THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer, analogue output or option RS-485 Measure high accuracy temperature & humidity, reaction quickly, the sensor can work well after temporary condensation, long term stable in high humidity environment Process temp. : up to 00, S.S. probe proof pressure : 0 bar, metal connector : installation repeatedly Switch multifunction physical quantities:[%rh] [ ] [mbar] [g/kg] [g/m3] [kj/kg] Industrial Process Monitoring / Air Conditioning / Environmental entilation Control Buildings, factories, hospitals, clean rooms, laboratories, weather stations Environmental monitoring Storage rooms, environmental chambers, greenhouses, mushroom farms Semiconductor, electronics, paper, printing, textiles, steel and iron Industry, food, chemical, pharmaceutical, biotechnology industry Calibration physical quantities, measuring range, analogue output, station, etc Free calibration software : data logger / record 65535 datas / charts www.eyc-tech.com EYC THM80X Series P/7 ERSION : 06/0/0
Input input type Output output signal connection modbus display type display range height of character load resistance output calibration ( ZERO & SPAN ) response time t90 ( temp. at +5 C ) Accuracy ( at +5 C ) temperature humidity ( 0... 90 % ) humidity ( 90... 00 %) thermal sensitivity temperature error Capacitive Humidity Sensor & PT 00Ω A class 0... 0 / 4... 0 / 0... / 0... 5 / 0... 0 3-wire option RS-485 ( programmable ) and analogue output LCD Module with back light, double line character upon request, one decimal place 5.55mm current output : max. 500Ω / voltage output : min. 0KΩ software;keybord S.S. metal grid filter with mesh );< 30S( sintered filter ) ± 0.5 C ± 0.00 C x actual nonlinear error : ±. % RH hysteresis error : ± 0.8 % RH repeatability error : ± 0.4 % RH ± % RH 0.05 % RH / C Factory Uncertainty ( at +5 C ) temperature uncertainty 0.4 C humidity uncertainty 0.4 % RH ( >0 % ~ 0 % ) 0.65 % RH ( >0 % ~ 90 % ) 0.97 % RH ( >90 % ~ 98 % ) t Environment media measured working temp. for housing working humidity for housing working temp. for housing with display working temp. for probe storage temp. proof pressure for S.S. probe air -0... + 80 C 0... 95 % ( non-cond. ) -0... +60 C wall type:-... 80, duct type:-... + 0 ; remote type:-... + 00-5... + 60 C 0 bar Certification CE certification EN 636- : 006 EN 636-- : 006 Emissions EN 550 : 009/A : 00 Immunity IEC 6000-4- : 008 IEC 6000-4-3 : 006 / A : 007 / A : 00 IEC 6000-4-8 : 009 Electrical power supply current consumption electrical connection protect degree electric protection installation housing probe cable option weight 8~35DC / ~30AC DC 4 : 60 / DC : 0 AC 4 : / AC : 30 M - 4 PIN metal connector with m cable or terminal ( metal cable gland ) body : IP67;probe : IP 0 Polarity protection over-voltage short-circuit metal fitting thread aluminum alloy SUS 304 teflon metal connector / metal mounting flane / shield(outdoor) THM80 : 455g / THM80 : 5g / THM803 : 635g physical quantity THM80 inddor THM80 duct THM803 remote temperature ( T ) -~+80 -~+0 -~+00 humidity ( H ) 0~00%RH dew point ( D ) -~+60 frost Point ( F ) -~0 wet-bulb temp. ( W ) 0~00 vapor pressure ( E ) 0~00mbar mixture ratio ( R ) absolute humidity ( ) specific enthalpy ( S ) 0~999g/kg 0~700g/kg 0~800kj/kg Use Thunder 500 humidity generator, MBW473 dew point mirror, Laboratory level facility to produce products, and automatic QC inspection sheet printing and factory report. Beside temp. & dew point, other physical quantities range as default setting www.eyc-tech.com EYC THM80X Series P/7 ERSION : 06/0/0
