Solid Phase Microextraction

Similar documents
SUPELCO. SPME-Adsorption versus Absorption: Which Fiber is Best for Your Application? Robert E. Shirey and Raymond F. Mindrup

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

Solid Phase Micro Extraction (SPME) of Opiates from Urine: Coupling SPME and DESI-MS/MS Detection

Headspace Technology for GC and GC/MS: Features, benefits & applications

PAL SPME Arrow The Better SPME

PAL SPME Arrow The Better SPME

Analysis of BTEX in Natural Water with SPME

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

Determination of Volatile Substances Proof of Food Adulteration

Chemical Analysis Problem

The Optimal Analytical Method of NDMA(N-Nitrodimethylamine) by Solid-Phase Microextraction Analysis (SPME)

From Student to Scholar A 30- year Journey of Transformation

Sample Prep for Chromatographic Analysis of Difficult Matrixes

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

GC/MS Application Note

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Application of Solid Phase Micro Extraction in Environmental Analysis

ChromTech options for PAL systems

Analytical Microextraction: Current Status and Future Trends

AUTOMATED HEADSPACE. Headspace Principles. Graham Broadway. Headspace Gas Chromatography Background to the HS Technique

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

AYOUB ET AL.: JOURNAL OF AOAC INTERNATIONAL VOL. 85, NO. 6,

Headspace Solid Phase Microextraction/Gas Chromatography for Determination of Aldehydes

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Air Sampling and Analysis of Volatile Organic Compounds with Solid Phase Microextraction

Determination of Limonene Oxidation Products Using SPME and GC MS

Calibration for On-Site Analysis of Hydrocarbons in Aqueous and Gaseous Samples Using Solid- Phase Microextraction

Gas Chromatography (GC)

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

SOLID PHASE MICROEXTRACTION FOR TRACE ANALYSIS OF BENZENE IN ENVIRONMENTAL MONITORING

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

TechNote 5/2002 KEYWORDS ABSTRACT. SBSE, Twister, Thermal Desorption

Application of Bio-SPME for the Enrichment of Illicit Phenethylamine and Cathinone Compounds from Biological Samples

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Ch24. Gas Chromatography (GC)

The Role of the Carbon Cartridge in the One-Pass System

Determination of volatiles in Food sample preparation strategies and techniques Dr Kathy Ridgway

Solid-phase Microextraction in Analysis of Pollutants in the Field

Analytical Trap Comparison for USEPA Method 8260C

GC Application Note. Determination of C2-C12 aldehydes in water by SPME on-fiber derivatization.

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Vinyl chloride analysis with Solid Phase Microextraction (SPME)/GC/MS applied to analysis in materials and aqueous samples

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Virtually Particle-Free Rt -Silica BOND Columns

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

COMBI. Gaschromatography. GC / GC-MS sample injector grows with your needs

Application. Gas Chromatography February Introduction

The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques

A Study of the Behavior of Maillard Reaction Products Analyzed by Solid-Phase Microextraction-Gas Chromatography-Mass Selective Detection

Experimental Determination of Pyrolysis Products from Carbon/Resin Ablative Materials

Study of Residual Solvents in Various Matrices by Static Headspace

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

Detection of Chemical Warfare Agents by Transportable GC/MS

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

METHOD 8041 PHENOLS BY GAS CHROMATOGRAPHY

Introduction and Principles of Gas Chromatography

Dynamic headspace (DHS) technique: set-up and parameter control for GC/MS analysis of odorant formulations

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to En vi ron men tal Aqueous Samples INTRODUCTION

Author. Abstract. Introduction

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler

Chemistry Instrumental Analysis Lecture 27. Chem 4631

SELECTED ION FLOW TUBE MASS SPECTROMETRY. Interscience Expert Center: VIP Meeting 15 Sept. 2009

Activity in the FID Detection Port: A Big Problem if Underestimated

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Determination of releasable 2,4,6-trichloroanisole in wine by cork stoppers (Resolution OIV-Oeno 296/2009)

