Gas Chromatography Separation of H 2 -D 2 -Ar Using Pd/K

Similar documents
Improvement of Hydrogen Isotope Release on Lithium Orthosilicate Ceramic Pebble by Catalytic Metals

Fusion Fuel Cycle. ing. Stefan Ionut SPIRIDON. Association Days, Institutefor Cryogenics and Isotopes Technologies Rm.

Lecture 7. Sorption-Separation Equipment

Supporting Information

The Preparative Gas Chromatographic System of the JET Active Gas Handling System Tritium Commissioning and Use during and after DTE1

Effects of Water Vapor on Tritium Release Behavior from Solid Breeder Materials

Tritium Transport Modelling: first achievements on ITER Test Blanket Systems simulation and perspectives for DEMO Breeding Blanket

In-vessel Tritium Inventory in ITER Evaluated by Deuterium Retention of Carbon Dust

COMPUTER SIMULATION OF THE WATER AND HYDROGEN DISTILLATION AND CECE PROCESS AND ITS EXPERIMENTAL VERIFICATION

Tritium processing system for the ITER Li/V Blanket Test Module

Synthesis of isoalkanes over core (Fe-Zn-Zr)-shell (zeolite) catalyst

The dynamic adsorption of Xe on a fixed bed adsorber at 77 K

IL H DESIGN FOR KRYPTON-85 ENRICHMENT BY THERMAL DIFFUSION

Gas-Chromatographic Analysis of Mixtures of Hydrogen Isotopes Using Different Samples Loops

TRITIUM RECOVERY FROM WASTE USING A PALLADIUM MEMBRANE REACTOR

Key words: EcosimPro, model, simulation, detritiation.

TRITIUM PRODUCTION IN PALLADIUM DEUTERIDE/HYDRIDE IN EVACUATED CHAMBER

Strategic use of CuAlO 2 as a sustained release catalyst for production of hydrogen from methanol steam reforming

Studies on bi-directional hydrogen isotopes permeation through the first wall of a magnetic fusion power reactor

Successful Development of a New Catalyst for Efficiently Collecting Tritium in Nuclear Fusion Reactors

SOME CONSIDERATION IN THE TRITIUM CONTROL DESIGN OF THE SOLID BREEDER BLANKET CONCEPTS

An Overview of SRNL Tritium Activities

Tritium Control Using Carbon Outside of Core Stephen T Lam

Gas Chromatography. Introduction

Conceptual Design of Advanced Blanket Using Liquid Li-Pb

Pressure Swing Adsorption: A Gas Separation & Purification Process

NUCLEI. Atomic mass unit

Oscillating Flow Characteristics of a Regenerator under Low Temperature Conditions

Nuclear Energy Learning Outcomes

Nuclear Energy Learning Outcomes. Nuclear Fission. Chain Reaction

Chromatography and other Separation Methods

Temperature programmed desorption (TPD) studies on nuclear carbon materials charged with hydrogen at elevated temperatures

Lithium enrichment issues in the sustainable supply chain of future fusion reactors

CHAPTER 4. Atomic Structure. 4.1 Atoms. Dalton s Atomic Theory

Tritium Transport and Corrosion Modeling in the Fluoride Salt-Cooled High-Temperature Reactor

9.4 Effusion and Diffusion of Gases

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Chromatography. Gas Chromatography

Mechanisms for Heat Generation during Deuterium and Hydrogen Loading of Palladium Nanostructures

(ii) Compare the movement and arrangement of the molecules in solid nitrogen to those in nitrogen gas.

