Imaging based optofluidic air flow meter with polymer interferometers defined by soft lithography

Similar documents
Tuning parameters of metal ion implantation within a microfluidic channel

SUPPLEMENTAL MATERIAL I: SEM IMAGE OF PHOTONIC CRYSTAL RESONATOR

Lecture 18: Microfluidic MEMS, Applications

Laser. emission W FL

Mechanical characterization of single crystal BaTiO 3 film and insitu. XRD observation of microstructure change due to

CURRENT STATUS OF NANOIMPRINT LITHOGRAPHY DEVELOPMENT IN CNMM

1 N star coupler as a distributed fiber-optic strain sensor in a white-light interferometer

arxiv: v1 [physics.optics] 21 Nov 2011

A Multifunctional Pipette

Optimum Access Waveguide Width for 1xN Multimode. Interference Couplers on Silicon Nanomembrane

Foundations of MEMS. Chang Liu. McCormick School of Engineering and Applied Science Northwestern University. International Edition Contributions by

Particle concentration influences inertial focusing in Multiorifice Flow Fractionation microfluidic devices

PANDA ring resonator for optical Gas and Pressure sensing applications

Sensing: a unified perspective for integrated photonics

Full-color Subwavelength Printing with Gapplasmonic

Introduction to Microeletromechanical Systems (MEMS) Lecture 9 Topics. MEMS Overview

Sheathless Hydrophoretic Particle Focusing in a Microchannel with Exponentially Increasing Obstacle Arrays

PROCEEDINGS OF SPIE. Nanoparticle sorting in silicon waveguide arrays. H. T. Zhao, Y. Zhang, L. K. Chin, P. H. Yap, K. Wang, et al.

Introduction to Micro/Nanofluidics. Date: 2015/03/13. Dr. Yi-Chung Tung. Outline

Wavelength switchable flat-top all-fiber comb filter based on a double-loop Mach-Zehnder interferometer

Design of a Multi-Mode Interference Crossing Structure for Three Periodic Dielectric Waveguides

Dielectrophoresis-actuated in-plane optofluidic lens with tunability of focal length from negative to positive

Supplementary Information

PRINCIPLES OF PHYSICAL OPTICS

Geometry Induced Microparticle Separation in Passive Contraction Expansion Straight Channels

ME381 Introduction to MEMS

Supplementary Information

ESS 5855 Surface Engineering for. MicroElectroMechanicalechanical Systems. Fall 2010

Wave-front generation of Zernike polynomial modes with a micromachined membrane deformable mirror

Polarization control and sensing with two-dimensional coupled photonic crystal microcavity arrays. Hatice Altug * and Jelena Vučković

Experimental mixing characterization of Newtonian fluids mixing in asymmetric T-micromixers

VACUUM SUPPORT FOR A LARGE INTERFEROMETRIC REFERENCE SURFACE

Supplementary Figures

PROCEEDINGS OF SPIE. Sorting and measurement of single gold nanoparticles in an optofluidic chip

Dielectric Meta-Reflectarray for Broadband Linear Polarization Conversion and Optical Vortex Generation

LASER TRAPPING MICRO-PROBE FOR NANO-CMM

Micro- and Nano-Technology... for Optics

Optics.

SUPPLEMENTARY INFORMATION

ENMA490 Capstone: Design of Microfluidics Mixer

Ultrasensitive magnetic field sensor based on an in-fiber Mach Zehnder interferometer with a magnetic fluid component

Ultrasonic particle and cell separation and size sorting

Cruz, J., Hooshmand Zadeh, S., Wu, Z., Hjort, K. (2016) Inertial focusing of microparticles and its limitations. In: (pp. 1-6).

Postprint.

