A label-free quantification method by MS/MS TIC compared to SILAC and spectral counting in a proteomics screen

Similar documents
NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

PC235: 2008 Lecture 5: Quantitation. Arnold Falick

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

Modeling Mass Spectrometry-Based Protein Analysis

Reagents. Affinity Tag (Biotin) Acid Cleavage Site. Figure 1. Cleavable ICAT Reagent Structure.

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

Quantitative Proteomics

Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 *

Amine specific Labeling Reagents for Multiplexed Relative and Absolute Protein Quantitation

Chapter 4. strategies for protein quantitation Ⅱ

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

Isotopic-Labeling and Mass Spectrometry-Based Quantitative Proteomics

Mass Spectrometry and Proteomics - Lecture 5 - Matthias Trost Newcastle University

UCD Conway Institute of Biomolecular & Biomedical Research Graduate Education 2009/2010

Data pre-processing in liquid chromatography mass spectrometry-based proteomics

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS

Tandem mass spectra were extracted from the Xcalibur data system format. (.RAW) and charge state assignment was performed using in house software

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Methods for proteome analysis of obesity (Adipose tissue)

SILAC and TMT. IDeA National Resource for Proteomics Workshop for Graduate Students and Post-docs Renny Lan 5/18/2017

Key questions of proteomics. Bioinformatics 2. Proteomics. Foundation of proteomics. What proteins are there? Protein digestion

Analysis of Labeled and Non-Labeled Proteomic Data Using Progenesis QI for Proteomics

The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

MS-based proteomics to investigate proteins and their modifications

Advances in quantitative proteomics using stable isotope tags

6 x 5 Ways to Ensure Your LC-MS/MS is Healthy

Comprehensive support for quantitation

Relative quantification using TMT11plex on a modified Q Exactive HF mass spectrometer

PosterREPRINT COMPARISON OF PEAK PARKING VERSUS AUTOMATED FRACTION ANALYSIS OF A COMPLEX PROTEIN MIXTURE. Introduction

Aplicació de la proteòmica a la cerca de Biomarcadors proteics Barcelona, 08 de Juny 2010

Computational Methods for Mass Spectrometry Proteomics

Optimization and Use of Peptide Mass Measurement Accuracy in Shotgun Proteomics* S

Towards the Prediction of Protein Abundance from Tandem Mass Spectrometry Data

Increasing the Multiplexing of Protein Quantitation from 6- to 10-Plex with Reporter Ion Isotopologues

DIA-Umpire: comprehensive computational framework for data independent acquisition proteomics

Tutorial 1: Setting up your Skyline document

High-Field Orbitrap Creating new possibilities

Identification of proteins by enzyme digestion, mass

Proteomics. Areas of Interest

Yifei Bao. Beatrix. Manor Askenazi

Chemical Labeling Strategy for Generation of Internal Standards for Targeted Quantitative Proteomics

A Quadrupole-Orbitrap Hybrid Mass Spectrometer Offers Highest Benchtop Performance for In-Depth Analysis of Complex Proteomes

Introduction to Proteomics & Bottom-up Proteomics

Accurate, High-Throughput Protein Identification Using the Q TRAP LC/MS/MS System and Pro ID Software

De novo Protein Sequencing by Combining Top-Down and Bottom-Up Tandem Mass Spectra. Xiaowen Liu

Department of Chemistry

Workshop: SILAC and Alternative Labeling Strategies in Quantitative Proteomics

Overview - MS Proteomics in One Slide. MS masses of peptides. MS/MS fragments of a peptide. Results! Match to sequence database

Proteomics. Yeast two hybrid. Proteomics - PAGE techniques. Data obtained. What is it?

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Protein analysis using mass spectrometry

PRG2006 Research Study

Relative Quantitation of TMT-Labeled Proteomes Focus on Sensitivity and Precision

Quantitation of TMT-Labeled Peptides Using Higher-Energy Collisional Dissociation on the Velos Pro Ion Trap Mass Spectrometer

Quantitative Proteomics

Proteome-wide label-free quantification with MaxQuant. Jürgen Cox Max Planck Institute of Biochemistry July 2011

Mass spectrometry-based proteomics has become

Proteomics: the first decade and beyond. (2003) Patterson and Aebersold Nat Genet 33 Suppl: from

Workflow concept. Data goes through the workflow. A Node contains an operation An edge represents data flow The results are brought together in tables

