Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO Nano fluid

Similar documents
Experimental Investigation of Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO/water Nano fluid

SSRG International Journal of Mechanical Engineering ( SSRG IJME ) Volume 2 Issue 5 May 2015

Numerical investigation of heat transfer enhancement in a pipe heat exchanger by adding nano particle and twisted tape

International Journal of Advanced Engineering Research and Studies E-ISSN

Analysis of Heat Transfer in Pipe with Twisted Tape Inserts

Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced Convection

Research Article. Kaustubh G. Kulkarni * and Mandar M. Lele. Abstract

Study of Compound Heat Transfer Enhancement of Horizontal Liquid-Solid Fluidized Bed Heat Exchanger with a Kenics Static Mixer

Department of Mechanical Engineering, VTU, Basveshwar Engineering college, Bagalkot, Karnataka, India

Experimental Investigation of Heat Transfer Enhancement by Using Clockwise and Counter -clockwise Corrugated Twisted Tape Inserts

Enhancement of Heat Transfer in Heat Exchanger using Punched and V-cut Twisted Tape Inserts

Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib

Performance analysis of V-jagged twisted tape insert for heat transfer in a circular tube

Sarbendu Roy, Manvendra Tiwari and Sujoy Kumar Saha 1. Mechanical Engineering Department, IIEST, Shibpur, Howrah , West Bengal, INDIA

International Journal of Innovative Research in Science, Engineering and Technology

Investigation of Heat Transfer Enhancement in Laminar Flow through Circular Tube Combined Wire Coil and Wavy Strip with Central Clearance

Heat Transfer Enhancement Using a Rotating Twisted Tape Insert

International Communications in Heat and Mass Transfer

Comparative Analysis of Heat Transfer and Friction Characteristics in a Corrugated Tube

Experimental studies on hydrodynamic behaviour of flow through a tube with TRIANGULAR WAVY TAPES. Bachelor of Technology in Chemical Engineering

Experimental Analysis of Heat Transfer Enhancement through Pipe using Baffles

Numerical Heat Transfer Study of Turbulent Square Duct Flow through W-Type Turbulators

HEAT TRANSFER ENHANCEMENT IN HEAT EXCHANGER USING TANGENTIAL INJECTOR TYPE SWIRL GENERATOR

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

CHAPTER 3 SHELL AND TUBE HEAT EXCHANGER

AUGMENTATION OF HEAT TRANSFER USING COILED POROUS TWISTED TAPE INSERT

Experimental and Numerical Analysis of Turbulent Flow Heat Transfer Enhancement in a Horizontal Circular Tube Using Mesh Inserts

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Investigation of Heat Transfer on Smooth and Enhanced Tube in Heat Exchanger

Experimental Study of Heat Transfer Enhancement through a Tube with Wire-Coil Inserts at Low Turbulent Reynolds Number

Convective Heat Transfer and Thermal Performance in a Circular Tube Heat Exchanger Inserted with U-Shaped Baffle

Computational Analysis of Heat Transfer Enhancement in a Circular Tube Fitted with Different Inserts

EXPERIMENTAL STUDIES ON HEAT TRANSFER AUGMENATATION USING GALVANISED IRON WIRE INSERT WITH AND WITHOUT BAFFLES

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

A study on the heat transfer enhancement for air flow through a duct with various rib inserts (Review)

Effect of V-Shape Twisted Jaw Turbulators on Thermal Performance of Tube heat exchanger: An Experimental Study

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

Mechanism of Heat Transfer Enhancement in the Core Flow of a Tube and Its Numerical Simulation

Heat Transfer Analysis of Helical Strip Insert with Regularly Spaced Cut Sections Placed Inside a Circular Pipe

International Communications in Heat and Mass Transfer

Chapter 3 NATURAL CONVECTION

REFERENCES. 5. ANSI/ASME, Measurement uncertainty, PTC 19, Part I, , 1986.