Characterization of MEMS Devices

A tunable optofluidic lens based on combined effect of hydrodynamics and electroosmosis

3.032 Problem Set 4 Fall 2007 Due: Start of Lecture,

GRATING CLASSIFICATION

A refractive index sensor based on the leaky radiation of a microfiber

NUMERICAL INVESTIGATION OF THERMOCAPILLARY INDUCED MOTION OF A LIQUID SLUG IN A CAPILLARY TUBE

Resonator Fabrication for Cavity Enhanced, Tunable Si/Ge Quantum Cascade Detectors

Strong Coupling between On Chip Notched Ring Resonator and Nanoparticle

Gratings in Electrooptic Polymer Devices

Micro Cooling of SQUID Sensor

Behavior of microdroplets in diffuser/nozzle structures

Pressure-Driven Laminar Flow in Tangential Microchannels: an Elastomeric Microfluidic Switch

Highly Efficient and Anomalous Charge Transfer in van der Waals Trilayer Semiconductors

Chapter 5. Effects of Photonic Crystal Band Gap on Rotation and Deformation of Hollow Te Rods in Triangular Lattice

X-Rays From Laser Plasmas

Spatial Coherence Properties of Organic Molecules Coupled to Plasmonic Surface Lattice Resonances in the Weak and Strong Coupling Regimes

Fadei Komarov Alexander Kamyshan

Fabrication of a microresonator-fiber assembly maintaining a high-quality factor by CO 2 laser welding

Introduction to Photolithography

Material Limitations on the Detection Limit in Refractometry. West, DK-2800 Kongens Lyngby, Denmark; (S.X.

Supplementary Methods

Deformable MEMS grating for wide tunability and high operating speed

Interested in exploring science or math teaching as a career?

Microfluidics 1 Basics, Laminar flow, shear and flow profiles

Birefringence dispersion in a quartz crystal retrieved from a channelled spectrum resolved by a fibre-optic spectrometer

Recent Advances in Optical Leak Testing (OLT)

Supporting Information: PDMS Nanocomposites for Heat Transfer Enhancement in. Microfluidic Platforms

Fabrication-tolerant high quality factor photonic crystal microcavities

Supplementary information for

3D Micropatterned Surface Inspired by Salvinia

A STUDY ON MULTI-AXIS FORCE MEASUREMENT OF POLYMER SKINS USING FBG SENSOR

MICRO-SCALE SHEET RESISTANCE MEASUREMENTS ON ULTRA SHALLOW JUNCTIONS

Repeating monomer of SiO(CH 3 ) units. Polymerization causes cross linking. Visco elastic polymer (Based on n ). Intrinsically hydrophobic.

Simulations of nanophotonic waveguides and devices using COMSOL Multiphysics

Simultaneous Temperature and Strain Sensing for Cryogenic Applications Using Dual-Wavelength Fiber Bragg Gratings

Photonic Crystal Nanocavities for Efficient Light Confinement and Emission

SUBSTITUTING particle-sensitive check-valves in micropumps

NSC E

Demonstration of Near-Infrared Negative-Index Materials

Experiment 3 1. The Michelson Interferometer and the He- Ne Laser Physics 2150 Experiment No. 3 University of Colorado

Nanoparticle Devices. S. A. Campbell, ECE C. B. Carter, CEMS H. Jacobs, ECE J. Kakalios, Phys. U. Kortshagen, ME. Institute of Technology

Design of Electrostatic Actuators for MOEMS Applications

Introduction. Procedure. In this experiment, you'll use the interferometer to EQUIPMENT NEEDED: Lens 18mm FL. Component holder.

