Given Find Water Properties

Similar documents
Given Find Water Properties

MCE380: Measurements and Instrumentation Lab

Applied Fluid Mechanics

Applied Fluid Mechanics

Flow Measurement in Pipes and Ducts COURSE CONTENT

An Essential Requirement in CV Based Industrial Appliances.

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

Flow Measurement in Pipes and Ducts COURSE CONTENT

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 11

Flow Measurement in Pipes and Ducts

Instrumentation & Data Acquisition Systems

CHAPTER (13) FLOW MEASUREMENTS

Fundamentals of Flow Metering

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

Flow : the motion of a fluid (1) Blood flowmeters : - ultrasonic (doppler, transit time) -electromagnetic (2) Gas flowmeters : - pneumotachometer

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

COURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

Flow Measurement: Physical principle employed in various types of flow meters. PART 4 PREPARED BY: ESO OLUWATOBILOBA

When fluid incompressible...flow velocity, volumetric, and mass flow are proportional.

ME 2322 Thermodynamics I PRE-LECTURE Lesson 10 Complete the items below Name:

FE Fluids Review March 23, 2012 Steve Burian (Civil & Environmental Engineering)

Experiment (4): Flow measurement

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes

Lab Section Date. ME4751 Air Flow Rate Measurement

Volume and Mass Flow Rate Measurement Author: John M. Cimbala, Penn State University Latest revision: 07 December 2007

Calibration of Orifice Flow Meter and Venturi Flow Meter

2.0 KEY EQUATIONS. Evaporator Net Refrigeration Effect. Compressor Work. Net Condenser Effect

Detailed Outline, M E 320 Fluid Flow, Spring Semester 2015

Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras

Therefore, the control volume in this case can be treated as a solid body, with a net force or thrust of. bm # V

Discharge measurements

Annubar Primary Element Flow Calculations

Experiment No.4: Flow through Venturi meter. Background and Theory

Applied Fluid Mechanics

ME332 FLUID MECHANICS LABORATORY (PART I)

Control Engineering BDA30703

FLOW MEASUREMENT INC 331 Industrial process measurement 2018

( KS A ) (1) , vapour, vapor (USA) , saturation vapour pressure. , standard reference conditions for gases. , degree of saturation

ME332 FLUID MECHANICS LABORATORY (PART II)

MASS, MOMENTUM, AND ENERGY EQUATIONS

Fluid Flow Analysis Penn State Chemical Engineering

VACUUM PUMPING METHODS

Nicholas J. Giordano. Chapter 10 Fluids

Siddharth Institute of Engineering & Technology

Today s menu. Last lecture. Measurement of volume flow rate. Measurement of volume flow rate (cont d...) Differential pressure flow meters

FLOWMETRY FLOWMETRY. FLUID-FLOW MEASUREMENT AND VISUALISATION

VENTURIMETER EXPERIMENT

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland

1.4 Perform the following unit conversions: (b) (c) s. g s. lb min. (d) (e) in. ft s. m 55 h. (f) ft s. km h. (g)

CHE-201. I n t r o d u c t i o n t o Chemical E n g i n e e r i n g. I N S T R U CTOR: D r. N a b e e l S a l i m A b o - Ghander.

F L U I D S Y S T E M D Y N A M I C S

Fluid Mechanics. Spring 2009

CONCEPTS AND DEFINITIONS. Prepared by Engr. John Paul Timola

Industrial Instrumentation Prof. A. Barua Department of Electrical Engineering Indian Institute of Technology Kharagpur. Lecture - 14 Flowmeter ΙΙΙ

Pressure measurements

DOE FUNDAMENTALS HANDBOOK THERMODYNAMICS, HEAT TRANSFER, AND FLUID FLOW Volume 3 of 3

Experiment- To determine the coefficient of impact for vanes. Experiment To determine the coefficient of discharge of an orifice meter.

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

Rate of Flow Quantity of fluid passing through any section (area) per unit time

Theory and Design for Mechanical Measurements

POWER UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES

Fluid Mechanics 3502 Day 1, Spring 2018

Flowmeter Discharge Coefficient Estimation

9.1 Introduction. 9.2 Fluid Flow. CHAPTER 9 Flow

DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Sub Code/Name: ME 1304/Engineering Metrology & Measurements Year/Sem :III/ V UNIT-I

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Chapter 15 - Fluid Mechanics Thursday, March 24 th

The online of midterm-tests of Fluid Mechanics 1

Measurement and Industrial Instrumentation

Chapter 6. Using Entropy

Lecture23. Flowmeter Design.

Liquids and solids are essentially incompressible substances and the variation of their density with pressure is usually negligible.