Self-assembling covalent organic frameworks functionalized. magnetic graphene hydrophilic biocomposite as an ultrasensitive

Isobaric Labeling-Based Relative Quantification in Shotgun Proteomics

HR/AM Targeted Peptide Quantitation on a Q Exactive MS: A Unique Combination of High Selectivity, Sensitivity and Throughput

Proteomics and Mass Spectrometry

Chem 250 Unit 1 Proteomics by Mass Spectrometry

Quantitative analysis of the proteome

Biological Mass Spectrometry

Mass spectrometry has been used a lot in biology since the late 1950 s. However it really came into play in the late 1980 s once methods were

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

ADVANCEMENT IN PROTEIN INFERENCE FROM SHOTGUN PROTEOMICS USING PEPTIDE DETECTABILITY

Statistical analysis of isobaric-labeled mass spectrometry data

Targeted protein quantification

Figure S1. Interaction of PcTS with αsyn. (a) 1 H- 15 N HSQC NMR spectra of 100 µm αsyn in the absence (0:1, black) and increasing equivalent

Bioinformatics 2. Yeast two hybrid. Proteomics. Proteomics

Rapid Distinction of Leucine and Isoleucine in Monoclonal Antibodies Using Nanoflow. LCMS n. Discovery Attribute Sciences

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

Tiffany Samaroo MB&B 452a December 8, Take Home Final. Topic 1

Transferred Subgroup False Discovery Rate for Rare Post-translational Modifications Detected by Mass Spectrometry* S

Chapter 2 What are the Common Mass Spectrometry-Based Analyses Used in Biology?

Effective Strategies for Improving Peptide Identification with Tandem Mass Spectrometry

MS Based Proteomics: Recent Case Studies Using Advanced Instrumentation

Atomic masses. Atomic masses of elements. Atomic masses of isotopes. Nominal and exact atomic masses. Example: CO, N 2 ja C 2 H 4

A Software Suite for the Generation and Comparison of Peptide Arrays from Sets. of Data Collected by Liquid Chromatography-Mass Spectrometry

A new algorithm for the evaluation of shotgun peptide sequencing in proteomics: support vector machine classification of peptide MS/MS spectra

Protein Identification Using Tandem Mass Spectrometry. Nathan Edwards Informatics Research Applied Biosystems

Optimization and Use of Peptide Mass Measurement Accuracy in Shotgun Proteomics

Research Article High Mass Accuracy Phosphopeptide Identification Using Tandem Mass Spectra

See for options on how to legitimately share published articles.

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Analysis of Peptide MS/MS Spectra from Large-Scale Proteomics Experiments Using Spectrum Libraries

Peptide Targeted Quantification By High Resolution Mass Spectrometry A Paradigm Shift? Zhiqi Hao Thermo Fisher Scientific San Jose, CA

SRM assay generation and data analysis in Skyline

Protocol. Product Use & Liability. Contact us: InfoLine: Order per fax: www:

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Quantitative analysis of the proteome. Proteomics Data Standards

Effective desalting and concentration of in-gel digest samples with Vivapure C18 Micro spin columns prior to MALDI-TOF analysis.

Qualitative Proteomics (how to obtain high-confidence high-throughput protein identification!)

Types of biological networks. I. Intra-cellurar networks

Applications of Mass Spectrometry for Biotherapeutic Characterization

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Transcription:

994 DOI 10.1002/pmic.200700426 Proteomics 2008, 8, 994 999 TECHNICAL BRIEF A label-free quantification method by MS/MS TIC compared to SILAC and spectral counting in a proteomics screen John M. Asara 1, 2, Heather R. Christofk 3, Lisa M. Freimark 1 and Lewis C. Cantley 1, 3 1 Division of Signal Transduction, Beth Israel Deaconess Medical Center, Boston, MA, USA 2 Department of Pathology, Harvard Medical School, Boston, MA, USA 3 Department of Systems Biology, Harvard Medical School, Boston, MA, USA In order to assess the biological function of proteins and their modifications for understanding signaling mechanisms within cells as well as specific biomarkers to disease, it is important that quantitative information be obtained under different experimental conditions. Stable isotope labeling is a powerful method for accurately determining changes in the levels of proteins and PTMs; however, isotope labeling experiments suffer from limited dynamic range resulting in signal change ratios of less than,20:1 using most commercial mass spectrometers. Label-free approaches to relative quantification in proteomics such as spectral counting have gained popularity since no additional chemistries are needed. Here, we show a label-free method for relative quantification based on the TIC from peptide MS/MS spectra collected from data-dependent runs can be used effectively as a quantitative measure and expands the dynamic range over isotope labeling experiments allowing for abundance differences up to,60:1 in a screen for proteins that bind to phosphotyrosine residues. Received: May 1, 2007 Revised: November 12, 2007 Accepted: November 18, 2007 Keywords: Differential expression / Quantitative analysis / Shotgun proteomics / Signal transduction profiling Methods for acquiring quantitative proteomics data are continually developing with very accurate stable isotope labeling (SIL) and label-free approaches. SIL provides chemically equivalent but isotopically different internal standards for each peptide/protein for direct comparison of mass spectral signal intensities that represent relative abundance. Correspondence: Dr. John M. Asara, Division of Signal Transduction, Beth Israel Deaconess Medical Center, Boston, MA 02115, USA E-mail: jasara@bidmc.harvard.edu Fax: +1-617-667-0957 Abbreviations: DDA, data dependent acquisition; PKM2, pyruvate kinase M2; ptyr, phosphotyrosine; SH2, src homology 2 domain; SIL, stable isotope labeling; SILAC, stable isotope labeling of amino acids in cell culture Common SIL strategies include protein level labeling strategies such as stable isotope labeling of amino acids in cell culture (SILAC) [1], a global method whereby all translated proteins have isotope labels metabolically incorporated at selected amino acid residues, and isotope-coded affinity tags (ICAT) [2], a technique that labels cysteine residues at the protein level. Peptide level labeling strategies include multiplexed isobaric tags for relative and absolute quantification (itraq) [3], global internal standard technology (GIST) [4], a global post-digestion labeling method that labels primary amine groups (peptide N-terminus and lysine residues) and an extension of GIST called in-gel stable isotope labeling (ISIL) [5, 6], a method that labels primary amine groups of proteins (protein N-terminus and lysine residues) directly from gel separated samples. Each isotope labeling strategy has its advantages and disadvantages depending upon the experimental questions but most suffer from an experimental