Computational Fluid Dynamical Simulations of Droplet Flow and Merger in Microfluidic Channels

ME332 FLUID MECHANICS LABORATORY (PART I)

Fabrication and Characterization of High Performance Micro Impedance Inclinometer

U-Shaped Nano-Apertures for Enhanced Optical Transmission and Resolution

Three-Dimensional Silicon Photonic Crystals

Modeling liquid-crystal devices with the three-dimensional full-vector beam propagation method

Optics of complex micro structures

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Development of Polarization Interferometer Based on Fourier Transform Spectroscopy for Thomson Scattering Diagnostics

Laboratory 3: Confocal Microscopy Imaging of Single Emitter Fluorescence and Hanbury Brown, and Twiss Setup for Photon Antibunching

Noise analysis of spectrometers based on speckle pattern reconstruction

A tunable three layer phase mask for single laser exposure 3D photonic crystal generations: bandgap simulation and holographic fabrication

Density Field Measurement by Digital Laser Speckle Photography

Transcription:

Imaging based optofluidic air flow meter with polymer interferometers defined by soft lithography Wuzhou Song* and Demetri Psaltis Optics Laboratory, School of Engineering, Swiss Federal Institute of Technology Lausanne (EPFL), CH-1015 Lausanne, Switzerland *wuzhou.song@epfl.ch Abstract: We present an optofluidic chip with integrated polymer interferometers for measuring both the microfluidic air pressure and flow rate. The chip contains a microfluidic circuit and optical cavities on a polymer which was defined by soft lithography. The pressure can be read out by imaging the interference patterns of the cavities. The air flow rate was then calculated from the differential pressure across a microfluidic Venturi circuit. Air flow rate measurement in the range of 0-2mg/second was demonstrated. This device provides a simple and versatile way for in situ measuring the microscale air pressure and flow on chip. 2010 Optical Society of America OCIS codes: (120.5475) Pressure measurement; (120.3180) Interferometry; (350.3950) Microoptics. Reference and links 1. D. Psaltis, S. R. Quake, and C. Yang, Developing optofluidic technology through the fusion of microfluidics and optics, Nature 442(7101), 381 386 (2006). 2. C. Monat, P. Domachuk, and D. J. Eggleton, Integrated optofluidics: a new river of light, Nat. Photonics 1(2), 106 114 (2007). 3. X. Wu, Y. Sun, J. D. Suter, and X. Fan, Single mode coupled optofluidic ring resonator dye lasers, Appl. Phys. Lett. 94(24), 241109 (2009). 4. F. B. Arango, M. B. Christiansen, M. Gersborg-Hansen, and A. Kristensen, Optofluidic tuning of photonic crystal band edge lasers, Appl. Phys. Lett. 91(22), 223503 (2007). 5. W. Song, A. E. Vasdekis, Z. Li, and D. Psaltis, Low-order distributed feedback optofluidic dye laser with reduced threshold, Appl. Phys. Lett. 94(5), 051117 (2009). 6. W. Song, A. E. Vasdekis, Z. Li, and D. Psaltis, Optofluidic evanescent dye laser based on a distributed feedback circular grating, Appl. Phys. Lett. 94(16), 161110 (2009). 7. C. Karnutsch, C. C. Smith, A. Graham, S. Tomljenovic-Hanic, R. McPhedran, B. J. Eggleton, L. O Faolain, T. F. Krauss, S. Xiao, and N. A. Mortensen, Temperature stabilization of optofluidic photonic crystal cavities, Appl. Phys. Lett. 94(23), 231114 (2009). 8. A. Groisman, S. Zamek, K. Campbell, L. Pang, U. Levy, and Y. Fainman, Optofluidic 1x4 switch, Opt. Express 16(18), 13499 13508 (2008). 9. X. Mao, J. R. Waldeisen, B. K. Juluri, and T. J. Huang, Hydrodynamically tunable optofluidic cylindrical microlens, Lab Chip 7(10), 1303 1308 (2007). 10. C. Hilty, E. E. McDonnell, J. Granwehr, K. L. Pierce, S. I. Han, and A. Pines, Microfluidic gas-flow profiling using remote-detection NMR, Proc. Natl. Acad. Sci. U.S.A. 102(42), 14960 14963 (2005). 11. D. S. Chang, S. M. Langelier, and M. A. Burns, An electronic Venturi-based pressure microregulator, Lab Chip 7(12), 1791 1799 (2007). 12. S. Li, J. C. Day, J. J. Park, C. P. Cadou, and R. Ghodssi, A fast-response microfluidic gas concentrating device for environmental sensing, Sens. Actuators A Phys. 136(1), 69 79 (2007). 13. M. Yamada, and M. Seki, Nanoliter-sized liquid dispenser array for multiple biochemical analysis in microfluidic devices, Anal. Chem. 76(4), 895 899 (2004). 14. M. A. Unger, H. P. Chou, T. Thorsen, A. Scherer, and S. R. Quake, Monolithic microfabricated valves and pumps by multilayer soft lithography, Science 288(5463), 113 116 (2000). 15. W. Song, and D. Psaltis, Pneumatically tunable optofluidic dye laser, Appl. Phys. Lett. 96(8), 081101 (2010). 16. Y. Xu, C. Chiu, F. Jiang, Q. Lin, and Y. Tai, A MEMS multi-sensor chip for gas flow sensing, Sens. Actuators A Phys. 121, 253 261 (2005). 17. P. Enoksson, G. Stemme, and E. Stemme, A silicon resonant sensor structure for Coriolis mass-flow measurements, J. Microelectromech. Syst. 6(2), 119 125 (1997). 18. R. W. Miller, Flow Measurement Engineering Handbook, 3rd ed. (McGraw-Hill, 2006). (C) 2010 OSA 2 August 2010 / Vol. 18, No. 16 / OPTICS EXPRESS 16561

