Minimum (-31) every 10 s -35 (-31)

Similar documents

ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20

Acceleration/Velocity/Displacement VIBRATION METER

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Dewpoint Meter Data Sheet / Instructions

Data Sheet / Instructions. Dewpoint MeterO

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

566/568. Infrared Thermometers. Getting Started

Performance Measurements for Mechanical Air Handling Systems

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Software BioScout-Calibrator June 2013

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

E THERMADATA LOGGER Humidity & temperature recording meter

O P E R A T I N G M A N U A L

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

INFRARED THERMOMETER Model : TM-959

Website Phone Mobile OVERVIEW Davis Vantage Pro2 Weather Station

OPERATING INSTRUCTIONS

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

WM9280. Pro Family weather station with T/H sensor, pluviometer, anemometer, PC connection and Meteotime weather forecasts until 3 days

Simple circuits - 3 hr

SwemaMan 7 Operating instructions vers 1.13 MB_CW

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

PiCUS Calliper Version 3

Ion-Chamber Survey Meter OD-02

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

PHYS320 ilab (O) Experiment 2 Instructions Conservation of Energy: The Electrical Equivalent of Heat

User's Manual altimeter V1.1

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

Bright Advance Corporation

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

VIBRATION METER. Instruction Manual.

SOFTWARE USER MANUAL. Weather Capture Advance WS1640 WM9280

WS-9018U Wireless Weather Station. Instruction Manual

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

Use of Data Logger Devices in the Collection of Site- Specific Weather Information. Peter de Bruijn, RPF. June Fire Report FR

QUANTUM CONCEPT. Swimming User s Manual

3. Analytical measurement and testing Timing/Clocks-Climate measurement/hygrometer

Lab Activity H4 It s Snow Big Deal

Digital Torque Meter ADT-C Series OPERATION MANUAL

SPECIFICATION SHEET : FHS2-UNV-36L

473-SHX Dew Point Mirror

Dielectric Analysis of Solid Insulations

Experiment 14 It s Snow Big Deal

Orbit Support Pack for Excel. user manual

EcoSensa Technologies Sdn Bhd 17-2, Jalan Merbah 3,Bandar Puchong Jaya,47170 Puchong,Selangor,Malaysia. Phone: Fax:

Understanding the uncertainties associated with using the 5128A RHapid Cal portable humidity generator

Microcare LCD Solar MPPT User Documentation

GW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW

Experiment C-15 Distillation - part 1

ea980r Digital Anemometer User Manual

SGM8707 Micro-Power, CMOS Input, RRIO, 1.4V, Push-Pull Output Comparator

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Paramaters. Resolution 0.2 m (for measurements < 25 meas. / sec )

Introduction. Concepts Kinetics Order of reaction Reaction rate Colorimetry. Background

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

Product manual. Mylos KNX Shutter actuator 2CSY1104C/S

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

ph Probe ReallyEasyData com

SOTM LAB: P16 OHM S LAW I. TEACHER NOTES & GUIDELINES TITLE OF LAB: Ohm s Law DEVELOPERS OF LAB:

National Event Tree. **Combo Package** Eliminator 2000 Super & National Event Tree. Item # 3152 $849

CONTENTS. La Crosse Technology, Ltd. Page 1

Survey Meter OD-01 Address: Phone: Fax: URL:

HD32.2 WBGT Index HD 32.2 INSTRUMENT FOR THE ANALYSIS OF THE WBGT INDEX

FAQS. La Crosse Technology, Ltd. Page 1

Vantage PRO2 Quick. Reference Guide

Magnetic Fields. Experiment 1. Magnetic Field of a Straight Current-Carrying Conductor

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Lab 5 Enthalpy of Solution Formation

Manual Dew point scanner PCE-DPT 1

One-hand ph/temperature measuring instrument

Operating Instructions for Digital Manometer. Model: MAN-SD

SUNLIKE DISPLAY. Model No: SC2004C GENERAL SPECIFICATION

Instruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector

SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

CTC 155 / 350 / 660 Dry-block calibrator

Spectrophotometer for Life Science. BioSpec-nano C101-E112D

InfraRed Thermometer with Laser Pointer

Mini Environmental Quality Meter

ɣ-radiochromatography

UV3000. Accurate, precise, and portable ambient gas point analyzer

E2T0 DVP

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

473 Dew Point Hygrometer

Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

Order of a Reaction. Using Labquest and Colorimeter. Teachers Guide

Experiment P-5 Motion of a Cart on an Inclined Plane

Thermocouple TC-K Sensor 0 C to 1200 C

WATER ACTIVITY MEASUREMENT WATER ACTIVITY

Rapid RH Portable ph Meter. User's Manual

Transcription:

Humidity, and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-2-LCD BAT 3V6 1/2AA FEATURES 0 to 100 measurement range measurement range Dew point indication via Windows control software USB interface for set-up and data download User-programmable alarm thresholds for & T Status indication via red and green LEDs High contrast LCD, with two and a half digit temperature and humidity display function Immediate, delayed and push-to-start logging Supplied with replaceable internal lithium battery and Windows control software This standalone data logger measures and stores up to relative humidity and temperature readings over 0 to 100 and measurement ranges. The user can easily set up the logger and view downloaded data by plugging the data logger into a PC s USB port and using the supplied software. Relative humidity, temperature and dew point (the temperature at which water vapour present in the air begins to condense) data can then be graphed, printed and exported to other applications. The high contrast LCD can show a variety of temperature and humidity information. At the touch of a button, the user can cycle between the current temperature and humidity, along with the maximum and minimum stored values for temperature and humidity. The data logger is supplied complete with a long-life lithium battery, which can typically allow logging for up to. Speci cations Minimum Typical Maximum Unit Measurement range 0 100 Repeatability (short term) ±0.1 Relative Humidity Internal resolution ±3.0* 0.5 ±6 Long term stability 0.5 /Yr Measurement range -35 (-31) +80 (+176) Repeatability ±0.1 (±0.2) ±0.5 (±1) ±2 (±4) Internal resolution 0.5 (1) Dew Point ±1.1 (±2)** Logging rate every 10 s every 12 hr - Operating temperature range*** -35 (-31) +80 (+176) 1/2AA 3.6V Lithium Battery Life 1 Year * This speci es the overall error in the logged readings for relative humidity measurements between 20 and 80. ** This speci es the overall error in the calculated dew point for relative humidity measurements between 40 and 100 at 25 C. *** At temperatures below -20 C (-4 F) the LCD will exhibit slower response times of approximately 10 seconds. Depending on sample rate, ambient temperature and use of LCD. www.hcs77.com 519 686 2715 Speci cations liable to change without prior warning Issue 2 10 /09 S.C Applies to EL-USB-2-LCD Page 1 of 5

EL-WIN-USB (CONTROL SOFTWARE) EasyLog USB control software is supplied free of charge with each data logger. Easy to install and use, the control software runs under Windows 2000, XP (Home and Professional Editions) & Vista (32-bit). The software is used to set-up the data logger as well as download, graph and export data to Excel. The software allows the following parameters to be con gured: Logger name C, F Logging rate (10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms Immediate, delayed and push-to-start logging Display off, on for 30 seconds after button press, or permanently on Data rollover (allows unlimited logging per ods by overwriting the oldest data when the memory is full) The latest version of the control software may be obtained free of charge contact hcs@hcs77.com DISPLAY AND STATUS FUNCTIONS The EL-USB-2-LCD features a high contrast LCD and two bi-colour LEDs. The LCD shows logged temperature and humidity values using seven segment numbers, along with annunciators. The LCD can also show information regarding the logging status. Maximum logged value symbol Relative Humidity symbol Negative symbol Minimum logged value symbol Reading scale The LCD shows six different recorded readings, which can be cycled through using the built-in push button. The most recent logged value, maximum logged value and minimum logged value can be displayed separately for humidity and temperature. In addition, logging and alarm status is shown using two high intensity LEDs. Speci cations liable to change without prior warning Issue 2 10 /09 S.C Applies to EL-USB-2-LCD Page 2 of 5

LCD INDICATION Display Logger Status Explanation Delayed Start This is shown when the logger is set to start at a speci c data and time* Push to Start This is shown when the logger is setup for Push to start logging Logging Stopped This is shown when the logger is running in LCD off mode, and the button is pressed. The display clears again after three seconds If the logger has not been set to log and the button is pressed, three dashes are displayed for three seconds * If the logger is set to LCD off or LCD on for 30 seconds mode, then this will only be shown after the button is pressed. Otherwise the display will remain blank. LED FLASHING MODES EL-USB-2-LCD features 2 bi-colour LEDs; one LED represents temperature measurement, the other represents RH. Each is clearly marked on the logger. To save power, the status indication alternates between the two channels every 10 seconds. First you will see the status of the temperature logging, and 10 seconds later you will see the status of the RH logging, and so on. RH% RH% 10 seconds later Green double ash The data logger is not currently logging, but is primed to start at a later date and time (delayed start). Green single ash The data logger is currently logging. No alarm on the channel. Red single ash The data logger is currently logging. Low alarm on the channel. Red double ash The data logger is currently logging. High alarm on the channel. Green triple ash The data logger is full and has stopped logging. No alarm on the channel. RH% Red/ Green LED Red/ Green LED Red triple ash The data logger is full and has stopped logging. Alarm (high, low or both). No LEDs ash The data logger is stopped, the battery is empty or there is no battery tted. Speci cations liable to change without prior warning Issue 2 10 /09 S.C Applies to EL-USB-2-LCD Page 3 of 5