Proteomics 2008, 8, 994 999 Cell Biology 995 dynamic range limitation of,20:1. Protein level differences greater than this limit usually suffer from very large errors in ratio determination [7]. Label-free approaches to quantitative proteomics have gained prominence in recent years since no additional chemistry or sample preparation steps are required. These include biostatistical profiling [8, 9] in clinical proteomics whereby peptide ions that show intensity changes over many samples are recorded and represent potential protein biomarkers, methods for comparing the ratios of integrated peak areas/intensities of phosphorylated to nonphosphorylated peptide ions between two samples [10, 11], a strategy to assess the stoichiometry of phosphorylation sites [12], and the popular method of quantifying protein levels from different samples based on the number of MS/MS spectra that identify the protein of interest (spectral counting) [13 17]. We demonstrate a method to survey relative protein quantity between samples that is an extension to the spectral counting technique whereby the average of the TIC for all of the MS/MS spectra that identify a protein is used as a quantitative measure. Each spectral count gets a unique abundance value rather than equivalent values of 1 as with spectral counting. This spectral TIC method is effective and expands the dynamic range of quantitative ratios allowing for larger protein abundance differences than the,20:1 practical limit obtained using SIL since some biological systems demonstrate very large protein expression differences. For example, the proto-oncogene products c-jun and c-fos show expression level increases of 38 and 72-fold, respectively, under oxidative stress conditions [18]. Additionally, several other proteins in biological systems such as glucokinase in metabolism demonstrate very large fold changes in protein expression levels [19, 20]. Spectral TIC method: protein pools from at least two different experimental conditions were digested with trypsin and the peptide mixtures were analyzed by microcapillary LC-MS/MS using an LTQ 2-D linear IT (ThermoScientific, San Jose, CA) operated at a flow rate of 300 nl/min in positive ion data dependent acquisition (DDA) mode with a repeating cycle of one survey MS scan followed by eight MS/ MS scans with a 2 min exclusion window collected over a 50 min gradient (4 38% B: ACN, A: 0.1% formic acid/99.9% water). The TIC data from each MS/MS spectrum were obtained from the raw datafile and relative quantitative ratios were calculated by taking the average TIC from all of the MS/ MS spectra identifying each protein including all redundancy, charge states, and missed cleavages, and then dividing the experimental sample (numerator) by the control sample (denominator). Proteomics Browser Software (PBS) (Thermo Scientific) readily extracts TIC values for each identified peptide and calculates the average and sum for each protein. By using the average TIC, rather than the sum of TIC, we can eliminate the sampling bias caused by different protein molecular weights since larger proteins generate more tryptic peptides than smaller proteins. Proteins matching the forward database were accepted if at least two unique peptides were identified from a SEQUEST search against the reversed NCBInr protein database with a PBS consensus score greater than 1.00. To show that spectral TIC compares well to spectral counting and is capable of increased dynamic range, two different concentrations of a BSA digestion (50 fmol and 1 pmol) were injected onto the LC-MS/MS system and SEQUEST identified 54 and 206 tryptic peptide spectra, respectively. These numbers represent the spectral counts. The spectral counting ratio was 3.8:1 though a 20:1 concentration difference was experimentally created. If one averages the TIC values for all of the BSA tryptic peptide spectra from each experiment, 7.9E5 (1 pmol digest) and 3.8E4 (50 fmol digest), the ratio is 20.8:1, a value very close to the actual 20:1 abundance ratio while the spectral counting method did not produce an accurate ratio. To support the result, the area of the reconstructed ion chromatograms for several peptides from each experiment from the MS scan was calculated and the average ratio was 17.9:1 for the 1 pmol:50 fmol (20.0:1) digestion mixtures supporting the accuracy of the method. One of the disadvantages of spectral counting is that the length of the protein influences the number of theoretical peptides that can be produced from tryptic digestions. The difference in quantitative accuracy between spectral counting and spectral TIC for the BSA example was due to the fact that at 50 fmol of digest, the theoretical limit of the number of possible detected peptides was approached with 62.1% amino acid coverage compared to 78.9% amino acid coverage for the 1 pmol digest given the high sensitivity of the LTQ IT. In these cases, relative quantity can only be assessed by using peak intensity values in either the MS or MS/MS scans. We also tested the variability of the spectral TIC ratios by injecting 300 fmol of a BSA digest 14 consecutive times and calculating 7 ratios that should theoretically be 1:1. The ratios ranged from 0.8 to 1.4 with the average ratio of 1.1, a SD of 0.226, and a CV of 20.7%. While the accuracy may be less than SIL experiments, the ease of use, lack of additional chemistries, and increased dynamic range are great benefits. Screen for phosphotyrosine (ptyr) binding proteins: to demonstrate the effectiveness of the spectral TIC approach for quantifying a wide range of protein abundance differences in real biological systems, a screen for proteins that bind to ptyr residues was performed. Hela cell lysates were run over two types of columns. One column contained a fixed ptyr residue at the center of a partially degenerate biotinylated 13-mer peptide library bound to streptavidin beads. The control column was identical except for a fixed nonphosphorylated Tyr residue in the center position of the peptide library in order to assess protein binding differences based solely on the phosphorylated Tyr residue. Proteins were eluted from each column with 20 mm sodium phenyl phosphate, digested with trypsin and then separated into six fractions by strong cation exchange (SCX) chromatography using a Paradigm 2D-LC (Michrom Bioresources, Auburn,