1. Introduction In the past years optofluidic has received substantial attention in both microfluidics and optics. With the development of microtechnology, multiple optofluidic devices have been realized by merging the optics and fluidics synergistically [1,2], such as dye lasers [3 6], tunable photonics crystals [7], optical switches [8] and fluidic lens [9]. In such devices, the optical functional fluids are normally in the liquid form. On the other hand, the gas phase microfluidic devices have also attracted much attention [10 12]. For example, compressed air has become one of the dominated methods to manipulate the liquid analyte for lab-on-a-chip applications, either by pushing the liquid directly or by actuating the membrane valve [13,14]. However, few works have been reported on the optofluidic devices which combine optics with the gas phase microfluidics. Very recently a pneumatically tunable optofluidic dye laser has been reported in which a microchannel based tunable air-gap etalon can be adjusted by air pressure [15]. Since the air pressure has been extensively utilized to manipulate both the liquid and optical elements on a chip, measurement of the air pressure and flow becomes desirable especially for local measurement inside the microfluidic chip. In this work, we demonstrate an optical interferometric air pressure sensor and flow meter based on an air circulating optofluidic chip. Different from the MEMS (Microelectronic and Microelectromechanical Systems) based pressure or flow sensors which require sophisticated fabrication process with silicon [16,17], this optofluidic sensor was defined on a polymer chip with soft lithography and the measurement was done by imaging the interference pattern from the chip. This sensor can be simply fabricated with low cost. Fig. 1. The structure of optical chip including the microfluidic channel and optical cavities. The chip structure is illustrated in Fig. 1. It consists of a structured Polydimethylsiloxane (PDMS) polymer layer bonded onto a rigid glass substrate. The structure inside the chip can be divided into two parts: the microfluidic channel and two separate optical cavities. The air flows in the main microfluidic channel. While in the channel middle part there exists a slit type Venturi tube for differential pressure based air flow measurement. Due to the elasticity of the polymer, the polymer optical cavities can be deformed by the local air pressure. Upon illuminating by monochromatic light, a Newton s ring pattern was formed in the cavities. By imaging and analyzing this interference pattern we can calculate the air pressure and hence the flow rate. (C) 2010 OSA 2 August 2010 / Vol. 18, No. 16 / OPTICS EXPRESS 16562

