Thermo Scientific LC IsoLink

Similar documents
Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

MetWorks Metabolite Identification Software

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Thermo Scientific irm-gc/ms Technology

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

LTQ XL Linear Ion Trap Mass Spectrometer More Structural Information with MS n

Thermo Scientific GasBench II

Thermo Scientific DELTA V Advantage DELTA V Plus

LCQ Fleet Ion Trap LC/MS n Exceptional Analytical Value

Thermo Scientific TPDRO 1100 Advanced Catalyst Characterization

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap

TPDRO 1100 Advanced Catalyst Characterization. For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

of mass spectrometry

Finnigan TSQ Quantum Discovery MAX

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Finnigan TRITON Finnigan NEPTUNE. High Resolution Multicollector Mass Spectrometers

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

DFS Magnetic Sector GC/MS

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

for XPS surface analysis

EA-IRMS: Fast and Precise Isotope Analysis of Liquids on a Delta V Isotope Ratio MS with a High Temperature Conversion Elemental Analyzer

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

IN QUALITATIVE ANALYSIS,

Fast, Effective XPS Point Analysis of Metal Components

High-Field Orbitrap Creating new possibilities

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Thermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method

Finnigan TRACE DSQ GC/MS

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

HILIC Method Development in a Few Simple Steps

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

irm-lc/ms: δ 13 C Analysis of RNA

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Thermo Scientific ITQ Series Quadrupole Ion Trap GC/MS n

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Complete Materials Deformulation Using TGA-IR

Monitoring Protein PEGylation with Ion Exchange Chromatography

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Automated and accurate component detection using reference mass spectra

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Food authenticity and adulteration testing using trace elemental and inorganic mass spectrometric techniques

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

Elemental Analysis: NCS characterization of paper

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

Speed and flexibility

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Enhancement of Linearity and Response in Charged Aerosol Detection

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

HYPHENATED TECHNOLOGY GUIDE

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Transcription:

m a s s s p e c t r o m e t r y Thermo Scientific LC IsoLink The Link from HPLC to Isotope Ratio Mass Spectrometry Carbohydrates Amino Acids, Nucleotides Organic Acids Pharmaceuticals Part of Thermo Fisher Scientific

Thermo Scientific LC IsoLink The Link from HPLC to Isotope Ratio MS The Thermo Scientific LC IsoLink is the first high sensitivity interface connecting HPLC with Isotope Ratio MS (IRMS) for reproducible and accurate on-line determination of 13 C/ 12 C isotope ratios. All organic compounds eluting from an HPLC column are analyzed while maintaining the chromatographic resolution, opening up a new frontier in the application of isotope ratio mass spectrometry. Unique Features of the LC IsoLink: On-line coupling of HPLC and Isotope Ratio MS Isotope ratio data acquired on an HPLC time scale Preserves the integrity of chromatographic resolution Sample analysis in the low nanomole range Accurate and reproducible results Direct injection of reference materials Maintenance-free operation High throughput Capability for full automation 2

Carbohydrates are one of the largest and most common families of molecules in life. They serve as energy resource, backbone of DNA and RNA, carrier of biologically active compounds, and as structure building material in plants. Sugars can carry information of their origin and processing. If isotopically labeled, they tell us about their pathways and use. Because pharmaceuticals are produced at various sites with different prices and different formulations, it is essential for both the producers and consumers to be able to distinguish between originals and generics. Aspirin and Paracetamol are representatives of mass produced drugs with a wide range of origin and price. Sugars on a cation exchange column. Drugs on a HyPURITY AQUASTAR HPLC column. for a wide Range of The Thermo Scientific LC IsoLink is built to directly address the analysis of polar and thermolabile compounds. Most of these compounds (such as amino acids, peptides, carbohydrates, nucleotides, alcohols, organic acids, sulfa drugs, and many more) can be chromatographically separated in aqueous phase using inorganic buffers on ion exchange, size exclusion, or specific reversed phase HPLC columns. The LC IsoLink enables the on-line high precision determination of the 13 C/ 12 C isotope ratio of each separated component. Applications... Metabolism Studies Tracer experiments with amino acids, lipids, carbohydrates Nucleotide analysis for DNA synthesis rates Food and Food Ingredients Authentication of honey and fruit juices Determining origin of flavors and nutrients Analysis of phospholipids, carbohydrates, amino acids and vitamins Pharmaceuticals Authenticity control of drugs Investigation of agents and additives Doping control Analysis of steroids and hormones Biogeochemistry History of biomolecules in sediments and soils 3