Disadvantage: Destructive Technique once analyzed by GC, the sample is lost

Role of Re and Ru in Re Ru/C Bimetallic Catalysts for the

Tritium Safety of Russian Test Blanket Module

Speed Distribution at CONSTANT Temperature is given by the Maxwell Boltzmann Speed Distribution

SEPARATION BY BARRIER

Separation of isotopes

Atomic Structure. The nuclear atom Electron Configuration. Ms. Thompson - SL Chemistry Wooster High School. Wednesday, July 15, 15

Fusion/transmutation reactor studies based on the spherical torus concept

ADSORPTION OF TOLUENE VAPOUR ON ACTIVATED CARBON FIBRE

Synthesis of condensed polynuclear aromatic resin from furfural extract oil of reduced-pressure route II

Supporting Information High Activity and Selectivity of Ag/SiO 2 Catalyst for Hydrogenation of Dimethyloxalate

Be prepared to discuss the quantitative comparison method in the oral exam.

Adsorption (Ch 12) - mass transfer to an interface

Aim: What are the two types of Nuclear. Reactions? Do Now: 1. Get into your groups and compare your answers to your homework.

System for Continuous Chemical and Isotopic Purification of Hydrogen for the MuCap Experiment

Nuclear Reactions A Z. Radioactivity, Spontaneous Decay: Nuclear Reaction, Induced Process: x + X Y + y + Q Q > 0. Exothermic Endothermic

HYDROGEN DISTILLATION AT THE DEUTERIUM REMOVAL UNIT OF MuCap EXPERIMENT

Intro to Chemistry and Physics/Pre-AP Chem UNIT 2 Atoms: The Building Blocks of Matter 2:1 Foundations of Atomic Theory

Isotope Effects on Tritium Mass Transfer in Li 17 Pb 83 Liquid Blanket

12 Moderator And Moderator System

FUSION NEUTRON DEUTERIUM HELIUM TRITIUM.

Tritium Inventories and Tritium Safety Design Principles for the Fuel cycle of ITER

Development of In-Situ Gas Analyzer for Hydrogen Isotopes in Fusion Fuel Gas Processing

New Specification 2018 Recurring Exam Questions. How Science Works. C1 - Particles. Atom with the same atomic number and different mass number

PROGRESS IN GAS-LOADING D/Pd SYSTEM. The feasibility of a self-sustaining heat generator

Implantation Energy Dependence on Deuterium Retention Behaviors for the Carbon Implanted Tungsten

Fission and Chain Reactions

Study of Control rod worth in the TMSR

A SUPERCONDUCTING TOKAMAK FUSION TRANSMUTATION OF WASTE REACTOR

Recent R&D Activities on Tritium Technologies in Tritium Process Laboratory (TPL) of Japan Atomic Energy Agency (JAEA)

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Cryogenic Viscous Compressor Development and Modeling for the ITER Vacuum System

EXCESS HEAT AND HEAT AFTER DEATH IN A GAS- LOADING HYDROGEN/PALLADIUM SYSTEM

CATALYTIC COMBUSTION OF HYD RO GEN/ AIR IN MICROCHANNEL REACTOR

[1] (c) Some fruits, such as bananas, are naturally radioactive because they contain the unstable isotope of potassium-40 ( K.

High Performance Liquid Chromatography

Measurement of the organic saturation and organic porosity in. shale

Distillation purification and radon assay of liquid xenon

Kinetics of Hydrogen Isotope Absorption for Well-Annealed Palladium-Platinum Alloys

Titanium for Long-Term Tritium Storage (U)

Episode 528: Controlling fission

Chromatographic Separation

Anomalous production of gaseous 4 He at the inside of DScathode during D 2 O-electrolysis

Synthesis of jet fuel range cycloalkanes with diacetone alcohol. from lignocellulose

Chemistry Lab Fairfax High School Invitational January 7, Team Number: High School: Team Members Names:

Adsorption Research of Polymer on Oil Sands in Qidongyi Block of Xinjiang Conglomerate Reservoir

Investigations on Performance of an Auto-Cascade Absorption Refrigeration System Operating with Mixed Refrigerants

turbine (a) (i) Which part of the power station provides thermal (heat) energy from a chain reaction?