Fig. 2. The cross-section view and working principle of the optical cavity. Bottom picture shows the corresponding interference image on microscope. The cross section of the optical cavity for pressure sensing is shown in Fig. 2. The top PDMS layer has a round chamber structure with flat inner surface. A thin air gap is formed between the PDMS chamber and glass substrate. Thanks to the flexibility of the PDMS, after filling with compressed air, the PDMS surface in the cavity was deflected into a curvature depending on the pressure value (all pressure here means the relative pressure to the atmosphere). When the cavity is illuminated by a coherent monochromatic light, the reflected light from the two inner surfaces of the cavity can interfere with each other constructively or destructively depending on the gap size. Thus the resulting total reflection intensity can be expressed as: 4dπ I = I1+ I2+ 2 I1I2 cos + π, λ where I1 and I2 are the reflection intensity from the PDMS-air interface and air-glass interface respectively; d is the local air gap size; λ is the wavelength of the illuminating light. Due to the low reflectivity (< 4%) of these two interfaces, I 1 and I 2 have very close values hence resulting in good contrast of the interference pattern. Multiple reflections can be neglected in this model. As the PDMS/air interface will be deformed to a dome shape upon applying air pressure, the cavity generates multiple concentric ring interference fringes, similar to the Newton ring pattern. Figure 3 shows the measuring principle of the air flow meter which is based on Venturi effect on a planar microfluidic Venturi tube. The Venturi tube is a section of the channels with a tapered entrance and a straight throat. As the fluid passes through the throat, the velocity increases. According to the Bernoulli s equation, the pressure drop across the constriction is proportional to the square of the flow rate. Thus the air flow rate Q can be expressed in a simplified form as [18]: (1) Q= k P ρ, (2) 1 where Q is the mass flow rate; P= P1 P2 is the differential pressure; ρ1 is the gas density before the entrance of the Venturi tube; k is a coefficient depending on the structure dimensions, environment temperature and other flow conditions. In this experiment, the temperature was assumed to be constant, so the air mass density ρ 1 before the taper entrance has ρ1 P1 Thus the air mass flow rate can be also expressed as: Q= k P P 1. (3) (C) 2010 OSA 2 August 2010 / Vol. 18, No. 16 / OPTICS EXPRESS 16563

2. Fabrication Fig. 3. The schematic of the Venturi tube for measuring the flow rate. The structured PDMS layer was fabricated by soft-lithography in one step. It was replicated from a master mold which had double layers of structured negative photoresist SU-8 on a silicon wafer. The bottom layer of SU-8 had thickness of 15 um for defining the cavity structures. The cavity has a 300 µm diameter. After developing the first layer, a second layer of SU-8 was spun on top of it with a thickness of 50 um for defining the microfluidic channel. The main channel has width of 300 µm, and the width of the throat part is 50 µm. The PDMS was prepared by mixing the prepolymer component in 10:1 ratio (base: curing agent, Dow Corning Sylgard 184) and then baked in and oven at 80 degrees for 2 hours. Finally the PDMS layer was bonded on the glass substrate using oxygen plasma treatment. 3. Experiment and result The chip was measured on a normal bright field microscope (Infinity Microscope and Mitutoyo M Plan Apo 5x objective) with a built-in beam splitter for illumination. The light source was based on a wideband light source (Dolan-Jenner PL-800 Illuminator) plus a laser line filter (Thorlabs, FL632.8-1) with a transmission linewidth of 1 nm. Instead of using the laser, this monochromatic light source was found to provide sufficient coherence for generating interference patterns and while suppressing almost completely the speckle noise. The image was recorded by a monocolor CCD camera. The air pressure was generated from a mechanical air pressure regulator (100-AB, Air Control Inc.) and calibrated with a digital pressure gauge (Omega DPG4000). The air flow was controlled by a digital mass flow controlled (Brooks Inc.). Fig. 4. An example image of the chip recorded on microscope. (C) 2010 OSA 2 August 2010 / Vol. 18, No. 16 / OPTICS EXPRESS 16564