Development of a solid-phase microextraction method for the determination of phthalic acid esters in water

Ben Diamond. Sonoma State University

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa

Selection of a Capillary

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

DETERMINATION OF GAMMA-HYDROXYBUTYRATE (GHB) BY HEADSPACE-GC/MS (FID) IN FORENSIC SAMPLES

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

Thin film microextraction

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

Sorptive sample preparation a review

Low-Level Sulfur Compounds in Beer by Purge and Trap with a Pulsed Flame Photometric Detector (PFPD)

Dedicated solvents for Headspace GC

Thermo Scientific TriPlus RSH Autosampler Integrated Sampling System. You are productive solving your chromatography challenges

SUPELCO. Chiral GC Using Cyclodextrin-Based Capillary Columns. Jamie Desorcie Gas Separations R&D. Supelco, Supelco Park, Bellefonte, PA T499136

Chromatography. Gas Chromatography

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

Fused Silica Fibers in the Extraction of Organics from Water Matrix Samples and their Rapid Transfer to Capillary Columns.

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

A Comparison of Volatile Organic Compound Response When Using Nitrogen as a Purge Gas

Solid Phase Microextraction of Cyanogen Chloride and Other Volatile Organic Compounds in Drinking Water with Fast Analysis by GC-TOFMS

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column

Transcription:

Solid Phase Microextraction Basics, Theory and Environmental Analysis Dr. Frank Michel frank.michel@sial.com

SPME History Patented Technology of University of Waterloo, Canada Inventor: Prof. Dr. Janusz Pawliszyn Automation by Varian (AS 8200 & CTC CombiPal). CTC CombiPal makes the SPME compatibel with most GCs 2

SPME: used in thousands of applications Source ISI Search: Solid Phase Micro Extraction and SPME Published Items in Each Year Citations in Each Year Items: 10720 Total Citations: 143140 (reviews not included) H-index: 104 (reviews not included) 3

SPME Holders For Manual Sampling (Fiber Exposed) Plunger For Varian 8100/8200 AutoSampler or SPME/HPLC Interface (Fiber Retracted) Plunger Barrel Z Slot Retaining Screw Barrel Plunger Retaining Screw Slot Hub-Viewing Window Adjustable Needle Guide/Depth Gauge Color-Coded Screw Hub Sealing Septum Fiber-Attachment Needle Retaining Nut Fiber-Attachment Needle Septum-Piercing Needle Coated SPME Fused Silica Fiber 713-0105 Septum-Piercing Needle Needle Ferrule Coated SPME Fused Silica Fiber 4 713-0107

SPME Fiber Assembly Detail (Manual) Color-Coded Screw Hub Tensioning Spring Sealing Septum Ferrule Septum-Piercing Needle Fiber-Attachment Needle Coated SPME Fused Silica Fiber 713-1344 5

Types of SPME Fiber Assemblies Assemblies for holders manual autosampler style (no spring) Gauge size of piercing needle Standard size - 24 GA Larger bore size - 23 GA (for septum free inj. ports) Types of fiber core Fused silica Stableflex Metal NEW! 6

Extraction Procedure for SPME Pierce Sample Septum Expose Fiber/Extract Retract Fiber/Remove to GC Instrument 713-1345 7 98-0369

Desorption Procedure for SPME Pierce GC Inlet Septum Expose Fiber/Desorb Retract Fiber/Remove to Column 713-1345 8 98-0370

Adsorption Mechanism for SPME Equilibrium reached Silica Rod Analyte Adsorbed Liquid Polymer Aqueous Solution Vial Extraction Time 9 98-0371

Amount of Analyte absorbed by the Fiber at Equilibrium for small sample volumes (2-5ml): n s = KV f C 0 V s KV f +V s at infinite volume of samle (V s >> V f ): n s = KV f C 0 K Distribution Costant fiber/sample n s Analyte moles into the Stationary phase V f Stationary Phase Volume V s Sample Volume Concentration of the Analyte in water C 0 10

