COMPARISION OF FLOW ANALYSIS THROUGH A DIFFERENT GEOMETRY OF FLOWMETERS USING FLUENT SOFTWARE

Similar documents
COMPARISON OF CFD SIMULATION OF HOT AND COLD FLUID MIXING IN T-PIPE BY PLACING NOZZLE AT DIFFERENT PLACES

Experimental and CFD analysis of flow through venturimeter to determine the coefficient of discharge

Predictionof discharge coefficient of Venturimeter at low Reynolds numbers by analytical and CFD Method

Chapter 4 DYNAMICS OF FLUID FLOW

Prediction of Performance Characteristics of Orifice Plate Assembly for Non-Standard Conditions Using CFD

ABSTRACT I. INTRODUCTION

5 ENERGY EQUATION OF FLUID MOTION

Mass of fluid leaving per unit time

[Prasanna m a*et al., 5(6): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

CHAPTER 7 NUMERICAL MODELLING OF A SPIRAL HEAT EXCHANGER USING CFD TECHNIQUE

Lecture23. Flowmeter Design.

DESIGN & COMPUTATIONAL FLUID DYNAMICS ANALYSES OF AN AXISYMMETRIC NOZZLE AT TRANSONIC FREE STREAM CONDITIONS

Experiment (4): Flow measurement

CHAPTER 3 BASIC EQUATIONS IN FLUID MECHANICS NOOR ALIZA AHMAD

Fluid Mechanics. du dy

DEVELOPED LAMINAR FLOW IN PIPE USING COMPUTATIONAL FLUID DYNAMICS M.

[Ramya, 4 (12): December, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

CFD Analysis of High Temperature and High Velocity System: Plasma Torch

2 Internal Fluid Flow

Chapter Four fluid flow mass, energy, Bernoulli and momentum

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

ABSTRACT I. INTRODUCTION

Investigation of Flow Profile in Open Channels using CFD

EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER

04/01/1998 Developments in DP Flowmeters By Jesse Yoder

Experiment- To determine the coefficient of impact for vanes. Experiment To determine the coefficient of discharge of an orifice meter.

The Bernoulli Equation

Differential relations for fluid flow

Chapter 3 Bernoulli Equation

Fluid Dynamics Exercises and questions for the course

Computational fluid dynamics study of flow depth in an open Venturi channel for Newtonian fluid

FACULTY OF CHEMICAL & ENERGY ENGINEERING FLUID MECHANICS LABORATORY TITLE OF EXPERIMENT: MINOR LOSSES IN PIPE (E4)

Practical Analysis Of Turbulent Flow In A Pipe Using Computational Fluid Dynamics

FLOW MEASUREMENT IN PIPES EXPERIMENT

CEE 3310 Control Volume Analysis, Oct. 7, D Steady State Head Form of the Energy Equation P. P 2g + z h f + h p h s.

V/ t = 0 p/ t = 0 ρ/ t = 0. V/ s = 0 p/ s = 0 ρ/ s = 0

FLUID MECHANICS. Chapter 3 Elementary Fluid Dynamics - The Bernoulli Equation

CEE 3310 Control Volume Analysis, Oct. 10, = dt. sys

Modelling and Parametric fluid flow Analysis (CFD) of convergent nozzle used in pelton turbine

Lesson 37 Transmission Of Air In Air Conditioning Ducts

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

150A Review Session 2/13/2014 Fluid Statics. Pressure acts in all directions, normal to the surrounding surfaces

Computational Fluid Dynamics of Parallel Flow Heat Exchanger

Applied Fluid Mechanics

Applied Fluid Mechanics

CFD AND CONJUGATE HEAT TRANSFER ANALYSIS OF HEAT SINKS WITH DIFFERENT FIN GEOMETRIES SUBJECTED TO FORCED CONVECTION USED IN ELECTRONICS COOLING

Flowmeter Discharge Coefficient Estimation

UNIT I FLUID PROPERTIES AND STATICS

Where does Bernoulli's Equation come from?

