AppNote 8/2009. Fragrance Profi ling of Consumer Products using a Fully Automated Dynamic Headspace System KEYWORDS ABSTRACT

Similar documents
AppNote 6/2012. Flavor and Fragrance Analysis of Consumer Products - Dynamic Headspace Compared to Some Traditional Analysis Approaches KEYWORDS

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

AppNote 8/2008. A New Purge Tool for Use with Automated Headspace Analysis KEYWORDS ABSTRACT

AppNote 14/2012. Thermal Gravimetric Analysis/Mass Spectrometry Simulation using the GERSTEL Automated Pyrolyzer KEYWORDS ABSTRACT

AppNote 3/2014. Analysis of Aroma Compounds in Edible Oils by Direct Thermal Desorption GC/MS using Slitted Microvials KEYWORDS ABSTRACT

AppNote 1/2007. Automated Dynamic Headspace Sampling using Replaceable Sorbent Traps KEYWORDS ABSTRACT

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

TechNote 5/2002 KEYWORDS ABSTRACT. SBSE, Twister, Thermal Desorption

AppNote 4/1998. New Developments in Multi-Dimensional Capillary Gas Chromatography KEYWORDS ABSTRACT

AppNote 15/2012. Large Volume Injection with Solvent Venting - Application to Trace Detection of Analytes in Water INTRODUCTION

AromaOffi ce: Application of a Novel Linear Retention Indices Database to a Complex Hop Essential Oil

Off-gassing of Rubber Particles Used for Athletic Fields using Automated Dynamic Headspace Sampling

AppNote 2/1996. Andreas Hoffmann Gerstel GmbH & Co.KG, Eberhard-Gerstel-Platz 1, D Mülheim an der Ruhr, Germany

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances KEYWORDS

AppNote 8/2011 KEYWORDS ABSTRACT INTRODUCTION

Analysis of Food Samples using Thin Film Solid Phase Microextraction (TF-SPME) and Thermal Desorption GC/MS

AppNote 2/2002. Discrimination of Soft Drinks using a Chemical Sensor and Principal Component Analysis KEYWORDS ABSTRACT

AppNote 2/2001. Stir Bar Sorptive Extraction: Enhancing Selectivity of the PDMS Phase KEYWORDS ABSTRACT

AppNote 3/2007 KEYWORDS INTRODUCTION. Beverage, Detector, Headspace, Quality Control

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to En vi ron men tal Aqueous Samples INTRODUCTION

Thermal Desorption Unit TDU

AppNote 1/2004. Use of a Mass Spectral Based Chemical Sensor to Discriminate Food and Beverage Samples: Olive Oils and Wine as Examples KEYWORDS

AppNote 8/2002 KEYWORDS ABSTRACT. Electronic Nose, Fast GC, Headspace Analysis, Chemometrics,

AppNote 5/2002. Characterization of a Mass Spectrometer based Electronic Nose for Routine Quality Control Measurements of Flavors KEYWORDS ABSTRACT

AppNote 10/2012. Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages KEYWORDS

AppNote 8/2000. Volatile Organic Compounds from Adhesives and their Contribution to Indoor Air Problems KEY WORDS ABSTRACT

AppNote 2/2004. Analysis of Packaging Materials using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

AppNote 1/2011 KEYWORDS ABSTRACT

AppNote 6/2010. part a. Alternative Procedure for Extraction and Analysis of PAHs in Seafood by QuEChERS-SBSE-GC-MS KEYWORDS ABSTRACT

AppNote 9/2012. Solid Phase Micro-Extraction (SPME) Coupled with Selectable 1 D/ 2 D GC-MS for the Determination of Food Product Flavors KEYWORDS

AppNote 4/2005. A Selectable Single or Multidimensional. Fraction Collection and Dual Detection for Trace Analysis of Complex Samples KEYWORDS

AppNote 2/1998. Direct Injection of Distilled Spirits with PTV Matrix Removal: The Perfect Splitless Injection? KEYWORDS INTRODUCTION

AppNote 7/2014. Automating Liquid-Liquid Extractions using a Bench-top Workstation KEYWORDS ABSTRACT. Sample Preparation, Lab Automation, LC/MS/MS

AppNote 3/1998 KEYWORDS ABSTRACT. Beverage, Food & Flavor, PTV, Large Volume Injection, Headspace, Thermal Desorption.

