Pharmaceutical Impurity Identification and Profiling Using Agilent Q-TOF LC/MS Combined with Advanced MassHunter Data Processing Software

Similar documents
Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

MassHunter TOF/QTOF Users Meeting

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Application Note. Edgar Naegele. Abstract

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Computer-assisted analysis of complex natural product extracts

Application Note. Edgar Naegele. Abstract

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Accelerated Impurity Profiling Workflow for Bulk Drugs and Formulations using an Accurate Mass Workhorse

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

MassHunter Software Overview

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

ANALYTICAL REPORT 1 CUMYL-4CN-BINACA (C22H24N4O) 1-(4-cyanobutyl)-N-(1-methyl-1-phenylethyl)-1H-indazole-3-carboxamide

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Accurate Mass Analysis of Hydraulic Fracturing Waters

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

ANALYTICAL REPORT 1. 4-Me-TMP (C15H21NO2) Remark other NPS detected: none. sample contains some impurities (benzeneacetic acid + others)

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Acknowledgement: 4F-PBP (C14H18FNO) T: +386 (0) E: Vodovodna Ljubljana SLOVENIJA

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Measuring Drug-to-Antibody Ratio (DAR) for Antibody-Drug Conjugates (ADCs) with UHPLC/Q-TOF

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Routine MS Detection for USP Chromatographic Methods

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Agilent All Ions MS/MS

ANALYTICAL REPORT 1 1P-LSD (C23H29N3O2) N,N-diethyl-7-methyl-4-propanoyl-6,6a,8,9-tetrahydroindolo[4,3-fg]quinoline-9-

Quantitation of Cystine and Identification of Related Metabolites in White Blood Cells Using a High Resolution Accurate Mass LC/MS Approach

Modernizing the USP Monograph for Acetaminophen

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Making Sense of Differences in LCMS Data: Integrated Tools

Application Note. Abstract. Authors. Environmental

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

WADA Technical Document TD2003IDCR

Agilent ESI and APCI sources: for polar to non-polar compounds

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Die Nadel im Heuhaufen

Agilent G3212 GC-APCI Source

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Taking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline

770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Application Note. Authors. Abstract. Introduction. Environmental

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Transcription:

Pharmaceutical Impurity Identification and Profiling Using Agilent Q-TF LC/MS Combined with Advanced Massunter Data Processing Software Application Note Authors Siji Joseph Agilent Technologies LSCI Bangalore, India Yuqin Dai Agilent Technologies, Inc. Santa Clara, CA, USA Abstract This application note describes an effi cient software-assisted workfl ow for impurity identifi cation and profi ling of active pharmaceutical ingredients (API) using a high resolution accurate mass (RAM) quadrupole time-of-fl ight (Q-TF) LC/MS system. The workfl ow involves two steps: on-line LC-UV detection, followed by MS and auto MS/MS analysis; and identifi cation and structure elucidation of impurities using advanced Massunter Qualitative Analysis data processing algorithms such as Molecular Feature Extraction (MFE) and Molecular Formula Generation (MFG), and Molecular Structure Correlator (MSC) software. The Agilent 654 Ultra igh Defi nition Accurate Mass Q-TF LC/MS System provides sensitive MS and MS/MS analysis of trace-level impurities in drug substances with sub-ppm mass accuracy. The effective use of this workfl ow for impurity profi ling is demonstrated by the rapid identifi cation and structural elucidation of atenolol and eight European Pharmacopoeia (EP) specifi ed impurities, including genotoxic impurity D and two isomers of impurity F at the levels of. to.7 % relative to the atenolol UV detection area.