Sami D. Salman, 1,2 Abdul Amir H. Kadhum, 1 Mohd S. Takriff, 1 and Abu Bakar Mohamad Introduction

Heat transfer characteristics and friction of turbulent swirling air flow through abrupt expansion

International Journal of Engineering, Business and Enterprise Applications (IJEBEA)

HEAT TRANSFER ENHANCEMENT WITH ELLIPTICAL TUBE UNDER TURBULENT FLOW TiO 2 -WATER NANOFLUID

Amir Houshmand, Ahmad Sedaghat, Kia Golmohamadi and Mohamadreza Salimpour

The Effect of Solid and Perforated Pin Fin on the Heat Transfer Performance of Finned Tube Heat Exchanger

EXPERIMENTAL STUDIES ON HEAT TRANSFER AUGMENTATION USING TRIANGULAR WAVY TAPE (TWT) AS INSERTS FOR TUBE SIDE FLOW OF LIQUIDS

Heat Transfer Enhancement of Shell and Tube Heat Exchanger Using Conical Tapes.

PLATE TYPE HEAT EXCHANGER. To determine the overall heat transfer coefficient in a plate type heat exchanger at different hot fluid flow rate

Flow and Heat Transfer Profiles in a Square Channel with 45 V-Downstream Orifices

Principles of Convection

Experimental investigation of heat transfer augmentation in triangular duct with rectangular wing

طراحی مبدل های حرارتی مهدي کریمی ترم بهار HEAT TRANSFER CALCULATIONS

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

Experimental Heat transfer study of Turbulent Square duct flow through V type turbulators

AUGMENTATION OF RIBS TURBULATORS HEIGHT ON THE HYDROTHERMAL PERFORMANCE OF DOUBLE PIPE HEAT EXCHANGER

Heat Transfer Enhancement in Fe3O4-water Nanofluid through a Finned Tube Counter Flow Heat Exchanger

Experimentation and Performance Evaluation of Heat Exchanger Using Z-Ribs

Prediction of the Heat Transfer in an Air Cooler Equipped with Classic Twisted Tape Inserts using Artificial Neural Network (ANN)

Australian Journal of Basic and Applied Sciences. Heat transfer enhancement of laminar flow in a circular tube using Swirl / vortex generator

AASCIT Journal of Nanoscience 2015; 1(4): Published online September 10, 2015 (

Heat Transfer Co-efficient and Effectiveness for Water Using Spiral Coil Heat Exchanger: A Comprehensive Study

Enhancement in the Performance of Heat Exchanger by Inserting Twisted Tape Turbulators

Effect of Twisted-Tape Turbulators and Nanofluid on Heat Transfer

Numerical Investigation of Heat Transfer Enhancement and Pressure Drop of a Double Tube Heat Exchanger with Rectangular Fins in the Annulus Side

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

FLOW AND HEAT TRANSFER ANALYSIS OF VARIOUS RIBS FOR FORCED CONVECTION HEAT TRANSFER

PERFORMANCE ANALYSIS OF CORRUGATED PLATE HEAT EXCHANGER WITH WATER AS WORKING FLUID

Forced Convection: Inside Pipe HANNA ILYANI ZULHAIMI

ENHANCEMENT OF HEAT TRANSFER FOR AIR FLOW THROUGH A DUCT WITH VARIOUS RIBS

Heat Transfer Investigation in a Circular Tube Fabricated from Nano-composite Materials Under a Constant Heat Flux

CFD Investigation of Heat Transfer and Flow Patterns in Tube Side Laminar Flow and the Potential for Enhancement

EFFECT OF TWISTED TAPE INSERTS IN DOUBLE PIPE HEAT EXCHANGER USING AL2O3/WATER NANO FLUIDS

ENERGY PERFORMANCE IMPROVEMENT, FLOW BEHAVIOR AND HEAT TRANSFER INVESTIGATION IN A CIRCULAR TUBE WITH V-DOWNSTREAM DISCRETE BAFFLES

THE EFFECT OF TWISTED TAPE WIDTH ON HEAT TRANSFER AND PRESSURE DROP FOR FULLY DEVELOPED LAMINAR FLOW

Heat transfer coefficient of near boiling single phase flow with propane in horizontal circular micro channel

Experimental Investigation of Heat Transfer from a Flat and Surface Indented Plate Impinged with Cold Air Jet- Using Circular Nozzle

