Detection of Emission Sources Using Passive-Remote Fourier Transform Infrared Spectroscopy*

Similar documents
DETECTING AND QUANTIFYING LEWISITE DEGRADATION PRODUCTS I N ENVIRONMENTAL SAMPLES USING ARSENIC SPECIATION*

Inside Wall Temperature Measurements of DSTs Using an Infrared Temperature Sensor

Plasma Response Control Using Advanced Feedback Techniques

Use of AVHRR-Derived Spectral Reflectances to Estimate Surface Albedo across the Southern Great Plains Cloud and Radiation Testbed (CART) Site

Analysis of Shane Telescope Aberration and After Collimation

PROJECT PROGRESS REPORT (03/lfi?lfibr-~/15/1998):

Abstract of paper proposed for the American Nuclear Society 1997 Winter Meeting Albuquerque, New Mexico November 16-20, 1997

DE '! N0V ?

Magnetic Measurements of the Elliptical Multipole Wiggler Prototype

Development of a High Intensity EBIT for Basic and Applied Science

BWXT Y-12 Y-12. A BWXT/Bechtel Enterprise SMALL, PORTABLE, LIGHTWEIGHT DT NEUTRON GENERATOR FOR USE WITH NMIS

Use of Gamma Rays from the Decay of 13.8-sec "Be to Calibrate a Germanium Gamma Ray Detector for Measurements up to 8 MeV

APPLICATION SINGLE ION ACTIVITY COEFFICIENTS TO DETERMINE SOLVENT EXTRACTION MECHANISM FOR COMPONENTS OF NUCLEAR WASTE

INTERMOLECULAR POTENTIAL FUNCTIONS AND HIGH RESOLUTION MOLECULAR SPECTROSCOPY OF WEAKLY BOUND COMPLEXES. Final Progress Report

Optimization of NSLS-II Blade X-ray Beam Position Monitors: from Photoemission type to Diamond Detector. P. Ilinski

ust/ aphysics Division, Argonne National Laboratory, Argonne, Illinois 60439, USA

ION EXCHANGE SEPARATION OF PLUTONIUM AND GALLIUM (1) Resource and Inventory Requirements, (2) Waste, Emissions, and Effluent, and (3) Facility Size

ADSORPTION ON NANOSURFACES: A DETAILED LOOK AT METAL CLUSTERS USING INFRARED SPECTROSCOPY

(4) How do you develop an optimal signal detection technique from the knowledge of

CQNl_" RESPONSE TO 100% INTERNAL QUANTUM EFFICIENCY SILICON PHOTODIODES TO LOW ENERGY ELECTRONS AND IONS

GA A22722 CENTRAL THOMSON SCATTERING UPGRADE ON DIII D

AC dipole based optics measurement and correction at RHIC

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

MAGNETIC RESONANCE IMAGING OF SOLVENT TRANSPORT IN POLYMER NETWORKS

Applications of Pulse Shape Analysis to HPGe Gamma-Ray Detectors

K.M. Hoffmann and D. C. Seely

Cable Tracking System Proposal. Nick Friedman Experimenta1 Facilities Division. June 25,1993. Advanced Photon Source Argonne National Laboratory

UPGRADED CALIBRATIONS OF THE THOMSON SYSTEM AT DIII D

UNIT OPERATIONS AND CHEMICAL PROCESSES. Alan M. Krichinsky

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

Manifestations of the axial anomaly in finite temperature QCD

Data Comparisons Y-12 West Tower Data

Status and Progress of a Fault Current Limiting HTS Cable To Be Installed In The Consolidated Edison Grid

Experimental Facilities Division, Advanced Photon Source, Argonne National Laboratoty, Argonne, Illinois 60439

Tell uric prof i 1 es across the Darrough Known Geothermal Resource Area, Nevada. Harold Kaufniann. Open-file Report No.