Introduction Impurity identification and profiling is critical to the assurance of patient safety and drug efficacy in a drug development and API manufacturing unit. Regulatory authorities have established clear and rigorous guidelines which dictate the identification of impurities at lower levels depending upon dosage. As per United States Food and Drug Administration (FDA) recommendations, any impurities having an area percentage >.5 of API should be reported. 1 Currently, various analytical techniques are available for the identification and quantification of drug impurities. owever, identification of trace levels of impurities is still challenging, as conventional analytical approaches often involve multiple instrument platforms and sample workup steps such as purifying/collecting a specific impurity by preparative LC followed by lyophilization, and performing NMR analysis, which can be time-consuming and laborious. The objective of this application note is to develop a streamlined workflow to effectively identify impurities using an Agilent LC UV/Q-TF MS system in combination with advanced data processing software. An example of identification and structure elucidation of eight atenolol impurities at levels of. to.7 % is demonstrated. Experimental Instrument The LC/MS system consisted of an Agilent 654 UD Q-TF with a Jet Stream source, and an Agilent 1 Series Binary LC System, which consists of following modules: Agilent 1 Series degasser (p/n G1379B), Agilent 1 Series Binary Pump (p/n G131B), Agilent 1 Series igh-performance Autosampler (p/n G1367D), Agilent 1 Series Thermostatted Column Compartment PLC separation If the method is MS compatible LC/MS analysis using Agilent 654 Q-TF with full MS scan followed by auto MS/MS Find and identify impurities by MFE and MFG algorithms based on the accurate mass MS and MS/MS data MSC facilitates the structure elucidation of the impurities 1 3 (p/n G1316B), and an Agilent 19 Infinity Diode Array Detector (G41A) with Max-Light flow cell, (4. μl volume, 6-mm path length) (G41 A). The software included an Agilent Massunter Workstation (version B.4.) for data acquisition, Massunter Qualitative Analysis software (B.4.) for data analysis, and Massunter MSC software (version B.5.) to facilitate the elucidation of impurity structures. If the method is non MS compatible Result example m/z 68.1543 C 14 1 N 4 Develop equivalent MS compatible LC method N Figure 1. Software assisted workflow for impurity identification and profiling of pharmaceuticals using an Agilent 654 UD Q-TF LC/MS, Massunter Qualitative Analysis, and MSC software. C3 C3 Figure 1 shows a novel workflow for impurity identification and profiling. This workflow has been streamlined to provide high-confidence, accurate identification and faster structure elucidation compared to conventional impurity profiling, which requires multiple platforms and spreads analysis over multiple days.

Reagents and materials LC/MS grade methanol and formic acid were purchased from Fluka (Germany). ighly purified water from a Milli Q system (Millipore Elix 1 model, USA) was used for mobile phase preparation. All other reagents used to execute the pharmacopeia PLC method for atenolol were purchased from Aldrich (India). Standards of atenolol API and eight impurities (A to ) were purchased from LGC Promochem (Germany). The structure of atenolol and eight impurities are shown in Figure and molecular details are listed in Table 1. N N N Atenolol Impurity B N C 3 Cl C 3 N Impurity A N N LC/MS conditions The LC/MS conditions were optimized and are summarized in Tables and 3. Impurity D N C 3 N Impurity C Impurity E N N Impurity F N C 3 N C 3 C 3 NC C 3 Impurity G Impurity Figure. Molecular structures of atenolol and eight impurities as per EP (6.). Table 1. Molecular details of atenolol and eight impurities. Name Molecular formula Molecular weight (M+) + Atenolol C 14 3 66.3361 67.173 Impurity A C 8 9 151.166 15.76 Impurity B C 11 15 N 4 5.411 6.174 Impurity C C 11 13 N 3 7.58 8.968 Impurity D C 11 14 ClN 3 43.6868 44.735 Impurity E C 19 5 358.3884 359.161 Impurity F C 5 35 N 3 6 473.5619 474.599 Impurity G C 14 1 N 4 67.38 68.1543 Impurity C 14 48.38 49.1598 Note: The (M+) + values were calculated using Massunter Mass Calculator 3