Fig. 5. The calibration results of the cavity P1. (a) The normalized average intensity at the center of the cavity versus the pressure. (b) The corresponding air gap size at the center versus the pressure. Figure 4 shows an example image of the chip captured on the microscope. The cavities on the left and right correspond to the pressure sensor P1 and P 2. The interference patterns consist of dark and bright co-centric rings which moved out from the center to the side as the pressure increased. Before the air flow measurements, these two pressure sensors were calibrated with the digital pressure gauge. Figure 5(a) shows the plot of the average intensity of the center in the left cavity P1 versus the applied pressure, as denoted by the red solid squares. The scatter plot reveals a typical sinusoidal relationship which fits very well to a sine curve denoted by the black line. Based the Eq. (1), the increment of the air gap in the center can be calculated. The reconstructed result reveals nice linearity in the pressure range 0-6 psi as plotted by the air gap increment (red square dots) versus the applied pressure in Fig. 5(b). The sensitivity was calculated as 1.46 fringes per psi. As the left and right optical cavities are not exactly identical, two separate calibrations were done. The digital mass flow meter was connected to a compress air source providing arbitrary air flow with predefined value. For the same air flow rate, different air pressure at the inlet of the chip was also tested by adjusting the resistance at the chip outlet. The interference images of the two cavities were recorded and analyzed according calibration results shown above. The result is shown in the Fig. 6. The plot shows the relation of the measured value of P1 ( P1 P2 ) versus the flow rate (mg/second) which can fit Eq. (3) very well. Thus the value of the 1 1 coefficient k was calculated to be 0.377 mg s psi. Fig. 6. The plot of the measured value of P1 ( P1 P2 ) versus air mass flow rate. The inset pictures are the representative images recorded at each flow rate. (C) 2010 OSA 2 August 2010 / Vol. 18, No. 16 / OPTICS EXPRESS 16565

At the same flow rate, the values of P1 ( P1 P2 ) (shown as different shapes on graph) give a slight deviation corresponding to different pressure condition at the inlet. Figure 7 illustrates the dependence of the measurement error versus different inlet pressure at certain flow rate. Here the measurement error is the differential value between the calculated value from Eq. (3) and the setting value of the digital mass flow controller. Fig. 7. The plot of the measurement error versus different inlet pressure at each flow rate. For a given flow rate, the measurement errors seem random related to the variation of inlet pressures. This could be the result of the inaccuracy from the pressure sensing. For different flow rates, the measurement error has a tendency to increase monotonically with the flow rate. Such deviation was estimated to relate to the inaccuracy of Eq. (3) or the deformation of the microfluidic channel or another more complicated effect. However, this air flow meter still provides satisfied accuracy which is below ± 3% at full scale of 2 mg/s. The accuracy and dynamic range of this device are mainly limited by the mechanical properties of the PDMS. Firstly, the shape memory effect of PDMS is the main factor restricting the accuracy of pressure measurement; secondly, for high pressure and large flow rate, there is a slight deformation in the venture channel which can also induce errors. 4. Conclusion In conclusion, we have demonstrated an optofluidic chip for simultaneously measuring the microfluidic air pressure and the flow rate through imaging. Both the microfluidic and optical structures were fabricated by soft-lithography on a polymer chip in a single step. Compared to the conventional miniature air pressure sensor or air flow meter which relies on complex MEMS fabrication process [17], this polymer based optofluidic air flow sensing chip can be made in mass production with very low cost. More importantly, as being compatible with the normal microfluidic in terms of fabrication and characterization [14], this device can be easily integrated into a lab-on-a-chip system for in situ measuring the air pressure and flow rate, Multipoint pressure or flow rate measurement are also feasible by simultaneously imaging the interference patterns on multiple cavities. (C) 2010 OSA 2 August 2010 / Vol. 18, No. 16 / OPTICS EXPRESS 16566