Electron Transfer of Carbonylmetalate Radical Pairs: Femtosecond Visible Spectroscopy of Optically Excited Ion Pairs

Excitations of the transversely polarized spin density. waves in chromium. E3-r 1s

sample-specific X-ray speckle contrast variation at absorption edges $ & ~ 0

m w n? r i OF,THISDOCUMENT IS UNLIMITED

GA A27806 TURBULENCE BEHAVIOR AND TRANSPORT RESPONSE APPROACHING BURNING PLASMA RELEVANT PARAMETERS

Hydra Fault Current Limiting HTS Cable to be Installed in the Consolidated Edison Grid

Magnetic Resonance Imaging of Polymer Electrolytes and Insertion Electrodes*

Centrifugal Destabilization and Restabilization of Plane Shear Flows

RESEARCH OPPORTUNITIES AT THE CNS (Y-12 AND PANTEX) NUCLEAR DETECTION AND SENSOR TESTING CENTERS (NDSTC)

Three-Dimensional Silicon Photonic Crystals

A Distributed Radiator, Heavy Ion Driven Inertial Confinement Fusion Target with Realistic, Multibeam Illumination Geometry

Direct Determination of the Stacking Order in Gd 2 O 3 Epi-Layers on GaAs

RESONANCE INTERFERENCE AND ABSOLUTE CROSS SECTIONS IN NEAR-THRESHOLD ELECTRON-IMPACT EXCITATION OF MULTICHARGED IONS

C o f l F - 9m307-- SPREADSHEET APPLICATION TO CLASSIFY RADIOACTIVE MATERIAL FOR SHIPMENTa. A. N. Brown

ABSTRACT INTRODUCTION

Ray M. Stringfield Robert J. Kares J. R. Thomas, Jr.

GA A22677 THERMAL ANALYSIS AND TESTING FOR DIII D OHMIC HEATING COIL

A New Computational Method for non-lte, the Linear Response Matrix

Valley-Fill Sandstones in the Kootenai Formation on the Crow Indian Reservation, South-Central Montana

The Gas Flow from the Gas Attenuator to the Beam Line

Process Systems Engineering

A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy

Measurement of Low Levels of Alpha in 99M0Product Solutions

Flipping Bits in the James Webb Space Telescope s Cameras

National Accelerator Laboratory

Valley-Fill Sandstones in the Kootenai Formation on the Crow Indian Reservation, South-Central Montana

Barry M. Lesht. Environmental Research Division Argonne National Laboratory Argonne, Illinois 60439

~ _- IDOCLRXKT DMSP SATELLITE DETECTIONS OF GAMMA-RAY BURSTS. J. Terrell, NIS-2 P. Lee, NIS-2 R W.

Turbulent Scaling in Fluids. Robert Ecke, MST-10 Ning Li, MST-10 Shi-Yi Li, T-13 Yuanming Liu, MST-10

GA A25658 PRECISION X-RAY OPTICAL DEPTH MEASUREMENTS IN ICF SHELLS

EFFECTS OF AXIAL HEAT CONDUCTION AND MATERIAL PROPERTIES ON THE PERFORMANCE CHARACTERISTICS OF A THERMAL TRANSIENT ANEMOMETER PROBE

Summary Report: Working Group 5 on Electron Beam-Driven Plasma and Structure Based Acceleration Concepts

National Accelerator Laboratory

August 3,1999. Stiffness and Strength Properties for Basic Sandwich Material Core Types UCRL-JC B. Kim, R.M. Christensen.

A lattice dynamical investigation of zircon (ZrSiOJ has been carried out to obtain a

RWM FEEDBACK STABILIZATION IN DIII D: EXPERIMENT-THEORY COMPARISONS AND IMPLICATIONS FOR ITER

To be published in the Proceedings of ICEC-22, Seoul Korea, July 2008 MICE Note 232 1

Plutonium 239 Equivalency Calculations

Controlling Backstreaming Ions from X-ray Converter Targets with Time Varying Final Focusing Solenoidal Lens and Beam Energy Variation

SciDAC CENTER FOR SIMULATION OF WAVE-PLASMA INTERACTIONS

J. T. Mihalczo. P. 0. Box 2008

Microscale Chemistry Technology Exchange at Argonne National Laboratory - East

Los Alamos. OF nm LA-"'- Title: HYBRID KED/XRF MEASUREMENT OF MINOR ACTINIDES IN REPROCESSING PLANTS. S. T. Hsue and M. L.