Table. LC conditions. LC (MS compatible) conditions Column Agilent Poroshell 1 EC-C18, 3. 15 mm,.7 µm (p/n 693975-3) LC (EP) conditions Agilent ZRBAX DS 4.6 15 mm, 5 µm (p/n 88395-7) Flow rate.4 ml/min 1 ml/min Mobile phase A.1% formic acid in water 1 g of sodium octane sulfonate +.4 g of tetrabutylammonium hydrogen sulphate in :18:8 of tetrahydrofuran:methanol:buffer. Buffer 3.4 g /L solution of K P 4, adjust the p to 3. with 3 P 4 Mobile phase B.1 % formic acid in methanol Not applicable Detection 6 nm 6 nm Injection volume µl 1 µl Needle wash Activated for 5 seconds using methanol Activated for 6 seconds using methanol Pump mode Gradient Isocratic Time % B 1 % A from to 3 minutes 11 5 3 6 3 36 11 Post run 5 minutes Not applicable Column temperature 43 C Not maintained Table 3. Agilent 654 UD Q-TF parameters. Q-TF MS and auto MS/MS conditions Ion source AJS ESI Acquisition mode Gz, Ext dynamic range Ion polarity + ve mode Data storage Both centroid and profile Drying gas temperature 35 C Drying gas 1 L/min Nebulizer 45 psig Sheath gas temperature 4 C Sheath gas flow 1 L/min VCap 4, V Nozzle voltage 5 V Fragmentor 15 V Skimmer 75 V CT 1RF Vpp 75 V Acquisition MS followed by auto MS/MS MS acquisition rate 5 spectra/s MS/MS acquisition rate 4 spectra/s Isolation width Medium (~4 m/z) Collision energy, use formula Slope 4, offset 1 4

Sample preparation and analysis Atenolol was spiked with the eight EP specified impurities. The concentration of atenolol in the spiked sample is approximately, ppm and the percentages of impurities in atenolol range from. to.7 %. The spiked sample was initially analyzed using the EP method and the percentage area of each impurity was measured. Since the pharmacopoeia PLC method involves nonvolatile buffers which are not compatible with mass spectrometry (MS) analysis, an MS compatible LC method was developed using water/methanol containing.1 % formic acid as mobile phase. The sample was analyzed by on-line UV detection followed by full MS and auto MS/MS analysis with the 654 UD Q-TF LC/MS System. Results and Discussion LC-UV and LC-UV/654 UD Q-TF MS analysis The chromatographic separation of a spiked atenolol sample, using the EP method, is shown in Figure 3. Figure 4 shows separation of the same sample using the MS-compatible LC method where all eight impurities are well separated. Although the elution order of each impurity was found to be different in the LC/MS method from the EP method, percentage areas of all impurities from both methods were comparable. Table 4 summarizes the observed area percentages of atenolol and impurities from the LC/MS method. mau 3 1 DAD1 A, Sig = 6, Atenolol and impurities B DMS 1.89.411 A C 4.143 5.8 Atenolol E D 8.1 8.657 Isomers F 1.135 1.673 5 1 15 5 Time (min) Figure 3. Chromatographic separation of atenolol and eight impurities using the EP method. mau 5 4 3 1-1 LC Chromatogram DAD1 A, Sig = 6 Atenolol and impurities A 4.71 5.88 Atenolol B 6.486 5 1 15 Time (min) 11.619 G 13.18 G 19.447 D C F1 F 14.95 15.96 16.493 1.8 4.316 5 Figure 4. Chromatographic separation of atenolol and eight impurities using an in-house developed MS compatible method. Table 4. Percentage areas based on the UV signals. Peak no. Time Area% Name 1 4.7.7 A 5.8 99.61 Atenolol API 3 6.48.7 B 4 11.61.4 5 13.18.4 G 6 14.9.4 C 7 15.96.3 F1 8 16.49.3 F 9 1.8. D 1 7.3.5 E E 7.31 5

