltra Low Pressure ( mm) 0 Dionex TCCXLP Ultra Trace Cation ConcentratorExtremely Low Pressure ( mm) 09 Dionex MCC00 Monolith Cation Concentrator Column (0. 0 mm) 0 www.thermoscientific.com/dionex Thermo Scientific Dionex products are 0 Thermo Fisher Scientific Inc. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. designed, developed, and manufactured under an ISO 900 Quality System. LPN 0 / Dionex Products: Titan Way, PO Box 0, Sunnyvale, CA 900, (0) 000 North America: U.S./Canada () 900 South America: Brazil () 0 Europe: Austria (), Benelux () 0 9 () 9, Denmark () 90 90, France () 9 0 0 0, Germany (9) 99 0, Ireland () 00, Italy (9) 0, Sweden () 0, Switzerland () 0 99, United Kingdom () 9 Asia Pacific: Australia () 90, China (), India (9), Japan (), Korea () 0, Singapore () 9 90, Taiwan ()