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Numerical Investigation on Turbulent Forced Convection in Heating Channel Inserted with Discrete V-Shaped Baffles

Thermo-Hydraulic performance of Internal finned tube Automobile Radiator

EFFECT OF STAGGERED RIB LENGTH ON PERFORMANCE OF SOLAR AIR HEATER USING V-RIB WITH SYMMETRICAL GAP AND STAGGERED RIB

Convection Heat Transfer. Introduction

PERFORMANCE ANALYSIS OF PARABOLIC TROUGH COLLECTOR TUBE WITH INTERNAL INTERMITTENT FINS

Fluid Flow and Heat Transfer Characteristics in Helical Tubes Cooperating with Spiral Corrugation

Cfd Simulation and Experimentalverification of Air Flow through Heated Pipe

Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an Inclined Square Duct

Transactions on Engineering Sciences vol 18, 1998 WIT Press, ISSN

Analysis of Heat Transfer Enhancement in Spiral Plate Heat Exchanger

ME 331 Homework Assignment #6

Enhancement in heat transfer coefficient of water by using nano-fluids for corrugated plate heat exchanger

CFD Analysis and Optimization of Heat Transfer in Double Pipe Heat Exchanger with Helical-Tap Inserts at Annulus of Inner Pipe

Performance evaluation of heat transfer enhancement for internal flow based on exergy analysis. S.A. Abdel-Moneim and R.K. Ali*

CFD Analysis on Flow Through Plate Fin Heat Exchangers with Perforations

COMPUTATIONAL FLUID DYNAMICS ANALYSIS ON HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF A TURBULENT FLOW FOR INTERNALLY GROOVED TUBES

HEAT TRANSFER ENHANCEMENT BY USING NANOFLUID JET IMPINGEMENT

Numerical Investigation on The Convective Heat Transfer Enhancement in Coiled Tubes

Transcription:

Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO Nano fluid 1 Krishna S. Borate, 2 A.V. Gawandare, 3 P.M. Khanwalkar 1,2,3 Department of Mechanical Engineering, Sinhgad College of Engineering, Pune, India Email: 1 krishnaborate@sinhgad.edu, 3 pmkhanwalkar.scoe@sinhgad.edu Abstract The present experimental work is carried out with copper twisted tape inserts 3mm thick with5.2, 4.2 twist ratios and nano fluid. The inserts when placed in the path of the flow of the fluid, create a high degree of turbulence resulting in an increase in the heat transfer rate and the pressure drop. Apart from the basic reason of improvement in thermal conductivity in nano fluids, the suspension of nano particles alters the flow behaviour in general. The work includes the determination of friction factor and heat transfer coefficient for various twisted tape inserts with varying twists and CuO nano fluid. The Reynolds number is varied from 5000 to 16000. Correlations for Nusselt number and friction factor are developed for the twisted tape inserts from the obtained results. The results of varying twists in square jagged tape with different pitches and CuO nano fluid have been compared with the values for the smooth tube. The 3mm thick with 4.2 twist copper insert and nano fluid shows increase in Nusselt number values by 81% however there is increase in friction factor by only 21.5% as compared to the smooth tube values. Index Terms Enhancement efficiency, heat transfer, square jagged twisted tapes, turbulent; swirling, pressure drop, nano fluid. I. INTRODUCTION Heat exchangers are widely used in various industrial processes for heating and cooling applications such as air conditioning and refrigeration systems, heat recovery processes food and dairy processes, chemical process plants etc. The major challenge in designing a heat exchanger is to make the equipment compact and achieve a high heat transfer rate using minimum pumping power. Techniques for heat transfer augmentation are relevant to several engineering applications. In recent years, the high cost of energy and material has resulted in an increased effort aimed at producing more efficient heat exchange equipment. Furthermore, sometimes there is a need for miniaturization of a heat exchanger in specific applications, such as space application, through an augmentation of heat transfer. For example, a heat exchanger for an ocean thermal energy conversion (OTEC) plant requires a heat transfer surface area of the order of 10000 m 2 /MW [1]. Therefore, an increase in the efficiency of the heat exchanger through an augmentation technique may result in a considerable saving in the material cost. Furthermore, as a heat exchanger becomes older, the resistance to heat transfer increases owing to fouling or scaling. These problems are more common for heat exchangers used in marine applications and in chemical industries. In some specific applications, such as heat exchangers dealing with fluids of low thermal conductivity (gases and oils) and desalination plants, there is a need to increase the heat transfer rate. The heat transfer rate can be improved by introducing a disturbance in the fluid flow thereby breaking the viscous and thermal boundary layer. However, in the process pumping power may increase significantly and ultimately the pumping cost becomes high. Therefore, to achieve a desired heat transfer rate in an existing heat exchanger at an economic pumping power, several techniques have been proposed in recent years and are discussed under the classification section. II. HEAT TRANSFER ENHANCEMENT USING VARIOUS SQUARE JAGGED TWISTED TAPE A. Present experimental work The experimental study on passive heat transfer augmentation using square jagged copper twisted tape inserts for no. of twists with nano fluid were carried on in a single phase flow heat exchanger having the specifications as listed below: Figure 1 Experimental setup for forced convection 31

