In Situ Observation of Damage Evolution in Polycarbonate under Ion Irradiation with Positrons

Similar documents
Application of positrons in materials research

Positron Annihilation Spectroscopy - A non-destructive method for material testing -

Interaction of ion beams with matter

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

POSITRON AND POSITRONIUM INTERACTIONS WITH CONDENSED MATTER. Paul Coleman University of Bath

EEE4106Z Radiation Interactions & Detection

Positronium Formation at Low Temperatures in Polymers and Other Molecular Solids

on basis of the Geant4 simulations

Study of semiconductors with positrons. Outlook:

Positron Annihilation Spectroscopy

Introduction into Positron Annihilation

Recent Activities on Neutron Calibration Fields at FRS of JAERI

Measurement of 40 MeV Deuteron Induced Reaction on Fe and Ta for Neutron Emission Spectrum and Activation Cross Section

Outlook: Application of Positron Annihilation for defects investigations in thin films. Introduction to Positron Annihilation Methods

CHAPTER-II Experimental Techniques and Data Analysis (Positron annihilation spectroscopy)

High-temperature In-situ Measurements of Thermal Vacancies in a TiAl Intermetallic Compound using a Desktop Positron Beam

PRINCIPLES OF POSITRON ANNIHILATION

Basics and Means of Positron Annihilation

DETECTORS. I. Charged Particle Detectors

III. Energy Deposition in the Detector and Spectrum Formation

Chapter 4 Scintillation Detectors

positron source EPOS - general concept - timing system - digital lifetime measurement

New Concept of EPOS Progress of the Mono-energetic Positron Beam (MePS) Gamma-induced Positron Spectroscopy (GiPS)

Emphasis on what happens to emitted particle (if no nuclear reaction and MEDIUM (i.e., atomic effects)

Ultrafast X-Ray-Matter Interaction and Damage of Inorganic Solids October 10, 2008

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

The intense positron source EPOS at Research Center Rossendorf

EPOS an intense positron beam project at the Research Center Rossendorf

1.E Neutron Energy (MeV)

The intense Positron Source EPOS at ELBE Radiation Source of Research Center Rossendorf

Studies on 3D Fusion Reactions in TiDx under Ion Beam Implantation

Positron and Positronium Annihilation in Polymers Studied by Age-Momentum Correlation Spectroscopy

The intense, pulsed positron source EPOS at the Research Centre Dresden-Rossendorf

Fast Monte-Carlo Simulation of Ion Implantation. Binary Collision Approximation Implementation within ATHENA

Positron Annihilation in Material Research

Slow-Positron-Beam Techniques

Scintillation Detector

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

Lab1. Resolution and Throughput of Ion Beam Lithography.

1. Introduction Zhe Chen 1,2,, Zhi Wang 1,2,QiumingFu 1,2, Zhibin Ma 1,2, Pengfei Fang 3, and Chunqing He 3. (Received March 10, 2014)

Positron Probe Microanalyzer (PPMA) facilities at AIST

Comparison of the Photo-peak Efficiencies between the Experimental Data of 137 Cs Radioactive Source with Monte Carlo (MC) Simulation Data

M. Werner, E. Altstadt, M. Jungmann, G. Brauer, K. Noack, A. Rogov, R. Krause-Rehberg. Thermal Analysis of EPOS components

Gamma ray coincidence and angular correlation

Chapter 2 Chemistry of High-Energy Charged Particles: Radiations and Polymers

Introduction. Neutron Effects NSEU. Neutron Testing Basics User Requirements Conclusions

Outline. Radiation Interactions. Spurs, Blobs and Short Tracks. Introduction. Radiation Interactions 1

Práctica de laboratorio número 6: Non-Rutherford scattering near the MeV 12 C(p,p) 12 C resonance

Research Center Dresden Rossendorf

Measurement of activation of helium gas by 238 U beam irradiation at about 11 A MeV

SIMULATION OF LASER INDUCED NUCLEAR REACTIONS

Modeling of charge collection efficiency degradation in semiconductor devices induced by MeV ion beam irradiation

