Multi-Instrument Manager Tool for Data Acquisition and Merging of Optical and Electrical Mobility Size Distributions

Similar documents
Introduction and Initial Field Data of a Novel, Portable Nanoparticle Sizing Instrument

Particle Size Distribution Measurements with the Novel 1 nm-smps

NanoScan SMPS A Novel, Portable Nanoparticle Sizing and Counting Instrument

NANOSCAN SMPS SPECTROMETER COMPARED TO THE TSI SMPS SPECTROMETER

Product data sheet Palas U-SMPS 1050 / 1100 / 1200

The new 11-R (one part of the Mini WRAS) and GRIMM MINI-WRAS Andreas Jaksch. Symposium Stockholm Mai

Product data sheet Palas Nanoparticle measurement system DEMC 2000

Rapid Measurements of Aerosol Size Distributions Using a Fast Integrated Mobility Spectrometer (FIMS)

Particle counting efficiencies of new TSI condensation particle counters

ELECTROSTATIC CLASSIFIER MODEL 3082

International publications on measuring nanoparticles with the portable testo DiSCmini particle counter.

MEASURING NANOPARTICLE EXPOSURE

New Instruments from GRIMM

Engineered Nanomaterials and Occupational Health

A new versatile condensation particle counter for research and environmental monitoring

Comprehensive Measurement of Atmospheric Aerosols with a Wide Range Aerosol Spectrometer

Mobility-Based Particle Size Classification and Detection down to 2nm Theory to Practice

Supplementary Material

Nanoparticle Exposure in the Workplace

OPTICAL PARTICLE SIZER MASS CALIBRATION METHOD

Brian Sargent, Assistant Director, Designee 3/21/18. See Thread for Approval

Model 2300XP PSL & Process-Particle Wafer Deposition System

Characterisation of Nanoparticle Structure by High Resolution Electron Microscopy

Traceability research activities in the field of airborne particle number/ mass concentration measurement Liu Junjie, Zhang Wenge, Song Xiaoping

SIZE-SELECTED AEROSOL FILTER ANALYSIS USING ELECTROSTATIC CLASSIFICATION AND LIBS

Measuring sub-50nm particle retention of UPW filters

Differential Mobility Particle Sizer (Aerosol measurements)

Evaluation of the NanoAerosol Generator by Kanomax FMT Inc. in Aerosolization of Size Standard Nanoparticle and Protein

SOP SMPS BaltimorePM supersite Version /29/01 Page 1 of 13 SMPS

(manufactured) nano aerosols

Supplementary information

NANOPARTICLE MEASUREMENT SYSTEMS

Measure and classify nanoparticles at the touch of a button. With the portable particle counter testo DiSCmini.

Peter Kearns, PhD OECD, ENV/EHS BIPM, April 2015

Measuring ultrafine particles emitted by gasoline direct injection engines: the PEMS4Nano Project

Defects Panel Discussion

An autonomous underwater telescope for measuring the scattering of light in the deep sea

Aerosol size distribution estimation and associated uncertainty for measurement with a Scanning Mobility Particle Sizer (SMPS)

Jianfei Peng et al. Correspondence to: Jianfei Peng Min Hu and Renyi Zhang

COPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:

Overview of the Particle Size Magnifier (PSM)

Overview of LNE s activities led in aerosol metrology

Base metal thermocouples drift rate dependence from thermoelement diameter

DMA Size-Selection and Electrostatic Deposition of Particle Size Standards Down to 10nm

DiSCmini. Handheld diffusion size classifier for nanoparticle measurement.

High strain rate fracture behaviour of fused silica

Case Study Nanoparticle Containment

Particle number concentration standards at NMIJ, including a new calibration service with an inkjet aerosol generator.