Adsorption-time Profile for BTEX Compounds Using SPME 8.00e+6 K is compound specific Also dependend of fiber & matrix 6.00e+6 m+p-xylene Kinetics of analytes are different Higher k values require longer equilibrium times 4.00e+6 2.00e+6 ethyl benzene o-xylene toluene benzene 0.00e+0 0 100 200 300 400 500 600 700 secs. Figure courtesy of J. Pawliszyn, et al., University of Waterloo, Ontario, Canada. 11 92-0139

Physical Factors Affecting Sample Recovery Influence on Equilibrium Influence on Kinetics Stiring (Temperature) 12 95-0224A

Stirring in SPME Time dependence Extraction of 1,3-Dichlorobenzene Stirred Fiber coating Sample unstirred time/s Static Layer formed 13

Factors Affecting Sample Recovery Fiber Selection Sample Modifications Extraction Time Desorption Conditions Inlet Design Column Selection 15 95-0224A

Available SPME Fibers, by Film Type Absorption Fibers Polydimethylsiloxane (PDMS) 7, 30, and 100µm Polyacrylate (PA) Polyethyleneglycol (PEG) Adsorption fibers (with particles) Carboxen-polydimethylsiloxane(CAR-PDMS) Polydimethylsiloxane-divinylbenzene (PDMS-DVB) Divinylbenzene/Carboxen- Polydimethylsiloxane (DVB-CAR-PDMS) Unpolar Polar Polar Adsorption Adsorption Adsorption 16 98-0373

Adsorbent vs. Absorbent Fibers Adsorbent (particle) fibers Physically traps or chemically reacts bonds with analytes - porous material - high surface area Absorbent (film) fibers Analytes are extracted by partitioning liquid phase retains by thickness of coating Analytes may compete for sites Analytes do not compete for sites Fibers have limited capacity Fibers can have high capacity 17 00-0003

Area Response depending on Fiber Type 6,27E+05 Bare FS 7µm 30µm 100µm Pacrylate PDMS-DVB CW-DVB DVB-CAR Carboxen 6,80E+05 7,04E+03 4,73E+03 3,81E+03 2,58E+05 0 2,99E+03 p-nitroaniline p-nitrophenol Phenol 1,3,5- Trinitrobenzene 18

SPME Fibers by Adsorption Strength Estimation TPR 7µm PDMS 30µm PDMS 100µm PDMS PDMS-DVB DVB-Carboxen Carboxen 0 150 300 450 Analyte Molecular Weight Range Approximation 19

Comparison of SPME Fibers for the Extraction of Small Hydrocarbons (Analytes at 1ppm in Air, Extracted for 10 Min) Analyte 100µm PDMS PDMS/DVB Carboxen TM /PDMS Ethane 0 0 750 Propane 0 0 20000 Butane 0 340 72100 Pentane 230 2150 108000 Hexane 460 9280 105000 20 97-0328

SPME Fibers for the Extraction of Hydrocarbons n= Carboxen -PDMS Carboxen-DVB-PDMS PDMS-DVB 2 200 80 3 800 260 30 4 2600 1000 200 5 7000 3200 800 6 13000 7000 2200 7 10000 5000 2200 8 53000 29000 14000 9 49000 29000 14000 10 160000 100000 49000 12 230000 150000 90000 14 480000 300000 260000 16 490000 380000 360000 18 44000 110000 130000 20 18000 60000 110000 22 6600 24000 64000 24 3400 12000 46000 21

Odor Agents at 1ppt in Water by SPME-GC/MS Sample: 30mL water containing MIB and geosmin at 1ppt and 25% NaCl in a 40mL vial, at 65 C SPME Fiber: DVB/Carboxen /PDMS Extraction: heated headspace, 30 min, 65 C, with rapid stirring Desorption: 3 min, 250 C, splitter closed Column: Meridian MDN-5, 30m x 0.25mm x 0.25µm film Oven: 60 C (1 min) to 250 C at 15 C/min Det.: mass spectrometer, m/z = 75-180 at 0.6 sec/scan (quantitation ions 95 and 112) MIB Geosmin 6 7 8 9 Min 22 G000169

