Charged Aerosol Detection 101

Similar documents
Corona Veo the Next Generation Charged Aerosol Detector

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

Discover what you re missing

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

No Chromophore? No Problem! Universal HPLC Detection. The world leader in serving science

Charged Aerosol Detection and Evaporative Light Scattering Detection Fundamental Differences Affecting Analytical Performance

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

for Acclaim Trinity TM P1

Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Direct Analysis of Surfactants using HPLC with Charged Aerosol Detection

Enhancement of Linearity and Response in Charged Aerosol Detection

A Platform Method for Pharmaceutical Counterion Analysis by HPLC

Agilent 385-ELSD Evaporative Light Scattering Detector

Charged Aerosol Detection See what other universal detectors are missing. Technical Guide

Agilent 385-ELSD Evaporative Light Scattering Detector

Analysis of Silicone Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Metoprolol and Select Impurities Analysis Using a Hydrophilic Interaction Chromatography Method with Combined UV and Charged Aerosol Detection

Dionex IonPac AS28-Fast-4µm column

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

HPLC Analysis of Non-volatile Analytes Using

Cation Exchange HPLC Columns

Varian 385-LC. ELSD for Low Molecular Weight Compounds

Selecting Detectors for Compounds with No Optical Absorbance

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Quantitation and Characterization of Copper and Nickel Plating Bath Additives by Liquid Chromatography

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Fast methods for the determination of ibuprofen in drug products

HPLC Analysis of Nonvolatile Analytes Using Charged Aerosol Detection

Acclaim AmG C18 Column

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Acclaim Mixed-Mode WCX-1

Analytical Methods to Qualify and Quantify PEG and PEGylated Biopharmaceuticals

columns IonPac AS18 Anion-Exchange Columns

columns IonPac AS17-C Anion Exchange Column

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Evaporative Light Scattering Detector (ELSD)

Acclaim HILIC-10 Columns

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Varian 380-LC. ELSD for Routine HPLC and GPC Analysis. Key Benefits

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Expanded capabilities in ammonium and amine detection

Use of Charged Aerosol Detection as an Orthogonal Quantification Technique for Drug Metabolites in Safety Testing (MIST)

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Analysis of pharmaceuticals using HPLC with evaporative light scattering detection

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

columns IonPac AS22 Anion-Exchange Column

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

New Developments in Surfactant Analysis Using HPLC

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

for Acclaim Mixed-Mode WCX-1

LC and LC/MS Column Selection Flow Chart

anion-exchange column

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

APPLICATION NOTE Goal. Introduction. Keywords

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

LC Technical Information

Application Specific HPLC and UHPLC Columns

Thermo Scientific Acclaim Surfactant Plus Column

Thermo Scientific. Anion-Exchange Column

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS

HPLC analysis of VFAs, Furfural and HMF

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

ChromTech HPLC System

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

for Acclaim Mixed-Mode HILIC-1 Column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited

NANO 243/CENG 207 Course Use Only

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System


Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Advances in Sample Preparation for Accelerated Solvent Extraction

MODERN HPLC FOR PRACTICING SCIENTISTS

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Monitoring Protein PEGylation with Ion Exchange Chromatography

Acclaim Mixed-Mode WAX-1 Columns

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE

Cation Exchange HPLC Columns

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Determination of trace anions in concentrated hydrofluoric acid

Chromatography. writing in color

Transcription:

Charged Aerosol Detection 101 Dr. Alexander Schwahn European Sales Support Expert for Biopharma Industry Thermo Fisher Scientific, Reinach, Switzerland The world leader in serving science

Outline Introduction to charged aerosol detection (CAD) How charged aerosol technology works Comparison of CAD to ELSD CAD product evolution Example applications Summary 2