CFD study for cross flow heat exchanger with integral finned tube

CFD ANALYSIS OF CD NOZZLE AND EFFECT OF NOZZLE PRESSURE RATIO ON PRESSURE AND VELOCITY FOR SUDDENLY EXPANDED FLOWS. Kuala Lumpur, Malaysia

Measurements using Bernoulli s equation

DESIGN AND CFD ANALYSIS OF A CENTRIFUGAL PUMP

COURSE NUMBER: ME 321 Fluid Mechanics I 3 credit hour. Basic Equations in fluid Dynamics

The effect of geometric parameters on the head loss factor in headers

MOMENTUM PRINCIPLE. Review: Last time, we derived the Reynolds Transport Theorem: Chapter 6. where B is any extensive property (proportional to mass),

Objectives. Conservation of mass principle: Mass Equation The Bernoulli equation Conservation of energy principle: Energy equation

Fluid Mechanics II. Newton s second law applied to a control volume

Head loss coefficient through sharp-edged orifices

Consider a control volume in the form of a straight section of a streamtube ABCD.

FLOW MALDISTRIBUTION IN A SIMPLIFIED PLATE HEAT EXCHANGER MODEL - A Numerical Study

I. To find the coefficient of discharge for vcnturi meter. 2. To find the coefficient of discharge for ori rice meter.

Throttling Characteristics of Multi-Hole Orifice in Multi Stage Assembly

6. The Momentum Equation

Modelling of dispersed, multicomponent, multiphase flows in resource industries. Section 3: Examples of analyses conducted for Newtonian fluids

Effect of radius ratio on pressure drop across a 90 bend for high concentration coal ash slurries

CE 204 FLUID MECHANICS

FE Exam Fluids Review October 23, Important Concepts

Analysis of Fully Developed Turbulent Flow in a AXI-Symmetric Pipe using ANSYS FLUENT Software

FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER

PROBLEM SET 6. SOLUTIONS April 1, 2004

Detailed Outline, M E 320 Fluid Flow, Spring Semester 2015

Numerical Modelling For Hydro Energy Convertor: Impulse Turbine

equation 4.1 INTRODUCTION

Lesson 6 Review of fundamentals: Fluid flow

Page 1. Neatly print your name: Signature: (Note that unsigned exams will be given a score of zero.)

A Comparative Analysis of Turbulent Pipe Flow Using k And k Models

CFD Analysis for Thermal Behavior of Turbulent Channel Flow of Different Geometry of Bottom Plate

BERNOULLI EQUATION. The motion of a fluid is usually extremely complex.

CALCULATION OF COEFFICIENT OF DISCHARGE OF ORIFICE PLATE AND FLOW NOZZLE

2Dimensional CFD Simulation of Gas Fired Furnace during Heat Treatment Process

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

V (r,t) = i ˆ u( x, y,z,t) + ˆ j v( x, y,z,t) + k ˆ w( x, y, z,t)

Therefore, the control volume in this case can be treated as a solid body, with a net force or thrust of. bm # V

Experiment No.4: Flow through Venturi meter. Background and Theory

EVALUATION OF THERMAL PERFORMANCE OF CONE SHAPED HELICAL COIL HEAT EXCHANGER BY USING CFD ANALYSIS

VENTURIMETER EXPERIMENT

vector H. If O is the point about which moments are desired, the angular moment about O is given:

Candidates must show on each answer book the type of calculator used. Only calculators permitted under UEA Regulations may be used.