GA A22689 SLOW LINER FUSION

Synthesis of Methyl Methacrylate from Coal-derived Syngas

FUSION TECHNOLOGY INSTITUTE

Fission-Fusion Neutron Source

The photoneutron yield predictions by PICA and comparison with the measurements

BASAL CAMBRIAN BASELINE GEOLOGICAL CHARACTERIZATION COMPLETED

: Y/LB-16,056 OAK RIDGE Y-12 PLANT

Using the X-FEL to understand X-ray Thomson scattering for partially ionized plasmas

Design of Current Leads for the MICE Coupling Magnet

Multicusp Sources for Ion Beam Lithography Applications

GA A24166 SUPER-INTENSE QUASI-NEUTRAL PROTON BEAMS INTERACTING WITH PLASMA: A NUMERICAL INVESTIGATION

EXPLOSIVE PARTICLES PARVLENE ENCAPSUTION. lac0 b Sando v a t. Normal Process Development OCTOBER DEVEZOPMENT D I V I S I O N DEZEMBER 1971

Paper to be submitted to. Thermal Management Technology for Hydrogen Storage: Fullerene Option?

electronic image products. Images are produced from the best available original document.

Experiment. The Pinhole Neutron. Pinex. c. c. sartain UCRL-ID November 21,1958

IMAGING OF HETEROGENEOUS MATERIALS BY. P. Staples, T. H. Prettyman, and J. Lestone

The Impacts of Carbon Dioxide Storage in the Saline Arbuckle Aquifer on Water Quality in Freshwater Aquifers in Kansas

12/16/95-3/15/96 PERIOD MULTI-PARAMETER ON-LINE COAL BULK ANALYSIS. 2, 1. Thermal Neutron Flux in Coal: New Coal Container Geometry

GA A23713 RECENT ECCD EXPERIMENTAL STUDIES ON DIII D

GA A23736 EFFECTS OF CROSS-SECTION SHAPE ON L MODE AND H MODE ENERGY TRANSPORT

A Few-Group Delayed Neutron Model Based on a Consistent Set of Decay Constants. Joann M. Campbell Gregory D. Spriggs

PROJECT PROGRESS REPORT (06/16/1998-9/15/1998):

Transcription:

Detection of Emission Sources Using Passive-Remote Fourier Transform Infrared Spectroscopy* Jack C. Demirgian, Susan M. Macha, and Shauna M. Darby Argonne National Laboratory Analytical Chemistry Laboratory Chetaieal Technology Division 9700 South Cass Avenue Argonne, Illinois 60439 and John Ditillo U.S. Army Ldgewood Research, Development, and Engineering Center Attention: SMCCR-DDT Building E5554 Aberdeen Proving Ground, Maryland 21010 DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product or process disclosed, or represents that its use would not infringe privately owned rights Reference herein to any specific commercial product, process, or service by trade name, trademark manufacturer, or otherwise does not necessarily constitute or imply its endorsement recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. to be published in the Proceedings of the Fourth International Symposium on Field Screening Methods For Hazardous Wastes and Toxic Chemicals February 22-24, 1995 Las Vegas, NV 89193-3478 The submitted manuscript has been authored by a contractor of the U. S. Government under contract No. W-31-109-ENG-38. Accordingly, the U S. Government retains * nonexclusive, royalty-free license to publish or reproduce the published form of this contribution, or allow others TO do so, for U. S. Government purposes. DISTRIBUTION OF THIS DOCUMENT IS UNLIMITED *Work supported by the U.S. Department of Energy under Contract W-31-109-Eng-38.