AppNote 8/2012. Rapid Automated Extraction and Confi rmation of Buprenorphine and Norbuprenorphine in Urine by DPX-LC/MS/MS KEYWORDS ABSTRACT

AppNote 3/2012. Rapid Automated Screening of Extractable Compounds in Materials for Food Packaging, Medical or Technical Purposes KEYWORDS ABSTRACT

AppNote 2/2007. Automated Solid Phase Microextraction using the GERSTEL MPS Prepstation and MAESTRO Software KEYWORDS ABSTRACT

AppNote 6/2014. Automated Online Desorption and Analysis of DNPH Derivatives of Airborne Aldehydes and Ketones KEYWORDS ABSTRACT

AppNote 2/2012. Determining Phenolic Compounds in Whisky using Direct Large Volume Injection and Stir Bar Sorptive Extraction KEYWORDS ABSTRACT

AppNote 7/2002. Classifi cation of Food and Flavor Samples using a Chemical Sensor KEYWORDS ABSTRACT

AppNote 5/2001. The Analysis of the Bitter and Other Flavour Compounds in Beer and Wort by Stir Bar Sorptive Extraction (SBSE) Followed by HPLC

AppNote 2/2013. A High Throughput Automated Sample Preparation and Analysis Workfl ow for Comprehensive Toxicology Urine Screenings using LC/MS/MS

AppNote 1/2013. Determination of Barbiturates and 11-Nor-9-carboxy- 9 -THC in Urine using Automated Disposable Pipette Extraction (DPX) and LC/MS/MS

AppNote 12/2012. Comparison of EG-Silicone-SBSE and Derivatization-PDMS-SBSE for the Analysis of Phenolic Compounds and Off-fl avors in Water KEYWORDS

AppNote 12/2008 KEYWORDS ABSTRACT

KEYWORDS ABSTRACT AppNote 6/2002

GERSTEL MultiPurpose Sampler MPS. Versatile autosampler and sample preparation robot

Selective Sample Enrichment of Gaseous Samples using a Cooled Injection System: Trace Determination of Sulphur Components in Natural Gas

AppNote 7/2005. Detection of Packaging Emissions using a Flexible Headspace Sampler Combined with a Multi Sensor System and a Separation Unit KEYWORDS

AppNote 11/2012. Fully Automated Analysis of Doping Substances in Equine Urine by Disposable Pipette Extraction (DPX) coupled to GC/QqQ-MS KEYWORDS

AppNote 3/2011. Using Three Types of Twister Phases for Stir Bar Sorptive Extraction of Whisky, Wine and Fruit Juice KEYWORDS ABSTRACT

Headspace Technology for GC and GC/MS: Features, benefits & applications

AppNote 5/1994. The Use of a Multi Purpose Sampler for Headspace GC-MS Analysis of Volatile Organic Compounds in Human Urine

AppNote 2/1996. Andreas Hoffmann Gerstel GmbH & Co.KG, Aktienstrasse , D Mülheim an der Ruhr, Germany

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances

Determination of Formaldehyde and VOCs in Wood-based Products using an Automated Micro-Scale Chamber

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

GERSTEL Thermal Desorption System TDS 3 The GERSTEL TDS 3 is a flexible multi-functional thermal desorption system for highly sensitive and accurate d

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

AppNote 2/1999. Automated Sample Fractionation and Analysis Using a Modular LC-GC System

AppNote 8/2001 KEYWORDS ABSTRACT. PAH, SPME, SBSE, GERSTEL Twister, Thermal desorption, GC-MS, PCB