Chapter 5. Mass and Energy Analysis of Control Volumes

CHAPTER EIGHT P U M P I N G O F L I Q U I D S

CHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

Estimation of Flow Meter Losses

9. Pumps (compressors & turbines) Partly based on Chapter 10 of the De Nevers textbook.

Anemometry Anemometer Calibration Exercise

vector H. If O is the point about which moments are desired, the angular moment about O is given:

ABB Flowmeters Review of industrial processing flowmeters

Chapter 1: INTRODUCTION AND BASIC CONCEPTS. Thermodynamics = Greek words : therme(heat) + dynamis(force or power)

Ben Wolfe 11/3/14. Figure 1: Theoretical diagram showing the each step of heat loss.

Applied Fluid Mechanics

Water Circuit Lab. The pressure drop along a straight pipe segment can be calculated using the following set of equations:

SCHOOL OF CHEMICAL ENGINEERING FACULTY OF ENGINEERING AND TECHNOLOGY SRM UNIVERSITY COURSE PLAN

ME 4600:483 Lab Notes Revised 11/16/2015. Flow Measurement

Background Information for Use of Pitot Tube, Manometer, Hot Wires, and Hot Films

Lesson 10. Thermomechanical Measurements for Energy Systems (MENR) Measurements for Mechanical Systems and Production (MMER)

TOPICS. Density. Pressure. Variation of Pressure with Depth. Pressure Measurements. Buoyant Forces-Archimedes Principle

A drop forms when liquid is forced out of a small tube. The shape of the drop is determined by a balance of pressure, gravity, and surface tension

Amir Hossein Parvardi 1

SEM-2017(03HI MECHANICAL ENGINEERING. Paper II. Please read each of the following instructions carefully before attempting questions.

The FLIP Experiment: Testing the Relationship of Length of Upwelling Tubes to Maximize Upwelling Velocity

ME 201 Thermodynamics

Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018

Chapter 14. Lecture 1 Fluid Mechanics. Dr. Armen Kocharian

Understanding Hot-Wire Anemometry

Chapter Four Hydraulic Machines

Thermodynamic System. A thermodynamic system is a volume in space containing a quantity of matter that is being studied for thermodynamic analysis.

Transcription:

Venturi Example Given: A venturi is to be used to measure a 50 gpm flow of 70 F water in a 4-in ID pipe. Find: Select a throat diameter that provides Re d > 00,000 in the throat, and determine what differential pressure must be measured. Water Properties: µ = 6.58 10-4 lbm/ft-s =.37 lbm/ft-hr ρ = 6.3 lbm/ft 3

Venturi Example (Cont d) Sol n: Re d = ρvd/µ and, or: m& = m& = ρ Q 3 lbm gal min ft 6.3 50 60 0.13368 3 ft min hr gal m & =15,000 lbm Next, want Re in terms of mass flow rate: hr V d 4 m& ρ π m& = V = 4 ρ π d

Venturi Example (Cont d) Putting Re d in terms of mass flow rate... Re d = ρ ρ 4 m& π µ d Now can find d for various Re d (at highest mass flow rate): d = π d = π 4 m& Re d 4 m& d µ µ

Venturi Example (Cont d) For Re d = 00,000: lbm 4 15,000 d = hr = 0.336ft = lbm 00,000π.37 ft hr Since D = 4.00 in, we need a smaller d and should have no problem with Re d > 00,000. Choose d = inches for convenience. 4.03in

Venturi Example (Cont d) lbm 4 m& 4 15,000 Re hr d = = = π d µ lbm π ft.37 1 ft hr 403,000 Next we rearrange the YMCA Equation: Q = Y M C A ( P P ) 1 ρ

Venturi Example (Cont d) Solving for P = P 1 -P : P = Y ρ M Q C A For incompressible fluid (water), Y = 1. π ft 1 A = = 0.0181 ft 4

Venturi Example (Cont d) 4 π ft 1 A 1 = = 0.0877 ft 4 M = 1 1 A A 1 = 1 1 ( 0.0181 ) 0.0877 = 1.033

Venturi Example (Cont d) Correction factor C can be obtained from the obstruction meter handout or from text Table 10.1 (p. 80). Use Table 10.1 for a machined entrance, note we have β = d/d = in/4 in = 0.5, and Re D = 01,000 (calculation not shown). β, D and Re D > 10 5 fall within the given ranges, so the value C = 0.995 applies.