Detection of Emission Sources Using Passive-Remote Fourier Transform Infrared Spectroscopy Jack C. Detnirgian, Susan M. Macha, and Shauna M. Darby Argonne National Laboratory Analytical Chemistry Laboratory Chemical Technology Division 9700 South Cass Avenue Argonne, Illinois 60439 John Ditillo U.S. Army Edgewood Research, Development, and Engineering Center Attention: SMCCR-DDT Building E5554 Aberdeen Proving Ground, Maryland 21010 ABSTRACT The detection and identification of toxic chemicals released in the environment is important for public safety. Passive-remote Fourier transform infrared (FTIR) spectrometers can be used to detect these releases. Their primary advantages are their small size and ease of setup and use. Open-path FTIR spectrometers are used to detect concentrations of pollutants from a fixed frame of reference. These instruments detect plumes, but they are too large and difficult to aim to be used to track a plume to its source. Passive remote FTIR spectrometers contain an interferometer, optics, and a detector. They can be used on tripods and in some cases can be hand-held. A telescope can be added to most units. We will discuss the capability of passive-remote FTIR spectrometers to detect the origin of plumes. Low concentration plumes were released using a custom-constructed vaporizer. These plumes were detected with different spectrometers from different distances. Passive-remote spectrometers were able to detect small 10 cm on a side chemical releases at concentration-pathlengths at the low parts per million-meter (ppm-m) level. INTRODUCTION Passive-remote FTIR spectrometers are an excellent tool for detecting toxic chemicals released in the environment. Their portability allows them to be used to determine the source of the chemical release. We will discuss the potential of passive-remote FTIR spectroscopy in terms oi detection levels and the effects of using the instrumentation under real field conditions. Data were collected using trees, grass, low sky, and brick wall backgrounds both with and without telescopes and with different field-of-views. The detection of environmentally hazardous chemicals is also possible with open-path and fixed-point methods, such as open- path FTIR spectroscopy and canister collection followed by gas chromatography/mass spectroscopy (GC/MS). However, these methods only detect chemical plumes; they cannot trace them to their source. It is important to discover the origin of a plume to determine responsibility for the release and to repair the cause of the leak. Source detection is especially important for fugitive emissions, unknown leaks, and for evaluating environmental compliance. Light, mobile instrumentation with real-time data analysis methods is essential for tracking a plume to its source. Passive-remote FTIR systems are light and transportable. Data analysis can be performed in real time. The basic system consists of an interferometer, focusing optics, and a detector. The instrumentation uses ambient energy as its infrared source. Data are transmitted directly to a laptop

computer. The systems discussed are either transportable or can be hand carried to facilitate detection of the plume source. Open-path and passive-remote FOR should be considered as complementary techniques. Open-path systems will provide semiquantitative data for emission levels from a fixed area over extended periods of time. Open-path units function best in a fixed position because they are large and require aiming. After an open-path unit detects a plume, passive-remote units can be used to track it to its source. Passive-remote instrumentation was used to detect a low ppm-m concentration-pathlength releases. A 1 ppm-m release corresponds to a 1-part per million (ppm) chemical release that has a width of one meter. This release would be identical to a 10-ppm release with a width of 0.1 m. These releases were performed using a specially designed vaporizer with a 10- x 10-cm orifice. The spectrometers detected plumes of this size from distances in excess of 50 m. Plumes can be detected from open windows and other low-volume sources. Larger passive-remote units mounted on a tripod or a moving vehicle can be used to initially detect a plume. After detection, smaller units can be used to determine the origin. Experimental Data were obtained using passive-remote spectrometers from Midac (Midac, Costa Mesa, CA), Bomem (Hartmann-Braun, Montreal, PQ), and Designs and Prototypes (Nashua, NH) Data were collected at 4 cm"' as files of single scans using software provided by coauthor J. Ditillo. Scans were coadded post-run for data analysis. Dimethyl methylphosphonate (DMMP), 97% purity, and methanol (MEOH) (high purity) were obtained from Aldrich Chemical Co. (Milwaukee, WI). Small-scale chemical releases were performed with a vaporizer constructed at the Argonne National Laboratory. The vaporizer was built to convert liquids into vapors at the ppm level. The unit consists of a blower motor connected to a main tube possessing a sidearm. The main tube contains the primary air flow at ambient temperature. The sidearm flow, approximately 10% of the total, is heated and evaporates the liquid release. Air traveling through rhe sidearm is heated to 135 C before reaching a Sono-tek ultrasonic atomizing nozzle, which converts the liquid into an aerosol. The aerosol vaporizes when it contacts the hot air in the sidearm. Liquid flow is monitored by a syringe pump. The exact flow is calculated from the volume displacement in the syringe. The nozzle is capable of atomizing the liquid to a particle size of 15 um. The warm air and vaporized solvent enter the main tube and are mixed with air at ambient temperature. The mixture passes through a baffle system in the 10- x 10-cm square exit pipe, to ensure thorough mixing and even flow throughout the chamber. At the orifice, the air exits at an average velocity of 165 cfm (4.7 nrvmin) and at 34 to 40 C, depending on ambient temperature. The variation in flow was measured at nine different places at the orifice of the vaporizer to determine the average release velocity. The square orifice provided a constant path length. The release was calculated in concentrationpathlength units of ppm-m. Results Passive-remote FTIR systems use ambient energy as their energy source. Hence, the energy available for detection is a function of the temperature of the background and the temperature of the release. The larger the difference in temperature (AT), the larger the peak. The vaporizer commonly released chemicals at 37 C ± 3 C. This temperature would increase on very hot days. When the background temperature is greater than the release temperature, an absorption spectrum is obtained. When the background is cooler than the release, an emission spectrum is obtained. Background temperatures vary widely. Grass und tree backgrounds are normally approximately equal to the ambient temperature. Low blue sky backgrounds are very cold. The greater the angle from the horizon, the lower the temperature. Even 10-20 angles are below 0 C. Higher angles rapidly approach -40 C, which is the limit of our pyrometer. The primary problem with low sky backgrounds is occasional large concentrations of ozone. Cloudy low sky backgrounds