CHAPTER THREE FLUID MECHANICS

Optimization of Shell & Tube Heat Exchanger by Baffle Inclination & Baffle Cut

Modeling and simulation of Convergent-Divergent Nozzle Using Computational Fluid Dynamics

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

MASS, MOMENTUM, AND ENERGY EQUATIONS

For example an empty bucket weighs 2.0kg. After 7 seconds of collecting water the bucket weighs 8.0kg, then:

Fluid Mechanics c) Orificemeter a) Viscous force, Turbulence force, Compressible force a) Turbulence force c) Integration d) The flow is rotational

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

Stream Tube. When density do not depend explicitly on time then from continuity equation, we have V 2 V 1. δa 2. δa 1 PH6L24 1

INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 5, ISSUE 09, SEPTEMBER 2016 ISSN

Transcription:

COMPARISION OF FLOW ANALYSIS THROUGH A DIFFERENT GEOMETRY OF FLOWMETERS USING FLUENT SOFTWARE T.Sridevi 1, Dhana Sekhar 2, V.Subrahmanyam 3 1 M.Tech Scholar, Department of Mechanical Engineering, Kakinada Institute of Technology and Science, Divili, Andhra Pradesh, India 2 Assistant Professor, Department of Mechanical Engineering, Kakinada Institute of Technology and Science, Divili, Andhra Pradesh, India 3 Ph.D Scholar, Department of Mechanical Engineering, J.N.T.U Kakinada, Andhra Pradesh, India Abstract Flow meter or orifice meter are widely used in industry for flow measurement. A pressure loss takes place in the pipe line due to the restriction present in it. An amount of pressure loss occurs due to the thickness, shape and diameter of the plate. In the present paper, fluent software was used to plot the characteristics of the flow and gambit software was used to design the 2D model. Two phase computational fluid dynamics calculations, using k-epsilon model were employed. This simulation gives the values of pressure, velocity and turbulence contour at various sections in which water as a media. The flow analysis is done on various types of flow meters namely round plate, nozzle, short tube and borda type plates. The numerical results were validated against experimental data from the literature and were found to be good agreement. Keywords: Gambit, Fluent, K-Epsilon model, restriction. --------------------------------------------------------------------***---------------------------------------------------------------------- 1. INTRODUCTION Measuring the mass flow rate of a fluid running through a pipe is very important in many industries. Among the available flow metering devices, pressure differential based devices extremely applicable due to their simple design and low cost. A number of primary elements belonged to this class namely concentric orifice, eccentric orifice, wedge flow meter, venturi nozzle, and venturi meter. The selection of flow meter for given application depends upon the relative importance of measurement problems. Hence, it remains a matter of individual judgment based on engineer s knowledge and type of application. Based upon the simple principle of effect of pressure and velocity variations caused by reduction of the available area for flow in pipe. The flow meters are supplied with the discharge coefficient and the installation procedure. The discharge coefficient is defined as the ratio of actual flow to the theoretical flow. It is obtain from experimental results after regression, where in experiment are conducted in controlled condition of undistributed symmetric free velocity profile in the upstream of orifice. geometry is done in the GAMBIT software, a fine meshing is done by using successive ratio and later given the boundary conditions for the geometry and for the media. This file imported into Fluent software and has given the input values like velocity, mass flow rate, pressure, temperature etc., Two dimensional geometry was used to study the flow in the flow meters for solving the mass, momentum, and energy equations. The phase velocities were defined at the inlet boundary of the flow meters. The к-ε turbulence models with standard wall functions were used to solve the problems. The gravitational acceleration of 9.81 m/s 2 in downward flow direction was used. Hence it is very important to understand the flow pattern of orifice meter to further improvement in its performance in terms of flow measurement with better accuracy and sensitivity. 2. DETAILED PROCEDURE The current study used FLUENT, to solve the balance equation using control volume approach. These equations are solved by converting the complex partial differential equations into simple algebraic equations. The simple Fig-2.1: diagram of type orifice meter. Two dimensional model is done for four different geometry namely round plate, nozzle, short tube and borda type in gambit software and simulations is done in steady state with inlet velocity of 3m/sec and at room temperature. Results Volume: 03 Issue: 08 Aug-2014, Available @ http://www.ijret.org 141