B. Experimental Set up Experimental set up consists of test section having tube in tube heat exchanger. Inside tube is of Copper and outside tube is of Stainless Steel. Four thermocouples are connected to the test section, two at the inlet and two at the outlet of hot and cold water respectively. Two rotameters are connected at inlet of cold and hot water to measure the flow rates. Also control valves and bypass valves are provided at inlet of both the rotameters. Two centrifugal pumps are used to circulate the cold and hot water. Two tanks are used for storing the hot water and cold water. Electric heater is attached to the hot water tank having capacity of 1500watt. To measure the pressure difference between inlet and outlet of test section of hot fluid inverted U-tube manometer is used. Different twisted tape inserts are used along with CuO nano fluid. 13. Fill the hot water tank with prepared CuO nano fluid. 14. Start nano fluid pump. 15. Repeat step nos. 7,8,9,10. 16. Switch off pumps, water heater and temperature display. D. Specifications of inserts Material: Copper i. Width of twisted tape = 12mm ii. Twist ratio = 5.2, 4.2. iii. Length of insert = 100cm iv. Thickness of inserts = 3mm E. Specifications of CuO Nano fluid i. Average particle size = <80nm ii. Purity = >99% iii. Content of CuO = >99% iv. Appearance = Black powder v. Concentraion = 0.4% Figure 2 Schematic diagram of forced convection setup C. Experimental Procedure 1. Refer to the Fig 1 and make all theccable connection carefully. 2. Switch ON the water heater wait until water temperature reaches 80. 3. Switch on temperature display. 4. Start cold water pump. 5. Adjust flow rate of cold water at 100 LPH. 6. Start hot water pump. 7. Adjust flow rate of hot water at 100 LPH and keep it constant. 8. The temperatures will keep on rising continuously. When steady state is reached, note all the temperatures (T1 to T4). 9. Now Adjust flow rate of hot water at 200 LPH. 10. The temperatures will keep on rising continuously. When steady state is reached, note all the temperatures (T1 to T4). 11. Repeat step 9 and 10 for hot water flow rates at 300,400,500,600,700,800 and 900 LPH. 12. Now use the nano fluid with inserts. Figure 3 Photographic view of CuO nano particles Figure 4 Copper square jagged twisted tape (y = 5.2) (englarged view) 32

