Given Find Water Properties

Similar documents
Given Find Water Properties

MCE380: Measurements and Instrumentation Lab

Applied Fluid Mechanics

Applied Fluid Mechanics

Flow Measurement in Pipes and Ducts COURSE CONTENT

An Essential Requirement in CV Based Industrial Appliances.

Flow Measurement in Pipes and Ducts

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

Instrumentation & Data Acquisition Systems

Annubar Primary Element Flow Calculations

Flow Measurement in Pipes and Ducts COURSE CONTENT

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 11

Fundamentals of Flow Metering

CHAPTER (13) FLOW MEASUREMENTS

ME 2322 Thermodynamics I PRE-LECTURE Lesson 10 Complete the items below Name:

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes

VACUUM PUMPING METHODS

Flow : the motion of a fluid (1) Blood flowmeters : - ultrasonic (doppler, transit time) -electromagnetic (2) Gas flowmeters : - pneumotachometer

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

COURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

Turbulent Compressible Flow in a Slender Tube

Flow Measurement: Physical principle employed in various types of flow meters. PART 4 PREPARED BY: ESO OLUWATOBILOBA

When fluid incompressible...flow velocity, volumetric, and mass flow are proportional.

1.4 Perform the following unit conversions: (b) (c) s. g s. lb min. (d) (e) in. ft s. m 55 h. (f) ft s. km h. (g)

2.0 KEY EQUATIONS. Evaporator Net Refrigeration Effect. Compressor Work. Net Condenser Effect

FE Fluids Review March 23, 2012 Steve Burian (Civil & Environmental Engineering)

CHE-201. I n t r o d u c t i o n t o Chemical E n g i n e e r i n g. I N S T R U CTOR: D r. N a b e e l S a l i m A b o - Ghander.

Therefore, the control volume in this case can be treated as a solid body, with a net force or thrust of. bm # V

Experiment (4): Flow measurement

Lab Section Date. ME4751 Air Flow Rate Measurement

Volume and Mass Flow Rate Measurement Author: John M. Cimbala, Penn State University Latest revision: 07 December 2007

Fluid Flow Analysis Penn State Chemical Engineering

Calibration of Orifice Flow Meter and Venturi Flow Meter

Detailed Outline, M E 320 Fluid Flow, Spring Semester 2015

Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras

Discharge measurements

Experiment No.4: Flow through Venturi meter. Background and Theory

Applied Fluid Mechanics

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland

Orifice and Venturi Pipe Flow Meters

ME332 FLUID MECHANICS LABORATORY (PART I)

Control Engineering BDA30703

FLOW MEASUREMENT INC 331 Industrial process measurement 2018

EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW ELEMENTS

( KS A ) (1) , vapour, vapor (USA) , saturation vapour pressure. , standard reference conditions for gases. , degree of saturation

ME332 FLUID MECHANICS LABORATORY (PART II)

MASS, MOMENTUM, AND ENERGY EQUATIONS

Fluid Mechanics. Spring 2009

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

DOE FUNDAMENTALS HANDBOOK THERMODYNAMICS, HEAT TRANSFER, AND FLUID FLOW Volume 3 of 3

Siddharth Institute of Engineering & Technology

Nicholas J. Giordano. Chapter 10 Fluids

Orifice and Venturi Pipe Flow Meters

Today s menu. Last lecture. Measurement of volume flow rate. Measurement of volume flow rate (cont d...) Differential pressure flow meters

Chapter 5. Mass and Energy Analysis of Control Volumes

FLOWMETRY FLOWMETRY. FLUID-FLOW MEASUREMENT AND VISUALISATION

CHAPTER EIGHT P U M P I N G O F L I Q U I D S

Compressible Gas Flow

VENTURIMETER EXPERIMENT

Fluid Dynamics Exam #1: Introduction, fluid statics, and the Bernoulli equation March 2, 2016, 7:00 p.m. 8:40 p.m. in CE 118

ME 201 Thermodynamics

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0

Target Insertion Flowmeter

CONCEPTS AND DEFINITIONS. Prepared by Engr. John Paul Timola

Guidelines for the Selection and Operation of Provers with Micro Motion ELITE Coriolis Flow Meters

F L U I D S Y S T E M D Y N A M I C S

Liquids and solids are essentially incompressible substances and the variation of their density with pressure is usually negligible.

Industrial Instrumentation Prof. A. Barua Department of Electrical Engineering Indian Institute of Technology Kharagpur. Lecture - 14 Flowmeter ΙΙΙ

Rate of Flow Quantity of fluid passing through any section (area) per unit time

Pressure measurements

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

Experiment- To determine the coefficient of impact for vanes. Experiment To determine the coefficient of discharge of an orifice meter.

POWER UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES

Theory and Design for Mechanical Measurements

Fluid Mechanics 3502 Day 1, Spring 2018

Flowmeter Discharge Coefficient Estimation

9.1 Introduction. 9.2 Fluid Flow. CHAPTER 9 Flow

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd.