are much warmer but show a great deal of temperature variation. Brick wall backgrounds heat and cool slowly and are, therefore, quite stable. The slow change does provide a reasonably stable blackbody background. They also absorb a large amount of heat. We have measured brick walls as hot as 80 C in the sun. Our first objective was to determine the detection levels under ideal laboratory conditions. This information can be used to determine applicable scenarios. Obviously, detection levels in the field would be less than those determined in the laboratory. The laboratory data would provide a benchmark for the feasibility of potential uses. Two chemicals were selected for release: Methanol (MEOH) is typical for solvents that could be escaping into the environment and DMMP is a safe surrogate for phosphate-based pesticides such as malathion and parathion. Laboratory Data Detection levels for MEOH and DMMP are at the low ppm-m level. Figure 1 shows transmission spectra of methanol releases that vary in concentration from 4.0-19.4 ppm-m. The spectra were obtained using a 50 C blackbody and a release temperature of 37 C (AT=13 C). The signal-to-noise (S/N) ratio is greater than 20. DMMP showed even more sensitivity. In Figure 2, the absorption spectra of four concentrations of DMMP are shown. The 1 ppm-m absorption has a S/N greater than 20. The effect of changes in temperature is shown in Figure 3. The top spectrum shows the absorption spectrum when AT is positive by 16 C and for the bottom spectrum AT is negative by 15 C. The amplitudes are virtually identical. The closer that AT approaches zero, the smaller the absorption or emission. However, the background temperature is never constant, and even though some scans will not show analyte, the compound can be detected when multiple scans are collected. Field Data Releases were performed directly in front of the spectrometer with the spectrometer aimed at different backgrounds. The intensity of the band is a function of AT. The change in temperature was largest for the low sky background. The trees were in tkz sun and considerably hotter than the grass, which was in the shade. In Figure 4, the spectra for methanol releases and their integrated peak areas are presented for data collected using low sky, treej, and grass backgrounds. The low sky spectrum was inverted to facilitate comparison. Ozone absorption may be quite high when low blue sky backgrounds are collected. In Figure 5, the ozone bands are clearly visible around 1100 cm' 1. However, even with the interference the methanol bands are clearly visible. Field Data Using A Telescope A telescope is essential for locating chemical plumes. Most vendors sell more than one power telescope, which provides flexibility in selecting a field-of-view. The Midac telescope would focus on the 10-cm release area at approximately 25 m from the vaporizer. The farther the instrument is from the release, the greater the area observed and the larger the more non-sample background in the spectrum. The effects are relatively minor with a stable temperature background such as a brick wall. In Figure 6, the methanol spectra obtained 50 and 60 feet from the release are shown. The peaks are easily recognized. Grass background is less stable and the effect of baseline shifting is more apparent. Methanol was released 50 feet from the telescope at concentrations of 5.3 and 19.4 ppm-m, as shown in Figure 7. The peaks are still discernable, but there is more noise and variation. Low sky provides a very difficult background. Although AT is large, the amount of ozone and the variation in temperature is very great, which causes an unstable background. In Figure 8, the spectra of 5.3 and 19.4 ppm-m methanol releases are shown. Data were collected 60 feet from the release. The changing low sky temperature causes the large slope in the background. The ozone is also readily discernable.