Introduction to Charged Aerosol Detection (CAD) Used to quantitate any non-volatile and many semi-volatile analytes with LC Provides consistent analyte response independent of chemical structure and molecule size Neither a chromophore, nor the ability to ionize, is required for detection. Dynamic range up to four orders of magnitude from a single injection (sub-ng to µg quantities on column) Mass sensitive detection CAD provides relative quantification without the need for reference standards Compatible with gradient conditions for HPLC, UHPLC, and micro LC Comparison of charged aerosol detection to UV and MS 3

Charged Aerosol Detection How It Works Flow path through a Thermo Scientific Dionex Corona Veo charged aerosol detector 1 Inlet from column 6 Corona charger 2 FocusJet concentric nebulizer 7 Mixing chamber 3 Gas inlet 8 Ion trap 4 Micro drain pump 9 Electrometer 5 Evaporation tube 10 Gas exhaust 5 2 1 8 9 3 4 7 10 6 4

Charged Aerosol Detection How It Works Flow path through a Thermo Scientific Dionex Corona Veo charged aerosol detector FocusJet Concentric nebulizer tip Heated evaporation sector Signal is proportional to the analyte quantity Electrometer HPLC eluent Ion trap N 2 Active drain pump Mixing chamber N 2 Corona charger 5

Particle Charging for Charged Aerosol Detection Particle size proportional to mass of analyte Charge per particle proportional to particle size Charged particles are measured, not gas phase ions as in MS (Independent of analyte net charge). CAD response depends on initial mass concentration of analyte in droplets formed but is independent of its chemical properties. Nearly uniform detector response However, sample needs to be non-volatile or at least only semi-volatile. Dried particles Charged particle Charged gas ions Diffusional charging of aerosol in mixing chamber 6

ELSD vs. CAD Evaporative light scattering detector (ELSD) Charged aerosol detector Detection chamber Nebulizer Evaporation tube Heated nebulizer Siphon PMT Light source Evaporating chamber Charged particles Drain Corona charger Electrometer Particle size is proportional to mass of analyte + background residue Measures the optical reflection of solute particles after the sample has been passed through a nebulizer Measures charged particles by an electrometer generating a signal that is proportional to particle size (Mass of analyte) after nebulization 7

Detector Response Characteristics ELSD CAD Response Narrow linear segment Response Expanded linear segment Mass on Column For Rayleigh scattering: b = 2 For Mie scattering: b = 1⅓ For Refraction and reflection scattering: b = ⅔ Mass on Column Nonvolatiles - Decreasing slope with increasing mass (b ~ ⅔) ELSD exhibits a narrower linear calibration range than CAD. 8

Detector Response Characteristics Apramycin and impurities 9

Detector Response Characteristics Apramycin and impurities 10

Calibration Consideration with Using Universal Detectors Over short ranges, both ELSD and charged aerosol detector can offer linear response. All aerosol-based detectors exhibit a non-linear response over large concentration ranges. Several calibration curve approaches are available: Selections ELSD Sigmoidal response behavior Log-log Point to point CAD Parabolic response behavior Log-log Quadratic Power function The most appropriate approach depends upon the data. 11

Comparison Review Feature Evaporative light scattering Charged aerosol Response Sigmoidal Curvilinear Dynamic range 2 3 orders >4 orders LoQ and LoD LoQ and LoD often higher (Worse) than estimated by SNR LoQ and LoD often lower (Better) than estimated by SNR Sensitivity (LoD) >10 ng <1 ng Semi-volatility range Analyte response Flow rate range (0.2 2 ml/min) Similar Variable - Dependent on compound Possibly several nebulizers Similar Independent of structure One nebulizer Ease of operation Can be complex Simple 12