Positron-Electron Annihilation

Radiation Quantities and Units

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation

Monte Carlo study of medium-energy electron penetration in aluminium and silver

Method of active correlations in the experiment 249 Cf+ 48 Ca n

Chapter V: Interactions of neutrons with matter

Identification of Getter Defects in high-energy self-implanted Silicon at Rp/2

in Si by means of Positron Annihilation

High-Precision Evaluation of Ultra-Shallow Impurity Profiles by Secondary Ion Mass Spectrometry

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

Multiscale modelling of D trapping in W

A new protocol to evaluate the charge collection efficiency degradation in semiconductor devices induced by MeV ions

Material Science using Positron Annihilation

13th International Workshop on Slow Positron Beam Techniques and Applications

Flux and neutron spectrum measurements in fast neutron irradiation experiments

Characterisation of mesopores - ortho-positronium lifetime measurement as a porosimetry technique

Spatial Distribution of D-D/D- 3 He Advanced Fuels Fusion Reactions in an Inertial Electrostatic Confinement Device

Implantation Energy Dependence on Deuterium Retention Behaviors for the Carbon Implanted Tungsten

Positron theoretical prediction

(a) Mono-absorber. (b) 4-segmented absorbers. (c) 64-segmented absorbers

Radioactivity. Lecture 6 Detectors and Instrumentation

Development of Gamma-ray Monitor using CdZnTe Semiconductor Detector

Quantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography

Positron Beam Lifetime Spectroscopy at

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

Activities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)

Precision neutron flux measurement with a neutron beam monitor

Measurement and Analysis of the Positron Annihilation Lifetime Spectra for Mesoporous Silica

1.4 The Tools of the Trade!

Interaction of charged particles and photons with matter

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

I. 16. Coloration of Polyethylene Terephthalate (PET) Film by 3MeV Proton Beams

Bhas Bapat MOL-PH Seminar October Ion Matter Interactions and Applications

Damage to Molecular Solids Irradiated by X-ray Laser Beam

Simulation of the cathode surface damages in a HOPFED during ion bombardment

1.5. The Tools of the Trade!

Nuclear Physics and Astrophysics

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Positron Annihilation techniques for material defect studies

The accelerators at LNS - INFN and diagnostics aspects of the radioactive beams

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Compton Camera. Compton Camera

ICTP-IAEA Joint Workshop on Nuclear Data for Science and Technology: Medical Applications. 30 September - 4 October, 2013

Transcription:

Proc. 2nd Japan-China Joint Workshop on Positron Science JJAP Conf. Proc. 2 (2014) 011103 2014 The Japan Society of Applied Physics In Situ Observation of Damage Evolution in Polycarbonate under Ion Irradiation with Positrons Hidetsugu Tsuchida 1,2,, Hironori Tsutsumi 2, Masafumi Akiyoshi 2, and Takeo Iwai 3 1 Quantum Science and Engineering Center, Kyoto University, Uji, Kyoto 611 0011, Japan 2 Department of Nuclear Engineering, Kyoto University, Kyoto 615 8530, Japan 3 Faculty of Medicine, Yamagata University, Yamagata 990 9585, Japan E-mail: tsuchida@nucleng.kyoto-u.ac.jp (Received Jul. 1, 2014) We report β + γ coincidence positron annihilation lifetime spectroscopy of in situ observation of ion damage in polycarbonate under irradiation by MeV-energy H + ions. Ion damage was investigated from changes in the relative intensity of the long-lived ortho-positronium pick-off annihilation lifetime component measured under irradiation and non-irradiation conditions. It was found that at fluences of less than 10 15 ions cm 2 the relative intensity of this component during irradiation was significantly reduced compared to that after irradiation. This reduction disappears at fluences higher than 10 15 ions cm 2. Results suggest that at fluences up to 10 15 ions cm 2, transient damage structures are formed under irradiation. 1. Introduction Ion-irradiation modifications of materials are one of the most fundamental methods of ion beam processing. This method is applied for manufacturing porous membranes of polymeric materials as track-etching technology. Polymer modification due to ion irradiation results from dynamical atomic collision processes that occurred along the ion trajectory in a nanometer size region (latent ion tracks). Understanding the damage processes in the tracks is important for controlling the modification structures. For fast ion irradiation of polymers, the damage is induced mainly via ionization or electronic excitation of target atoms. This leads to polymer dissociation, such as radical formation, bond scission and cross-linking of polymer chains. Ion induced damage of polymers has been studied so far by means of various analytical techniques [1 3]. Positron annihilation spectroscopy is a powerful method for investigating radiation damage involving microstructural changes of materials at the atomic level. In our previous work, we have applied positron annihilation spectroscopy for observations of ion damage evolution in metallic materials [4 7]. Vacancy defects produced under irradiation were studied via in situ measurement of positron annihilation Doppler broadening spectra. Results showed that vacancy concentration is enhanced under irradiation, originating from transient vacancy production, compared to that observed after irradiation. Thus, in situ positron annihilation spectroscopy is applicable for detection of radiation defects that are produced during irradiation. For ion damage of polymers, polymer dissociation results from a variety of time-dependent radiation-chemical reactions. In situ study of damage evolution under irradiation is therefore an important subject for understanding mechanisms of polymer modifications in ion-beam processing. In this work, we present a new method for in situ observation of ion damage evolution in materials by combining a β + γ coincidence positron annihilation lifetime spectroscopy apparatus with a highenergy ion accelerator. The use of positron lifetime spectroscopy makes it possible to perform identification of different types of radiation damage. The purpose of this study is to understand initial damage states that are formed in the low fluence range. To investigate irradiation effects on poly- 1 011103-1

011103-2 mers induced via electronic excitation processes, specimens of polycarbonate were irradiated with 2.0 MeV H + ions. Positron annihilation lifetime spectra were measured alternately under irradiation and non-irradiation conditions. From the analysis of the ortho-positronium pick-off annihilation component in the lifetime spectra, we investigated microstructure changes that occurred under irradiation and their depencence on ion fluence. 2. Experimental methods The experiment was performed using the 1.7 MV tandem accelerator at the Quantum Science and Engineering Center, Kyoto University. Figure 1 shows the experimental setup for in situ observation of ion damage under irradiation with positrons. The apparatus consists of a positron annihilation spectroscopy device and a beam-energy moderator device. In the positron annihilation spectroscopy device, we used the β + γ coincidence positron annihilation lifetime spectroscopy (PALS) method to achieve a specimen-positron source separation arrangement [8]. This makes it possible to simultaneously perform ion irradiation of the specimen during positron lifetime measurements. A radioactive isotope 68 Ge was used as the positron source. Positrons emitted from the 68 Ge source penetrate through a transmission type avalanche photodiode detector (APD) with a thickness of 150 μm, and then enter the target specimen. The specimen was positioned between two scintillation detectors. A pair of annihilation γ-ray photons, generated in the specimen and emitted in opposite directions, were detected by two different detectors (BaF 2 and NaI(Tl)). One of the annihilation γ-rays was detected by the BaF 2 detector, and the other was detected by the NaI(Tl) detector. The lifetime of a single positron annihilation event was measured by detecting the time difference between the start signal provided from the APD and the stop signal from the BaF 2 detector. The NaI(Tl) detector provides a coincidence gate-signal of a multi-channel analyzer (MCA). This coincidence setup enables us to eliminate components of the positron annihilation that occurred outside of the specimen, and also serves to reduce the lifetime spectra background. BaF scintillator 2 Specimens Energy moderator (metallic foils of various thicknesses) γ-rays Ion beams 68 Ge APD e + γ-rays Goniostage θ θ NaI(Tl) scintillator Fig. 1. Schematic diagram of the experimental setup for in situ observation of ion damage under irradiation by β + γ coincidence positron annihilation lifetime spectroscopy. Polycarbonate with a thickness of 125 μm, obtained from the Goodfellow Company, UK, was used as a target specimen. The specimen was irradiated by H + ions with a primary energy of 2.0 MeV. The ion beams were collimated to a spot size of 15 mm 15 mm, and were directed parallel to the surface normal of the target specimen. Positron lifetime spectra were measured alternately under irradiation and non-irradiation conditions. The average fluence received by specimen after a single 2