Principles of Gas- Chromatography (GC)

Name: New Document 1. Class: Date: 83 minutes. Time: 82 marks. Marks: Comments:

Deuterium Gas Charging Experiments with Pd Powders for Excess Heat Evolution (II) Discussions on Experimental Results and Underlying Physics

Chapter 2 Section 1: Classifying Matter. Classification of Matter. Classification of Matter 9/5/15

Elements, Mixtures and Compounds

INTRODUCTION Strained Silicon Monochromator Magnesium Housing Windows for Monochromator Shutter and Collimator Fission Detector HOPG Monochromator

Role and Challenges of Fusion Nuclear Science and Technology (FNST) toward DEMO

2401 Gas (liquid) Chromatography

Elements, Compounds and Mixtures

Chapter 2 - Matter Chem 6 Notetaker

Basic research on condensed matter nuclear reaction using Pd powders charged with high density deuterium

Chapter Practice Test Grosser

Transcription:

Gas Chromatography Separation of H 2 -D 2 -Ar Using Pd/K FTP/P1-06 X. J. Qian 1), D. L. Luo 1), C. Qin 1), G. Q. Huang 1), W. Yang 1) 1) China Academy of Engineering Physics, Mianyang, SiChuan, P.R.China E-mail contact of main author: eagleqq@sina.com Abstract. A new type of gas chromatographic technique was developed using Pd/Kieselgur as functional materials. It could separate H 2 -D 2 -Ar mixtures near room temperature with simply operation procedure without introducing any other replacement gas. This method was investigated using 63g Pd/K with two cascaded columns. The palladium content of the Pd/K was about 38.1±0.1wt% with the particle sizes of 200~350 micrometer. The H-D separation was tested at different operation conditions including the columns temperatures, the feeding gases flux and hydrogen isotopes content. The average separation factor was 13.5 under the conditions of 273 K in the columns, 10SCCM as the feeding gas flux, and 2.6at% of hydrogen isotopes in the mixed gas. Deuterium content in outflow of the first column reached 89.01at% from 37.5at% in feed gas. The results show that the separation of protium-deuterium would be better when the protium and deuterium content in raw gas within 6at%, with a gas flux of 10SCCM and a lower temperature. The new chromatographic separation has a potential for separation and recovery of hydrogen isotope out of the tritium extraction systems in breeding Test Blanket Modules. Keywords: Hydrogen isotope; separation; Chromatography; Pd/K 1. Introduction Hydrogen isotope separation is the very important technology of deuterium and tritium nuclear fuel circle in fusion reactor. Many methods have been developed to separation hydrogen isotopes, such as cryogenic distillation [1,2], gas chromatography[3,4], thermal cycling absorption press[5,6]. These methods can meet the request of fusion reactor running, but these techniques aren t very consummate. For example, the cryogenic distillation would run at cryogenic temperature 20~25 K depending on the isotopic fraction, and this technique have some disadvantages, such as complex configuration, high running cost, large tritium holdup in system. Palladium has the best hydrogen isotope effect so far, so the palladium is selected as the hydrogen isotopes separation materials in gas chromatography to separate the hydrogen isotopes. Gas chromatography as a technique separation hydrogen isotope has been already studied and reported by other investigators. K. Watanabe[7,8] and their research group had do much work to separate hydrogen isotopes using gas chromatography with Pd-Pt. In this work, a new kind of gas chromatographic technique was developed to separate H 2 -D 2 -Ar mixtures by use of Pd/Kieselgur. The effluent gases out of the tritium extraction systems in breeding Test Blanket Modules (TBMs) are mostly tritium-deuterium-helium mixtures. Because of the tritium radioactivity, the hydrogen isotopes T 2 -D 2 were displaced by H 2 -D 2 in