AppNote 7/2013. Comprehensive Automation of the SPE- GC/MS Analysis of Opioids, Cocaine and Metabolites from Serum and Other Matrices KEYWORDS

Analysis of Fast Moving Consumer Goods (FMCG) using GCMS with static and dynamic headspace (HS)

AppNote 2/2015 KEYWORDS ABSTRACT

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques

AppNote 6/2010. part b. High Throughput Method for the Determination of PAHs in Seafood by QuEChERS-SBSE-GC-MS SCOPE PRINCIPLE

Application. Gas Chromatography February Introduction

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Dynamic headspace (DHS) technique: set-up and parameter control for GC/MS analysis of odorant formulations

Determination of volatiles in Food sample preparation strategies and techniques Dr Kathy Ridgway

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Separation and Characterization of Indian and Australian Sandalwood Oils

Low-Level Sulfur Compounds in Beer by Purge and Trap with a Pulsed Flame Photometric Detector (PFPD)

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Determination of Volatile Substances Proof of Food Adulteration

AppNote 7/1994. Friedhelm Rogies, Andreas Hoffmann Gerstel GmbH & Co.KG, Aktienstrasse , D Mülheim an der Ruhr, Germany

GC Application Note. Dilution/standard addition: Efficient and traceable.

Encapsulated Recyclable Porous Materials: An Effective Moisture-

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Application Note 032

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

Determination of 59 potential Allergens in Perfumes by twin-line fast GCMSMS

PAL SPME Arrow The Better SPME

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

PAL SPME Arrow The Better SPME

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

Study of Residual Solvents in Various Matrices by Static Headspace

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles

Disadvantage: Destructive Technique once analyzed by GC, the sample is lost

Transcription:

AppNote 8/009 Fragrance Profi ling of Consumer Products using a Fully Automated Dynamic Headspace System Andreas Hoffmann, Oliver Lerch Gerstel GmbH & Co. KG, Eberhard-Gerstel-Platz, D-447 Mülheim an der Ruhr, Germany Volker Hudewenz drom fragrances international GmbH & Co. KG, Oberdiller Str. 8, D-806 Baierbrunn, Germany KEYWORDS Extraction methods, stability testing, quality control, market observation ABSTRACT Accurate qualitative and quantitative analysis of perfumed or flavored products is essential to the flavor and fragrance industry. Especially when unknown samples need to be analyzed traditional methods of GC analysis often lead to only vague results and often require time consuming and cumbersome sample preparation techniques such as solvent extraction (liquid/liquid, Soxhlet, Likens-Nickerson). The technique of dynamic headspace requires minimal sample preparation, and significantly reduces overall analysis time while also improving data quality. In this work, the dynamic headspace technique is applied to different types of consumer products. The analysis of neat perfume oil is compared with that of consumer products containing the same oil.