Evolution of Charged Aerosol Detectors 2015 Thermo Scientific Full integration with Thermo Scientific Vanquish Vanquish charged UHPLC platform, slide-in module design, reduced aerosol detector flow path for optimum operation 2013 Corona Veo RS Extended micro flow rate range; total CAD redesign with concentric nebulization and optimized spray chamber for enhanced sensitivity, heated evaporation and electronic gas regulation Dionex Corp. acquired by Thermo Fisher Scientific Inc. 2011 2009 Corona ultra RS CAD ESA Biosciences, Inc. acquired by Dionex Corp. Corona ultra CAD Unified with Dionex UltiMate 3000 UHPLC + system, added on-board diagnostics / monitoring, automated flow diversion capability and selection of linearization parameters UHPLC compatible, stackable design, enhanced sensitivity, touchscreen user interface with real-time chromatogram display, incorporated precision internal gas regulation system 2006 2005 Corona Plus Expanded solvent compatibility with heated nebulization, software drivers CAD for popular CDS systems and external gas conditioning module for improved precision. Corona CAD Introduction of the first commercial charged aerosol detector for HPLC with full control via front panel interface. Designed for near-universal detection on any HPLC system using isocratic or gradient separations 13

Corona Veo and Vanquish Charged Aerosol Detectors Concentric nebulization system improves sensitivity and precision. Thermally controlled evaporation scheme widens the scope of applications. Corona Veo and Vanquish RS model includes low flow capabilities for micro LC, as well as UHPLC. Usability and serviceability have been enhanced. CDS drivers available for use with all Thermo Scientific and many other vendor systems. Vanquish CAD FocusJet Corona Veo RS 14

Pharma and Biopharma Application Areas Drug composition Impurity testing Formulation Counterions Surfactants / Excipients Degradation / Stability testing Characterization Glycan analysis Adjuvant analysis Excipient raw material analysis and lot-to-lot variability 15

Pharma and Biopharma Application Areas Drug composition Impurity testing Formulation Counterions Surfactants / Excipients Degradation / Stability testing Characterization Glycan analysis Adjuvant analysis Excipient raw material analysis and lot-to-lot variability Cleaning validation Mass balance Extractables / Leachables PEGylation and antibody-drug conjugates sirna lipid delivery vehicles QbD MIST (Metabolites in safety testing) Visit the charged aerosol detection website and the free Thermo Scientific AppsLab library of analytical applications, to see more examples of HPLC-CAD solutions: www.thermofisher.com/cad www.thermofisher.com/appslab 16

Drug Composition Example: Aminoglycoside Antibiotic Analysis of Gentamicin standard (200 μg/ml) Column: Thermo Scientific Acclaim RSLC PolarAdvantage II, 2.2 μm, 2.1 100 mm Mobile phase A: 0.025:95:5 HFBA:water:acetonitrile Mobile phase B: 0.3:95:5 TFA:water:acetonitrile Gradient: 0 to 1.5min,1 to 10%B 1.5 to 7min,10 to 100% B 7 to 10min,100% B 4 min. pre-injection equilibration Flow rate: 0.45 ml/min Inj. volume: 1 μl Detector: Corona ultra RS, 15 C, 60 Hz 17

Orthogonal and Complimentary Detection with DAD and CAD Metoprolol and impurities A, M and N 50 40 30 Response [pa] 20 10 0 Impurity A Impurity M Metoprolol CAD Impurity N UV @ 280nm -20 0 1 2 3 4 5 6 7 8 9 10 Time [min] Isocratic HILIC chromatographic method using both UV and charged aerosol detection 18

Formulation Counterions Drug counterions Instrumentation: Thermo Scientific Dionex UltiMate 3000 RSLC system Column: Acclaim Trinity P2, 3 μm, 3 50 mm Col. temp: 30 ºC Flow rate: 0.6 ml/min Inj. volume: 2 μl Mobile phase A: Water Mobile phase B: 100 mm ammonium formate, ph 3.65 Gradient: Time -8.0 0.0 1.0 11 15 (min) %A 90 90 90 0 0 %B 10 10 10 100 100 Charged aerosol: Sample: Corona Veo RS; 55 ºC, 5 Hz, 2 s, PF 1.5 20 to 100 ng/µl each in deionized water Peaks 1. Phosphate 7. Nitrate 2. Sodium 8. Citrate 3. Potassium 9. Fumarate 4. Chloride 10. Sulfate 5. Malate 11. Magnesium 6. Bromide 12. Calcium Anions, cations, organic and inorganic ions simultaneously 19