Venturi Example (Cont d) Inserting these values into the equation for P: P = lbm 6.3 3 ft 1 1.033 50 0.995 gal min lbf P = 597 ft = 0.13368 gal ft ( ) 0.0181 ft 3. 4.15 3 psi 1min 60s ft lbm lbf s

Rotameter Simple device for liquid and gas flow measurement This is a variable area meterthe rotameter uses a tapered tube with ball or float. As flow increases, float moves upward until fluid lift balances weight of float. Rotameter scale indicates fluid for which it is calibrated. Other fluids need correction.

Typical Rotameters

Rotameter Correction Rotameters are calibrated for only one fluid at given T and P (P not important for liquids). When the fluid is different or the conditions are different, the rotameter reading must be corrected to obtain the correct flow rate. Significant changes in use of rotameter yield loss in accuracy.

Rotameter Correction- Liquids For liquids, the correction equation is: Q Q act gage = ρ ρ b b ρ ρ act gage gage where Q gage is gage flow rate reading, Q act is corrected (actual) flow rate, ρ is density, subscript gage indicates fluid and conditions for which gage was calibrated, subscript act indicates actual fluid and conditions measured, and ρ b is the float density. 1 ρ ρ act 1

Rotameter Correction- Gases The correction equation for gases is: Q Q act gage = P gage P act T T gage gage where Q gage is gage flow rate reading, Q act is corrected flow rate, P is absolute pressure, T is absolute temperature, M is molecular weight, subscript gage refers to conditions for which rotameter was calibrated, and subscript act refers to actual measured conditions and fluid. act M M act 1

Spring-Loaded Rotameter The conventional rotameter uses the gravitational force, consequently it must be oriented vertically. Rotameters should be installed using a level to assure correct vertical orientation. Rotameters are available that oppose the flow drag force on the bob with a spring force. These can be oriented in any direction, but typically are less accurate.

Spring-Loaded Rotameter

Wet Test Meter A positive displacement gas flow meter. Meter is water filled. It counts the number of times a fixed water volume is displaced by gas. To get flow rate, meter is timed for some number of displaced volumes. Gas is exposed to liquid, so corrections must be made for water evaporation into the gas. Normally assume gas is saturated with water vapor before exiting the meter.

Wet Test Meter Correction Gas volume is measured at some T and P (T, P also must be measured), but rate is desired at standard T, P (standards vary...) Use ideal gas law: The dry gas flow rate is desired: m& dry gas P = RT std std Q std m& = PV & = RT P dry,m RT m = Q P RT m Q

Wet Test Meter Correction Thus, the standard dry gas volumetric flow rate is: Q std = P dry,m P Total measured pressure, P m is the sum of the dry gas partial pressure, P dry,m, and H O partial pressure, which is P sat at T m, so: std T T std m Q m P dry, m = P m P sat @ T m

Wet Test Meter Correction Putting this all together, the standard dry gas volumetric flow rate is: ( ) P P T Q = m sat @ Tm std std P T std m Q m

Hot Wire Anemometer A hot wire anemometer is a probe used to measure local velocity (like a pitot tube). It s a small, resistance wire, often platinum or tungsten, held at constant T by electric current. Heat loss from wire is proportional to both ha T and I R, and h is proportional to velocity, so measurement of I can be used to obtain velocity.

Hot Wire Construction

Hot Wire Anemometer

Turbine Meters A turbine meter is a small turbine inserted in a pipe so that all flow passes over it. The blade rotational frequency is sensed as a pulse rate by a magnetic pickup. Meter is calibrated so Q = f /K, where f is frequency and K is the flow coefficient. Typical K units: pulses/gal, pulses/liter, etc. Turbine meters have high accuracy, good transient response, and wide linear range.

Turbine Meter Assembly

Turbine Meter

Paddlewheel Meter Poor man s turbine meter- cheaper but less accurate. Partial insertion in flow.

Water Meter Some rate flow meters can integrate volumetric flow over time to get total volume (a totalizing meter). a water meter gives a positive displacement measurement of total volume of liquid passed through (rather than flow rate). Similar meters are used for measuring water usage, gasoline pumped, etc. Following is a nutating vane water meter.

Mass Flow Meter/Controller A mass flow meter is a gas flow instrument that is relatively insensitive to gas P, ρ and T. Based on relation: q= m& c T p The value of c p is known and relatively constant over a fairly broad T range. The value of q is measured as q = I R. The value of T is measured also, so the only unknown is m&

Mass Flow Meter The mass flow meter can be used as feedback to control a modulating valve, thus providing a mass flow controller. Mass flow meter works only on a single gas. Mass flow meters provide about ±1% accuracy at rated conditions and cost $100 to $000. The controller option adds ~$600 to cost.

Constant fractional bypass flow Mass flow meter schematic