are obtained for velocity, pressure and turbulence and graphs are plotted. 3. GEOMETRY DETAILS The geometry was done in the GAMBIT with measurements, pipe diameter is 60mm, and thickness of the plate is 5mm and length of the pipe 150 mm. Defining required boundaries like inlet, outlet and wall of the geometry and mesh under tetrahedron. Defining the boundary conditions for the media as the water. The figure shows the geometry of the fluid flow through flow meters. Fig- 3.4: mesh geometry of nozzle type. 4. SOLUTION STRATEGY AND CONVERGENCE The simulation is done in the FLUENT based upon the governing equations. The steps followed in the fluent are define Model, define Material, define cell zone, boundary condition, solve, iterate, and analyze results. The governing equations used to solve this problem as below. Fig- 3.1: mesh geometry of round type. 4.1. Continuity Equation Continuity Equation also called conservation of mass. Consider fluid moves from point 1 to point 2. The overall mass balance is Input output = accumulation Assuming that there is no storage, Mass input = mass output. However, as long as the flow is steady (time-invariant), within this tube, since, mass cannot be created or destroyed then the above equation. Fig- 3.2: mesh geometry of short tube. According to continuity equation, the amount of fluid entering in certain volume leaves that volume or remains there and according to momentum equation tells about the balance of the momentum. The momentum equations are sometimes also referred as Navier-Stokes (N-S) equation. They are most commonly used mathematical equations to describe flow. The simulation is done based on the N-S equations and then K-Epsilon model. Fig- 4.1: continuity equation. Fig- 3.3: mesh geometry of borda type. Volume: 03 Issue: 08 Aug-2014, Available @ http://www.ijret.org 142

m 1. = m 1. dm 1 dt = dm 1 dt (1) (2) We have ρ da u du = dp da ρ g da dz { ρ da } dp/ ρ + udu + dz g = 0 --------- Euler s equation of motion. ρa 1 u 1 = ρa 2 u 2 (3) A 1 v 1 = A 2 v 2 (4) 4.2. Momentum Equation and Bernoulli Equation: It is also called equation of motion.according to Newton s 2nd law (the time rate of change of momentum of the fluid particles within this stream tube slice must equal to the forces acting on it). F = mass x acceleration Consider a small element of the flowing fluid as shown below, Let da : cross-sectional area of the fluid element, dl : Length of the fluid element, dw : Weight of the fluid element, u : Velocity of the fluid element, P : Pressure of the fluid element. Assuming that the fluid is steady, non-viscous (the frictional losses are zero) and incompressible (the density of fluid is constant). The forces on the cylindrical fluid element are, 1. Pressure force acting on the direction of flow (PdA). 2. Pressure force acting on the opposite direction of flow [(P+dP)dA]. 3. A component of gravity force acting on the opposite direction of flow (dw sin θ). Hence, Total force = gravity force + pressure force The pressure force in the direction of low Fp = PdA (P+dP) da = dpda (5) The gravity force in the direction of flow Bernoulli s equation could be obtain by integration the Euler s equation. dp/ ρ + udu + dz g = constant. P/ ρ + u2/2 + z g = constant. ΔP/ ρ + Δu2/2 + Δz g = 0 -- Bernoulli s equation. 4.3. Kappa-Epsilon Model The K-epsilon model is most commonly used to describe the behavior of turbulent flows. It was proposed by A.N Kolmogrov in 1942, then modified by Harlow and Nakayama and produced K-Epsilon model for turbulence. The Transport Equations for K-Epsilon model are for k, t ρk + t ρku i (8) For, (9) t ρε + t ρεu i = μ + μ t x j σ k ρε Y k +S k = x j ε + C 1ε μ + μ t σ k k x j ε x j + P k + P b k P k + C 3ε P b C 2ε ρ ε2 k + +S ε Realizable k-epsilon model and RNG k-epsilon model are some other variants of K-epsilon model. K-epsilon model has solution in some special cases. K-epsilon model is only useful in regions with turbulent, high Reynolds number flows. Fg = dw sin θ {W=m g = ρ da dl g}. = ρ g da dl sin θ {sin θ = dz / dl}. = ρ g da dz. (6) The net force in the direction of flow F = m a {m = ρ da dl. = ρ da dl a. = ρ da u du. (7) Volume: 03 Issue: 08 Aug-2014, Available @ http://www.ijret.org 143