Figure 5 shows the Total Ion Chromatogram (TIC). The LC eluants from to 3.5 minutes and from 5.5 minutes to 6. minutes were diverted to the waste. Data analysis using Agilent Massunter Qualitative Analysis software Data analysis was performed using the MFE and MFG algorithms of the Massunter Qualitative Analysis software. The MFE algorithm was able to automatically locate all sample components in an untargeted fashion and to extract all relevant spectral and chromatographic information for the trace impurity entities. The MFG algorithm takes full advantage of the mass accuracy of the data. After user input (allowed elements, even/odd electrons, and charge carrier) based on the knowledge of sample composition, the MFG uses information at the MS level (masses of main isotope, isotope abundances, and isotope spacing) and the MS/MS level (masses of MS/MS fragment ions and neutral losses if available), for the calculations to generate empirical formulas. Using all this accurate mass information results in a smaller and more relevant list of candidate molecular formulas for each entity and ranks them according to the relative probabilities (maximum score is 1 %). 1 6 +ESI TIC Scan Frag = 15. V API and impurities 4 Main Main G stream stream 3 to waste to waste Counts 1 A B Atenolol C Figure 6 shows the measured isotope pattern versus a theoretical one of impurity B (the latter shown in rectangles), and MFG scores and mass accuracy for each isotope, demonstrating the high isotopic fidelity with match scores greater than 99 % for masses, isotope abundance, and isotope spacing. These results provide reliable formula generation and impurity identification with high confidence. 1 3 4 5 6 7 8 9 1 11 1 13 14 15 16 17 18 19 1 3 4 5 6 7 8 9 3 Acquisition time (min) Figure 5. Total ion Chromatogram (TIC) using on-line LC/UV detection and 654 UD Q-TF MS analysis. F1 F D E A) 1 5 1 5 6.173 (M+) + 1.5 6.173 (M+) + 48.893 (M+Na) + Counts 1 1.5 7.115 (M+) + 8.117 (M+) + 6. 6.5 7. 7.5 8. B) 4 6 8 3 3 34 36 38 4 4 44 46 48 5 5 54 56 58 6 6 64 66 68 7 7 Mass-to-charge (m/z) Figure 6. (A) shows the MS spectrum of impurity B, and (B) shows the MFE/MFG results for impurity B. 6

Table 5 summarizes the results from MFE and MFG algorithms for all eight impurities and atenolol. The compound numbers are labeled based on the retention time (RT) in the order the impurities are eluted. Two hits were observed for atenolol, representing the leftover beginning and end of the atenolol main peak, which was diverted to the waste. Isomers of Impurity F were chromatographically separated and are listed as impurity F1 and F. As illustrated in Table 5, the observed (M+) + values correlate very well with the theoretical (M+) +, with mass errors of less than 1 ppm for all impurities identified. Agilent Massunter Molecular Structure Correlator (MSC) software MSC correlates the accurate mass of MS/MS fragment ions of a compound of interest with one or more proposed molecular structures for that compound. MSC accomplishes this by correlating each observed fragment ion to the proposed structure using a systematic bond-breaking approach. An overall correlation score is calculated from individual scores for each fragment ion signal. For each fragment ion, one or multiple substructure candidates may be suggested (Figure 8) and a penalty is assigned based on the number and type of bonds needed to be cleaved to generate that substructure, as well as the number of hydrogen atoms that need to be added or subtracted to explain the observed fragment ion mass. For example, breaking two bonds, or a double bond or even an aromatic ring carries a higher penalty than just breaking one single bond. Two other factors impacting the overall correlation score are the mass accuracy of the observed fragment ions and the overall percentage of fragment ion intensity that can be explained with substructures. 3 MSC software can be used to confirm a user-proposed structure for a compound and also aid in the identification of true unknowns. Table 5. Molecular formulas obtained from MFE/ MFG results. Cpd Formula from EP Formula from MFG Score (MFG) Theoretical (M+) + Experimental (M+) + Mass error (ppm) 1 Imp A C 8 9 C 8 9 99.78 15.76 15.76. Atenolol C 14 3 C 14 3 98.68 67.173 67.174.37 3 Atenolol C 14 3 C 14 3 99.48 67.173 67.175.75 4 Imp B C 11 15 N 4 C 11 15 N 4 99.4 6.174 6.173.44 5 Imp C 14 C 14 99.79 49.1598 49.1599.4 6 Imp G C 14 1 N 4 C 14 1 N 4 99.39 68.1543 68.1545.75 7 Imp C C 11 13 N 3 C 11 13 N 3 99.1 8.968 8.966.96 8 Imp F1 C 5 35 N 3 6 C 5 35 N 3 6 99.17 474.599 474.61.4 9 Imp F C 5 35 N 3 6 C 5 35 N 3 6 98.35 474.599 474.599. 1 Imp D C 11 14 ClN 3 C 11 14 ClN 3 98.3 44.735 44.736.41 11 Imp E C 19 5 C 19 5 98.36 359.161 359.164.84 7