Hand-portable FTIR spectrometers can be easily carried to the source. One instrument tested. Designs and Prototypes miniftir, is very versatile. Its sensitivity is lower than larger units, but its portability can compensate for the reduced sensitivity. In Figure 9, a spectrum obtained using this instrument with a 19.4 ppm-m release in front of a 50 C blackbody is shown. CONCLUSIONS The data clearly show that passive-remote FTIR spectrometers have the sensitivity to detect low ppm-m releases in the environment. Different environmental backgrounds have particular advantages and disadvantages. Brick buildings provide a stable background, while low blue sky provides the highest AT but the least stability. Once a release is detected, smaller units can be used to discover the origin. Improved real time data analysis is needed. Edgewood Research, Development, and Engineering Center (ERDEC) is currently developing and testing detection algorithms. As they become available for use, we can expect increased usage of passive-remote FTIR spectrometers. -.00001 ^"~ w "^ 4.0 ppm 5.3 ppm kk/i 9.3 ppm M u -.00003 13.4 ppm 1 -.00007 1t :i ]! 1200.0 800.0 Wavenumbers (cm-1) Figure 1. Transmission Spectra of Methanol Releases at 37 against a 50 C Blackbody. i -.00005-19.4 ppm

.06 - DKI10 6.9 PPM-M DKI08 3.4 DKI06 1.45 DKI04 1.0 O o o en.02 1200 1000 Wavenumbers (cm 1) 800 Figure 2. Absorption Spectra of Four Concentrations of DMMP Release Against a 50 C Background.

1or O m.05.03-].01 - -.01 - -.03 - -.05 - A / \ ABSORPTION SPECTRUM / I dt = +16 A ' * / V /A / \ A V i / EMISSION SPECTRUM! / \ / dt - -15 V 1200 1000 800 WAVENUMBERS (CM-1) Figure 3. Comparison of Absorption and Emission Spectra of DMMP Caused by Changes in Temperature

19.4 PPM-M 1.12 32 COADDED SCANS 1.08.96- GRASSY KNOLL (1-56).92 1080 1040 Wavenumbers (cm 1) 100Q Rei = cm sea Figure 4. Spectra of Methanol Releases with Different Environmental Backgrounds.

.05.04 u S3-03 ] o 01 3.04-.03-03 -I DGR05ALL - 2.63PPM-M.02-1 DGRIOALL - 5.26 PPM-M 1120 1080 1040 1000 Arbitrary X 960 920 Figure 5. Methanol Release in Front of a Low Sky Background.

.004 002 \ DGZ25 19.4 PPM-M "-"" i\// V \ 60 1 FROMRELEASE /^S~^\^_ o 2 < QQ CH O in CD 0- k 002- DGZ21 19.4 PPM-M 50' FROM RELEASE I 1120 "080 10^0 1000 960 920 Figure 6. Methanol Release in Front of a Brick Wall Background.

0 5.3 PPM-M (DGZ0048) o c o JO ^_ o V) 0-19.4 PPM-M (DGZ0050) 0- -.01 - -.01-1100 ^000 Wcvenumce's (cm 1) Figure 7. Methanol Release in Front of a Grass Background. 90C

RELEASES WERE 60' FROM THE TELESCOPE.016 < 01 O 00 CD.014-.012-.01-1150 1050 950 WAVENUMBERS_ (CM-1) Figure 8. Methanol release in Front of a Low Sky Background.

an Q cc 8 COADDED SPECTRA 2.4 SEC/SCAN 15 -.4 - -.8- -1.2-1160 1120 1080 1040 1000 960 Wavenumbers (cm 1) 920 880 Figure 9. Infrared Spectrum of a Methanol Obtained Using a D&P MiniFTIR.