INTRODUCTION For consumers the odor of a product is a very important parameter for the overall perception and acceptance. Therefore it is always of interest to have the analytical means to control and/or analyze the volatile fraction of these products. Currently, the most commonly used methods for analyzing fragrances from market products are the SPME technique and SDE (simultaneous distillation/ extraction). These techniques both have certain disadvantages. The SDE technique is quite timeconsuming and also some polar and/or semi-volatile compounds can be lost during sample preparation. Using the SPME technique, the time factor is improved, however often the selectivity and limited capacity of the phase results in a distortion of the results when compared to the actual concentration levels of individual fragrance compounds in the product. In this paper, we present the application of DHS (dynamic headspace) as a sample preparation technique for fragrance analysis in consumer products and compare the results obtained with the conventional technique of SDE. EXPERIMENTAL Instrumentation. Analyses were performed using a 7890 GC equipped with a 97 Mass Selective Detector (Agilent Technologies), Thermal Desorption Unit (TDU, Gerstel), PTV inlet (CIS 4, Gerstel) and MPS with DHS option (Gerstel). The GERSTEL Dynamic Headspace System (DHS) is an accessory for the MultiPurpose Sampler (MPS ) that enables dynamic purging of the headspace above a sample combined with trapping of purged analytes on an adsorbent trap. In this work, a low volume aliquot of the sample is placed into an empty headspace vial, which is thermostatted to 80 C allowing the fragrance compounds to vaporize while leaving most of the low volatile matrix behind. The technique of introducing a small volume of sample and vaporizing the analytes in the headspace vial completely, without having to rely on establishing equilibrium between two phases, is called FET or full evaporation technique [, ]. Analytes in the purged headspace are trapped onto a cm adsorbent bed in a compact glass tube. The tube is then placed into the Thermal Desorption Unit (TDU) and the analytes thermally desorbed and introduced into the gas chromatograph. The analytes are focused in the Cooled Injection System (CIS 4) inlet to improve peak shape and increase sensitivity. Figure shows a schematic of the trapping and desorption process. Figure. GERSTEL MPS with DHS on an Agilent Technologies 7890 GC. AN/009/8 -

Figure. Schematic View of DHS Process. Analysis conditions. Trap: Tenax TA DHS: 0 C trap temperature 80 C incubation temperature No. Compound 00 ml purge volume 0 ml/min purge flow TDU: solvent venting 0 C ( min); 00 C/min; 0 C ( min) PTV: Tenax TA liner, 0. min solvent vent (0 ml/min) split 0: 0 C; C/s; 80 C ( min) Column: 0 m Stabilwax (Restek) d i = 0. mm d f = 0. μm Pneumatics: He, constant flow = ml/min Oven: 40 C ( min); C/min; 40 C (0 min) MSD: Scan, 9-0 amu Sample Preparation. g of liquid or solid sample and methanol, depending on the expected fragrance concentration in the sample, were added to a vial and thoroughly mixed. 8 μl of the liquid phase were then transferred into an empty 0 ml screw cap headspace vial. RESULTS AND DISCUSSION In order to have comparable results, a fragrance of known composition was created and incorporated into a shower gel. Sample preparation of this gel was subsequently performed with Likens-Nickerson extractions using hexane or alternatively frigene as solvent. Table shows compound recoveries from the extractions and the DHS run compared with the fragrance formulation normalized to 00%. AN/009/8 - Table. Comparison of recoveries of fragrance compounds using different extraction methods. Likens-N. Hexane Likens-N. Frigene DHS Ethyl Butyrate 40 0 80 Limonene 67 8 Hexyl Acetate 0 90 90 4 Allyl Caproate 60 00 0 Dihydromyrcenol 6 7 00 6 Linalool 8 00 9 7 Agrumex 96 08 97 8 -Terpineol 7 00 90 9 Styrallyl Acetate 7 0 99 0 Benzyl Acetate 00 0 8 Florol 6 98 Dihydrojasmone 0 00 9 DMBC Butyrate 4 79 0 4 ß-Ionone 67 90 cis-jasmone 9 7 Lilial 8 7 49 8 Bacdanol 0 0 8 9 Hydroxycitronellol n.d. n.d. 09 0 Aldehyde C-4 7 0 0 Hedione 67 0 9 Galaxolide 0 IPM 0 8 Hexylcinnamic 00 60 8 Aldehyde 4 Helional 69 7 Coumarin 80 9 86 6 Ethylvanillin trace 60 7 Musk T 9 78 8 Frambinone n.d. n.d. 49