SOLUTION MANUAL ENGLISH UNIT PROBLEMS CHAPTER 4 SONNTAG BORGNAKKE VAN WYLEN. FUNDAMENTALS of. Thermodynamics. Sixth Edition

A drop forms when liquid is forced out of a small tube. The shape of the drop is determined by a balance of pressure, gravity, and surface tension

BLC Series - Basic Compact Pressure Sensor Series. Introduction

Course: TDEC202 (Energy II) dflwww.ece.drexel.edu/tdec

The online of midterm-tests of Fluid Mechanics 1

DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Sub Code/Name: ME 1304/Engineering Metrology & Measurements Year/Sem :III/ V UNIT-I

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Chapter 15 - Fluid Mechanics Thursday, March 24 th

Name: 10/21/2014. NE 161 Midterm. Multiple choice 1 to 10 are 2 pts each; then long problems 1 through 4 are 20 points each.

Chapter 6. Using Entropy

Measurement and Industrial Instrumentation

Lecture23. Flowmeter Design.

F kg. Discussion Note that large weights can be raised by little effort in hydraulic lift by making use of Pascal s principle.

Estimation of Flow Meter Losses

Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018

Chapter 1: INTRODUCTION AND BASIC CONCEPTS. Thermodynamics = Greek words : therme(heat) + dynamis(force or power)

CHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

9. Pumps (compressors & turbines) Partly based on Chapter 10 of the De Nevers textbook.

vector H. If O is the point about which moments are desired, the angular moment about O is given:

Anemometry Anemometer Calibration Exercise

ABB Flowmeters Review of industrial processing flowmeters

Transcription:

Venturi Example Given: A venturi is to be used to measure a 50 gpm flow of 70 F water in a 4-in ID pipe. Find: Select a throat diameter that provides Re d > 00,000 in the throat, and determine what differential pressure must be measured. Water Properties: µ = 6.58 10-4 lbm/ft-s =.37 lbm/ft-hr ρ = 6.3 lbm/ft 3

Venturi Example (Cont d) Sol n: Re d = ρvd/µ and, or: m& = m& = ρ Q 3 lbm gal min ft 6.3 50 60 0.13368 3 ft min hr gal m & =15,000 lbm Next, want Re in terms of mass flow rate: hr V d 4 m& ρ π m& = V = 4 ρ π d

Venturi Example (Cont d) Putting Re d in terms of mass flow rate... Re d = ρ ρ 4 m& π µ d Now can find d for various Re d (at highest mass flow rate): d = π d = π 4 m& Re d 4 m& d µ µ

Venturi Example (Cont d) For Re d = 00,000: lbm 4 15,000 d = hr = 0.336ft = lbm 00,000π.37 ft hr Since D = 4.00 in, we need a smaller d and should have no problem with Re d > 00,000. Choose d = inches for convenience. 4.03in

Venturi Example (Cont d) lbm 4 m& 4 15,000 Re hr d = = = π d µ lbm π ft.37 1 ft hr 403,000 Next we rearrange the YMCA Equation: Q = Y M C A ( P P ) 1 ρ

Venturi Example (Cont d) Solving for P = P 1 -P : P = Y ρ M Q C A For incompressible fluid (water), Y = 1. π ft 1 A = = 0.0181 ft 4

Venturi Example (Cont d) 4 π ft 1 A 1 = = 0.0877 ft 4 M = 1 1 A A 1 = 1 1 ( 0.0181 ) 0.0877 = 1.033

Venturi Example (Cont d) Correction factor C can be obtained from the obstruction meter handout or from text Table 10.1 (p. 80). Use Table 10.1 for a machined entrance, note we have β = d/d = in/4 in = 0.5, and Re D = 01,000 (calculation not shown). β, D and Re D > 10 5 fall within the given ranges, so the value C = 0.995 applies.

Venturi Example (Cont d) Inserting these values into the equation for P: P = lbm 6.3 3 ft 1 1.033 50 0.995 gal min lbf P = 597 ft = 0.13368 gal ft ( ) 0.0181 ft 3. 4.15 3 psi 1min 60s ft lbm lbf s

Rotameter Simple device for liquid and gas flow measurement This is a variable area meterthe rotameter uses a tapered tube with ball or float. As flow increases, float moves upward until fluid lift balances weight of float. Rotameter scale indicates fluid for which it is calibrated. Other fluids need correction.

Typical Rotameters

Rotameter Correction Rotameters are calibrated for only one fluid at given T and P (P not important for liquids). When the fluid is different or the conditions are different, the rotameter reading must be corrected to obtain the correct flow rate. Significant changes in use of rotameter yield loss in accuracy.