DIMENSIONS All dimensions in mm (inches) 126.0 (4.9) 22.1 (0.87) 25.3 (1.04) MEASUREMENT ACCURACY BATTERY REPLACEMENT We recommend that you replace the battery every 12 months, or prior to logging critical data. The EL-USB-2-LCD does not lose its stored readings when the battery is discharged or when the battery is replaced; however, the data logging process will be stopped and cannot be re-started until the battery has been replaced and the logged data has been downloaded to a PC. Only use 3.6V 1/2AA lithium batteries. Check with your supplier that the battery you are ordering is press t and is not tted with solder tags. Before replacing the battery, remove the EL-USB-2 from the PC. Note: Leaving the EL-USB-2 plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. WARNING Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. Speci cations liable to change without prior warning Issue 2 10 /09 S.C Applies to EL-USB-2-LCD Page 4 of 5

CAUTION Exposure of the internal sensor to chemical vapours such as those produced by some plastics and foamed materials may interfere with the internal sensor and cause inaccurate readings to be logged. In a clean environment, this will slowly rectify itself; therefore ensure that the logger is used in a ventilated area, i.e. air exchange is allowed. Exposure to extreme conditions or chemical vapours will require the following reconditioning procedure to bring the internal sensor back to calibration state. 80 C (176 F) at <5 for 36h (baking) followed by 20-30 C (70-90 F) at >74% RH for 48h (re-hydration). High levels of pollutants may cause permanent damage to the internal sensor. THE EASYLOG USB RANGE Each EL-USB data logger features the direct-to-usb connection and easy-to-use functionality that the range is known for. The range comprises 14 data loggers as detailed in the following table: Part No Function Range Typ. Max. Readings Battery Battery Life* EL-USB-1 EL-USB-1-PRO High temperature -40 to +125 C (-40 to +257 F) ±0.2ºC (±0.4ºF) 3.6V AA 3 years EL-USB-2, humidity & dew point ±2ºC (±4ºF) 0 to 100 ±3 ±6.0 EL-USB-2+ Increased accuracy temperature, humidity & dew point 0 to 100 ±0.3ºC (±0.6ºF) ±2.0 ±4.0 EL-USB-2-LCD, humidity & dew point with LCD 0 to 100 ±3.0 ±2ºC (±4ºF) ±6.0 EL-USB-2-LCD+ Increased accuracy temperature, humidity & dew point with LCD 0 to 100 ±0.3ºC (±0.6ºF) ±2.0 ±4.0 EL-USB-3 Voltage 0 to 30V d.c. ±1% EL-USB-4 Current loop 4 to 20mA ±1% EL-USB-TC Thermocouple (J, K and T-type) K-type probe included -200 to +1350ºC (-328 to +2462ºF) (K-type) -200 to +1190ºC (-328 to +2174ºF) (J-type) 6 months -200 to +390ºC (-328 to +734ºF) (T-type) EL-USB-TC-LCD Thermocouple with LCD (J, K and T-type) K-type probe included -200 to +1350ºC (-328 to +2462ºF) (K-type) -200 to +1190ºC (-328 to +2174ºF) (J-type) 6 months -200 to +390ºC (-328 to +734ºF) (T-type) EL-USB-CO Carbon monoxide 0 to 1000ppm NOT A LIFE SAVING DEVICE ±6ppm 3 months EL-USB-CO300 Carbon monoxide 0 to 300ppm NOT A LIFE SAVING DEVICE ±4ppm 3 months EL-USB-LITE Low cost temperature -10 C to +50 C (+14 to +122 F) 4,080 CR1620 Lithium coin cell 1 month EL-USB-RT Real-time temperature & humidity monitor -20 to +70 C (-4 to +158 F) ±4.5 7 days N/A N/A *Depending on logging rate, ambient temperature, and use of alarm LED Heaters Controls & Sensors Ltd 60 Meg Dr # 13 London Ontario N6E 3T6 Canada Tel : 519 686 2715 Fax : 519 686 8159 E : hcs@hcs77.com www.hcs77.comm www.hcs77.com Speci cations liable to change without prior warning Issue 2 10 /09 S.C Applies to EL-USB-2-LCD Page 5 of 5