996 J. M. Asara et al. Proteomics 2008, 8, 994 999 CA) using 20 450 mm ammonium formate in 25% ACN over 30 min. Peptide mixtures were run by LC-MS/MS using the LTQ IT in positive ion DDA mode. Relative quantitative ratios were calculated using two methods. First, ratios of proteins from each column were calculated by using spectral counting. The degree of protein binding to the ptyr column was calculated by a ratio of the number of spectral counts from the ptyr column experiment divided by the number of spectral counts from the Tyr column experiment. Secondly, spectral TIC was used to calculate the relative quantitative ratios. Figure 1 shows the experimental workflow. From the label-free ptyr screen, we show nine proteins including eight known src homology 2 domain (SH2) domain-containing proteins [21] and pyruvate kinase M2 (PKM2), a glycolytic protein that is critical for proliferating cancer cells [22]. To demonstrate an example of a specific ptyr binding protein acquired by the spectral TIC method, the 85kDa regulatory beta subunit of phosphoinositide 3- kinase (p85) resulted in a spectral counting ratio of 15.0:1 (15 spectra from ptyr column and 1 spectrum from the Tyr column) while the spectral TIC ratio was 16:1 from the average TIC values 1.60E from the ptyr column and 1.0E 4 from the Tyr column. For p85, the spectral counting and spectral TIC ratios were nearly identical. However, PKM2 showed a spectral TIC ratio of 59.3:1, a ratio nearly twice the spectral counting ratio of 31.5:1. As quantitative controls for the experiment, ratios were also calculated for many proteins that did not change in protein abundance between the two experimental conditions (no preference for ptyr) such as filamin, plectin, myosin 9, HSP-70, HSP-90 and many others. The spectral TIC ratios for these proteins were all approximately 1:1, suggesting nonspecific binding. The difference in the ratios is likely due to a dynamic range limit of the spectral counting method similar to the situation for the BSA digest example above. Comparison to SILAC: spectral counting and spectral TIC were then compared with SILAC using the same experimental conditions whereby two pools of HeLa cells were grown with either light ( 12 C 6 ) or heavy ( 13 C 6 ) lysine and Figure 1. The experimental workflow for collecting label-free spectral TIC relative quantitative data in a screen for ptyr binding proteins. In general, protein pools from different sources are digested separately, peptides separated by SCX, and peptide fractions analyzed by data dependent LC-MS/MS. The TIC values from all tandem mass spectra identifying a protein from each experimental condition are averaged and the spectral TIC ratio is calculated for relative quantification.

Proteomics 2008, 8, 994 999 Cell Biology 997 arginine amino acids. Heavy cell lysate was passed over ptyr column while light lysate was passed over the Tyr column. Bound proteins were eluted with phosphate buffer, combined and separated by SDS-PAGE. The entire lane was excised into ten gel pieces, digested separately with trypsin, and then run by microcapillary LC-MS/MS in DDA positive ion mode for both identification and quantification using a high resolution QSTAR Pulsar i hybrid qtof mass spectrometer (Applied Biosystems/MDS Sciex, Framingham, MA) with one MS survey scan followed by three MS/MS scans. For SILAC, proteins were identified from the MS/MS scans and average peak pair ratios were calculated from the MS scan using the Paragon algorithm in ProteinPilot software (Applied Biosystems). Many peptide sequences per protein (at least six) contributed to the average SILAC ratios. The nonspecific binding proteins showed ratios of,1:1, very similar to spectral TIC ratios. A ptyr binding protein was determined by a heavy (ptyr column): light (Tyr column) ratio of at least 3:1, the same values used for spectral TIC. Using p85 as an example, an average heavy/light ratio of 11.1:1 was determined and the peptide ion pairs appeared as heavy singlet peaks since only the heavy form bound to the ptyr column while no or little p85 bound to the Tyr column. To demonstrate an extreme dynamic range limitation of SIL, an average SILAC ratio of,15:1 was calculated for PKM2 compared to the ratios of 59.3:1 for spectral TIC and 31.5:1 for spectral counting. Figure 2 shows a ratio plot for nine ptyr binding proteins as well as several control proteins for the three different methods of relative quantification (spectral counting, spectral TIC, and SILAC). The spectral TIC ratio is valid based on several methods including SDS-PAGE and Western blots [22]; however the SILAC ratio appears erroneously low due to the dynamic range limitation for SIL experiments with TOF based mass spectrometers. Spectral counting shows improved dynamic range over SIL, however, to a lesser extant than spectral TIC. Table 1 lists the parameters and calculated values used for the three quantification strategies. The differences between the ratios of the ptyr binding proteins obtained from the screen can be due to several factors including cellular protein abundance and binding efficiency to the ptyr peptide library, and neither of these can be differentiated in these experiments. The binding of SH2 domains to ptyr is influenced by the amino acid sequence N- terminal and C-terminal of the ptyr residue [21]. Also, MS/ MS TIC values from shotgun DDA experiments can be subjective based on several factors during the analysis, including previous peptide ions that were attacked for MS/MS in data dependent cycles, the chromatographic elution point when a peptide ion is selected for MS/MS and differences in ionization efficiencies. However, we have determined that if sufficient peptide MS/MS spectra per protein (5) are identified, the average TIC value from DDA MS/MS spectra is a valid indicator of a protein s relative abundance. Since the average TIC values are calculated over many peptides per protein, the method can also be used to assess relative stoichiometry of protein complexes within a single sample. We have tested Figure 2. The plot of the ratios of ptyr binding proteins to Tyr binding proteins using two label-free methods (spectral counting and spectral TIC) and one SILAC for relative quantification. Data for eight SH2 domain containing proteins and PKM2 are shown with spectral TIC quantitative ratios that exceed the maximum observed ratios for both SILAC and spectral counting. The data shows that the spectral TIC approach for label-free relative quantification demonstrates increased dynamic range that allows for a much wider range of quantification than isotope-labeling or spectral counting.