Rotameter Correction- Liquids For liquids, the correction equation is: Q Q act gage = ρ ρ b b ρ ρ act gage gage where Q gage is gage flow rate reading, Q act is corrected (actual) flow rate, ρ is density, subscript gage indicates fluid and conditions for which gage was calibrated, subscript act indicates actual fluid and conditions measured, and ρ b is the float density. 1 ρ ρ act 1

Rotameter Correction- Gases The correction equation for gases is: Q Q act gage = P gage P act T T gage gage where Q gage is gage flow rate reading, Q act is corrected flow rate, P is absolute pressure, T is absolute temperature, M is molecular weight, subscript gage refers to conditions for which rotameter was calibrated, and subscript act refers to actual measured conditions and fluid. act M M act 1

Rotameter Correction Example Given: A rotameter stamped scfh air @ 70 F, 10 psig reads 36.3 scfh for a flow of O at 7. psig and 9 F. Find: The actual oxygen mass flow rate assuming that standard T and P are 60 F and 14.7 psia. Sol n: Use the rotameter correction equation to obtain the volumetric flow rate of O.

Rotameter Example (Cont d) Starting with correction equation: Q P act gage T M act gage = Q gage Pact Tgage M act insert values (using absolute T and P!): 10+ 14.7 9 + 460 8.97 QO = 36.3 scf 7. + 14.7 70+ 460 3 Actual O volumetric flow rate: Q = 7.1 scfh 1 1

Rotameter Example (Cont d) To get mass flow rate, use: We need to use the ideal gas equation to obtain the density of O at standard conditions of P = 14.7 psia, T = 50 R: ρ = O RT m& = ρ Q and we need to calculate the gas constant for oxygen: P

Rotameter Example (Cont d) ft lbf 1545 R R = = lbmol R M lbm 3 lbmol Oxygen density is: ρ O lbf in 14.7 144 = in ft = ft lbf 48.3 50 R lbm R = ft lbf 48.3 lbm R 0.0848 lbm ft 3

Rotameter Example (Cont d) Finally, the mass flow rate of O is: 3 lbm ft m& O = ρ Q = 0.0848 7.1 = 3 ft hr.8 lbm hr

Spring-Loaded Rotameter The conventional rotameter uses the gravitational force, consequently it must be oriented vertically. Rotameters should be installed using a level to assure correct vertical orientation. Rotameters are available that oppose the flow drag force on the bob with a spring force. These can be oriented in any direction, but typically are less accurate.

Spring-Loaded Rotameter

Wet Test Meter A positive displacement gas flow meter. Meter is water filled. It counts the number of times a fixed water volume is displaced by gas. To get flow rate, meter is timed for some number of displaced volumes. Gas is exposed to liquid, so corrections must be made for water evaporation into the gas. Normally assume gas is saturated with water vapor before exiting the meter.

Wet Test Meter Correction Gas volume is measured at some T and P (T, P also must be measured), but rate is desired at standard T, P (standards vary...) Use ideal gas law: The dry gas flow rate is desired: m& dry gas P = RT std std Q std m& = PV & = RT P dry,m RT m = Q P RT m Q

Wet Test Meter Correction Thus, the standard dry gas volumetric flow rate is: Q std = P dry,m P Total measured pressure, P m is the sum of the dry gas partial pressure, P dry,m, and H O partial pressure, which is P sat at T m, so: std T T std m Q m P dry, m = P m P sat @ T m

Wet Test Meter Correction Putting this all together, the standard dry gas volumetric flow rate is: ( ) P P T Q = m sat @ Tm std std P T std m Q m

Hot Wire Anemometer A hot wire anemometer is a probe used to measure local velocity (like a pitot tube). It s a small, resistance wire, often platinum or tungsten, held at constant T by electric current. Heat loss from wire is proportional to both ha T and I R, and h is proportional to velocity, so measurement of I can be used to obtain velocity.

Hot Wire Construction

Hot Wire Anemometer

Turbine Meters A turbine meter is a small turbine inserted in a pipe so that all flow passes over it. The blade rotational frequency is sensed as a pulse rate by a magnetic pickup. Meter is calibrated so Q = f /K, where f is frequency and K is the flow coefficient. Typical K units: pulses/gal, pulses/liter, etc. Turbine meters have high accuracy, good transient response, and wide linear range.

Turbine Meter Assembly

Turbine Meter

Paddlewheel Meter Poor man s turbine meter- cheaper but less accurate. Partial insertion in flow.

Water Meter Some rate flow meters can integrate volumetric flow over time to get total volume (a totalizing meter). a water meter gives a positive displacement measurement of total volume of liquid passed through (rather than flow rate). Similar meters are used for measuring water usage, gasoline pumped, etc. Following is a nutating vane water meter.

Mass Flow Meter/Controller A mass flow meter is a gas flow instrument that is relatively insensitive to gas P, ρ and T. Based on relation: q= m& c T p The value of c p is known and relatively constant over a fairly broad T range. The value of q is measured as q = I R. The value of T is measured also, so the only unknown is m&

Mass Flow Meter The mass flow meter can be used as feedback to control a modulating valve, thus providing a mass flow controller. Mass flow meter works only on a single gas. Mass flow meters provide about ±1% accuracy at rated conditions and cost $100 to $000. The controller option adds ~$600 to cost.

Constant fractional bypass flow Mass flow meter schematic