this work. The basic process of this method as follows: when H 2 -D 2 -Ar mixtures pass through a Pd-column, H 2 is absorbed by Pd firstly, and then D 2 is absorbed and displaced gradually by H 2 in mixtures. The different distribution of H 2 D 2 content is formed later in lengthways of column. When the absorption of protium is saturated, the outflow from column is pure D 2 and can be collected. When protium is detected from outflow, the gases in column will be pure H 2. In this way, separation of H 2 D 2 is achieved. 2. Experiments 2.1. Materials Gases used were the mixtures of Ar, H 2 and D 2. Their purities were guaranteed as 99.99%, 99.9% and 99.7%, respectively. Pd/Kieselgur manufactured by Northwest University of China was used as functional materials packed in separation columns. The palladium content of Pd/K whose particle sizes were 200~350 micrometer was about 38.1±0.1wt %. The specific surface area of Pd/K was 0.7575m 2 /g by BET method using Kr at liquid nitrogen 77K in AUTOSORB-1. Fig. 1 shows the surface appearance and the primary component of Pd/K powders analyzed by scanning electron microscope. The light part in fig.1 was the kieselgur. The surface of kieselgur and Pd was rough and had many anomalous holes which were propitious to the reaction of materials with hydrogen isotopes and the exchange of hydrogen isotopes. FIG.1. The SEM image and EDS of Pd/K

2.2. Apparatus The gas chromatographic system mainly consisted of two separation columns, a raw gas reservoir, columns cooling and heating equipment and so on. They were connected to each other with stainless steel tubes. The two columns connected in series packed with about 63g Pd/K were made of copper tube of 0.6cm in diameter and 250cm 270cm in length. The columns were combined with a quadrupole mass spectrometer from In Process Instruments with the model number of GAM 400. To measure the content of hydrogen isotope, a part of the effluent gas from the end of each column was introduced into the quadrupole mass spectrometer through a valve and analyzed with the mass spectrometer 2.3. Procedures The Pd/K packed in the columns was preheated at 523K in a flow of H 2 gas at a flux of 15SCCM for 2h to remove adsorbed impurities on the surface. Subsequently, the columns were cooled to a given operation temperature. During this procedure, the raw gas mixtures of Ar, H 2 and D 2 passed through the two columns in a given operation temperature and flux, the effluent gas was introduced into the mass spectrometer after about 4~5 min. The two columns were sampled in turn at a 2 min interval, namely, the effluent gas of the first column was firstly introduced into the mass spectrometer, and then the effluent gas of the second column was introduced into the mass spectrometer after 2 min. The pressure of raw gas was controlled at about 0.3MPa and the pressure of the system was kept at about 0.1MPa during the experiment. The separation factor of protium and deuterium in the column as follows: q c / c H D inlet H, D (1) c H / c D outlet c H and c D were stand for the mol percentage of protium and deuterium, respectively. 3. Results and Discussion 3.1. Temperature Dependence Fig.3 shows the temperature dependence of the separation for the raw gas mixture with 1.63%H 2-0.97%D 2-97.4%Ar, where the flux was 10SCCM and the temperatures were 273K 298K 313K,respectively. The ordinate shows the mol percentage of the protium and deuterium in the effluent gas, as determined with the mass spectrometer. The abscissa gives the collection counts after injection the raw gas into the columns. It was observed that deuterium eluted from the column faster than protium and the hydrogen isotopes eluted from column 1 faster than column 2. The hydrogen isotopes eluted from column 1 after 150 min and they didn t elute from column 2 in 250 min at 273K. The hydrogen isotopes eluted from two columns after 84 min, 170 min at 298K, respectively and