998 J. M. Asara et al. Proteomics 2008, 8, 994 999 Table 1. Experimental values and relative quantitative ratios for ptyr binding proteins from a screen and several examples of nonspecific background proteins ptyr binding proteins (LC-MS/MS instrument) Spectral TIC (ptyr) LTQ Spectral TIC (Tyr) LTQ Spectral TIC Ratio Spectral count (ptyr) LTQ Spectral count (Tyr) LTQ Spectral counting Ratio SILAC peptides number QSTAR Avg. SILAC ratio (ptyr:tyr) PKM2 8.30E 1 05 1.40E 1 04 59.3 63 2 31.5 44 15.0 Grb2 2.40E 1 05 1.00E 1 04 24.0 5 1 5.0 6 11.1 STAT 5B 1.60E 1 05 1.00E 1 04 16.0 6 1 6.0 11 9.7 PLC-g-1 1.10E 1 05 1.00E 1 04 11.0 13 1 13.0 13 11.3 SHC transforming 2.00E 1 05 1.00E 1 04 20.0 8 1 8.0 8 8.7 protein 1 PI3K p85 b 1.60E 1 05 1.00E 1 04 16.0 15 1 15.0 23 11.1 STAT 3 2.60E 1 05 1.00E 1 04 26.0 13 1 13.0 13 9.1 SHP-1 1.80E 1 05 1.00E 1 04 18.0 19 1 19.0 22 11.2 SHP-2 2.40E 1 05 1.00E 1 04 24.0 9 1 9.0 7 11.7 (1.00E 1 04 represents background signal) Background proteins (most not listed) Filamin A 1.70E 1 05 2.90E 1 05 0.6 28 14 2.0 39 1.3 Plectin 1.60E 1 05 2.80E 1 05 0.6 17 38 0.4 12 1.0 HSP-70 3.30E 1 05 1.90E 1 05 1.7 19 10 1.9 28 1.1 HSP-90 b 2.30E 1 05 2.20E 1 05 1.0 13 5 2.6 21 0.5 Myosin 9 8.90E 1 04 1.40E 1 05 0.6 23 15 1.5 26 1.0 relative concentrations of tryptic digests of BSA and Annexin V mixed at 3:1 (600 fmol:200 fmol), 1:1 (300 fmol:300 fmol), and 1:3 (200 fmol:600 fmol) ratios and were able to determine the relative stoichiometric ratios using spectral TIC with a 19.7% CV for five LC-MS/MS injections of each mixture. The isotope-free spectral TIC method demonstrates a simple method for assessing relative quantities of proteins in different samples without the need for additional chemistries or complex calculations. The data can be extracted from typical LC-MS/MS experiments. It is not limited in the number of samples that can be quantified per experiment as with many SIL approaches and the expanded dynamic range provides insight into the relative binding efficiency and cellular protein abundance from regulatory processes that show very large fold changes and biomarker discovery where proteins become highly elevated in the diseased state. While isotope labeling methods have great utility due to their accuracy of quantification, they have limited dynamic range so that very large differences in peptide/protein abundance cannot be assessed. We thank Sean Seymour for providing a beta version of ProteinPilot software. We also thank the National Institutes of Health (awards 1P01CA120964 and 5P30CA006516-43), Takeda Chemical Industries, and The Paul F. Glenn Foundation for funding this work. The authors have declared no conflict of interest. References [1] Li, J., Steen, H., Gygi, S. P., Protein profiling with cleavable isotope-coded affinity tag (cicat) reagents: The yeast salinity stress response. Mol. Cell. Proteomics 2003, 2, 1198 1204. [2] Mann, M., Functional and quantitative proteomics using SILAC. Nat. Rev. Mol. Cell Biol. 2006, 7, 952 958. [3] Ross, P. L., Huang, Y. L. N., Marchese, J. N., Pappin, D. J. C., Multiplexed protein quantification in Saccharomyces cerevisiae using amine-reactive isobaric tagging reagents. Mol. Cell. Proteomics 2004, 3, 1154 1169. [4] Chakraborty, A., Regnier, F. E., Global internal standard technology for comparative proteomics. J Chromatogr. A 2002, 949, 173 184. [5] Asara, J. M., Zhang, X., Zheng, B., Christofk, H. H. et al., In-gel stable-isotope labeling (ISIL): A strategy for mass spectrometry-based relative quantification. J. Proteome. Res. 2006, 1, 155 63. [6] Asara, J. M., Zhang, X., Zheng, B., Maroney, L. A. et al., In-gel stable isotope labeling for relative quantification using mass spectrometry. Nat. Protoc. 2006, 1, 46 51. [7] Turck, C. W., Falick, A. M., Kowalak, J. A., Lane, W. S. et al., The Association of Biomolecular Resource Facilities Proteomics Research Group 2006 Study: Relative protein quantitation. Mol. Cell Proteomics 2007, 6, 1291 1298. [8] Kearney, P., Thibault, P., Bioinformatics meets proteomics bridging the gap between mass spectrometry data analysis and cell biology. J. Bioinform. Comput. Biol. 2003, 1, 183 200. [9] Wang, W., Zhou, H., Lin, H., Roy, S. et al., Quantification of proteins and metabolites by mass spectrometry without iso-