In general the results obtained using the DHS technique were closer to the original composition of the fragrance than those obtained by the extractions. The overlay-chromatogram in figure demonstrates good correlation between sample and fragrance, but also gives some hints as to the composition of the matrix. Abundance 000000 6,7 7 4 7 8 4000000 000000 000000 000000 4 7 9 0 4, 8 6 8 9 0 6 4 6 7 8 Time--> 0.00 0.00 0.00 40.00 0.00 60.00 Figure 4. Overlay of fragrance standard trace (black) and shower gel trace (red). Blue annotations mark fragrance compounds (see tables), green annotations mark matrix compounds:. methyl laurate,. n-dodecanol,. caprylic acid, 4. -phenoxyethanol,. lauryl ethoxylate, 6. lauric acid, 7. methyl p-hydroxybenzoate, 8. N- propyl p-hydroxybenzoate. The main reason for this is that the DHS technique results in quantitative and exhaustive extraction of the small amounts of sample, i.e. complete extraction of all fragrance compounds present in the samples. This is a big advantage compared with standard extraction techniques (SDE/SPME), which yield lower, and in some cases significantly lower, recovery for less volatile compounds such as ethylvanillin, coumarin and some musk compounds. Using DHS, both volatile and less volatile compounds are extracted from the product matrices with high recovery making it much easier to achieve the correct analysis result in terms of overall composition of the fragrance. In the next step, the experiment was extended to handling more challenging matrices. Since we know that a nearly quantitative extraction of the fragrance compounds is in principle possible, we looked into the area of the stability of a fragrance formulation or of individual compounds depending on matrix composition. To investigate this, different consumer products, in addition to the shower gel, were formulated using the very same fragrance. These were a soap bar, a candle, an antiperspirant spray and a hair dye product. It was expected, that the fragrance that was originally designed for use in a shower gel would not be completely stable in other matrices. These products were analyzed by DHS and the results obtained were compared to the original composition of the fragrance (Table ). AN/009/8-4

Table. Comparison of recoveries of fragrance compounds from different matrices. No. Compound Shower Gel Bar Soap Candle Wax AT Spray Hair Color Ethyl Butyrate 80 n.d. n.d. n.d. Limonene 8 0 64 0 Hexyl Acetate 90 n.d. n.d. 4 Allyl Caproate 0 n.d. 7 n.d. Dihydromyrcenol 00 96 48 74 4 6 Linalool 9 9 9 6 4 7 Agrumex 97 99 7 8 -Terpineol 90 04 9 6 9 Styrallyl Acetate 99 4 40 6 n.d. 0 Benzyl Acetate 8 n.d. Florol 98 08 4 Dihydrojasmone 9 0 4 49 9 DMBC Butyrate 0 0 6 87 4 4 ß-Ionone 90 0 49 4 cis-jasmone 9 47 46 n.d. 6 Clonal 96 99 46 74 n.d. 7 Lilial 49 60 trace 8 Bacdanol 8 9 4 n.d. 8 9 Hydroxycitronellol 09 7 44 6 0 Aldehyde C-4 0 6 70 n.d. Hedione 9 99 48 8 4 Galaxolide 0 IPM 8 7 6 4 Hexylcinnamic Aldehyde 8 0 7 4 Helional 7 n.d. 7 8 n.d. Coumarin 86 00 4 7 n.d. 6 Ethylvanillin 9 n.d. 7 Musk T 9 78 0 7 8 n.d. 8 Frambinone 49 4 8 n.d. AN/009/8-

Figure 4 shows the results for the soap bar. The most volatile part of the fragrance formulation (compounds -4) was lost probably due to the high processing temperature when incorporating the fragrance into the soap. In addition limonene () is known not to be stabile in soaps. Benzyl acetate (0) was partially transformed to benzyl alcohol and the aldehydes (0, 4) had reacted with amines from the matrix. Musk T 9 (Ethylen brassylate) seems to have been partially converted to dimethyl brassylate. Abundance 000000 4000000 6,7 7 000000 000000 000000 4 7 9 0 4, 8 6 8 9 0 4 6 8 Time--> 0.00 0.00 0.00 40.00 0.00 60.00 Figure 4. Overlay of fragrance standard trace (black) and bar soap trace (red). Blue annotations mark fragrance compounds (see tables), green annotations mark:. benzyl alcohol,. dimethyl brassylate. In the candle wax sample the high processing temperature of C caused losses over the entire range of fragrance compounds, whereas the overall fragrance pattern remained stabile (figure ). Abundance 000000 4000000 6,7 7 000000 000000 000000 4 7 9 0 4, 8 6 8 9 0 4 6 8 Time--> 0.00 0.00 0.00 40.00 0.00 60.00 Figure. Overlay of fragrance standard trace (black) and candle wax trace (red). Blue annotations mark fragrance compounds (see tables). AN/009/8-6