the hydrogen isotopes eluted from two columns after 60 min, 140 min at 313K, respectively. This figure also indicated that the affection on separation of temperature was remarkably, when the column temperature was higher, the hydrogen isotopes can elute from the columns faster. FIG.2. Content Change of H D in the effluent gases at different column temperatures Fig. 3 is the hydrogen isotope separation factor of column 1 with different temperatures. The affection on separation factor of temperature is evident. Because the hydrogen isotope effect of palladium is opposite to the temperature, the lower columns temperature is good for the H-D separation and then the H-D separation factor is higher, it had been validated by the results in Fig.3. At the lowest temperature of 273K, the average of H-D separation factor was 13.5. The hydrogen isotope content was 62.5%H-37.5%D in raw gas and reached 10.99%H-89.01%D after separation in column 1, so the deuterium was enriched. FIG.3. H-D separation factor of column 1 at different temperatures 3.2. Flux Dependence Fig.4 shows the flux dependence of the separation for the raw gas mixture with 0.6%H 2-0.6%D 2-98.8%Ar, where the temperature was 298K and the fluxes were 3SCCM 10SCCM 15SCCM 25SCCM,respectively. The hydrogen isotopes didn t elute from two columns in 150 min at 3SCCM. At 10SCCM, the hydrogen isotopes eluted from column 1 after 110 min and the deuterium content in effluent gases exceeded protium after 140min, but the hydrogen isotopes didn t elute from column 2 in 160 min. When the flux was 15SCCM, the hydrogen isotopes eluted slowly from column 1 after 90 min and the deuterium content in effluent gases exceeded protium after 110min, the hydrogen isotopes suddenly eluted from

column 2 after 140 min and the deuterium content exceeded protium. The protium content in the effluent gases was higher than deuterium at 25SCCM. FIG.4. Content Change of H D in the outflow with different fluxes of 0.6%H 2-0.6%D 2-98.8%Ar mixtures Fig.5 is the separation for the 1.63%H 2-0.97%D 2-97.4%Ar mixture at 298K and the fluxes were 5SCCM 10SCCM,respectively. The flux of 10SCCM has been described in section 3.1. At 5SCCM, the hydrogen isotopes eluted from column 1 after 110 min and the deuterium content exceeded protium, but the hydrogen isotopes didn t elute from column 2 in 160 min. FIG.5. Content Change of H D in the outflow with different fluxes of 1.63%H 2-0.97%D 2-97.4%Ar mixtures These figures show that the flux can also affect the H-D separation. The flux too big or too small was disadvantage to H-D separation. When the flux was too big, such as 25SCCM, the diffusion played an important role, the hydrogen isotopes became diffusion but not displacement, so the lighter molecules ran faster than the heavier; the protium content was higher than deuterium in the outflow and the separation efficiency was very bad. When the

flux was too small, such as 3 SCCM, it wastes too much time for the hydrogen isotopes eluting from the columns. As thus, the flux between 10~15SCCM was suitable for H-D separation when hydrogen isotope content was lower. 3.3. Hydrogen Isotope Content Dependence Fig.6 summarizes the separation efficiency at 298K, where the flux was 10SCCM and the raw gases were 1.63%H 2-0.97%D 2-97.4%Ar 3.37%H 2-2.03%D 2-94.6%Ar and 5.0%H 2-3.0%D 2-92.0%Ar, respectively. The raw gas mixture 1.63%H 2-0.97%D 2-97.4%Ar has been described in 3.1 section. When the raw gas mixture was 3.37%H 2-2.03%D 2-94.6%Ar, the hydrogen isotopes eluted from two columns after 80 min, 150 min, respectively. As 5.0%H 2-3.0%D 2-92.0%Ar mixture, the hydrogen isotopes eluted from two columns after 64 min, 140 min, respectively. These figures show that the deuterium content in outflow exceeded protium in two columns. The results also indicated that the hydrogen isotopes eluted from columns faster with the increase of hydrogen isotope content in raw gas and the time column 1 waste was half of column 2. FIG.6. Content Change of H D in the outflow with different hydrogen isotopes content in feed gases Fig.7 is the H-D separation factor of column 1 at 298K with different the raw gases. The separation factor was increased when the hydrogen isotope content increased. Since the pressure of system was keep at 0.1MPa during experiment,when the hydrogen isotope content was small, the hydrogen isotopes injected in the columns could not reach the plateau pressure of H 2 D 2. At 298K, the plateau pressures of palladium absorption H 2 D 2 are 2.096kPa, 10.520kPa, respectively and the plateau pressures of palladium desorption H 2 D 2 are 0.710kPa, 3.830kPa, respectively [9]. When the hydrogen isotope content is higher, the amount of hydrogen isotopes is more; the pressure of hydrogen isotope will be close to the plateau pressure, so the H-D separation factor will be higher. It is also observed that the separation factor of 3.37%H 2-2.03%D 2-94.6%Ar mixture was higher than that of 5.0%H 2-3.0%D 2-92.0%Ar mixture at first equilibrium. This result indicated that the hydrogen isotope pressure is closer to the plateau pressure of palladium absorption or desorption H 2 D 2, the separation efficiency will be better. Therefore the protium and deuterium content within 6at% of raw gas would be suitable in these experiments.