UPDATED INVERSION MATRICES FOR ENGINE EXHAUST PARTICLE SIZER (EEPS ) SPECTROMETER MODEL 3090

Model 3450 Vibrating Orifice Aerosol Generator

An industrial radiography exposure device based on measurement of transmitted gamma-ray intensity

Intercomparison of Mobility Particle Size Spectrometers

Penetration of 4.5 nm to 10 μm aerosol particles through fibrous filters

TSI KNOWS NANOPARTICLE MEASUREMENT

COUNTS SURFACE VOLUME MASS COLLECTION GENERATION

Causes of Concentration Differences Between a Scanning Mobility Particle Sizer and a Condensation Particle Counter

Influence of temperature on the production and size distribution of fine particles released from beech wood samples

Comparison Among DMS 500, EEPS SMPS, MSS, EC/OC, CPMA, Using Laboratory Soot Particles

for XPS surface analysis

Quantification of ligand packing density on gold nanoparticles using ICP-OES

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Information on the test material EDS-TM002 and the BAM software package EDX Spectrometer Test for determination of the spectrometer performance

Calibration checks of particle counter using primary and other techniques at the laboratory level

Fundamentals of Particle Counting

Research on State-of-Charge (SOC) estimation using current integration based on temperature compensation

Intercomparison of Mobility Particle Size Spectrometers

Particle Collection and Concentration for Cyclone Concentrators

Measurement strategies for nanomaterials applicability to the environment

Urban background aerosols: Negative correlations of particle modes and fragmentation mechanism

Fog Monitor 100 (FM 100) Extinction Module. Operator Manual

Charge transport mechanisms in macro-scale CNT films

Nanoparticle Analyzer

P R O D U C T. he Model 3800 Aerosol Time-of-Flight Mass Spectrometer. Determines size and chemical composition of single particles

The Elzone II Particle Count and Size Analyzer

QUT-Thermodenuder (TD)

The Scanning DMA Transfer Function

NON-FUNCTIONALISED AND FUNCTIONALISED SILICA NANOSPHERES 1. Case metadata

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Effect of Electrolyte Concentration during Solution Plasma on Copper Nanoparticle Size

Optimization of Parameters for Manufacture Nanopowder Bioceramics at Machine Pulverisette 6 by Taguchi and ANOVA Method

Characterization of manufactured TiO 2 nanoparticles

Analysis of high altitude clouds in the martian atmosphere based on Mars Climate Sounder observations

Fate, Transport, and Toxicity of Nanoparticles in the Environment

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Nuclear Science and Engineering Institute, University of Missouri, USA and Sidney Kimmel Institute for the Nuclear Renaissance

LIBSlab ANALYZERS ANALYZERS

PYCKO SCIENTIFIC LIMITED

Portable Instrument for Online Investigations of Optical Properties of Airborne Particles

Intercomparison of Mobility Particle Size Spectrometers

Lab VI Light Emitting Diodes ECE 476

ISO INTERNATIONAL STANDARD

Generation and Evaluation of Monodisperse Sodium Chloride and Oleic Acid Nanoparticles

Zeta Potential Analysis using Z-NTA

Standardization needs and suggestions to EURAMET for consideration in their upcoming EMPIR calls

Simulations of an etched spiral axial attenuation scheme for an on-axis reflecting telescope

High Performance, Low Operating Voltage n-type Organic Field Effect Transistor Based on Inorganic-Organic Bilayer Dielectric System

Recent progress and future prospects for traceable submicron aerosol measurements

There are a number of instruments that can be used to measure LDSA; for example, TSI has two

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS

Transcription:

Journal of Physics: Conference Series PAPER OPEN ACCESS Multi-Instrument Manager Tool for Data Acquisition and Merging of Optical and Electrical Mobility Size Distributions To cite this article: Torsten Tritscher et al 2015 J. Phys.: Conf. Ser. 617 012013 Related content - Multi-instrument characterization of optical turbulence at the Ali observatory L-Y Liu, Y-Q Yao, J Vernin et al. - A MICROCOMPUTER BASED SYSTEM FOR DATA ACQUISITION AND INSTRUMENT CONTROL N. M. White and L. H. Wasserman - The software system for the Control and Data Acquisition for the Cherenkov Telescope Array P Wegner, M FüBling, I Oya et al. View the article online for updates and enhancements. This content was downloaded from IP address 148.251.232.83 on 22/04/2018 at 19:10