5. RESULTS 5.1 Results of Round Type Flow Meter Fig- 5.1.1: velocity contours. Chart-5.1.1: Pressure-position. Fig- 5.1.2: pressure contours. Chart-5.1.2: Velocity-position. Fig- 5.1.3: turbulent contours. Chart-5.1.3: turbulence-position. Volume: 03 Issue: 08 Aug-2014, Available @ http://www.ijret.org 144

Table-5.1.1: results of flow analysis. s.no parameters Min. Max. 1 Pressure(Pascal) -26180.56 7727.657 2 Velocity(m/s) 0 5.208365 3 Turbulent(m 2 /s 2 ) 0.054719 4.5418 Table-5.1.2: results of mass flow rate. Mass Flow Rate (kg/s) Interior -5569.2096 Inlet 179.67601 Outlet -179.67601 Wall 0 5.2 Results of Short Tube Type Flow Meter Fig- 5.2.3: Turbulent Contours. Fig- 5.2.1: Pressure Contours. Chart-5.2.1: Pressure-Position. Chart-5.2.2: Velocity-Position. Fig- 5.2.2: Velocity Contours. Volume: 03 Issue: 08 Aug-2014, Available @ http://www.ijret.org 145

Chart-5.2.3: Turbulence-Position. Fig- 5.3.2: Velocity Contours. Table-5.2.1: results of flow analysis. s.no parameters Min. Max. 1 Pressure(Pascal) -51817.77 9904.737 2 Velocity(m/s) 0 6.918732 3 Turbulent(m 2 /s 2 ) 0.00050 7.705388 Table-5.2.2: results of mass flow rate. Mass Flow Rate (kg/s) Interior 1169.6085 Inlet 179.67601 Outlet -179.67601 Wall 0 5.3 Results of Borda Type Flow Meter: Fig- 5.3.3: Turbulent Contours. Fig- 5.3.1: Pressure Contours. Chart-5.3.1: Pressure-Position. Volume: 03 Issue: 08 Aug-2014, Available @ http://www.ijret.org 146

5.4 Results of Nozzle Type Flow Meter: Chart-5.3.2: Velocity-Position. Fig- 5.4.1: Pressure Contours. Chart-5.3.3: Turbulence-Position. Table-5.3.1: results of flow analysis. s.no parameters Min. Max. 1 Pressure(Pascal) -47866.36 8441.355 2 Velocity(m/s) 0 6.78514 3 Turbulent(m 2 /s 2 ) 0.0006724 7.499114 Fig- 5.4.2: Velocity Contours. Table-5.3.2: results of mass flow rate. Mass Flow Rate (kg/s) Interior -2036.7402 Inlet 179.67601 Outlet -179.67601 Wall 0 Fig- 5.4.3: Turbulent Contours. Volume: 03 Issue: 08 Aug-2014, Available @ http://www.ijret.org 147