011103-3 10 5 10 4 Counts 10 3 10 2 10 1 10 0 0 1000 Energy [kev] 2000 Fig. 2. Energy spectra of projectile beams after passing through the energy moderator. The primary energy of the H + ion beams from the accelerator (before entering into the moderator) was 2.0 MeV. irradiation run was on the order of 10 14 ions cm 2. The time resolution of the β + γ coincidence PALS measurement system was less than 300 ps. The coincidence rate was 10 cps, depending on the thickness of the measuring specimen. The total number of counts in each spectrum was more than 1.0 10 5. The data-acquisition time was 4 h 5 h for each lifetime spectrum. The lifetime spectra obtained were analyzed using a PALS-fit code [9]. In the ion irradiation experiments, we used an energy moderator device to produce a uniform damage distribution throughout a specimen thickness. It is necessary to produce a uniform damage distribution because the positrons from the 68 Ge source have a broad energy distribution. The energy moderator device consists of rectangular titanium foils of various thicknesses arranged on a rotating drum driven by a pulse motor at a frequency of about 1 Hz, as shown in Fig. 1. A mono-energy beam obtained from the accelerator was converted to an energy-broadened beam by passing through the moderator, and then was incident on a target specimen. Figure 2 shows the energy spectrum of projectile beams after passing through the moderator, as measured by a silicon semiconductor detector. In this measurement, the primary beam was 2.0 MeV H + ions, and the moderator consisted of titanium foils having eleven different thicknesses of zero (blank), 2.5, 5.5, 8.0, 10.5, 13.0, 15.0, 18.5, 22.0, 25.0, and 28.0 μm. One can see eleven peaks in the energy spectrum, each peak corresponding to the energy-loss of the projectile beam passing through the various foils. We calculated damage distributions for the energy-broadened beam obtained from moderator by the following method. First, we obtained peak energies and intensities (integrated peak intensities) from the energy spectrum shown in Fig. 2. Second, for a projectile with each peak-energy we calculated a damage distribution by using the TRIM code [10]. Finally, by summing up each damage distribution weighted by the corresponding peak intensity, we obtained a damage distribution produced by the energy-broadened beam. Figure 3 shows the obtained damage distributions resulting from nuclear or electronic energy-loss process for the energy-broadening beam. From the results, one can see that more uniform damage distributions are achieved by utilizing the moderator compared to the un-moderated beam. Positrons from the 68 Ge source have a maximum kinetic energy of approximately 1.9 MeV, and hence the penetration depth in matter is in the order of few mm. This means that it is not applicable for analysis of damage depth profiles in the range less than a few hundred μm. In this study, the thickness of specimens used was 125 μm. To overcome this limitation, we utilize the glancing angle 3