Multi-Instrument Manager Tool for Data Acquisition and Merging of Optical and Electrical Mobility Size Distributions Torsten Tritscher 1, Amine Koched 2, Hee-Siew Han 3, Eric Filimundi 2, Tim Johnson 3, Sherrie Elzey 3, Aaron Avenido 3, Carsten Kykal 1 and Oliver F. Bischof 1 1 TSI GmbH, Particle Instruments, Neuköllner Str. 4, 52068 Aachen, Germany 2 TSI France Incorporated, Technopôle de Château-Gombert, 13382 Marseille, France 3 TSI Incorporated, 500 Cardigan Road, Shoreview, MN 55126, USA E-mail: torsten.tritscher@tsi.com Abstract. Electrical mobility classification (EC) followed by Condensation Particle Counter (CPC) detection is the technique combined in Scanning Mobility Particle Sizers (SMPS) to retrieve nanoparticle size distributions in the range from 2.5 nm to 1 m. The detectable size range of SMPS systems can be extended by the addition of an Optical Particle Sizer (OPS) that covers larger sizes from 300 nm to 10 m. This optical sizing method reports an optical equivalent diameter, which is often different from the electrical mobility diameter measured by the standard SMPS technique. Multi-Instrument Manager (MIM TM ) software developed by TSI incorporates algorithms that facilitate merging SMPS data sets with data based on optical equivalent diameter to compile single, wide-range size distributions. Here we present MIM 2.0, the next-generation of the data merging tool that offers many advanced features for data merging and post-processing. MIM 2.0 allows direct data acquisition with OPS and NanoScan SMPS instruments to retrieve real-time particle size distributions from 10 nm to 10 m, which we show in a case study at a fireplace. The merged data can be adjusted using one of the merging options, which automatically determines an overall aerosol effective refractive index. As a result an indirect and average characterization of aerosol optical and shape properties is possible. The merging tool allows several pre-settings, data averaging and adjustments, as well as the export of data sets and fitted graphs. MIM 2.0 also features several post-processing options for SMPS data and differences can be visualized in a multi-peak sample over a narrow size range. Keywords: SMPS, OPS, NanoScan SMPS, wide-range particle measurement, data post-processing 1. Introduction The comprehensive measurement of number concentrations and size distributions of aerosols in the sub-micrometer range has received much consideration during the past years. Assessing possible exposure to nanomaterial used in or added to products but also the investigation of airborne nanoparticles in general requires suitable and sensitive instruments. Toxicology studies reported a high Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by IOP Publishing Ltd 1