Formulation Counterions Drug counterions Instrumentation: UltiMate 3000 RSLC system Column: Acclaim Trinity P2, 3 μm, 3 50 mm Col. temp: 30 ºC Flow Rate: 0.6 Sulfonated ml/min nano-polymer bead Inj. Volume: 2 μl Mobile Phase A: Water Anion-exchange /HILIC Mobile Phase B: 100 mm functionality ammonium in inner formate, pore ph area 3.65 Gradient: Time -8.0 0.0 Sulfonated 1.0 nano-polymer 11 15 (min) beads attached to surface %A 90 90 90 0 0 %B 10 10 10 100 100 Charged Aerosol: Sample: Corona Veo RS; 55 ºC, 5 Hz, 2 s, PF Nano-polymer/Silica 1.5 20 to 100 ng/µl each hybrid in deionized particle water Peaks 1. Phosphate 7. Nitrate 2. Sodium 8. Citrate 3. Potassium 9. Fumarate 4. Chloride 10. Sulfate 5. Malate 11. Magnesium 6. Bromide 12. Calcium Anions, cations, organic and inorganic ions simultaneously 20

Formulation API and Counterions Adderall (Shire Pharmaceuticals) and counterions Instrumentation: UltiMate 3000 RSLC system Column: Acclaim Trinity P2, 3 μm, 3 50 mm Col. temp: 30 ºC Flow rate: 0.6 ml/min Inj. volume: 5 μl Mobile phases: A: Acetonitrile B: Water C: 100 mm ammonium formate, ph 3.65 UV @ 254 nm Gradient: Time (min) A B C -8.0 35 59 6 0.0 35 59 6 0.5 35 59 6 5.0 35 0 65 10 20 0 80 12 20 0 80 CAD UV detector: UV diode array; 254 nm, 5 Hz, 0.5 s Charged aerosol: Corona Veo RS; 55 ºC, 5 Hz, 2 s, PF 1.5 Peaks: 1 aspartate 24 µg/ml 2 sodium 3 saccharin 24 µg/ml 4 amphetamine 122 µg/ml 5 sulfate 26 µg/ml Ref: AN20870 Complimentary detection by CAD and UV/Vis 21

Formulation API, Counter-Ions and Impurities Analysis of diclofenac sodium salt (1 mg/ml) Column: Acclaim Trinity P1, 3 μm, 3.0 50 mm Mobile phase A: 75% Acetonitrile Mobile phase B: 25% 200 mm Ammonium acetate ph 4 Flow rate: 0.8 ml/min Inj. volume: 5 μl Col. temp: 30 ⁰C Detector: Corona Veo RS CAD Evap. temp: 60 ⁰C Charged aerosol even detects chloride impurity. 22

Stability Forced Degradation Corona ultra RS CAD Follow forced degradation of Amikacin sulfate 23

Food and Beverage Application Areas Simple carbohydrates Lipids Profiling methods Targeted methods Artificial sweeteners 25

Food and Beverage Simple Carbohydrates Analysis of simple sugars Add 20 ml of 85% ACN to 1 gram juice, mix & spin Std. Grape Cranberry Apple Orange Isocratic HILIC separation Corona Ultra RS CAD Simplified sample preparation Dilute-and-shoot method 26