011103-4 incidence method, as shown in Fig. 1. In this method positrons enter the specimen at small angles to the surface. Even if the positron energy is high, the positron implantation depth remains shallow. In the present experiments, the incident angle θ was set to 5 degrees. Electronic energy loss [ev/å] 10 5 2 1 10-3 Displacement μm] per atoms [/ 10-4 10-5 10-6 0 20 40 60 Target depth [μm] Fig. 3. Calculated damage distributions for the energy-broadened beam: the upper and the lower figures show the damage distributions originating from the electronic energy loss process and the nuclear energy loss process, respectively. Solid curves denote the damage distributions for primary beams of 2.0 MeV H + ions. 3. Results and discussion For each measured positron lifetime spectra a two-component analysis was carried out using the PALSfit program [9]. From the analysis, we obtained the long-lived lifetime component which is attributed to the pick-off annihilation of ortho-positronium (o-ps) in the polymer free volume. The lifetime and relative intensity of the o-ps pick-off component is sensitive to induced radiation damage. Figure 4 shows the measured o-ps annihilation lifetime and relative intensity as a function of fluence for irradiation of polycarbonate with MeV-energy H + ions. Closed and open symbols denote the data observed under irradiation (during irradiation) and non-irradiation (after irradiation), respectively. In this figure, values of fluence for data observed during irradiation were plotted as the central value of the fluence measured before and after irradiation. One can see different behavior in fluence dependence between the lifetime and the intensity. The lifetime value was approximately 2 ns, and remained unchanged irrespective of fluence. In contrast, the intensity of o-ps component decreases with increasing fluence. This intensity decrease is due to increase in new positron annihilation sites produced by ion damage. In addition, the intensity was found to reduce significantly under irradiation at low fluences less than 10 15 ions cm 2, compared to that observed after irradiation. This reduction disappears at fluences higher than 10 15 ions cm 2. These results suggest that the fluence has an effect on damage structures. We discuss type of damage structures formed under the present experimental conditions. It is known that two major types of damage structures are produced in ion irradiation of polymers: chain scission and cross-linking [11]. Mechanisms of these damage structures depend on the following parameters: irradiation conditions (ion species, ion energy, fluence) and energy deposition processes (nuclear and electronic stopping powers, or linear energy transfer (LET)). The most important of these parameters are the LET value and fluence. The LET affects the track structure. Tracks are 4

011103-5 Lifetime (o-ps) [ns] 2.1 2 1.9 before/after irradiation during irradiation Intensity (o-ps) [%] 26 25 24 23 22 21 0 1 2 Fluence [ 10 15 ions/cm 2 ] Fig. 4. Variation of the lifetime and the intensity of o-ps component as a function of the fluence. Solid and dashed lines denote guide of the eyes. composed of a random succession of spurs which are small localized regions of energy deposition by the primary particle and by secondary electrons. A typical value of the energy deposited in one spur is less than 100 ev. The track structure varies depending on the density of spurs. For low LET, spurs are produced sparsely in a track. Such isolated spur affects only simple molecular chains, leading to chain scission of polymers. For high LET, spurs overlap each other and reactive free radicals are formed in high concentration over many neighboring molecular chains. This causes cross-linking to occur between those scission chains. The description above is applicable to the fluence effect on damage mechanisms i.e. the fluence effect is related to track density. At low fluence, damage with a simple structure such as chain scission is dominantly formed because of the low damage density (non-overlapping of tracks). With increasing fluence, tracks overlap and interactions between damage formed in the tracks occur, leading to a complex damage structure such as cross-linking of polymer chains. Thus, damage structures change from chain scission to cross-linking with increasing fluence. In Fig. 4, the o-ps intensity decreases with increasing fluence, its value becomes constant at fluences higher than 10 15 ions cm 2. This fluence dependence may be attributed to the difference in damage structures. Similar results have been reported in the study of ion damage of polymeric materials different from the specimens used in this study [12]. For poly(methyl methacrylate), PMMA, ir- 5