Thermo Scientific LC IsoLink Amino acids and peptides are the basic elements for building proteins. Their structure and metabolism are of major interest in medicine and biology. Either naturally occurring isotope differences or labelling experiments can be used to give insight into their pathways. Archaeological Bone Collagen The reconstruction of ancient diets using body tissue stable isotope values is an important aspect of paleodietary studies which provide archaeological science with a quantitative understanding of what people consumed in the past. Isotopic studies of diet are based on the principle You are what you eat, and collagen, being a well-preserved protein found in bone, has been most often used for these purposes. Isotopic signatures of individual amino acids can differ consistently and widely from each other. More dietary information is potentially available at the individual amino acid level. Separation of up to 18 amino acids can be performed on a single HPLC column. Short-chained peptides and amino acid on a C18 reversed phase endcapped column. irm-lc/ms chromatogram of archaeological bone collagen hydrolysate. The Concept of HPLC Coupling to IRMS Until now, the analysis of organic samples for 13 C/ 12 C isotope ratios was restricted to either on-line GC separation followed by combustion (isotope ratio monitoring GC/MS, irm-gc/ms) or bulk combustion of samples in an organic elemental analyzer. Biologically or pharmaceutically important compounds are often not GC-volatile or too thermolabile to be separated by gas chromatography. 13 C/ 12 C isotope ratio determination of these compounds in real analytical applications, typically within complex matrices, was so far either impossible or extremely labor intensive. The patented LC IsoLink* leapfrogs the hurdle that, until now, has prevented successful isotope ratio monitoring LC/MS, namely the quantitative, fractionation-free elimination of the liquid phase prior to the oxidative conversion of the sample into CO 2. In the LC IsoLink, the liquid phase is not removed from the sample prior to oxidation but the sample is oxidized while still within the aqueous solution, and only afterwards the CO 2 is separated from the liquid phase for isotopic analysis. This process is quantitative and fractionation-free in the LC IsoLink. The oxidation reagent consists of two solutions, the oxidizing agent and phosphoric acid. Both are pumped separately and added to the mobile LC phase. All individual organic compounds eluting from the HPLC column are oxidized quantitatively into CO 2 within this mixture when passing through a heated reactor. In a downstream degassing unit, the CO 2 is removed from the liquid phase and entrained into a stream of He. The individual CO 2 peaks in He are subsequently dried in an on-line gas drying unit (Nafion ) and then admitted to the Isotope Ratio MS via an open split interface. Since the liquid phase is not vaporized at all, inorganic buffers, e.g. phosphate buffers, have no influence on the operation of the interface, and can not accumulate anywhere in the system. This is in marked contrast to any other LC/MS interface and makes the LC IsoLink essentially maintenance free. 4 *GB2388800 B, US7213443 B2

RNA Nucleotides: Molecular biological methods based on detection, sequencing, and phylogenetic identification of ribosomal RNA (rrna) and the genes encoding it (rdna) allow description of natural microbial communities without isolation and culturing of individual species. By carbon isotopic characterization of rrna species identity can be linked with carbon source utilization. Organic acids play an important role in the metabolism of plants. They are involved in various anabolic and catabolic processes of metabolic pathways, such as citric acid cycle. m/z 44 (mv) Time (s) irm-lc/ms analysis of NaOH-hydrolyzed E. coli RNA, LB-grown. irm-lc/ms chromatogram (m/z 44 trace) of an organic acid mixture. Principle of HPLC Coupling to IRMS 5

Thermo Scientific LC IsoLink Analysis of an Extract of Geranium Pratense Changes in the isotopic signature of organic acid are studied in the process of ontogenesis of plants. Investigations can be important to understand development of plant metabolism and to estimate the impact of environmental factors. The most dominant organic acids in an extract of Geranium Pratense are malic acid and citric acid. Malic acid is isotopically heavier than citric acid. Plant metabolism study of organic acids. Isodat Software Suite The irm-lc/ms system is fully automated and controlled by the Isodat software suite. The Thermo Scientific Surveyor LC is completely integrated, other HPLC systems are synchronized by contact closure. The LC IsoLink and the mass spectrometer are entirely under full computer control, resulting in analyses with no user interaction. When coupled to any autosampler, the system can be operated fully unattended for high sample throughput and high productivity. The irm-lc/ms does not require any manual intervention during operation except for refilling of the reagents. Data evaluation and report generation are fully automated by Isodat software suite. Since the interface has only few variables, e.g. flow of oxidizing agent and He-flow, method development and operation are also exceedingly simple. Easy and fast method and sequence setup for Isotope Ratio MS and LC IsoLink Complete control and automation of all interface functions before and during data acquisition Automated peak and background detection Fully automated ion correction for isobaric ion contribution such as 12 C 17 O 16 O on 13 C 16 O 16 O Full access to all raw and processed data Complete raw data integrity and secure sample identity Software suite flexible export of evaluated data to Excel, other spreadsheet programs and databases (LIMS) Customized printouts and data export Full network compatibility with direct and fast access to Windows tools Complete Isodat software suite system backup using the Isodat Version Handler Based on the unique Plug and Measure concept of Thermo Scientific Isotope Ratio MS (Thermo Scientific DELTA V Advantage, DELTA V Plus and MAT 253), the LC IsoLink is immediately recognized and operational 6