Lipids Profiling Global lipids Algal oils Column: Thermo Scientific Accucore C18, 2.6 μm, 3.0x150 mm Mobile phases: A: Methanol:water:acetic acid (600:400:4) B: Tetrahydrofuran:acetonitrile (50:950) C: Acetone:acetonitrile (900:100) Gradient: Time FlowRate %A %B %C (min) (ml/min) -10.0 1. 00 90 10 0-0.1 1. 00 90 10 0 0. 0 0. 25 90 10 0 20.0 0. 50 15 85 0 35.0 0. 50 2 78 20 60.0 0. 50 2 3 95 65.0 0. 50 90 10 0 Flow rate: 1.0 ml/min Inj. volume: 2 μl Col. temp: 40 ⁰C Detector: Corona Veo RS CAD Evap. temp: 40 ⁰C Complex sample Minimal sample prep 27

Lipids Targeted Methods Olive oil Sunflower oil Column: Thermo Scientific Hypersil ODS C18 5 μm, 4.6 250 mm, 2 in series, plus 2 in series for gradient compensation Mobile phase A: 2-propanol:hexane 1:1 (v/v) Mobile phase B: Acetonitrile Gradient: Time Flow rate %A %B (min) (ml/min) 0.0 1 20 80 80 1 90 10 Inverse gradient: Yes Flow rate: 1.0 ml/min Inj. volume: 4 μl Col. temp: 30 ⁰C Detector: Corona CAD 100 pa; 35 psi, low filter Sample: B, TG standard GLC#435 and D) GLC#437, dissolved in hexane Reference: Sandra et al, J Chromatogr. A 1176 (2007) 135 142. Complex real samples minimal sample prep 28

Food Additives: Steviol Glycosides (Sweetener) R e s p o n s e 161 140 120 100 Stevioside Column: Acclaim Trinity P1, 3 µm, 2.1 150 mm Mobile phase: 88:12 (v/v) Acetonitrile:10 mm ammonium formate, ph 3.1 Flow rate: 0.8 ml/min Inj. volume: 2 µl Col. temp: 30 ⁰C Detection: Dionex Corona Veo RS CAD Settings: 2 Hz, 5 second filter, PF 1.0, evap. temp 35 ⁰C ELSD 74 15 Isosteviol C u r r e n t [ p A ] 10 5 Steviol Rubusoside Dulcoside A Stevioside Steviolbioside Rabaudioside C Rabaudioside F Rebaudioside B Rebaudioside A Sodium Rebaudioside D CAD 0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 Time [min] CAD exhibits more uniform response. 29

Artificial Sweeteners: Steviol Glycosides R e s p o n s e 161 140 120 100 Stevioside Column: Acclaim Trinity P1, 3 µm, 2.1 150 mm Mobile phase: 88:12 (v/v) Acetonitrile:10 mm ammonium formate, ph 3.1 Flow rate: 0.8 ml/min Inj. volume: 2 µl Col. temp: 30 ⁰C Detection: Dionex Corona Veo RS CAD Settings: 2 Hz, 5 second filter, PF 1.0, evap. temp 35 ⁰C ELSD 74 15 Isosteviol C u r r e n t [ p A ] 10 5 Steviol Rubusoside Dulcoside A Stevioside Steviolbioside Rabaudioside C Rabaudioside F Rebaudioside B Rebaudioside A Sodium Rebaudioside D CAD 0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 Time [min] CAD exhibits more uniform response. 30

Summary Charged aerosol detection delivers accurate and precise quantification of lipids, carbohydrates, surfactants, amines and counterions that UV/Vis absorbance cannot detect. For analytes with chromophores, charged aerosol detection provides uniform response independent of the extinction coefficient. Charged aerosol detection provides a good estimate of the amount of unknown impurities and degradation products. Charged aerosol detection is superior to ELSD in terms of sensitivity, dynamic range, response uniformity, precision and ease of use. More information on charged aerosol detection can be found at www.thermofisher.com/cad Bibliography of charged aerosol detector applications can be downloaded from http://analyteguru.com/resources/charged-aerosol-detection-list-ofpublished-articles/ 31

Thank You Very Much for Your Attention! Questions? Do you have additional questions or do you want to talk to an expert from Thermo Fisher Scientific? Please send an E-Mail to analyze.eu@thermofisher.com and we will get back to you. 32