rate of pulmonary deposition of nanoparticles, and also show their ability to travel from lung to systemic sites (Oberdörster et al., 2005). Additionally a high inflammation potential of nanoparticles was reported by other studies. Nanoparticles have a relative large surface area per mass which can be seen as interaction interface. Therefore it has been concluded that particles in the nanometer range are more biologically active (Gurr et al., 2005). Measuring exposure to nanoparticles has been conducted in academic research using high-end instrumentation in the laboratory. With the need to move these measurements out of the laboratory into the field to study indoor air quality and occupational health and safety, more compact and easy to use instrumentation is required to characterize the aerosol. Commonly the technique of choice is electrical mobility classification followed by Condensation Particle Counter (CPC) detection. Both are typically combined in a Scanning Mobility Particle Sizer (SMPS) to retrieve nanoparticle size distributions in the range from 2.5 nm to 1 m. During the last NanoSafe Conference we introduced the NanoScan SMPS (TSI model 3910, Tritscher et al., 2012), which is a novel, portable nanoparticle sizing and counting instrument that is capable of covering the range from 10 to 420 nm. Its straightforward portability is a key to help in source identification measurements. The detection size range of SMPS systems can be extended by the addition of an Optical Particle Sizer (OPS, TSI model 3330) that covers larger particle sizes from 300 nm to 10 m and is also a portable and compact device. Its optical sizing method reports an optical equivalent diameter, which is often different from the electrical mobility diameter measured by the standard SMPS technique. Discrepancies between different measurement principles as well as the challenges in combining size spectral data were the motivation to develop a small but powerful data merging tool. Multi-Instrument Manager (MIM TM ) software was introduced by TSI to integrate algorithms that facilitate the merging of SMPS data based on electrical mobility diameter with data dependent on an optical equivalent diameter into one single, wide-range data set. Here we present the functionality of MIM 2.0, the nextgeneration of the data merging tool and give some data merging, data acquisition and SMPS postprocessing examples. 2. Method and Instrumentation The Multi-Instrument Manager (MIM TM ) software is a MATLAB-based tool that allows reviewing, averaging, merging and post-processing data from TSI SMPS spectrometers equipped with the previous 3080 and the new 3082 Electrostatic Classifier generations, NanoScan SMPS (TSI model 3910) and/or OPS (TSI model 3330) instruments. MIM software was introduced by TSI after the original development of dedicated algorithms (Han et al., 2011) that facilitate merging SMPS data based on electrical mobility diameter with data based on optical equivalent diameter to compile a single, wide-range data set. MIM 2.0 features increased channel resolution of up to 128 size channels per decade of recorded SMPS raw data files, comparison of SMPS correction steps and combination of multiple units. One of the key features when merging OPS with electrical mobility distributions is that the software takes aerosol optical properties into account by automatically determining an overall aerosol effective refractive index that was used to adjust the merged data. Thus an indirect and average characterization of aerosol optical and shape properties is possible. In Figure 1 we show an example for measurements from SMPS and OPS with the resulting composite fit. The merging procedure is heavily dependent on the particle type, concentration and distribution. 2

Figure 1: Size distribution of ambient air aerosol from SMPS and OPS measurement displayed in the MIM 2.0 view. The top panel shows the individual size distributions as well as their average and the lower graph shows the merged curve as a result in red. Data merging is done is by combining two size distribution measurements that have been uploaded, which can also be the averages of several size distributions. The Merge and Fit panel (data control area, see Figure 1) allows parameterization of the merge algorithm. The merge option selection panel includes No Correction, Minimum Gap and Calibration Data. The software s Minimum Gap option will seek to minimize the gap (global minimum) between the SMPS and the OPS distributions by varying the real part of the refractive index and shape correction factor of the OPS data. Typical values displayed for the real part of refractive index are between 1.3 to 1.8, and for the shape correction factor 0.8 to 1.05. The optimal refractive index found by the algorithm will provide the best fit to the data but is not necessarily equivalent to the bulk refractive index of the aerosol of interest. However, in many cases it can help to provide further insight into the characteristics of the optical aerosol properties. For the Calibration Data option, the algorithm seeks to minimize the difference between the calibration data and reference monodisperse sizes by varying the shape factor as well as the real and imaginary part of the refractive index. This option is only possible if the user created a calibration data set earlier on. As the OPS is calibrated with polystyrene latex (PSL) reference particles, the optically determined particle diameters from the OPS may differ from physical particle diameters due to material properties such as refractive index, morphology and shape. By using an Electrostatic Classifier to supply monodisperse aerosols to the OPS, the OPS can be calibrated to measure mobility diameter. Particles used for such a calibration should be the same or as a minimum comparable to the particles sampled as size distributions that should be merged. Additional settings like fit mode selection (e.g. auto/1/2/3) help to find the best fitting curve and the weighting option allows prioritizing data either based on SMPS/NanoScan SMPS or OPS in the overlapping region. All merged size distributions and data sets as well as fitted graphs can be 3