According to IEC 698 and ISO 705 standard to measuring 3-cycle curve. As the charts result, accuracy of test sample match with accuracy chart of humidity generator + dew point mirror 00 00 Actual humidity ( % ) 80 60 0 0 0 0 0 30 50 60 70 80 90 00 ascending line descending line total average line standard line humidity ( % ) 90 80 70 60 50 30 0 0 0 06/9/ 05:58:4 06/9/ 09:58:38 0:59:38 05:59:8 09:59:8 0:58:48 05:59:38 0:00:8 06/9/4 0:59:44 06/9/4 06:00:44 humidity generator + dew point mirror THM80X test sample THM80X test sample According to IEC 698 and ISO 705 standard to measure nonlinear error error ( % ) hysteresis ( % ) repeatability error ( % ).50.00 0.50 0.00-0.50 -.00 -.50.50.00 0.50 0.00-0.50 -.00 -.50.50.00 0.50 0.00-0.50 -.00 -.50 0 0 0 30 50 60 70 80 90 00 hysteresis error 0 0 0 30 50 60 70 80 90 00 repeatability error 0 0 0 30 50 60 70 80 90 ascending line descending line total average line average line Max. ascending line descending line www.eyc-tech.com EYC THM80X Series P3/7 ERSION : 06/0/0
type installation wall duct remote physical quantity output temperature humidity dew point frost-point web-bulb temperature vapor pressure mixture ratio absolute humidity speific enthalpy RS-485 ( default temp. ) physical quantity scale 0... 50 0... 80 0... 00 0... 0 0... 80 0... 00-0... + -... +60 -... +0 -... ~+80 -... +00-70... +80 as physical quantity measuring range list ( H, F, W, E, R,, S ) special range signal output 4... 0 0... 0 0... 0 0... 5 0... RS-485 physical quantity output temperature humidity dew point frost-point web-bulb temperature vapor pressure mixture ratio absolute humidity speific enthalpy RS-485 ( default temp. ) physical quantity scale 0... 50 0... 80 0... 00 0... 0 0... 80 0... 00-0... + -... +60 -... +0 -... ~+80 -... +00-70... +80 as physical quantity measuring range list ( H, F, W, E, R,, S ) special range signal output 4... 0 0... 0 0... 0 0... 5 0... RS-485 display no yes electric connector M6 metal cable gland M metal connetor filter S.S. metal grid filter with mesh sintered filter remote cable ( max. length : 0 m ) THM80 m TEFLON cable 5 m TEFLON cable other length option / other request other request ( quote as demand ) RS-485 + analogue 3 T 48 H 00 D N S 3 T H D F W E R S N 30 38 4 48 47 3 4 6 8 0 49 00 YY 6 7 8 9 T H D F W E R S N 30 38 4 48 47 3 4 6 8 0 49 00 YY 6 7 8 9 X D N M M S 5 W U EYC THM80X Series P4/7 ERSION : 06/0/0
unit : mm M type (M-4PIN metal connector RS-485 or analogue M type (M-8PIN metal connector) RS-485+analogue N type (M6 cable gland) RS-485+analogue 4..5 7. THM80 ( wall ) THM80 ( duct ) THM803 ( remote ) 34mm 04mm 34mm 04mm 9.55mm 80mm 95.54mm M screw thread ( metal fitting thread ) or M6 metal cable gland 80mm 95.54mm Ø mm M screw thread ( metal fitting thread ) or M6 metal cable gland 4mm M screw thread ( metal fitting thread ) or M6 metal cable gland 50mm 3mm M 型 3mm 50mm length as request gauge : 5.3mm Ø mm 63.3mm N 型 S.S. metal grid filter with mesh or S.S. sintered filter Ø mm EYC THM80X Series P5/7 ERSION : 06/0/0
brown 4black white 3 blue 8~35 DC & ~30 AC cc 8~35 DC & ~30 AC M connector 4P terminal M type ( 4P ) N type black white brown 4 3 blue M type ( 4P ) 8~35 DC & ~30 AC cc Tx Rx 8~35 DC & ~30 AC when output of ordering code is RS-485 ( without analogue ), RS-485 diagram of default setting is M type. N type cc 8~35 DC & ~30 AC brown black 7 white 3 blue 8 6 5 4 yellow green RS485 gray Tx Rx 8~35 DC & ~30 AC M 型 ( 8P ) N 型 ( M6 ) EYC THM80X Series P6/7 ERSION : 06/0/0
SCADA USB CR-800 USB to RS-485 Converter Device. PC. RS-485 to USB Converter 3. power supply 4. UI software option converter: CR-800 EYC free programmable software http://www.eyc-tech.com/download/download49.html HMI transmitter PLC EYC THM80X Series P7/7 ERSION : 06/0/0