Figure 5 Copper square jagged twisted tape (y = 4.2) (englarged view) Methodology And Sample Properties of Water a) Properties of hot water III. CALCULATIONS calculated at mean bulk temperature T bh = (T h1 + T h2 ) b) Properties of cold water T bc = (T c1 +T c2 )/2 2) Heat given by hot water Q h = m h C ph (T h1 -T h2 ) 3) Heat given by cold water Q c = m c C pc (T c2 -T c1 ) 4) Average heat transfer Q avg. = (Q h +Q c )/2 5) Overall heat transfer coefficient Q avg. = UA s T m a) Surface area of tube A s = p d i L b) Logarithmic mean temperature difference T m = ( T 1 - T 2 )/ln( T 1 / T 2 ) T 1 = T h1 T c2 T 2 = T h2 T c1 6) Nusselt Number of cold water flowing through the annular space. Nu o = 0.023(Re o ) 0.8 (Pr) 0.3 Re o = UoDh/ D h = D i - d o Continuity equation m c = A o U o 7) Heat transfer coefficient of cold water flowing through the annular space. Nu o =h o D h /k h o =Nu o k/d h 8) Heat transfer coefficient of hot water flowing through the tube. 1/U = 1/h i + 1/h o h i = 1/(1/U-1/h o ) Experimental Nusselt Number of hot water flowing through the tube. Nu i = h i d i /k 10) Theoretical Nusselt Number of hot water flowing through the tube (Dittus Boelter equation). Nu o = 0.023(Re o ) 0.8 (Pr) 0.3 11) Experimental Friction Factor a) p = gh b) p = fl U i 2 /2d i f = 2gd i h/lu i 2 12) Theoretical Friction Factor f = 0.0055(1+(50+(10 6 /Re i )) 0.33 ) 13) Performance evaluation criteria Nu 33 PEC Nu P1 f 3 f P IV. RESULTS AND DISCUSSION A. Validation Of The Experimental Programme The accuracy with which the friction factor and Nusselt number could be evaluated experimentally with the use of present experimental rig was determined by conducting preliminary experiments with plain tube without insert, and results compared with standard empirical relationships and previous research work for laminar flow. The purpose was to check the reliability of the apparatus. a. Heat transfer results for smooth tube : Figure 6 shows the relation between Nusselt number v/s Reynolds number. The curve shows that Nusselt number is a function of Reynolds number. The values are in close agreement with the Dittus- Boelter equation with a maximum variation of 20 %

Figure 6 Nusselt number v/s Reynolds b. Friction factor results for smooth tube: Figure 7 shows the relation friction factor v/s Reynolds number for turbulent flow in the tube without twisted tape insert, that is smooth tube flow conditions. This proves that the experimental test rig is validated and further experimentation can be carried out. Figure 8 Nussultnumber v/s Reynolds number plot for Y=5.2, 4.2 & nano fluid Figure 9 shows the relation between friction factor and Reynolds number for plain tube and tube with various inserts, the Figure concludes that the friction is minimum when the twisted tape is not inserted. Further, with the increase in twist, i.e. with the decrease in twist ratio, the friction factor goes on increasing for a particular Reynolds number. Perforated tapes show lesser friction factor compared with plain twisted tapes. Figure 7 Friction factor v/s Reynolds number B. Comparison Of Plain Tube and Tubes With Various Twisted Tapes Figure 8 shows the relation between Nussult number and Reynolds number for plain tube and tube with various inserts, the Figure concludes that the Nusselt number is function of Reynolds number. Nusselt number increases with increase in Reynolds number. Hence, convective heat transfer rate is more with higher Reynolds number. Further, it can be concluded that, twisted tapes with tighter twist (with lesser twist ratio) give increased Nusselt number for a particular Reynolds number. Heat transfer rate is better with twisted tapes of lower twist ratio. Perforated tapes shown greater Nusselt number compared with plain twisted tapes. Figure 9 Friction factor v/s Reynolds number plot for Y=5.2, 4.2 The curves are very steep for lesser values of Reynolds number. This is due to the fact that, for lower values of Reynolds number, the viscous force dominates the inertia force. For lower Reynolds number, less than 550, the curves are more leaning and the friction factor is comparatively high. V. CONCLUSION Experimental investigation of heat transfer and friction factor characteristicsof circular tube fitted with full-length square jagged twisted tape inserts of different twist ratio has been presented. Calculations and curve fitting is done and correlations are obtained. The results showed that there was an appreciable enhancement in heat transfer and that the heat transfer is more with lesser twist ratio. 34