exported. MIM 2.0 permits several pre-settings, data averaging and adjustments. More details on the different options and settings can be found in the MIM user guide. 3 Results and Discussion 3.1. Multi-Modal Laboratory Aerosol Data merging of uni-modal size distributions as shown in Figure 1 is typically not very challenging for any fitting procedure. Therefore a laboratory aerosol was generated from two different aerosol sources and subsequently measured. We used Arizona Road Dust in a Small Scale Powder Disperser (SSPD, TSI model 3433) and a sucrose solution in a constant output atomizer (TSI model 3076) with diffusion dryer. NanoScan SMPS and OPS were used to detect and determine the size distribution of the mixed lab aerosol. The two instruments sampled the laboratory aerosol from a mixing chamber (blue bean pot as shown in Figure 2). The aerosol generation was largely stable over a time span of several minutes, which is displayed in the several thin curves in the top panel of Figure 3. The average size distributions from NanoScan SMPS and OPS were used for the data merging but the same is possible also for individual scans. Figure 3 shows the data merging result using the Minimum Gap option in the lower panel and suggested a three modal composite fit. The software tool can easily deal with multi-modal distribution as these results demonstrate. Figure 2: Setup with NanoScan SMPS and OPS for laboratory-generated bi-modal aerosols. A constant output atomizer and a Small Scale Powder Disperser (SSPD) were used for the primary generation and the aerosol was subsequently mixed inside the blue mixing manifold. 4

Figure 3: Multimodal size distributions of a laboratory aerosol displayed in the MIM 2.0 view. Minimum gap merging and three modal fitting were pre-selected. The red curve in the lower panel shows the resulting fit. 3.2. Case Study Fireplace The capabilities of MIM were further tested for a real-world aerosol that requires a wide measurement size range. In a brief case study we collected data with NanoScan SMPS and OPS instruments from a wood-burning fireplace. The fireplace was located in the living room of a domestic building. The ambient air in the room where the fireplace is located was monitored for two hours, with the instruments set to 1 min sample time per run. Compressed wood was used as fuel, which was again added after one hour of fireplace operation. The details of the actual measurement setup are considered to be of secondary importance here as the main purpose of this work is not the evaluation of the burning behavior but collecting exemplary data for use with the new MIM 2.0 software. Figure 4 summarizes the results during the two hour measurement period complemented with photos of the corresponding burning phases. The top panels show 1 min size distribution scans and their average value and the red curves in the lower panels present the merged size distribution curves, respectively. The size distribution shown ranges from 10 nm to 10 μm. A nucleation mode develops during the measurement and after an hour forms a stable mode around 20-30 nm, while the accumulation mode at around 100 nm decreases relatively and shifts slowly to size larger than 100 nm. For a more comprehensive study that describes the complete development of the bimodal size distribution of the fireplace emission, smaller average intervals should be chosen as some information gets lost, especially in the beginning when size distributions vary rapidly. However, here we focus exclusively on the MIM processing option and using average values before merging is one possible approach if not every single size distribution should be merged individually. 5

Figure 4: Development of measured aerosol size distribution during a fireplace burning cycle. The upper panels show the individual measured size distributions for NanoScan SMPS and OPS and their average (bold curve). The merging results of the bimodal size distributions are shown in the middle panel and on the bottom photographs that illustrate the corresponding burning phases. 6