For some applications, such as the antiperspirant spray, using the classical technique of SDE is not even an option since, due to the products composition (mainly propellant), the amount of sample coming from a commercial product is quite low. Abundance 000000 4000000 6,7 7 000000 000000 000000 4 7 9 0 4, 8 6 8 9 0 4 6 8 Time--> 0.00 0.00 0.00 40.00 0.00 60.00 Figure 6. Overlay of fragrance standard trace (black) and antitranspirant trace (red). Blue annotations mark fragrance compounds (see tables). Regarding stability testing of fragrances in hair dye products DHS is a powerful tool for evaluating both performance & stability. As can be seen in figure 7 the DHS analysis clearly shows that some of the compounds present in the original fragrance (Lilial, Hedione, Hexyl cinnamic aldehyde etc ) vanished almost completely in the aggressive environment in the hair dyes. Abundance 6,7 7 000000 4000000 000000 000000 000000 4 7 9 0 4, 8 6 8 9 0 4 6 8 Time--> 0.00 0.00 0.00 40.00 0.00 60.00 Figure 7. Overlay of fragrance standard trace (black) and haircoloration trace (red). Blue annotations mark fragrance compounds (see tables). AN/009/8-7

CONCLUSIONS DHS is an excellent technique for the determination of fragrances in consumer products. DHS, using the fully evaporization technique FET, enables quantitative extraction of fragrance compounds across a wide range of volatility, leading to results that are closer to the actual fragrance composition than those obtained with other commonly used analysis techniques. In addition, less volatile compounds that could not be determined when common extraction techniques were used, were determined using DHS. REFERENCES [] M. Markelov, J.P. Guzowski, Jr., Analytica Chimica Acta, 76 (99) -4 [] M. Markelov, O.A. Bershevits, Analytica Chimica Acta, 4 (00) -7 AN/009/8-8

AN/009/8-9

GERSTEL GmbH & Co. KG Eberhard-Gerstel-Platz 447 Mülheim an der Ruhr Germany +49 (0) 08-7 6 0-0 +49 (0) 08-7 6 0 gerstel@gerstel.com www.gerstel.com GERSTEL Worldwide GERSTEL, Inc. 70 Digital Drive, Suite J Linthicum, MD 090 USA + (40) 47 88 + (40) 47 887 sales@gerstelus.com www.gerstelus.com GERSTEL AG Wassergrabe 7 CH-60 Sursee Switzerland +4 (4) 9 97 gerstelag@ch.gerstel.com www.gerstel.ch GERSTEL K.K. -- Nakane, Meguro-ku Tokyo -00 SMBC Toritsudai Ekimae Bldg 4F Japan +8 7 +8 7 info@gerstel.co.jp www.gerstel.co.jp GERSTEL LLP Level, North Tower One Raffles Quay Singapore 0488 +6 66 486 +6 66 999 SEA@gerstel.com www.gerstel.com GERSTEL Brasil Av. Pascoal da Rocha Falcão, 67 0478-000 São Paulo - SP Brasil + ()66-89 + ()666-9084 gerstel-brasil@gerstel.com www.gerstel.com.br Information, descriptions and specifications in this Publication are subject to change without notice. GERSTEL, GRAPHPACK and TWISTER are registered trademarks of GERSTEL GmbH & Co. KG. Copyright by GERSTEL GmbH & Co. KG Awarded for the active pursuit of environmental sustainability