Proteomics 2008, 8, 994 999 Cell Biology 999 topic labeling or spiked standards. Anal. Chem. 2003, 75, 4818 4826. [10] Tsay, Y. G., Wang, Y. H., Chiu, C. M., Shen, B. J., Lee, S. C., A strategy for identification and quantification of phosphopeptides by liquid chromatography/tandem mass spectrometry. Anal. Biochem. 2000, 287, 55 64. [11] Asara, J. M., Lane, W. S., Ratio analyzed quantification (RAQ) of phosphorylation sites from different protein states by LC/MS/MS. Presented at The 50th ASMS Conference on Mass Spectrometry and Allied Topics on June 13, 2002. [12] Steen, H., Jebanathirajah, J. A., Springer, M., Kirschner, M. W., Stable isotope-free relative and absolute quantitation of protein phosphorylation stoichiometry by MS. Proc. Natl. Acad. Sci. USA 2005, 102, 3948 3953. [13] Washburn, M. P., Wolters, D., Yates, J. R., III, Large-scale analysis of the yeast proteome by multidimensional protein identification technology. Nat. Biotechnol. 2001, 19, 242 247. [14] Gao, J., Opiteck, G. J., Friedrichs, M. S., Dongre, A. R., Hefta, S. A., Changes in the protein expression of yeast as a function of carbon source. J. Proteome Res. 2003, 2, 643 649. [15] Pang, J. X., Ginanni, N., Dongre, A. R., Hefta, S. A., Opiteck, G. J., J. Proteome. Res. 2002, 1, 161 169. [16] Liu, H., Sadygov, R. G., Yates, J. R., III, A model for random sampling and estimation of relative protein abundance in shotgun proteomics. Anal. Chem. 2004, 76, 4193 4201. [17] Zhang, B., VerBerkmoes, N. C., Langston, M. A., Uberbacher, E. et al., Detecting differential and correlated protein expression in label-free shotgun proteomics. J. Proteome Res. 2006, 5, 2909 2918. [18] Li, D. W. C., Spector, A., Hydrogen peroxide-induced expression of the proto-oncogenes, c-jun, c-fos and c-myc in rabbit lens epithelial cells. Mol. Cell. Biochem. 1997,173,59 69. [19] Heredia, V. V., Carlson, T. J., Garcia, E., Sun, S., Biochemical basis of glucokinase activation and the regulation by glucokinase regulatory protein in naturally occurring mutations. J. Biol. Chem. 2006, 281, 40201 40207. [20] Webb, G. C., Akbar, M. S., Zhao, C., Steiner, D. F., Expression profiling of pancreatic B cells: Glucose regulation of secretory and metabolic pathway genes. Proc. Natl. Acad. Sci. USA 2000, 97, 5773 5778. [21] Zhou, S., Shoelson, S. E., Chaudhuri, M., Gish, G. et al., SH2 domains recognize specific phosphopeptide sequences. Cell 1993, 72, 767 778. [22] Christofk, H. R., Van der Heiden, M. G., Wu, N., Asara, J. M., Cantley, L. C., Pyruvate kinase M2 is a novel phosphotyrosine binding protein. Nature, In press.