3 Turbulent(m 2 /s 2 ) 0.028088 10.4724 Table-5.4.2: results of mass flow rate. Mass Flow Rate 6. CONCLUSIONS (kg/s) Interior 1209.1305 Inlet 179.67601 Outlet -179.67601 Wall 0 Chart-5.4.1: Pressure-Position. The flow pattern through an flow meter has been simulated for four different models, successfully, using CFD technique using fluent 6.3.26 solver. A good agreement between experimental data and CFD predictions flow patterns, pressure profile, velocity profile, turbulence model parameter and mass flow rate. It is also concluded that the CFD technique can be used as an alternative and cost effective tool to wards replacement requirement for estimating mass flow rate. The design of a flow meter with a provision to track vena contracta using CFD technique has been explained. As per the application, selection of flow meters can be done and the behaviours of the flow pattern are plotted for four different models. REFERENCES Chart-5.4.2: Velocity-Position. Chart-5.4.3: Turbulence-Position. Table-5.4.1: results of flow analysis. s.no parameters Min. Max. 1 Pressure(Pascal) -60693.42 10006.32 2 Velocity(m/s) 0 9.59358 [1]. Singh, Rajesh Kumar, Singh, S.N., Seshadri V.(2010). CFD prediction of the effects of the upstream elbow fittings on the performance of cone flowmeters. Flow measurements and instrumentation,21,88-97. [2]. Patankar, S.V. and Spalding, D.B., 1972. A calculation procedure for heat, mass and momentum transfer in three dimensional parabpara flows. International journal of heat and mass transfer, Vol. 15,pp. 1787-1806. [3]. Singh, R.K., Singh, S,N. and Seshandri, V., 2010. Performance evaluation of orifice plate assemblies under non-standard conditions using cfd. Indian Journal of Engineering And Materials Sciences, Vol.17, pp.397-406. [4]. Seshadri, V., Singh, S.N., Pramod K.B., 2002. Performance Charateristics of Wedge Flow Meter using CFD, Journal of Computational Fluid Dynamics, vol.11,3,279-284. [5]. Gerald., L. Morrison, Robert, E. D., Jr.Eric J.B.,1992. Installation Effect upon Flow meters, Journal of flow measurement and Instrumentation, Vol-3, No-2, 89-93. [6]. Teyssedou A., onder E.N and Tye P.(2005) Air-water counter-current slug flow data in vertical-to-horizontal pipe containing orifice type obstructions. International journal of multiphase Flow, 31,771-792. [7]. Quinn W.R. Experimental study of the near field and transition region of a free jet issuing from a sharp-edged elliptic plate. European journal of Mechanics B-Fluids. [8]. Qing M., Jinghui Z.,yushan L., Quan D. (2006). Experimental studies of orifice-induced wall pressure Fluctuations and pipe vibration. International Journal of Pressure Vessels and piping. Volume: 03 Issue: 08 Aug-2014, Available @ http://www.ijret.org 148

[9]. Turian R.M., Ma T-W., Hsu F-L.G and sung D.- j.(1998). Flow of concentrated non Newtonian slurries:1. Frictional loss through straight pipe. International journal of Multiphase flow, 24, 225-242. 8. BIOGRAPHIES: T.Sridevi completed schooling from St.Joseph's girls high school in guntur with 73% marks. Completed intermediate from Vidwan Junior College in Guntur with 75% marks. completed B.Tech Degree from J.N.T.U Campus.Hyd with 68%. Now I am pursuing M.Tech from Kakinada Institute of Technology and Science,Tirupathi(V),Divili, East Godavari Dist, A.P, India. Mr. Y.Dhana Sekhar completed his B.Tech from A.S.R.College of Engineering and M.Tech from Godavari Institute of Technology &Engineering, Rajahmundry. He has 2 years of Industrial and 2years of teaching experience. Now he is working as Asst. Professor and HOD of Mechanical Engineering in Kakinada Institute of Technology & Science, Divili and doing research in Thermal Engineering. Mr. V.Subrahmanyam working as Assoc. Professor and Head of Mechanical Engineering Department in KITS-Divili Engineering college, Andhra Pradesh, India. He has 15 years of teaching experience in various reputed engineering colleges. He guided so many B.Tech and M.Tech projects. He has three publications in reputed international journals. He is doing research in Nano- Technology and Thermal Engineering. Volume: 03 Issue: 08 Aug-2014, Available @ http://www.ijret.org 149