Maximum increase in Nu for nano fluid was found to be 31 % Maximum increase in Nu for twisted tape with y = 5.2 and nano fluid was found to be 90 % Maximum increase in Nu for twisted tape with y = 4.2 and nano fluid was found to be 151 % Friction factor is increased by 30 % with nano fluid Friction factor is increased by 50 % with y=5.2 & nano fluid Friction factor is increased by 89 % with y=4.2 and nano fluid It is concluded that heat transfer increase by151% while frction factor increases by 89% so with less pumping power more heat transfer can achieved REFERENCES [1] Hsieh and Huang, Experimental studies for heat transfer and pressure drop of laminar flowin horizontal tubes with/without longitudinal inserts,2000. [2] Sarma, Heat transfer coefficients with twisted tape inserts, 2003. [3] Hsieh, Experimental studies on heat transfer and flow characteristics for turbulent flow of air in a horizontal circular tube with strip type insert, 2003. [4] PairsonNaphon, Effect of coil-wire insert on heat transfer enhancement and pressure drop of the horizontal concentric tube, International Communications in Heat and Mass Transfer 33 (2006) 753 763,2006. [5] Smith Eiamsa-ard, Pongjet Promvonge, Heat transfer characteristics in a tube fitted with helical screw-tape with/without corerod inserts, International Communications in Heat and Mass Transfer 34 (2007) 176 185. [6] Sibel Gunes, Veysel Ozceyhan, Orhan Buyukalaca, The experimental investigation of heat transfer and pressure drop in a tube with coiled wire inserts placed separately from the tube wall, Applied Thermal Engineering 30 (2010). [7] Dasmahapatra J. K, and Raja Rao M, Laminar Flow heat transfer to generalized power law fluids inside circular tubes fitted with regularly spaced twisted tape elements for uniform wall temperature condition, Fundamentals of Heat Transfer in Non-Newtonian Fluids, ASME, New York, pp. 51 58. [8] Al-Fahed S, and Chakroun W, 1996, Effect of tube -tape clearance on heat transfer for fully developed turbulent flow in a horizontal isothermal tube, Int. J. Heat Fluid Flow, Vol. 17, No. 2, pp. 173-178. [9] Manglik R.M and Bergles A.E, 1992, Heat transfer enhancement and pressure drop in viscous liquid flows in isothermal tubes with twisted-tape inserts, Heat and Mass Transfer, Vol. 27, No. 4, pp. 249-257. [10] Manglik R.M and Bergles A.E, Application of twisted tape inserts in tubular heat exchangers,heat and Mass Transfer, Vol. 27, No. 4, pp. 249-257. [11] Chang S.W, Yang T.L, Liou J.S, 2007. Heat transfer and pressure drop in tube with broken twisted tape insert, Experimental Thermal and Fluid Science, Vol. 32, No. 2, pp. 489 501. [12] Saha S. K andmallick D. N., September 2005. Heat transfer and pressure drop characteristics of laminar flow in rectangular and square plain ducts and ducts with twisted-tape inserts, Transactions of the ASME, Vol. 127. [13] Sivashanmugam, P. and Suresh, S. Experimental studies on heat transfer and friction factor characteristics of turbulent flow through a circular tube fitted with regularly spaced helical screw tape inserts, Advances in Energy Research, 2006, 468-473. [14] SibelGunes, VeyselOzceyhan, OrhanBuyukalaca, Heat transfer enhancement in a tube with equilateral triangle cross sectioned coiled wire inserts, Experimental Thermal and Fluid Science 34 (2010) 684 691. [15] Rahimi.M, Shabanian S.R., Alsairafi A.A., 2009. Experimental and CFD studies on heat transfer and friction factor characteristicsof a tube equipped with modified twisted tape inserts, Chemical Engineering and Processing, Vol. 48, pp. 762 770. [16] Chang S.W, Yang T.L, Liou J.S, 2007. Heat transfer and pressure drop in tube with broken twisted tape insert, Experimental Thermal and Fluid Science, Vol. 32, No. 2, pp. 489 501. [17] Chang S.W., Jan Y.J, Liou J.S., 2007. Turbulent heat transfer and pressure drop in tube fitted with serrated twisted tape, International Journal of Thermal Sciences, Vol. 46, No. 5, pp. 506 518. 35