011103-6 radiated with 1.5 MeV H + ions (low LET radiations), it was found that chain scission is formed at fluences of less than 10 13 ions cm 2 and cross-linking occurs at higher fluence above 10 15 ions cm 2. In this study, H + beams with energy distributions as shown in Fig. 2 were used. These belong to low-let radiations because the electronic stopping power (or the LET value) for the projectiles in polycarbonate is less than 100 ev/nm from the SRIM calculation [10]. Therefore, it is likely that the damage structure produced is a simple chain scission. As shown in Fig. 4, the o-ps intensity observed under irradiation is lower than that after irradiation at fluences of less than 10 15 ions cm 2.This implies that some of the ion damage produced under irradiation recovers after irradiation. A possible damage recovery process includes molecular breakage due to the formation of reactive intermediates such as free radicals, ions and excited states. These intermediates are formed under irradiation, but are unstable and hence recombine after irradiation [13]. It is therefore phenomenologically concluded that transient damage structures consisting of molecular chain scission induced by reactive intermediates are formed under irradiation at fluences up to 10 15 ions cm 2. Further study is needed to identify in detail the types of defects formed under irradiation. We plan to obtain information about the lifetime values of damage component in the lifetime spectra, by further improvement of the time resolution. 4. Conclusion We studied the ion damage evolution in polycarbonate by in situ observation of positron annihilation lifetime spectra. The β + γ coincidence positron annihilation lifetime spectroscopy method was applied for investigating microstructural changes of materials under ion irradiation. We investigated effects of electronic collision process on polymers for polycarbonate irradiated by MeV-energy H + ions. The relative intensity was found to reduce significantly under irradiation at low fluence less than 10 15 ions cm 2, compared to that observed under non-irradiation. This result implies that damage concentration during irradiation is high compared with that surviving after irradiation. It was also found that the reduction disappears at fluences higher than 10 15 ions cm 2. This suggests that transient damage structures consisting of molecular chain scission induced by reactive intermediates are formed at fluences up to 10 15 ions cm 2 under the present experimental conditions. Acknowledgment We thank Professor Ichiro Katayama of Institute of Particle and Nuclear Studies (KEK) for valuable discussion. We also thank Mr. Keizo Norizawa and Mr. Masahiro Naitoh of the accelerator facility of Quantum Science and Engineering Center, Kyoto University for their technical assistance during the experiments. This work was partly supported by a contribution from the Kansai Atomic Energy Council. References [1] T. Venkatesan: Nucl. Instrum. Methods Phys. Res. Sect. B-Beam Interact. Mater. Atoms 7 8 (1985) 461. [2] L.S.Wielunski,R.A.Clissold,E.Yap,D.G.McCulloch, D. R. McKenzie, and M. V. Swain: Nucl. Instrum. Methods Phys. Res. Sect. B-Beam Interact. Mater. Atoms 127 128 (1997) 698. [3] J. Zhang, J. Kang, P. Hu, and Q. Meng: Appl. Surf. Sci. 253 (2007) 5436. [4] H. Tsuchida, T. Iwai, M. Awano, M. Kishida, I. Katayama, S. C. Jeong, H. Ogawa, N. Sakamoto, M. Komatsu, and A. Itoh: J. Phys.-Condens. Matter 19 (2007) 136205. [5] H. Tsuchida, T. Iwai, S. Kasai, H. Tanaka, N. Oshima, R. Suzuki, T. Yoshiie, and A. Itoh: J. Phys.-Conf. Ser. 262 (2011) 012060. [6] T. Iwai and H. Tsuchida: Nucl. Instrum. Methods Phys. Res. Sect. B-Beam Interact. Mater. Atoms 285 (2012) 18. [7] H. Tsuchida, T. Iwai, M. Awano, N. Oshima, R. Suzuki, K. Yasuda, C. Batchuluun, and A. Itoh: J. Nucl. Mater. 442 (2013) S856. 6

011103-7 [8] P. Chalermkarnnon, M. Yuga, S. Nakata, S. Kishimoto, H. Araki, and Y. Shirai: RADIOISOTOPES 50 (2001) 576. [9] PALS-fit computer program, http://palsfit.dk/. [10] J. Zieglar, J. F. Biersack, and U. Littmark: The Transport of Ions in Matter (TRIM) Monte-Carlo Calculation Including in Computer Program SRIM Version (2008), http://www.srim.org. [11] E. H. Lee, G. R. Rao, and L. K. Mansur: Radiat. Phys. Chem. 55 (1999) 293. [12] T. M. Hall, A. Wagner, and L. F. Thompson: J. Vac. Sci. Technol. 16 (1979) 1889. [13] E. H. Lee: Nucl. Instrum. Methods Phys. Res. Sect. B-Beam Interact. Mater. Atoms 151 (1999) 29. 7