3.3. Post-processing of SMPS Data Other than the actual merging of measurement data, MIM 2.0 allows also post-processing electrical mobility size distribution data recorded with the high-resolution component SMPS. Data from the recently-introduced SMPS, TSI model 3938 (Tröstl et al., 2014) that uses a newly-developed Electrostatic Classifier (TSI model 3082) as well as most data from SMPS based on the 3080 model Electrostatic Classifier can be loaded for re-processing. There are several configuration options within the SMPS Settings window for the data inversion that is applied. The main panels for modifications are Classifier Platform, Time Delay, Correction and Channel Resolution. Three drop-down menus exist within the Classifier Platform panel to modify the data corrections for impactor size, DMA high voltage polarity and neutralizer type that were used when collecting the data. The Time Delay panel allows for adjustment of the amount of time it takes for an aerosol to travel from the outlet of the classifier DMA to the CPC detector. Figure 5 gives an example of how the Correction panel in the SMPS Settings window of MIM can be used to apply physical property adjustments. In this example a multi-peak particle size distribution in the low diameter range sub-20 nm is shown without corrections (blue curve). The same size distribution with multiple charge and diffusion loss corrections applied can be directly compared to the uncorrected curve in the same graph. Accounting for diffusion losses results in a higher concentration, while the multi-charge correction only has a negligible effect in this example due to the small, completely single charged particle diameters (Figure 5). Figure 5: Direct comparison of SMPS size distribution with and without corrections for diffusion losses and multiple charging in MIM. A second SMPS post-processing example is shown in Figure 6 for the Channel Resolution panel. The MIM software enables increasing the displayed SMPS size resolution from 64 channels per decade to 128 channels per decade by reanalyzing the raw measurement data, which are typically not accessible. Results from a multi-peak scan in the lower nanometer range displayed with 64 channels per decade and 128 channels per decade are shown in Figure 6. This higher resolution can be useful in cases like the selected example but there are many size distributions which do not necessarily benefit from an increased channel resolution. We also want to point out that it is only possible to reprocess the data for higher size resolution if the SMPS spectrometer settings during the collection of the raw data were set accordingly. 7

Figure 6: Multi-peak scan in the lower nanometer size range of the SMPS with different size resolution. The standard resolution is 64 channels per decade (blue). The increased resolution with 128 channels per decade (green) can be reprocessed from raw data. 4. Conclusions In this paper we describe the new Multi-Instrument Manager (MIM 2.0) software which is an easy to use tool to merge and post-process data from commonly used TSI SMPS, NanoScan SMPS and OPS instruments. Merging of size distributions from electrical mobility and optical diameter based instruments can be done in three different ways and by selecting several fitting options with the objective of retrieving one single size distribution over a wide particle size range. Case studies for laboratory and fireplace aerosols conducted with NanoScan SMPS and OPS instruments demonstrated that curve fit distributions with up to three modes of lognormal distribution from nano- and micrometer sizing instruments can be merged well up to three modes of lognormal distribution. Also online data acquisition over a wide range as well as data processing from two instruments of the same type are now possible. In addition we have shown that MIM is capable of doubling the size resolution of existing SMPS data to 128 channels per decade. Recorded SMPS data sets can be reprocessed to take into account different post-processing settings and the applied corrections can be displayed for direct comparison. This feature provides SMPS users better control and more options to evaluate and process size distribution data sets. While MIM software does not have the purpose to replace instrument measurement software such as the Aerosol Instrument Manager (AIM, TSI Inc.), it is an additional tool that helps to develop a better understanding of aerosol size distribution data over a wide size range. 5. References Gurr, J.R., Wang, A.S.S., Chenb, C-H. and K.Y. Jan, Ultrafine titanium dioxide particles in the absence of photoactivation can induce oxidative damage to human bronchial epithelial cells. Toxicology, 213: 66-73, 2005. Han, H. S., Sreenath, A., Birkeland, N. T. and G. J. Chancellor, 7th Asian Aerosol Conference, pp. Paper Number ID153, Xi'an, China, 2011. Oberdörster G, Oberdörster E and J. Oberdörster, Nanotoxicology: an emerging discipline evolving from studies of ultrafine particles. Environ Health Perspect, 11: 823-839, 2005. 8

Tritscher, T., Beeston, M., Zerrath, A.F., Elzey, S., Krinke, T.J., Filimundi, E. and O.F. Bischof, NanoScan SMPS A novel, portable nanoparticle sizing and counting instrument. Journal of Physics (IOP): Conference Series 429, 012061, 2013. Tröstl, J., Tritscher, T., Bischof, O.F., Horn, H.-G., Krinke, T.J., Baltensperger, U., Gysel, M., Fast and Accurate Measurement in the Sub-20 nm Range using a Scanning Mobility Particle Sizer. Journal of Aerosol Science, submitted December 2014. 6. Supplementary comment SMPS/NanoScan SMPS/OPS customers can download MIM 2.0 software free of charge from the following website: www.tsi.com/mim. 9