FIG.7. Separation factor of column 1 with different hydrogen isotopes content 4. Conclusions A new type of chromatography for separation of H 2 -D 2 -Ar mixture has been developed using 63g Pd/K as functional material with two columns. The H-D separation was studied at different operation conditions including columns temperatures, the flux and hydrogen isotope content in raw gas. The influence of these parameters on separation factor was evident. The results showed that the separation of protium-deuterium would be better when protium and deuterium content in raw gas within 6at%, with a flux of 10SCCM and a lower columns temperature. When column temperature was 273K, raw gas flux was 10SCCM and hydrogen isotopes occupied 2.6at% of raw gas, the average separation factor of H-D was 13.5. Deuterium fraction defined as D/(H+D) of the first column was 37.5at% in the feed gas and was concentrated to 89.01at% after separation. The separation and enrichment of this chromatographic system is very good. If make many columns (more than two) cascade in any way to separation hydrogen isotopes, it can separate large-scale hydrogen isotopes expediently and continually. The new chromatographic separation has a potential for separation and recovery of hydrogen isotopes out of the tritium extraction systems in breeding Test Blanket Modules. The separation of H 2 -D 2 -Ar mixture below 273.15K and more details of the separation mechanism are now being investigated. They will be reported in the near future. Acknowledgements The authors would like to thank Chang-An Chen for providing language help. Thanks to Yan Shi and Chang-An Chen for insightful discussion. References [1] YOSHIDA, H., KEVTON, O., KOONLE, J., et al., Status of the ITER Tritium Plant Design, Fusion Eng. and Design 39-40(1998)825-882. [2] IWAI, Y., YOSHIDA, H., YAMANIHI, T., et al., A design study of water detritation and hydrogen isotope separation systems for ITER, Fusion Eng. and Design 49-50(2000) 847-852. [3] WEICHSELGARTNER, H., FRISHCHMUTH, H., PERCHERMEIER, J., et al., Optimization of a large-scale Gas Chromatograph for separation tritium and DT from

other H isotopes, Nucl. Fusion 4(1983)687-692. [4] VOGD, R., Gas Chromatograph separation of hydrogen isotope on molecular sieves, Fusion Technol 28(1995)561-565. [5] DUCRET, D., BALLANGER, A., STEIMETZ, J., et al., Hydrogen isotopes separation by thermal cycling absorption process, Fusion Eng. and design 58-59(2001)417-421. [6] CLART, E.A., Material performance in prototype thermal cycling absorption process (TCAP) columns (U), WSRC-TR-92-552. [7] WATANABE, K., MATSUYAMA, M., KOBAYASHI, T., et al., Gas chromatographic separation of H2-D2 mixtures by Pd-Pt alloy near room temperature, J. Alloys and Compounds 257 (1997) 278-284. [8] WATANABE, K., MATSUYAMA, M., KOBAYASHI, T., et al., Hydrogen isotope separation by gas chromatography using Pd-Pt alloy, Fusion Eng. and Design 39/40 (1998) 1001-1008. [9] TANG, T., GUO, S.L., LU, G.D., et al., Thermodynamic Investigation of Interaction between Palladium with Hydrogen (H 2,D 2 ), Chinese journal of rare metals 28(2004) 308-312.