SPME Technique Extraction conditions Headspace Direct Imersion Desorption temperature Liner Diameter Sample Modifications 25

Headspace vs. Direct Immersion Volatility of Sample Extraction Time concerns Sample Matrix Selectivity of Analytes 26 95-0235

Fruit Punch Flavor by Headspace SPME Elimination of Glycerin Interference Propylene glycol Ethyl caproate Direct Injection HS SPME Glycerin Figure provided by Dr. A. Harmon, McCormick & Co., Inc., Hunt Valley, MD, USA. 6 8 10 12 Min 14 16 18 20 27

Sample Modifications Salt ph Derivatisation of analytes on the fiber Fiber saturated with reagent put into sample extraction Fiber with extracted analytes put into reagent 28

Sample Modifications The Effect of Salt and ph on Extraction of Phenols (50ppb) by SPME (PA) No Salt No Salt Salt Salt Neutral ph = 2 Neutral ph = 2 2-Chlorophenol 1800 2361 3952 14028 Phenol 810 1003 6425 6150 Methylphenol 761 882 5485 7434 3- & 4-Methylphenol 1795 1846 15337 19723 2-Nitrophenol 422 474 311 2315 2,4-Dimethylphenol 1344 1476 15000 20710 2,4-Dichlorophenol 5396 8138 19803 61664 2,6-Dichlorophenol 2991 5858 12511 48530 4-Chloro-3-methylphenol 2398 3137 24060 33529 2,4,5-Trichlorophenol 3115 11097 24270 96333 2,4,6-Trichlorophenol 9702 19307 35466 109492 2,4-Dinitrophenol 0 11 765 1182 4-Nitrophenol 626 730 11458 6536 2,3,4,6-Tetrachlorophenol 3108 27683 33938 70440 2-Methyl-4,6-dinitrophenol 55 47 920 1685 Pentachlorophenol 2305 40582 22056 143905 Dinoseb 68 2123 6676 37744 29

Phenols by SPME at 50ppb (85µm Polyacrylate Fiber, ph 2) IS 1 2 3 4,5 6 7 8 9 10 11 12 13 14 6 8 10 12 Min 14 16 18 15 16 IS 17 18 IS 2-Fluorophenol (int. std.) 1. Phenol 2. 2-Chlorophenol 3. 2-Methylphenol 4. 3-Methylphenol 5. 4-Methylphenol 6. 2-Nitrophenol 7. 2,4-Dimethylphenol 8. 2,4-Dichlorophenol 9. 2,6-Dichlorophenol 10. 4-Chloro-3-methylphenol 11. 2,4,5-Trichlorophenol 12. 2,4,6-Trichlorophenol 13. 2,4-Dinitrophenol 14. 4-Nitrophenol 15. 2,3,4,6-Tetrachlorophenol 16. 2-Methyl-4,6- dinitrophenol IS 2,4,6-Tribromophenol 17. Pentachlorophenol 18. Dinoseb 30

Quantification Internal Standard!! For complex Matrices Standard Addition Extraction is an Equilibrium!! Extraction parameter needs to be kept constant: Stir velocity Temperature Sample matrix (Salt?) Fiber position in the sample Extraction time 31

Conclusion One Step Extraction Micro Technology Trace Analysis 100% Solvent Free Equilibrium Technology Control your T s (Time, Temp., Technique) Suitable for Liquids (Water), Gases or Solids Quantitative Automation possible CTC Gerstel Varian Thermo 32

Supelco SPME Bulletins # 925 SPME-Applications Guide (only on CD & web) # 923 Theory and Optimization of Conditions # 928 Trouble Shooting guide # 929 Practical Guide to Quantification SPME # 901 Drugs, Alcohol, org. Solvents in Biological Fluids # 922 Forensic Applications: Explosives, Fire Debris, and Drugs of Abuse # 869 Flavour and Fragances All on the SPME-CD plus additional applications & videos 33

Dziękuję za uwagę! S ample P rep M ade E asy 34