The utility of MSC for structure elucidation of impurity E and F are demonstrated in Figures 7 and 8. Figure 7 shows how the MSC software can aid in identification of an unknown impurity. The accurate masses of the precursor ion and fragment ions of impurity F were used to calculate the most probably molecular formula, which then was searched against the ChemSpider database to retrieve all possible structures. Multiple candidate structures were returned with their calculated correlation scores. The primary MSC proposed structure with the highest correlation score of 99.14 % matches exactly to that of impurity F. The overall MFG score for the selected precursor ion, the rank of the MSC proposed structure and the structure correlation score for impurity F are highlighted in red circles. Figure 8 illustrates how the MSC software can be used to confirm a user-proposed structure. The MS/MS spectral data of impurity E was uploaded to the MSC software, and the structure of Impurity E was imported as a.mol file. As shown in the Figure 9, the proposed structure correlates very well with the MS/MS spectrum of Impurity E with a correlation score of 97.35% (highlighted in red circle). Figure 7. Screen shot of MSC results for Identification of an unknown impurity (Impurity F). List of possible molecular formulas for the precursor ion for Impurity F (A), MFG results of product ions for a selected precursor candidate in panel A (B), Candidate structures for the parent compound (C), Fragment ions for the candidate structure selected in panel C (D), and Substructure assignments for a selected fragment ion in panel D (E). 8

Figure 8. Screen shot of MSC results for confirmation of a proposed structure (Impurity E). Using these approaches, the structures of all the remaining entities/impurities were elucidated. The molecular structures of the atenolol impurities obtained using MSC software correlate with the validated structures in Pharmacopeia (Figure ). Table 6 summarizes the results from the MSC. Table 6. MSC results for atenolol API and its impurities. No. Entity Precursor dm (ppm) Compound correlation/ compatibility score (%) % Weight* 1 Atenolol API -1.1 94.97 1 Impurity A -.6 96. 99.4 3 Impurity B.4 94.93 1 4 Impurity C.6 9.18 99.8 5 Impurity D -.1 9.83 98.7 6 Impurity E -.7 97.35 1 7 Impurity F -.5 99.14 1 8 Impurity G -.6 96. 1 9 Impurity -.6 97.73 1 *% of total ion intensity explained, weighted by the mass of the fragment ion. (Explanation of higher mass fragment ions represent higher evidence.) 9

Figure 9 shows the MS/MS spectra of atenolol and impurity G. By comparing the m/z values of the precursor and fragment ions of both atenolol and impurity G, as well as the proposed substructures by MSC software for each compound, the degradation site of the impurity G can be easily determined. N N N 1 3 6 A N N Counts Counts 5 4 3 1 1 3 5 4 3 1 B C 3 56.499 N 74.63 98.968 N 116.168 145.647 19.856 N 3 C N N 3 C N N N 56.5 145.649 3C 7.81 191.698 68.1543 116.17 98.968 165.533 6.16 178.856 8.96 N N C 3 67.173 N 3 4 5 6 7 8 9 1 11 1 13 14 15 16 17 18 19 1 3 4 5 6 7 8 Mass-to-charge (m/z) Figure 9. Structure elucidation of impurity G assisted by MSC software. MS/MS spectra of atenolol (A) and Impurity G (B). 1

Conclusion An efficient workflow was developed for identification and profiling of trace levels of pharmaceutical impurities using Q-TF technology combined with advanced data processing software. The wide in-spectrum dynamic range of the Agilent 654 UD Q-TF allowed identification of all eight trace level impurities from an atenolol API sample. A high MFG score of greater than 98. and low mass error of less than 1 ppm were achieved, leading to highly confident impurity identification. MFE, MFG, and MSC proved to be essential tools for the fast and efficient identification and structure determination of impurities. Furthermore, MSC can be efficiently used to narrow down the number of structural possibilities of unknown impurities, providing insight into the substructures that might exist in an unknown molecule or to suggest the class of molecules. References 1. Guidance for Industry Q3A Impurities in New Drug Substances, June 8, Revision.. European pharmacopoeia 6., (8), Volume, page 18-19(4). 3. Agilent Massunter Molecular Structure Correlator (MSC) Software Quick Start Guide, Agilent Publication G3335-916. 11

www.agilent.com/chem/qtf This information is subject to change without notice. Agilent Technologies, Inc., 1 Published in the USA, December 14, 1 5991-1375EN