Confirmation of Synthetic Testosterone The administration of synthetic testosterone is detected by the testosterone/epitestosterone (T/E) ratio in urine using GC/MS. Confirmation is performed by irm-gc/ms. The 13 C/ 12 C ratio of synthetic testosterone differs from the 13 C/ 12 C ratio of endogenous testosterone. The range of applications for the LC IsoLink can be extended by high temperature HPLC. At elevated temperatures, water acts like a weak polar organic solvent. Therefore, it s also capable of separating mid polar and even non-polar analytes. Steroids can be separated under 100% aqueous conditions, selectivity can be tuned by temperature. Analysis of steroids in urine (LC fraction) by high temperature HPLC coupled to IRMS. Analytical Performance Accuracy, Precision and Sensitivity Accuracy and precision has been tested using standards with certified isotope ratios. The δ 13 C value of 400 ng of benzoic acid analyzed by repetitive loop injection has been shown to be correct within 0.08 with a reproducibility of 0.11. These values compare favorably with the accuracy and precision achievable with bulk analysis by Elemental Analyzer Isotope Ratio MS but require 100 times less sample. The sensitivity of the integrated irm-lc/ms system is sufficient to allow the isotope ratio determination of 13 C/ 12 C on sample amounts as low as 50 ng in direct injection mode. The minimum amount in HPLC mode depends on the background created by the HPLC column bleed. Acceptance Specifications After installation, the system performance of the LC IsoLink will be demonstrated by direct loop injection, to show an external precision of < 0.3 for δ 13 C (n=5). This requires an organic-free HPLC pump. Mass Spectrometer DELTA Series and MAT 253 LC IsoLink Basic Performance 10 pulses of reference gas (amplitude 3V), δ notation Precision (1σ) Linearity CO 2 13 C 0.06 0.02 /na External precision using the LC IsoLink (n=5, 1σ), δ notation Benzoic Acid (direct loop injection) 400 ng in 10 µl of water 3 nmol Benzoic Acid 21 nmol (250 ng) C as CO 2 < 0.3 7

Installation Requirements In addition to these offices, Thermo Fisher Scientific maintains a network of representative organizations throughout the world. Power 230 V single phase, 8 A Gases He, better 99.999% CO 2, better 99.995% Supplies Water (HPLC grade) Reagent Catalyst Recommended Supplies Thermo Scientific Surveyor HPLC system with MS pump Thermo Scientific columns Thermo Scientific LC IsoLink Dimensions Literature Krummen, M., A. W. Hilkert, D. Juchelka, A. Duhr, H.-J. Schlüter and R. Pesch: A new concept for isotope ratio monitoring liquid chromatography/mass spectrometry. Rapid Commun. Mass Spectrom. 2004; 18: 2260-2266. USA, 1991, 21.-26.05.1994, 875 Analytical data is available in the LC IsoLink Application Notes. Laboratory Solutions Backed by Worldwide Service and Support Tap our expertise throughout the life of your instrument. Thermo Scientific Services extends its support throughout our worldwide network of highly trained and certified engineers who are experts in laboratory technologies and applications. Put our team of experts to work for you in a range of disciplines from system installation, training and technical support, to complete asset management and regulatory compliance consulting. Improve your productivity and lower the cost of instrument ownership through our product support services. Maximize uptime while eliminating the uncontrollable cost of unplanned maintenance and repairs. When it s time to enhance your system, we also offer certified parts and a range of accessories and consumables suited to your application. To learn more about our products and comprehensive service offerings, visit us at www.thermo.com. Africa +43 1 333 5034 127 analyze.emea@thermo.com Australia +61 2 8844 9500 analyze.au@thermo.com Austria +43 1 333 50340 analyze.at@thermo.com Belgium +32 2 482 30 30 analyze.be@thermo.com Canada +1 800 530 8447 analyze.ca@thermo.com China +86 10 8419 3588 analyze.cn@thermo.com Denmark +45 70 23 62 60 analyze.dk@thermo.com Europe-Other +43 1 333 5034 127 analyze.emea@thermo.com France +33 1 60 92 48 00 analyze.fr@thermo.com Germany +49 6103 408 1014 analyze.de@thermo.com India +91 22 6742 9434 analyze.in@thermo.com Italy +39 02 950 591 analyze.it@thermo.com Japan +81 45 453 9100 analyze.jp@thermo.com Latin America +1 608 276 5659 analyze.la@thermo.com Middle East +43 1 333 5034 127 analyze.emea@thermo.com Netherlands +31 76 579 55 55 analyze.nl@thermo.com South Africa +27 11 570 1840 analyze.sa@thermo.com Spain +34 914 845 965 analyze.es@thermo.com Sweden / Norway/ Finland +46 8 556 468 00 analyze.se@thermo.com Switzerland +41 61 48784 00 analyze.ch@thermo.com UK +44 1442 233555 analyze.uk@thermo.com USA +1 800 532 4752 analyze.us@thermo.com www.thermo.com Thermo Fisher Scientific (Bremen) GmbH is certified DIN EN ISO 2001:9000 2005, 2008 Thermo Fisher Scientific Inc. All rights reserved. Aspirin is a registered trademark of Bayer AG. Nafion is a registered trademark of Dupont and/or its affiliates. Windows is a registered trademark of Microsoft Corporation. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR30039_E 03/08C